PROGRAMACION CONSTANTES DE LA BALANZA
2do NIVEL
TECLA: “SETUP”
“CODIGO DE ACCESO: 3400”
PROGRAMACION CONSTANTES DE LA BALANZA
2do NIVEL
“CODIGO DE ACCESO: 3400”
BALANZA No. 1 PADDY BALANZA No. 2 ENTERO
1 2
Scale Number
2 2
Set Weight Units
3 3
Decimal Point Position
4 4
Increment
2 0 0 . 0 0 5 0 . 0 0
Scale Capacity
Span Weight 2 0 0 . 0 0 0
Span Factor
1 6 9 4 2 0 8 1 6 9 6 6 7 2
SCL Overld Count
5 6 3 6 6 5 6 5 0 4
Span Factor Limit
9 9 9 9 9 9 9 9 9 9 9 9 9 9
Zero Offset
1 7 2 6 0 9 5 3 8 5 2 1 3 7
Zero Offset Limit
9 9 9 9 9 9 9 9 9 9 9 9 9 9
Auto Zero Offset
5 1 2 0 5 1 2 0
Auto Zero Limit
5 1 2 0 5 1 2 0
DTF
0 0
Check Frequency
1 1 0
Status Bits A
2 5 9 2 5 2 0
Status Bits B
0 0
Status Bits C
0 0
Minimun Set Weight
(optional) no aparece
Main Feed O/P
1 1
Dribble Feed O/P
2 2
Discharge O/P
3 3
Discharge Door
0 0
Closed I/P
Downstream Interlock
2 0
I/P
Span Weight O/P no aparece
4
Bag Clamp O/P no aparece no aparece
Clamp Close I/P no aparece no aparece
Override Open I/P no aparece no aparece
Bag in Posn I/P no aparece no aparece
Alarm O/P
0 0
Run/Slave I/P
0 0
Rem. Wt. Check I/P
0 0
Agitator O/P no aparece
0
Changeover O/P no aparece no aparece
Remote Start I/P
0 0
Remote Stop I/P
0 0
Top Hopper Low 0 0
Level Input
Remote Batch End I/P
0 0
Batch Out O/P
0 0
Scale Full O/P
0 0
Keyboard Disable I/P
0 0
2nd Feedrate I/P no aparece no aparece
Total Reset I/P no aparece no aparece
High Limit Alarm O/P
0 0
Lo Limit Alarm O/P
0 0
Slow Feed Alarm O/P
0 0
Pulse Total O/P
0 0
Watchdog O/P
0 0
Sync Check O/P 0 0
Weigher Status O/P
0 0
WGMT Ready O/P
0 0
Air Pressure I/P
3 0
Aspiration O/P
0 0
Feedrate Filter Response
1 1 1 1
Auto-Comp. Action 0 0
Speed
Auto-Comp. Limit 0 0
Totaliser Units
3 2
Totaliser D.P.P.
4 3
Totaliser Increment
3 4
Feedrate Units
3 3
Feedrate D.P.P.
3 3
Feedrate Increment 2 4
MTBF Cyclesx100
0 0
Conv. CAD. CODE no aparece
0
Input Filter Code
0 0
(PC456i and PC456r only)
Los siguientes Datos se deben modificar? En el archivo aparecen los siguientes valores
Converter Register A
8 3 8 8 6 0 8 8 3 8 8 6 0 8
(PC456i only)
Converter Register B
0 0
(PC456i only)
Converter Register C 8 3 8 8 6 0 8 8 3 8 8 6 0 8
(PC456i only)
Converter Register D 8 3 8 8 6 0 8 8 3 8 8 6 0 8
(PC456i and PC456r
only)
Converter Register E 8 3 8 8 6 0 8 8 3 8 8 6 0 8
(PC456i and PC456r
only)
Converter Register F
0 0
(PC456 and PC456r
only)
Converter Register G 1 1
(PC456i and PC456r
only)
Display Brightness 3 3
(PC456i and PC456r
only)
Analogue Output Code
0
(PC456i only) 2
Analogue Output Zero 1852
1 0
(PC456i only)
Analoge Output Span 51200
0
(PC456i only)
Analoge Output Max Rate 41.7 0
Pulse Totaliser
0 0
Increment
Channel I Baud no aparece no aparece
Rate (Printer)
Channel II Baud 7 0 7 0
Rate (Comms)
Entry Code
1 2 3 1 2 3
Power Cycles no se puede
2 2
modificar
Air Cycles no se puede
3
modificar
CUADRO RESUMEN
PROGRAMACION DE PARAMETROS
1er NIVEL
DESCRIPCION PARAMETROS BALANZA DE PADDY BALANZA DE ENTERO
TIME AND DATE - -
SCALE COMP 0.00 Kg. 3.31 Kg.
SCALE DRIB - -
MAX. SET WEIGHT 150.00 Kg. 50.00 Kg.
MIN DRIB TIME - -
AUTO DRIB TIME - -
STABILISATION TIME 3.0 sec 1.5 sec
DOOR CLOSE TIME 2.0 sec 2.0 sec
DICHARGE TIME 4.0 sec 2.5 sec
SLOW FEED TIME 30.0 sec 999.9 sec
F. RATE HI LIMIT 50.00 T/Hr 25.00 T/Hr
F. RATE LOW LIMIT 0.005 T/Hr 0.05 T/Hr
LO FEEDING TIMER 999.9 sec 999.9 sec