0% found this document useful (0 votes)
8 views7 pages

Pontianak 100m 35cbm 5.920Wp

The document outlines a solar pumping project in Pontianak, Indonesia, detailing specifications for a submersible pump system, including required daily output, system characteristics, and technical data. It includes information on the solar panel setup, wiring diagrams, system layout, and pump unit dimensions. The project aims to provide an efficient water supply solution using solar energy.

Uploaded by

Rizky Ananda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views7 pages

Pontianak 100m 35cbm 5.920Wp

The document outlines a solar pumping project in Pontianak, Indonesia, detailing specifications for a submersible pump system, including required daily output, system characteristics, and technical data. It includes information on the solar panel setup, wiring diagrams, system layout, and pump unit dimensions. The project aims to provide an efficient water supply solution using solar energy.

Uploaded by

Rizky Ananda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

PT Java Surya Teknik Fiqhi Robyansyah

Jl. Ahmad Yani No. 88, Surabaya Tel: +62 813 9227 6196
Graha Pena Jawa Pos, 7th floor Fax:
Surabaya [email protected]
www.sanspower.com

Tuesday, August 13, 2024


New project

Solar pumping project

Parameter
Location: Indonesia, Pontianak (1° South; 109° Water temperature: 25 °C
East)
Required daily output: 30 m³; Sizing for average month Dirt loss: 5,0 % Motor cable: 50 m
Pipe type: - Total dynamic head: 100 m Pipe length: -

Products Quantity Details


PS2-4000 C-SJ3-32 1 pc. Submersible pump system including controller with DataModule, motor and pump end
MAYSUN 370M 16 pc. 5.920 Wp; 8 x 2 modules; 15 ° tilted
Motor cable 50 m 4 mm² 3-phase cable for power and 1-phase cable for ground
Accessories 1 set Surge Protector2, Water Level Measurement Solution, PV Disconnect 400-50-3-S

Sun Sensor setting in PumpScanner min. 100 W/m²


Daily output in average month 35 m³
Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Output [m³]

Energy [kWh] 24 26 27 27 29 30 30 30 27 25 23 22 27
Irradiation [kWh/m²] 4,5 5,0 5,1 5,3 5,5 5,8 5,7 5,7 5,2 4,8 4,4 4,2 5,1
Rainfall [mm] 11 7,4 10 11 9,9 7,4 6,9 5,9 9,8 11 13 11 9,4
Ambient temp. [°C] 25 26 26 26 26 27 27 27 27 26 26 26 26

Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00

Output [m³/h]

Energy [kWh] 0 0,79 1,7 2,5 3,1 3,5 3,6 3,4 3,1 2,5 1,7 0,77 0
Irradiation [kWh/m²] 0 0,14 0,31 0,47 0,60 0,67 0,70 0,67 0,60 0,47 0,31 0,14 0
Ambient temp. [°C] 21 21 22 24 26 28 30 31 31 31 31 30 30

Created by LORENTZ COMPASS 3.1.0.240


1/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
PT Java Surya Teknik Fiqhi Robyansyah
Jl. Ahmad Yani No. 88, Surabaya Tel: +62 813 9227 6196
Graha Pena Jawa Pos, 7th floor Fax:
Surabaya [email protected]
www.sanspower.com

Tuesday, August 13, 2024


New project

Solar pumping project

System characteristic

Min. 800 W/m², 20 °C Max./STC*


PV generator Cell temperature [°C] 46 25
Temperature loss [%] 7,1 -
Dirt loss [%] 5,0 -
Pmax [Wp] 4.180 5.920
Vmp [V] 254 274
Imp [A] 16 22
Voc [V] 307 330
Isc [A] 17 23
Pout [W] 2.930 -
Vout [V] 286 -
Iout [A] 11 -
Motor cable Power loss [%] 1,2 3,0 3,0
Pump systems Motor power [W] 391 2.820 2.820
Motor voltage [V EC] 122 202 202
Motor current [A] 3,2 14 14
Motor speed [rpm] 2.125 3.035 3.035
Flow rate [m³/h] 0 4,1 4,1
Efficiency [%] 0 39 43
*STC: Standard test conditions for photovoltaic modules, 1000 W/m² solar iradiance, 25 °C cell temperature

Created by LORENTZ COMPASS 3.1.0.240


2/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
PT Java Surya Teknik Fiqhi Robyansyah
Jl. Ahmad Yani No. 88, Surabaya Tel: +62 813 9227 6196
Graha Pena Jawa Pos, 7th floor Fax:
Surabaya [email protected]
www.sanspower.com

Tuesday, August 13, 2024


New project

Solar pumping project

Wiring diagram

Created by LORENTZ COMPASS 3.1.0.240


3/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
PT Java Surya Teknik Fiqhi Robyansyah
Jl. Ahmad Yani No. 88, Surabaya Tel: +62 813 9227 6196
Graha Pena Jawa Pos, 7th floor Fax:
Surabaya [email protected]
www.sanspower.com

Tuesday, August 13, 2024


New project

Solar pumping project

System Layout

1: PS2 Controller 11: Float Switch


2: Submersible Pump 12: Sun Switch
3: Flow Sleeve 13: PV Disconnect
4: Well Probe 14: Lightning Surge Protector
5: Cable Splice Kit 15: PV Generator
6: Grounding Rod *It is recommended to install a Surge Protector at each
controller sensor input.
7: Surge Protector*
8: Safety Rope
9: Water Meter
10: Pressure Sensor

Created by LORENTZ COMPASS 3.1.0.240


4/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
PT Java Surya Teknik Fiqhi Robyansyah
Jl. Ahmad Yani No. 88, Surabaya Tel: +62 813 9227 6196
Graha Pena Jawa Pos, 7th floor Fax:
Surabaya [email protected]
www.sanspower.com

Tuesday, August 13, 2024


New project

Solar pumping project

Sizing Layout

H (Static head): Vertical height from the dynamic water level to the highest point of delivery.
B (Drawdown): Lowering of water level depending on flow rate and recovery rate of the well.
D (Pipeline inner diameter)
L (Pipe length): Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an
equivalent length of pipeline.
M (Motor cable): The cable between controller and pump unit.
T (Tilt angle): Angle of the PV generator surface from the horizontal plane.

Created by LORENTZ COMPASS 3.1.0.240


5/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
PS2-4000 C-SJ3-32
Solar Submersible Pump System for 4" wells

System Overview
Head max. 220 m
Flow rate max. 4,2 m³/h

Technical Data
Controller PS2-4000
ƒControlling and monitoring
ƒControl inputs for dry running protection, remote control etc.
ƒProtected against reverse polarity, overload and overtemperature
ƒIntegrated MPPT (Maximum Power Point Tracking)
ƒIntegrated Sun Sensor

Power max. 4,0 kW


Input voltage max. 375 V
Optimum Vmp** > 238 V
Motor current max. 14 A
Efficiency max. 98 %
Ambient temp. -40...50 °C
Enclosure class IP68

Motor ECDRIVE 4000-C


ƒMaintenance-free brushless DC motor
ƒWater filled
ƒPremium materials, stainless steel: AISI 304/316
ƒNo electronics in the motor
Rated power 4,0 kW
Efficiency max. 92 %
Motor speed 900...3.300 rpm
Insulation class F
Enclosure class IP68
Submersion max. 150 m
Pump End PE C-SJ3-32
ƒNon-return valve
ƒPremium materials, stainless steel: AISI 304
ƒCentrifugal pump
Efficiency max. 52 %

Pump Unit PU4000 C-SJ3-32 (Motor, Pump End)


Borehole diameter min. 4,0 in
Water temperature max. 50 °C

Standards
2006/42/EC, 2004/108/EC, 2006/95/EC

IEC/EN 61702:1995, IEC/EN 62253 Ed.1

The logos shown reflect the approvals that have been granted for this product family. Products are ordered and supplied with the approvals specific to the market
requirements.
**Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature

BERNT LORENTZ GmbH


Siebenstuecken 24, 24558 Henstedt-Ulzburg,
Germany, Tel +49 (0)4193 8806-700, www.lorentz.de

Created by LORENTZ COMPASS 3.1.0.240


All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.Pictures may differ from actual
products depending on local market requirements and regulations.
PS2-4000 C-SJ3-32
Solar Submersible Pump System for 4" wells

Pump Chart Vmp* > 238 V

Dimensions and Weights


Controller Pump Unit

H1 = 352 mm A= 1.088 mm
H2 = 333 mm B= 245 mm
W1 = 207 mm C= 843 mm
W2 = 170 mm D= 96 mm
W3 = 164 mm E= 98 mm
D1 = 124 mm S= 1,25 in

Net weight
Controller 6,1 kg
Pump Unit 20 kg
Motor 10 kg
Pump End 9,5 kg

*Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature

BERNT LORENTZ GmbH


Siebenstuecken 24, 24558 Henstedt-Ulzburg,
Germany, Tel +49 (0)4193 8806-700, www.lorentz.de

Created by LORENTZ COMPASS 3.1.0.240


All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.Pictures may differ from actual
products depending on local market requirements and regulations.