The Kidde Smoke Alarm model 20SAR features interconnected alarms that activate simultaneously, enhanced sensing technology to reduce false alarms, and self-testing capabilities for reliability. It is powered by 120V AC with a backup of 2 AA batteries, ensuring continuous operation during outages. The alarm includes end-of-life notifications and is designed to meet the latest safety standards for optimal fire detection.

Uploaded by

ELY ESTRADA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views2 pages

Product Pds 20sar 1223

The Kidde Smoke Alarm model 20SAR features interconnected alarms that activate simultaneously, enhanced sensing technology to reduce false alarms, and self-testing capabilities for reliability. It is powered by 120V AC with a backup of 2 AA batteries, ensuring continuous operation during outages. The alarm includes end-of-life notifications and is designed to meet the latest safety standards for optimal fire detection.

Uploaded by

ELY ESTRADA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SMOKE ALARM

HARDWIRED + AA BACKUP BATTERY (INCLUDED)

DETECT SERIES | MODEL 20SAR

INTERCONNECTED ALARMS*
When one alarm sounds, they all sound, so you never miss
an emergency and can get out faster.

REDUCED NUISANCE ALARMS


Enhanced sensing technology reduces false alarms often
caused by cooking.

SELF-TESTING**
For added assurance, internal components ensure alarm
is always operating as expected. Images are representative only.
Actual product may vary slightly.

Description Features & Benefits


North America’s #1 home fire safety brand (based on total household • 2 AA Replaceable Batteries – Provides power even during short-term
installations as of December 2022) is bringing you the next level of fire safety power outages for extra peace of mind. Change replaceable batteries
with the Kidde Smoke Alarm model 20SAR. every 6 months, or when you hear the low battery chirp.
This alarm offers a modern 5” design ideal for all living spaces. Cutting
edge technology sends fast alerts that give your family more time to get out • Interconnected Alarms* – When one alarm sounds, they all sound, so
safely and enhanced sensing technology reduces false alarms often caused you never miss an emergency and can get out faster.
by cooking.
Comprehensively tested and designed to the latest UL standard for safety • Self-testing Alarms** – For added assurance, internal components
and reliability, this Kidde DETECT alarm is powered by 120V AC with 2 AA ensure alarm is always operating as expected.
replaceable backup batteries (included) for continual detection even during
outages. • Simple Installation – Easy install with included twist-and-click
Plus, it’s self-testing and easy to install with the included twist-and-click mounting bracket.
mounting bracket. Equipped with end-of-life notifications, the alarm will beep
to remind you it’s time to replace it 10 years after it is powered. The alarm • End-of-life Notifications – This alarm beeps to remind you it’s time to
also has interconnected alarm activation so you never miss an emergency replace it 10 years after it is powered.
and can get out faster.

Alarm Warnings – featuring multi-color LEDs Installation of Alarm


Fire: The red LED will flash in sync with the alarm pattern (3 long beeps). This model meets the latest residential smoke alarm standards, which
The alarm will repeat this pattern until the unit is reset or smoke is eliminated. includes enhanced resistance to nuisance alarms from cooking. Industry
experts recommend that both ionization and photoelectric smoke alarms be
Low Battery: One chirp and amber LED flash per minute. installed to help ensure optimal detection of the various types of fires that
can occur within the home. Ionization sensing alarms may detect invisible fire
Alarm Memory: Alerts a user if smoke has been detected in the last 24 particles (associated with fast flaming fires) sooner than photoelectric alarms.
hours. If smoke has been detected, the red LED blinks every 15 seconds. Photoelectric sensing alarms may detect visible fire particles (associated

*Different models offer different interconnect options and requirements. Check the User Guide for
more info. **Self-testing is not a substitute for a manual push test of the alarm. Perform a button
test once per week to verify proper alarm operation.
SMOKE ALARM | DETECT SERIES | MODEL 20SAR

with slow smoldering fires) sooner than ionization alarms. Industry experts
recommend specific locations for smoke alarms, such as every level and Technical Specifications
sleeping area of the dwelling. The alarm can be installed on the surface of Model: 20SAR
any wall or ceiling following the UL/NFPA/Manufacturer’s recommended
Power Source: 120V AC, 60 Hz, with 2 AA battery backup
placement guidelines, on any standard single gang electrical box, up to a
4”octagon junction box. See User Guide for more location information and Smoke Sensor: Photoelectric
additional instructions. Audio Alarm: 85dB at 10ft
The alarm should be installed to comply with all local codes having
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
jurisdiction in your area, Article 760 of the National Electric Code, and NFPA
72. Make certain all alarms are wired to a single, continuous (non-switched) Humidity Range: Up to 95% relative humidity (RH), non-condensing
power line, which is not protected by a ground fault interrupter. A maximum Size: 5” W x 2” D x 5” H
of 1000 ft. of wire can be used in the interconnect system. Use standard UL Weight: 0.86 lb
listed household wire (18 gauge or larger as required by local codes).
Wiring: AC wiring, plug-in quick connector
A maximum of 24 Kidde devices can be interconnected in a multiple station
arrangement. The interconnect system must not exceed the NFPA (National Interconnects: Interconnects with up to 24 Kidde devices. Please
Fire Protection Association) limit of 18 initiating devices, of which 12 can be see User Guide for list of compatible alarms. This
smoke alarms. With 18 initiating devices (smoke, heat, CO, etc), interconnected, alarm is not designed to be interconnected with
it is still possible to interconnect 6 strobe lights and or relay modules. other manufacturer’s products, unless otherwise
specified.
Architectural & Engineering Specifications Warranty: 10-Year Limited Warranty (batteries excluded)
The alarm shall include a test button that will electronically simulate the
Replacement Batteries: Energizer E91, Gold Peak 15A or Golden Power
presence of smoke and cause the unit to go into alarm. This sequence
GLR6A. Replacement batteries are available
tests the unit’s electronics to ensure proper operation. The unit shall
where you purchased this alarm.
incorporate three LED colors. A green LED will be steady on when AC power
is connected, or flash every 60 seconds when in the battery only mode. An Note: Do not use lithium batteries in this unit.
amber LED will indicate fault conditions. A red LED will flash in sync with the
smoke alarm pattern, and will also indicate alarm memory.
The unit shall include the Hush™ feature that silences a smoke alarm
for approximately 8-10 minutes if a nuisance alarm condition occurs. The
red LED on the alarm will flash every 2 seconds while in Hush and will
automatically reset itself.
At the date of manufacture, the unit shall at a minimum meet the
requirements of UL 217, NFPA 72, NFPA 101 (One and two family dwellings),
Federal Housing Authority (FHA), and Housing and Urban Development (HUD).

NOTE: This is not a carbon monoxide (CO) alarm, but will receive and transmit a CO
alarm signal from an interconnected CO or combination smoke/CO alarm. The carbon
monoxide (CO) alarm pattern is four quick beeps repeating every 5 seconds. It is
impossible to determine the source of a co alarm using sight or smell. Always consider a
CO alarm event as dangerous.

Ordering Information
Ordering Case Dimensions
Number UPC GTIN Pack Config. Pack Qty ( D x W x H inches) Case Weight (lbs) Cartons/Pallet

21031482 047871314829 10047871314826 Box 6 15 x 6.3 x 6.06 5.56 108


21031484 047871314843 10047871314840 Box 2 15 x 6.3 x 6.06 5.4 108
21032826 047871328260 10047871328267 Box 3 15 x 6.3 x 6.06 5.44 108
21032827 047871328277 10047871328274 Box 2 19.76 x 6.30 x 6.06 7.01 84
21032828 047871328284 10047871328281 Box 1 14.17 x 5.91 x 5.98 4.85 114