DESCRIPTION CHARACTERISTICS SPECIFICATIONS
KEM LUSTRAL® Enamel is an air dry 60° Gloss: General: All substrates should be free of
enamel with excellent film characteristics for F65B50 < 10 mold release, oil, grease, dirt, fingerprints,
interior and exterior use. Its ease of All Other Bases High Gloss drawing compounds, surface passivation
application makes it ideal for product treatments and any other contaminants to
finishing and maintenance use. Volume Solids: 38 ± 2 % ensure optimum adhesion and coating
Varies by color performance. Consult Metal Preparation
Advantages: brochure CC-T1 for additional details.
• May be applied with a wide variety of Viscosity (at 77° F): 50-60 secs., #4 Zahn Cup
application equipment and methods. Aluminum: If untreated, prime with RoHS
Recommended Film Thickness: Compliant Wash Primer, P60G10 or
• Good color and gloss retention on
Mils Wet 3.5-4.5 Industrial Wash Primer, P60G2 or Kem
exterior exposure
Mils Dry 1.2-1.5 Aqua® Wash Primer, E61G522. Over "pre-
• Custom color capability by tinting
Phoenix® or GIS colorants. treated" aluminum, check adhesion before
Spreading Rate (no application loss): use as the proprietary pretreatment may
• Full gloss range available by using Gloss 374-548 ft.2/gal. at 1.2-1.5 mils DFT
Modifying Agent, D64F100 change from supplier to supplier which may
• USDA acceptance on many colors. have an effect on the final adhesion.
Cure:
Contact your Sherwin-Williams Air Dry or
Representative for listing For exterior use, prime with Kem-Flash®
Force Dry 60-90 mins. at 140-160° F
• Ideal for plant maintenance and color see product limitations Prime.
coding as safety colors
Drying: 1.2 mils at 77° F, 50% RH Wood: Must be clean, dry, and finish
To Touch 1.5 hours sanded. For exterior use, prime with A-100
Tack Free 3-4 hours Exterior Oil Stain Blocking Primer, Y24W20.
To Handle 5-6 hours
To Recoat - Spray after 9 hours
To Recoat - Brush after 16 hours
Flash Point: 102-105° F
(Pensky Martens Closed Cup)
Air Quality Data:
Non-Photochemically Reactive
Volatile Organic Compounds (VOC), Less Exempts,
Maximum
As supplied 4.2 lb/gal, 501 g/L
Reduced 25% with mineral spirits 4.6 lb/gal, 552 g/L
Recommended Storage: Inside, sealed
container, 40-120° F, no freeze hazard.
Protect from moisture.
Package Life: 3 years, unopened
Testing: The information, data, and
recommendations set forth in this Product
Data Sheet are based upon test results
believed to be reliable. However, due to the
* VOC Compliance limits vary from state to wide variety of substrates, substrate
state; please consult local Air Quality rules properties, surface preparation methods,
and regulations. equipment and tools, application methods,
and environments, the customer should test
An Environmental Data Sheet is available the complete system for adhesion,
from your local Sherwin-Williams facility or compatibility and performance prior to full
at www.PaintDocs.Com. scale application.
CC-B1 April/2023 continued on back
APPLICATION ADDITIONAL INFORMATION CAUTIONS
Typical Setups
1. Reds, Oranges, and Yellows contain FOR INDUSTRIAL SHOP APPLICATION
bleeding pigments. Caution should be ONLY
May be applied by: Brush, Dip, Roller exercised when recoating with products
Conventional Spray containing aromatic, ester, or ketone Thoroughly review the product label and
Airless Spray solvents. Using these colors for Safety Data Sheet (SDS) for safety
Electrostatic Spray intermixing may result in: information and cautions prior to using
A. Color walk-out or premature fading on this product.
Brush or Roller: Full Body, No Reduction exposure.
B. Bronzing (blooming on exposure to To obtain the most current version of the
Conventional Spray: light or heat, or if cured by force Environmental Data Sheet (EDS), Product
Reducer R1K3 (VM&P Naphtha) drying temperatures over 190° F). Data Sheet (PDS), or Safety Data Sheet
Reduction Rate up to 25% (vol.) 2. Reds, Oranges, and Yellows should not (SDS) please visit your local Sherwin-
be force dried at temperatures above 190° Williams facility or www.PaintDocs.Com.
Airless Spray: F.
Fluid Pressure 2,000 psi 3. All exterior recommendations for Please direct any questions or comments to
Tip 0.013-0.017 in. galvanized surfaces should be tested and your local Sherwin-Williams facility.
Reducer R1K3 (VM&P Naphtha) approved by the customer.
Reduction Rate up to 5% (vol.) 4. Compatible with GIS and Phoenix® Note:
colorants. All purchases of products from Sherwin-
Electrostatic Spray: 5. Do not use Blend-A-Color (BAC) Yellow Williams are exclusively subject to Sherwin-
Reducer For Polarity R6K10 (MEK) for exterior applications. Williams' Standard Terms And Conditions Of
Reduction Rate to 18-22 secs., #4 Zahn Cup Sale. Please review these terms and
conditions prior to the purchase of the
Equipment/application guidelines are only products.
guidelines and individual application &
process parameters will dictate exact Sherwin-Williams warrants the product to be
requirements. free of manufacturing defect in accordance
with Sherwin-Williams’ quality control
Cleanup: Clean tools/equipment procedures. Except for the preceding
immediately after use with R1K4 (Mineral sentence, due to factors that are outside of
Spirits). Sherwin-Williams’ control, including
substrate selection, and customer handling,
Follow manufacturer's safety preparation, and application, Sherwin-
recommendations when using any solvent. Williams cannot make any other warranties
related to the product or the performance of
the product. SHERWIN-WILLIAMS
DISCLAIMS ALL WARRANTIES OF ANY
KIND, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTY OF
MERCHANTABILITY, THE IMPLIED
WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE.
Liability for products proven to be defectively
manufactured will be limited solely to
replacement of the defective product or the
refund of the purchase price paid for the
defective product, as determined by Sherwin
-Williams. Under no circumstances shall
Sherwin-Williams be liable for indirect,
special, incidental or consequential
damages, lost profits or punitive damages
arising from any cause whatsoever.
All trademarks are the property of their
respective owners.
CC-B1 KEM LUSTRAL® Enamel