0% found this document useful (0 votes)
34 views198 pages

Camfil Products&Solution

Camfil specializes in air filtration products and solutions, established over 50 years ago to provide high-quality filters for various industries, including healthcare, power generation, and food safety. The company emphasizes environmental responsibility by designing filters that minimize waste and energy consumption while ensuring compliance with regulations. Camfil offers a wide range of products, including EPA, HEPA, and ULPA filters, as well as services for filter management and disposal.

Uploaded by

deepocean5162
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views198 pages

Camfil Products&Solution

Camfil specializes in air filtration products and solutions, established over 50 years ago to provide high-quality filters for various industries, including healthcare, power generation, and food safety. The company emphasizes environmental responsibility by designing filters that minimize waste and energy consumption while ensuring compliance with regulations. Camfil offers a wide range of products, including EPA, HEPA, and ULPA filters, as well as services for filter management and disposal.

Uploaded by

deepocean5162
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 198

AIR FILTRATION PRODUCTS

CLEAN AIR SOLUTIONS & SOLUTIONS


Information

Camfil air filtration products & solutions

Information

General Ventilation Filters


Over 50 years of
clean air solutions
EPA, HEPA & ULPA Filters
In 1960, Sweden is about to start its nuclear program.
Air filtration specialist Gösta Larson realizes that these
new power plants need air filters of better quality than
High Temperature Filters
ever before. Using low quality air filters in a nuclear plant
can quickly turn into a catastrophe. Gösta convinces the
nuclear engineers to start using top quality filters and Molecular Filters
quickly wins a business contract. In 1963, he builds his
first factory in Trosa, Sweden. Camfil is founded. Today,
with more than 50 years of experience, Camfil delivers Housings, Frames & Louvres
clean air solutions to customers and local markets
all over the world. With high quality products, we are
contributing to something that is essential to everyone – Air Cleaners & Air Purifiers
clean air for health, performance and well-being.

Turbomachinery Filters & Inlet Systems

Dust, Fume & Mist Collectors

FILTERS
L FOR EVERY
EVERY NEED

Comfort Power systems Containment


• Comfort Ventilation • Power Generation • Biosafety Labs
• Schools • Compressors • Nuclear
• Offices • Oil & Gas • Chem/Bio Protection

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
• Museums • Healthcare
• Airports

Industrial
Clean processes Air pollution control • Warehouses
• Life Science • Mining • Petrochemical
• Food • Metal Working • Foam Industry
• Microelectronics • Life Science/Pharmaceutical • Pulp & Paper
• Hospitals
Full version
Edition Nov 2020

2
Information

Index
Information EPA, HEPA & ULPA Filters CamHosp 2 131
CamFFU EC 132
Quick selection guide 4 Megalam ProSafe 67 CamFFU AC 133
Caring for the environment 5 Megalam Fabsafe 69 CamSafe 3 -Housing 134
Would you like to reduce your energy Megalam ES Fabsafe 70 CleanSeal Extract Exhaust/Return Air
outgoings? 6 Silent Hood 71 Housing 135
Indoor Air Quality (IAQ) 7 Absolute VGXL, VGXXL ProSafe 73 CamContain CS 136
Air Pollution and PM1 8 Absolute VEXL, VEXXL 74 CamCube HF-L 138
ISO 16890 9 Absolute VGXL ProSafe 75 CamCube AS 140
Comparison Chart 10 Absolute CE 76 Absolute Filter Holding Frame 142
Eurovent certified performance 11 Absolute CM 78 Universal filter holding frame 143
Energy efficiency classification 14 Absolute DE 80 FastFrame 144
CREO Software (Clean Room Energy Absolute DG 81 CamVane 100 145
Optimization) 15 Absolute VGHF 82 Dynavane 146
Public buildings 16
Automotive 17 High Temperature Filters Air Cleaners & Air Purifiers
Power systems 18
Sofilair HT 120-H13 84 City M Overview 148
Food and beverage 19
Airopac HT-HF 85 City M 150
Hospitals 20
Absolute 1FRSI 86 City Touch 151
Microelectronics 21
Absolute 1FRK-V 87 CC 410 (Concealed) 152
Life Science 22
Termikfil 2000 88 CC 1000 153
Explanation for symbols 23
Absolute D-Pyro 89 CC 1700 154
General Ventilation Filters CC 1700 Overview 155
Molecular Filters CC 2100 156
Ozone rating 26 CC 6000 157
Media Rolls 27 Applicable Standards for Corrosion CC 6000 Overview 158
Fan Coil Filters 28 Control 92 CC 6000 Overview (continued) 159
Media Holding Frame (MHF) 29 Application matrix 93
Hi-Cap ® 30 Why molecular filtration? 94 Turbomachinery Filters
Hi-Cap ProSafe 31 Molecular filtration technical services 95
Molecular filtration technical services 96 TurboBoost performance & The Value
Hi-Cap ® XLS 32
CamCarb PM 97 Rating for gas turbines 161
Hi-Flo XLT 33
CamCarb PM V 98 PowerEye & BoostToReduce 162
Hi-Flo XLS 34
CamCarb PC 99 30/30 GT 163
Hi-Flo M, P, TM 35
CamCarb XG 100 CamClose 164
Hi-Flo A, UF 36
CamCarb CG 101 CamClose Compact 165
City-Flo XL 37
CamCarb CM 102 Cam-Flo GT Hybrid 166
City-Flo 38
CamCarb Mounting Frames 103 CamGuard 167
Basic-Flo 39
CamCube CC-L 104 Hi-Cap GT 168
S-Flo A, P, U 41
CamCube HF-CC 106 CamPGT 169
Hi-Flo ProSafe 42
CamCarb VG 107 CamGT 4V-300 170
Aeropleat III 43
PSSA 108 CamGT 3V-440 171
30/30 ® 44
GigaPleat XPC 109 CamGT 3V-600 172
Dual10 45
GigaPleat XPH 110 CamGT Box Type G II 173
AP WR 46
GigaPleat NXPP 111 TurboPulse GTC10 174
CityPleat 47
GigaPleat NXPH 112 CamPulse GTC 175
ECO Moisture Separator 48
GigaPleat NXPC 113 CamPulse GT Polytech HE 176
EcoPleat G 49
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

GigaPleat NXDP (DH) 114 Tenkay 177


EcoPleat ProSafe 50
GigaPleat NXDP (PH) 115 Composite Filters Polytech Nano 178
Airopac ® Green 51
ProCarb VDBe 116 Composite Filters GTC (LM6000 Series)
Opakfil ES 52
HDB 116 179
Opakfil ProSafe ES 53
HDC 117 CamPulse CamBrane 180
Opakfil ST 54
ProCarb VDBs 117
Opakfil 2V 55 Dust, Fume & Mist Collectors
HDB Biogas 118
CityCarb I 56
Activated Carbon and Campure Media119
CitySorb 57 Gold Series® 182
CitySorb DP 58 Housings,Frames & Louvres Gold Series® Camtain® 183
Durafil ® ESB 59 Quad Pulse Package 184
Opakair 60 PHAP Pharmaseal AP 121 Quantum Series 185
Airopac ® 3GGM 61 PHAP® Exhaust AP 123 Handte Wet Scrubbers 186
Airopac ® 3GGMHF 62 Slimline RSR 124 Zephyr IIITM Portables 187
Riga-Flo 63 CleanSeal AP 125 Handte EM Profi 188
3CPM Aeropac 64 CleanSeal Top-C 127 Handte Oil Expert 189
3HCP8 Aeropac 65 CleanSeal Side-C 128 HemiPleat® Gold ConeTM 190
CleanSeal Side-R 129 Dura-Pleat® Gold Cone® 191
HemiPleat® Retrofit 192
Oval Retrofit 193
Explosion Protection Solutions 194

3
Information

Quick Selection Guide


Filter Grade Air Filter Selection

US EU GLOBAL

MERV 2 - 4 G2 ≥ 65%
Primary Filtration

Medium Efficiency

MERV 5 - 6 G3 ≥ 80%
ePM Coarse
Primary

MERV 7 - 9 G4 ≥ 90%
Arrestance
Average
Arrestance
ASHRAE 52.2 - 2017

ISO 16890 2016


ISO ePM10
EN 779:2012

MERV 10 M5 ≥ 40%
Medium

>50%
MERV 11 - 12 M6 ≥ 60% ISO ePM2.5
Conditioning Systems

50 - 60%
Filtration for Air

High Efficiency

MERV 13 F7 ≥ 80% ISO ePM1


50 - 70%
MERV 14 F8 ≥ 90% ISO ePM1
Fine

70 - 85%
MERV 15 F9 ≥ 95% ISO ePM1
Minimum Average >85%
Efficiency Efficiency
Reporting Value

DOP 0,3 um MPPS (Most penetrating Particle Size)


EPA

E10 ≥ 85%
Clean Room Filters

Very High Efficiency

≥ 95%
EN 1822:2009

E11 ≥ 95%
Final Filters/

≥ 99,9%
E12 ≥ 99,5%
HEPA

≥ 99,97%
H13 ≥ 99,95% As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

≥ 99,99%
H14 ≥ 99,995%
≥ 99,999%
U15 ≥ 99,9995%
ULPA

U16 ≥ 99,99995%
U17 ≥ 99,999995%
Molecular
Filter Holding
Frames and
Casings

4
Information

Caring for the environment


“How will your filters help you to reduce
the environmental impact of your
installations?”
Camfil has been involved in air quality for over 50 years, and
has to set an example when it comes to the environment.
It therefore has an obligation to provide its customers with
practical assistance on green issues. With regard to complying
with the law on waste disposal, Camfil is with you all the
way; in designing products and services, Camfil shares your
environmental concerns.

It is now widely acknowledged that air conditioning filters can


be considered ordinary industrial waste, whereas filters used
in environments containing potentially hazardous products
(e.g. return air from clean rooms, spray booths and operating Follow up CFM
theatres) should be considered special industrial waste and
Conscious of the increasing importance attached by our
must be disposed of by an approved route using accredited
customers to waste management, Camfil can support you and
systems.
take charge of replacing and organising the disposal of certain
Please Note - your individual circumstances depend entirely used filters as part of its CAMFIL FILTER MANAGEMENT (CFM)
on your processes and we recommend that you approach your programme. For more information and to find out whether this
usual waste disposal provider, who will be qualified to advise service might work for you, please contact us.
you on the matter.

In order to minimise waste, Camfil pay


close attention to the life cycle of the
product:
1. We make strenuous efforts to extend the lifespan of our
filters and to optimise their performance, which means that you
reduce your operating costs, the frequency with which you have
to replace the filters and the cost of their disposal.

Just look at the large filter surface used in many of our


products and remember large filter area is synonymous with
long filter life.

2. We favour the use of recyclable or incinerable materials.

3. We are continually researching effective materials with low


pressure loss, a parameter that has a direct influence on the
energy consumed during the lifetime of the filter.

4. The Green CAMFIL range ensures that you can dispose of

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
your used filters with less hassle and at lower cost. The use
of plastics or cardboard lends itself to the incineration of
used filters whilst ensuring compliance with all provisions of
environmental law.

5. We minimise the weight of materials used in the construction


of our filters which helps reduce the waste mass as far as
possible when the filter reaches the end of its life.

6. In our ISO 14001 certified factories, we are phasing out


the use of chloride solvents and hazardous products from our
processes.
Information

Would you like to reduce your energy outgoings?

Economic optimisation of air filtration


The price of crude oil has more than doubled in recent years
100
and the cost of electricity is rising throughout the world. The
World Bank’s Energy Group has predicted that total energy
consumption is set to rise at the current rate for at least the
80
next 50 years.
70
The cost of ventilation
Ventilating buildings, as we know, can be a very expensive 60
business. The average energy cost of filters is around 30%
of the total costs of the system. By choosing the right filter,
for example the ePM1 60% for its efficiency and its very low 40
average pressure loss, energy savings can be made whilst
maintaining a high level of IAQ. When you consider that the
air filter is the most inexpensive and simplest component to 15 20
change, savings can be made quickly. 8 5 2 %

l
gy

ng

ur

sa
lte

bo
er

ni

po
Fi
En

ea

La

is
Cl

D
Choosing the right filter saves energy
In order to optimise the lifespan of the filter and to reduce
energy consumption, it is important to bear in mind the extent
to which their configuration and their structure influence the
average pressure loss.

Energy
Tapered pockets
s
ts

rs

ils

rs

ns
er

er

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Parallel pockets
uc

lte

te
co

tio
ng

nc
ea
D

Fi

ec
g

le
ha

H
in

nn
Si
xc

ol

Co
te

Co
ea
H

Typical pressure loss (Pa) in a ventilation system with 2 stage filtration Blocked surface = high energy consumption

1Pa = 1 euro Software aimed at helping select the right


A rule of thumb, for a typical installation running for half of filter = optimising energy costs
the time over one year, is that one additional Pascal in pressure For over 50 years, Camfil has played a pioneering role in
drop adds 1 euro per filter in extra energy cost. designing filters with low average pressure loss for all efficiency
A badly designed filter construction could add 50 Pascal levels for air conditioning and ventilation systems. Camfil was
compared to a well engineered filter, even if it claims to have the first filter manufacturer to develop sophisticated software
the same efficiency. In other words it adds 50 euros to the that calculates the overall cost for the complete life cycle of air
annual energy bill, for every filter. filters. As part of our continuous improvement, this software
has evolved over time and it uses real life data collected from
70% of the total cost comes from energy numerous tests in real use conditions. This enables us to
calculate the pressure loss of the filter and its actual lifespan,
costs rather than relying on theoretical calculations.
Calculations show that energy normally accounts for 70%
For more information and assistance, please contact your
of the total cost of the life cycle of an air treatment system.
nearest branch of Camfil.
Energy consumption is in direct proportion to the filter’s
average pressure loss.
Information

Indoor Air Quality (IAQ)


Environmental Health
Environmental health is becoming a central concern at national
and international levels. Indoor Air Quality (IAQ) is an area
that focuses on providing a comfortable and healthy indoor
environment which is important to the well being of people.
We spend 90% of our time in indoor spaces and, as such, the
issue of IAQ is a key aspect of public health, especially since
this affects the entire population, particularly the most sensitive
and vulnerable.
The industrialised world is a very different place compared to
50 years ago and one major difference is that the air we breathe
is now more heavily and more diversely polluted than at any
time in the past. Although natural sources of pollution exist,
the greater concerns arise as a result of mans own activities
which have increased both the amount and the complexity
of pollutants found in the atmosphere. There are tens of
thousands of synthetic chemicals (not found in nature) made
today with an estimated annual production rate in excess of a
billion tonnes. These chemicals are released to the atmosphere Secondary pollutants
during manufacture use and can subsequently travel vast Secondary pollutants are substances whose presence in
distances. They are an inevitable part of our lives. the atmosphere is the result of chemical transformations
related to the interaction of compounds known as precursors.
Ozone is the main secondary pollutant, it is formed as a
result of a photochemical process in the presence of certain
primary pollutants (carbon monoxide, nitric oxide and volatile
organic compounds). This is a gas that is naturally present
in the atmosphere in low concentrations at high altitude.
At low altitude, on the other hand, the development of the
concentration is primarily the result of human activity.
Sulphuric acid and nitric acid form in the atmosphere as a result
of humidity from sulphur dioxide and nitric oxide respectively.

Solid pollutants
Solid pollutants usually in the form of small (fine) particles
are very important and from a cleanliness point of view, these
particles deserve particular attention. These are capable of
acting as vectors to other substances, such as carcinogenic
polycyclic aromatic hydrocarbons, which is particularly worrying
given the capacity of the finest particles (< 1μm) to find their
way into the lungs and even to penetrate into the bloodstream.
Effective solutions aimed at combating such particle pollution
Atmospheric pollution are now widely known. The development of the main standards

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
and recommendations governing the manufacture and use
Atmospheric pollution can be categorised in two different ways.
of modern air filters is clearly geared towards much higher
The simplest is measurement (a physical categorisation) to
filtration levels than have been permitted in the past
distinguish gaseous pollutants from solid, dust and particulate
pollutants. The second is based on the origin of pollutants and
City
is divided into primary and secondary pollutants.
Our range of ‘City’ filters has been developed with the sole
Primary pollutants purpose of combating atmospheric pollution and its major
components.
Primary pollutants are substances present in the atmosphere,
in the form in which they are emitted. Of these pollutants, some CityCarb and City-Flo combine particulate filtration with
are especially prominent: pollution and odour filtration. They are suitable for any new
Sulphur dioxide (SO2) emitted by certain industrial processes, installation and can be readily installed to upgrade and improve
such as paper-making and refining, and in particular by the use systems currently equipped with standard filters.
of sulphurous fossil fuels. SO2 is one of the main causes of acid
With its higher molecular adsorption, CitySorb is ideal for
rain on account of its transformation in the atmosphere into
highly polluted urban environments. CitySorb must be fitted in
sulphuric acid (H2SO4). Nitric oxides (NOX), and in particular
conjunction with a particulate filter above ePM1 50% efficiency,
nitrogen dioxide (NO2), which is usually emitted from the
Hi-Flo or Opakfil type.
burning of fossil fuels (particularly vehicles), contribute towards
the formation of ozone in the atmosphere. Polycyclic aromatic
hydrocarbons are emitted by the incomplete burning of fuels
or carbon, which can usually be found in the air, linked to
particles. Some of them are known to be highly carcinogenic.
Information | Standards

Air Pollution and PM1


Air pollution has been assessed to be 4th highest risk factor to mutations in human DNA which can lead to cancers. This
human health and by far the most serious environmental risk . behaviour is known as mutagenicity. PAH can exist as particles
Air pollution includes particulate matter (PM). We identify both or in the molecular form, but often they are found condensed
man-made sources such as vehicle exhaust, construction and onto the surface of PM1, particles smaller than 1 micron. In
power generation alongside natural sources such as pollen, this study four different air filtration medias (corresponding to
forest fires and windblown sand and soil. Particulate matter M6, F7 [x2] and F9 acc. EN779:2012) were assessed in respect
from man-made sources, especially combustion processes, of their ability to:
tends to be at the small end of the size range and often
1. Remove fine particles (0.4 micron) according to method
these particles are released into the air near centres of high
EN779:2012
population density, i.e. cities.
2. Reduce the level of PAH in urban air.
Many governments and NGOs publish pollution data in real 3. Reduce the mutagenicity of urban air.
time on websites. The most commonly reported values relate to
particle fractions PM2.5 and PM10. In 2005 the World health
The study concluded that:
Organisation (WHO) published air quality guidelines (AQG)
which included recommendations for exposure limits to PM2.5 A.The PAH content of urban air was progressively reduced by
and PM10. passing the air through filter media of increasing efficiency
between M6, F7 and F9. When the reduction in PAH was
Recently there has been a shift in focus towards a smaller
plotted against the efficiency of the filters in removing 0.4
particle fraction, PM1. This is all particles sized 1 micron
micron sized particles (EN779:2012 results), the relationship
and less. A micron is one thousandth of a millimetre. There
was linear.
is a growing body of evidence from the scientific and medical
communities that it is the very small particles that we breathe
that are most hazardous. By number, particulate matter is very B. The mutagenicity of urban air was progressively reduced
much biased towards particles less than 1 micron in size. by passing the air through filter media of increasing efficiency
between M6, F7 and F9. When the reduction in mutagenicity
The body has some natural defences against larger particles
was plotted against the efficiency of the filters in removing 0.4
such as the nasal hairs and mucas membranes. However these
micron sized particles (EN779:2012 results), the relationship
are not so effective for smaller particles and potentially they are
was linear.
able to reach the lungs. Fine particles, less than 1 micron are
able to penetrate into the important fine structure of the lungs,
the alveoli. Extremely fine particles, so called ultra-fines and C.There is a direct relationship between the removal of 18
nano particles are able to pass through the alveoli and enter the common PAHs and the reduction of mutagenicity of urban air.
bloodstream when they are distributed around the entire body D.The observed results support the theory that a significant
and reach critical organs such as the brain, heart, liver and proportion of airborne PAHs are bound to very small particles;
endocrine system. PM1, and highly efficient filters are required to effectively
reduce their concentration in air.
A study published by UK researchers in 2016 reported that
ultrafine metallic particles (<0.1 micron) had been found in So, the hazard from breathing very fine particles, PM1 is clear.
the human brain and these have been linked to the onset of There is a new global standard for the testing and classification
Alzheimer’s Disease. These metallic particles appeared to have of air filters. To afford maximum protection against these
been exposed to high temperatures and it is concluded that hazardous pollutants, Camfil strongly recommend the use of
they originated in the combustion cycle of diesel engines. ePM1 rated filters according to IS016890.
Camfil were involved in another study published in 2016.
Polyaromatic hydrocarbons (PAH) are a group of chemicals that
are released into the air when petrol, diesel, coal, wood and
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

other organic materials are combusted. PAH are characterised


by their toxicity including the ability to be capable of causing

1
Professor Michael Brauer. University of British Columbia, School of Population and Public Health, Vancouver, Canada.
2
Prof David Allsop et al. Proceedings of the National Academy of Sciences, Sept. 2016.

Removal of polycyclic aromatic hydrocarbons and genotoxic compounds in urban air using air filter materials for mechanical ventilation in buildings”
3“

by Ioannis Sadiktsis1, Gertrud Nilsson2,3, Ulf Johansson2, Ulf Rannug3 and Roger Westerholm1. Published in ASHRAE’s research
publication Science and Technology for the Built Environment, February 2016
Information | Standards

ISO 16890
Camfil welcome the publication of a new ISO standard for the European norm was withdrawn in 2018. It is obvious that it
testing and classification of air filters used in general ventilation would be beneficial if ISO16890 also replaced ASHRAE 52.2.
systems. Importantly, ISO16890 has global applicability and Whilst this could happen in the future, the time scale is not yet
will ultimately be applied in all our markets. After a period clearly defined..
of coexistence, ISO16890 fully replaced EN779:2012 and the

Benefits of ISO16890

For specifiers, purchasers and users of air filters For the filter industry
The standard recognises that air filters positively influence indoor It will be easier to compare products. This will drive innovation
air quality and human health. and customer value. Very poor performing products may be elimi-
nated.
The test method and filter classification system are better aligned Easier to explain product value in terms of function and cus-
with real-world pollution. tomer application.
The global applicability will eliminate confusion that occurred This standard will remove an obstacle to global trade.
when attempts were made to compare results of EN779 and
ASHRAE 52.2 tests.

How ISO16890 compares to EN779:2012 and ASHRAE 52.2.

EN779:2012 ASHRAE 52.2 ISO16890


Filter test method Efficiency measurement made using Efficiency measurements made Efficiency measurements made
0,4μm particles using 0,3- 10 μm particles. using 0,3- 10 μm particles.
Classifications relate to re- Classifications relate to result for
sults for E1, E2 & E3 efficiency PM1, PM2.5 & PM10
classes - MERV rating
Discharging method Discharge only filter media, using Discharge entire filter Discharge entire filter
IPA soak. using KCL salt. using IPA vapor.
A tough discharging method. A soft discharging method. A tough discharging method
Discharge is not mandatory -
may be applied as Appendix J
procedure.
Filter loading method Dust loading with ASHRAE dust. Dust loading with ASHRAE dust. Dust loading with ISO fine dust.
Coarse dust. Coarse dust. Fine dust (more like real-world).
Classification system 9 Classes 16 Classes 49 Classes
In 4 different groups

ISO16890: Overview of Classification System

Group Designation Requirement Class reporting value


ePM1, min ePM2.5, min ePM10
ISO Coarse - - <50% Initial gravimetric ar-
restance

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
ISO ePM10 - - >/=50% ePM10
ISO ePM2.5 - >/=50% - ePM2.5
ISO ePM1 >/=50% - - ePM1

ISO16890: Classification Table

PM1 Classification PM2.5 Classification PM10 Classification Coarse


ePM1 95% ePM2.5 95% ePM10 95% Arrestance reported in 5%
ePM1 90% ePM2.5 90% ePM10 90%
ePM1 85% ePM2.5 85% ePM10 85%
ePM1 80% ePM2.5 80% ePM10 80%
ePM1 75% ePM2.5 75% ePM10 75%
ePM1 70% ePM2.5 70% ePM10 70%
ePM1 65% ePM2.5 65% ePM10 65%
ePM1 60% ePM2.5 60% ePM10 60%
ePM1 55% ePM2.5 55% ePM10 55%
ePM1 50% ePM2.5 50% ePM10 50%
Requirement: Requirement: Requirement: No discharge requirement
>50% initial efficiency >50% initial efficiency >50% initial efficiency
>50% discharged efficiency >50% discharged efficiency No discharge requirement
Note: ISO16890 demands a minimum (discharged efficiency) of 50% for ePM1 and ePM2.5 rated filters. This will ensure that those
filters always provide a decent standard of long-term filtration in real-world customer applications.
Information

Comparison Chart
ASHRAE 52.2, EN779:2012 and ISO16890

TYPICAL EFFICIENCIES OF AIR FILTERS AGAINST PM1 AND OTHER FINE DUST MASS CONCENTRATIONS

EN779:2012 / EN ISO 16890 ISO ePM1 ISO ePM2.5 ISO ePM10

M5 ≥50%

M6 ≥50% ≥60%

F7 ≥50% ≥70% ≥80%

F8 ≥70% ≥80% ≥90%

F9 ≥80% ≥90% ≥95%

ASHRAE 52.2 – TYPICAL EFFICIENCIES OF AIR FILTERS AGAINST PM1 AND OTHER FINE DUST MASS CONCENTRATIONS
ASHRAE 52.2 / EN ISO 16890 ISO ePM1 ISO ePM2.5 ISO ePM10

MERV 10 (10-A) ≥50%

MERV 11 (11-A) ≥50% ≥60%

MERV 13 (13-A) ≥50% ≥70% ≥80%

MERV 14 (14-A) ≥70% ≥80% ≥90%

MERV 15 (15-A) ≥80% ≥90% ≥95%


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Information

Eurovent certified performance


Read more on Eurovent Certita’s website: www.eurovent-
certification.com

Eurovent Certita’s certification of our fine-dust filters


means that you can rest assured that we live up to the
performance requirements and the data we print in our official
documentation. Our fine-dust filters are tested by independent
laboratories selected by Eurovent Certita and that means
security for you. Select Camfil air filters with Eurovent Certita
certification - its guaranteed!
ISO rating

ISO ePM1 60%

Independent test results


Our Eurovent Certita certification covers bag filters, compact
filters and panel filters in classes ePM1, ePM2,5 and
ePM10, tested to EN ISO16890:2016. The initial pressure
drop must remain within the tolerance levels set out in EN
ISO16890:2016.*

All filters that we officially market in brochures or on our


website in these filter classes are covered by the certification.
Each class contains a range of product groups:

• Same filter media/material (such as fibreglass)


Air filter certification - you can count on • Same basic design (such as bag filters, compact
filters etc)
us! • Same or lower air speed/net filter area
Camfil, in conjunction with the main independent test • Same filter class: ePM10, ePM2,5 and ePM1
laboratories in Europe, is committed to bringing you the highest
• Published data must be available, specifying the
levels of transparency with regard to the new test protocols for
model, type, filter material, filter class as per EN
air filters. ISO16890:2016,
The European Committee for Standardisation has recently • Nominal airflow and initial pressure drop at nominal
published a new standard on “Particulate air filters for airflow.
general ventilation - determination of filtration performance”. The filters are tested at independent test laboratories - in
One of the aims of this new standard is to detail the in-situ Sweden, the Research Institute, RISE, in Borås; in Finland,
performance of an air filter. VTT in Espoo and CETIAT France in Lyon. These are the only
laboratories in Europe that are accredited to ISO 17025.
This new test protocol provides accurate data on the
effectiveness of your air filters operating under real life The test laboratories are not told which company’s products

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
conditions. Please always specify filters tested in accordance they are testing, but are only given a number that Eurovent
with EN ISO16890:2016. Your Camfil representative is available assigns to each individual filter.
to explain this standard in detail should you require it - you can *)
Tolerance levels for initial pressure drop defined in
count on us!
EN ISO16890:2016: +(10%+Mt) or +(10Pa+Mt), whichever is
Air filter performance highest. Mt = 5Pa (tolerance level defined in
EN ISO16890:2016)
At Camfil we are going a step further to ensure the best
possible performance for our customers. The European
ventilation industry organisation Eurovent Certita has developed
a certification programme to guarantee that our products live
up to our promises.

The key elements of the programme are that:


• Published data must be correct
• The products must comply with the EN
ISO16890:2016 standard
• Filters must be tested by independent laboratories -
RISE in Sweden, VTT in Finland and CETIAT in France
• The test laboratories must be ISO 17025 certified
• We as manufacturers must be quality certified to ISO
9000 or a corresponding standard
• Each year, Eurovent Certita selects, at random, four
new filters from our range for inspection

1
Information

Energy efficiency classification


The way of comparing air filters.
At last, buyers of air filters will find it a lot easier to find
the right filter– regarding both energy efficiency and indoor
air quality. With the implementation of Eurovent Certita´s
updated and objective system for classifying energy efficiency,
it will be easier to find the right air filter for the lowest energy
usage and highest indoor air quality. All air filters can be
graded from A+ to E. Grade A+ stands for the lowest energy
consumption and E for the highest. The classification, based
on the filter test method EN ISO16890:2016, will give buyers a
better understanding of annual energy consumption, average
efficiency and minimum efficicency. The energy consumption
of air filters in general ventilation systems has become the
focus of attention as energy prices increase, and as demands to
reduce CO2 emissions get tougher.

The standard.
The energy consumption of air filters can be determined
as a function of the volume flow rate, the fan efficiency, the
operation time and the average pressure drop. Due to the dust
loading during operation, the pressure drop of an air filter is
constantly increasing. The related energy consumption during
a certain period of time can be calculated from the integral
average of the pressure drop over this period of time.

Put your supplier to the test.


Many suppliers do not test their filters properly, making it
impossible for customers to compare different brands. At
Camfil, we test all our filters to guarantee a high standard of
quality. Does your air filter supplier have what it takes?

• Is the supplier certified by Eurovent Certita?


• Are there labels on all boxes? Calculation and classification.
• Are all tests based on EN ISO16890:2016?
The standard measures both filtration efficiency and pressure
• Is there a test protocol for validation? drop as a function of dust loading. A representative energy
consumption level is calculated using the mean pressure drop
difference averaged over the course of dust loading. On the
basis of these figures, the energy performance of a filter over
an operating period of one year is simulated in a laboratory.
This representative energy value is used for a classification of
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

air filters into energy classes.

Calculation and Energy Classification


The energy use in kWh/annum is calculated due to the formula in Eurovent REC 4/21-2018.

Where we define qv = 0.944 m3/s, t = 6000 h/a and h = 0.5

1
Information

Annual energy use for filter classes


Eurovent Certita rules allow only 1% A+, 5% A, 15% B, and 30% C class filters in Europe.
Update of Eurovent Energy Rating every 3 years.

Mx = 200 g
(AC Fine) AEC in kWh/y FOR ePM1 (ePM1 and ePM1,min ≥ 50%)

A+ A B C D E

50 & 55% 800 900 1050 1400 2000 >2000

60 & 65% 850 950 1100 1450 2050 >2050

70 & 75% 950 1100 1250 1550 2150 >2150

80 % 85% 1050 1250 1450 1800 2400 >2400


> 90% 1200 1400 1550 1900 2500 >2500

Mx = 250 g
AEC in kWh/y FOR ePM2.5 (ePM2.5 and ePM2.5,min ≥ 50%)
(AC Fine)

A+ A B C D E

50 & 55% 700 800 950 1300 1900 >1900

60 & 65% 750 850 1000 1350 1950 >1950

70 & 75% 800 900 1050 1400 2000 >2000

80 % 85% 900 1000 1200 1500 2100 >2100


> 90% 1000 1100 1300 1600 2200 >2200

Mx = 400 g
AEC in kWh/y FOR ePM10 (ePM10≥ 50%)
(AC Fine)

A+ A B C D E

50 & 55% 450 550 650 750 1100 >1100

60 & 65% 500 600 700 850 1200 >1200

70 & 75% 600 700 800 900 1300 >1300

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
80 % 85% 700 800 900 1000 1400 >1400
> 90% 800 900 1050 1400 1500 >1500

1
Information

Energy efficiency classification

ENERGY EFFICIENCY ENERGY EFFICIENCY

CAMFIL CAMFIL
Opakfil ES 7 – ISO ePM1 60% A+ Opakfil ES 7 – ISO ePM1 60% A+

ISO ePM1 60% ISO ePM1 60%


EN-ISO16890-1:2016 EN-ISO16890-1:2016

Nominal airflow: 0.944 m3 /s


Efficiency: ePM1 61 %
Minimum efficiency: ePM1 min 61 %
Annual Energy Consumption: 838 kWh/annum

2019 2019

Eurovent Energy Efficiency label Other ”family sizes” acc. to EN15805,


The new labeling system will be displayed on standard filter Eurovent OM-11-2019 and RS 4/C/001-
boxes.
2019
There are two different ways of exercusion.
2. Other ”family” sizes according to EN15805, *Eurovent OM-
11-2019 and RS 4/C/001-2019
Full size 592x592mm, acc. to EN15805
- Energy class only, as 592x592 certified dimension
1. Full size 592x592 mm, according to EN 15805
- Nominal air flow rate, 3400 m3/h
- Efficiency, (average of initial and discharged) Front dimension
- Minimum efficiency (discharged)
Width Height
- Annual Energy Consumption, kWh/annum
490 592
- Energy class
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

287 592

592 287
Certified values are to be find at:
490 287
Certified values are to be find at: www.eurovent-certification.
287 287
com

592 490*

490 490*

592 892*

490 892*

287 892*

1
Information

CREO Software (Clean Room Energy Optimization)

An overview of Camfil CREO Software


• Clean room theory and design • Latest clean room standards
• Human particle generation calculations • Cleanliness Classification Report
• LCC (Life Cycle Cost) calculations • Total Cost of Ownership Reports
• Steady state condition calculations for various designs • Specification Generator
• Air handling system design specific to the selection of air filters

Clean Room Classification Report with Steady State calculation.


Clean rooms play a vital role in multiple industries, supporting
product innovation and the latest developments in cutting-edge
technologies. They are also extremely challenging to design,
with very high demands for air cleanliness and an increasing
demand from owners and operators to reduce escalating
energy costs. As the air cleanliness level is dependent on
various factors - the room’s supply air, contamination sources,
and the design of the ventilation system - sophisticated
computer-aided analysis is often better suited to estimate
cleanliness, and ensure that users end up with the facilities
their application requires.

Output summary

Key features of CREO


CREO software features a unique up-to-date simulation engine
based on clean-room theory and design. Users calculate human
particle generation, perform calculations of steady-state
conditions for different designs, and select the appropriate air
handling system design and air filters. As reference, CREO also
contains the latest clean room standards for the life sciences
and microelectronic industries, including comparisons between
ASHRAE and ISO 16890.

CREO is a very quick and accurate tool for designers to


select the required filters. Comparison up to three different
solutions can be obtained with just a few inputs. The end result
is customized clean room application that also allows the
user to calculate the life cycle cost and cleanliness class for
different clean room configurations and optimize their energy
consumption.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Clean Room Classification Report with Steady State calculation
Outputs, in standard file format, from CREO are:
Camfil, the world’s leading provider of air filters is widely • TCO Executive Summary
recognized as the leading clean air solutions supplier globally.
• Steady State Calculation Report
In another industry first, they have released this new software
to support end users and designers to optimize air filtration • Complete and Detailed TCO Calculation Report for all
selection for the most sustainable clean rooms: System Components
• Extensive Engineering Specifications

For further information and software simulation, contact your


nearest Camfil office or representative.

1
Information | Recommendation

Public buildings
Camfil ventilation filters prevent airborne particles from reducing air flow volumes in HVAC systems. During their lifetime, these filters keep air-handling
systems clean so they can perform in accordance with design parameters.

These same filters also help safeguard people’s wellbeing and health. Camfil’s comfort air filters are commonly used in for example office buildings, schools,
conference centres, shopping malls.

1 or 2 3 or 4

5 5

5
5

3 or 5

5
5

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Hi-Flo XLT 2. Opakfil ES 3. CityCarb 4. City-Flo 5. Ecopleat


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1
Information | Recommendation

Automotive
Few industrial applications demand such a clean working environment as paint facilities. Paint spraying facilities require a constant supply of fresh air for
hygiene and safety reasons. We currently provide clean air and services to many major automotive plants throughout the world. We provide the best possible
cost effective clean air solutions, customized and performance-optimized to meet your demands. Supplied and delivered exactly according to your needs
– with Camfil.

6, 7, 1, 2, 3 6, 7, 1, 2, 3 6, 7, 1, 2, 3 6, 7, 1, 2, 3

4
5

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Hi-Flo XLT 2. S-Flo 3. Opakfil ES 4. Airopac HT/Panolair HT 5. CDM-600

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6. 30/30 7. Hi-Cap

1
Information | Recommendation

Power systems
Clean air is vital to all combustion processes. The prime function of an inlet filter system is to protect the gas turbine from pollutants in the air, as
particles entering can cause costly damages like erosion, corrosion and fouling. Erosion is a permanent degradation, mainly caused by coarse particles,
while corrosion is caused by salt in combination with sulphur, and high temperatures. Smaller particles cause fouling of turbine blades, and thus affecting
performance negatively. A secondary effect is an increase in temperatures, as heat transfer effectiveness is reduced, and ultimately the life of the hot
section. Effective capture of particulate and airborne salt is therefore of vital importance for long and efficient operation. If not removed by the inlet
system, particles will force operators to more frequently water wash the compressor, either by unnecessary on-line washing or during costly shut downs.

It is also important to understand the complexity of differentiating air filters. Most air filters remain in a system for months or even years. During this time,
the filter will experience several environmental variations like changes in temperature, humidity, airflow velocity and particle load. To prevent this, and
make sure our filters withstand the severe real life conditions once in operation; all GT filters are being developed and tested both at our own brand new
Tech center, or at a third party company. For your best choice and solution, please contact your local Camfil-office for consultation, recommendation and
calculation.

1 5 6
4 4
2 3 7 8

These are general recommendations for gas turbine air inlet systems. For consultation and details, please contact your nearest Camfil office.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1. CamVane 100 2. CamClose 3. Cam-Flo XMGT 4. CamGT 5. Cam-Flo GT /


CamGuard

6. CamPulse GTC/GTD 7. CamPulse CamBrane 8. Tenkay

1
Information | Recommendation

Food and beverage


Beverages protecting human health is a major concern for governments throughout the world. In France, for instance, the National Agency for Food Health
and Safety (AFSSAL) can recommend to the authorities that the requisite health policy measures be taken. To prevent the air conditioning system from
becoming a microbe nest, temperature and humidity must be controlled and accumulated organic matter removed, as clogged exchangers provide good
support for the development of microorganisms. Talk with the experts in Clean air solutions – Camfil.

1 2

3, 4 2
5, 6

7, 8

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Opakfil ProSafe F7 2. Opakfil ProSafe F8 3. Absolute VG 4. Slimline RSR 5. CleanSeal AP

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6. Silenthood 7. 30/30 8. Ecopleat

1
Information | Recommendation

Hospitals
Nowhere is air filtration more important than in health care facilities. Air filters offer excellent protection from airborne diseases in health care facilities,
provided they form part of an overall air quality control programme. Camfil superior components include air filters, air filter housings or holding frames, air
changes supplied to the conditioned space, temperature and humidity control, outside air introduction and appropriate control of air flow to protect visitors
from undue exposure.

2
1

3, 4
5, 6 5, 6

6, 8

7, 9 7, 9

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Hi-Flo XLT F7/F8 2. Opakfil ES 3. Absolute DG 4. Slimline RSR 5. CleanSeal


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6. Megalam MD14 7. Ecopleat 8. CleanSeal AP 9. CamSafe


Information | Recommendation

Microelectronics
Advanced production methods often require very clean air, and in many cases these requirements are certain to increase. Camfil is recognized as the leading
supplier of high efficiency filtration products for the microelectronics industry. HEPA/ULPA filters are produced within controlled environments in our ISO
9000-certified plants. Our large production capacity ensures the availability of our products at all times throughout the world.

1, 2 2, 3, 4

4, 5

7, 8 6, 8 1, 2 or 3
7, 8
1, 2

8 8 8

2, 3, 4 4, 5 4, 5

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Hi-Flo F7/F8 2. Opakfil ES 3. Camcarb 4. Absolute V 5. Gigapleat

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6. Silent Hood 7. Megalam FabSafe 8. Gigapleat NXPP

2
Information | Recommendation

Life Science
For the past forty years we have been a leading supplier of air filtration products and services to the Bio-Pharma Industry. Many of our clients have multiple
facilities located around the world. Camfil is viewed by many of the largest Pharmaceutical manufacturers as a partner and well positioned to support their
air filtration demands on a local and global basis.

1 2 3, 12

6, 8 7, 8, 9 4, 5

3, 10, 11 8
3, 11, 13

These recommendations are based upon existing criterion as published by cognizant authorities, or best practice, based upon published data. For your
specific application, contact Camfil for a detailed solution for your needs.

1. Hi-Flo ProSafe F7 2. Opakfil ProSafe 3. Absolute VG XL 4. Absolute DG 5. Megalam MX, MG


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6. CleanSeal AP 7. Pharmaseal AP 8. Pharmaseal Exhaust AP 9. CleanSeal 10. Camsafe

11. Airopac/Opakaire 12. FCBL-A Classe C 13. Ecopleat

2
Information | Recommendation

Explanation for symbols

EFFICIENCY GUARANTEE

Low Pressure Efficiency Mount with the


Molecular 2 in 1 Media High Airflows
Drop Guarantee pockets Vertical

STED T I F I C AT TES
TED STED
TE ER TE

EN EN
E
C

779:2012 1822 ISO10121 ISO16890


AC C O R D I N G INDIVIDUALLY AC C OR DI N G ACCORDING
TO CERT IFIED TO TO

Test Standard Test Standard Test Standard Test Standard LCC Optimized IAQ Public Build-
EN779:2012 EN1822 ISO10121 ISO16890 (Lifecycle Optimized) ings

CREO
Air

MagiCAD
lt e
se

s ®
ce

rs
for o
s e n s iti v e p r

MagiCad
Prosafe Fabsafe Haze Free UL 900 CREO Approved
Certified

Ozone 3 Ozone 5 Ozone 6 Ozone 7 Ozone 8 Ozone 9

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Allergy friendly A+ Eurovent FM APPROVED


Singapore Green MyHIJAU
Quality Tested Energy
Building Product
Classification

Gasket Position: Gasket_01_10 Eurovent Certification Gasket Position: Gasket_01_00_10

2
General Ventilation Filters

Products

Pre-Filtration Pre-Filtration Pre-Filtration Bag Filters


Media Rolls Fan Coil Filters Media Holding Frame (MHF) Hi-Cap ®
Page 27 Page 28 Page 29 Page 30

Bag Filters Bag Filters Bag Filters Bag Filters


Hi-Cap ProSafe Hi-Cap ® XLS Hi-Flo XLT Hi-Flo XLS
Page 31 Page 32 Page 33 Page 34

Bag Filters Bag Filters Bag Filters Bag Filters


Hi-Flo M, P, TM Hi-Flo A, UF City-Flo XL City-Flo
Page 35 Page 36 Page 37 Page 38
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

Bag Filters Bag Filters Bag Filters Pleated Panel Filters


Basic-Flo S-Flo A, P, U Hi-Flo ProSafe Aeropleat III
Page 39 Page 41 Page 42 Page 43

Pleated Panel Filters Pleated Panel Filters Pleated Panel Filters Pleated Panel Filters
30/30 ® Dual10 AP WR CityPleat
Page 44 Page 45 Page 46 Page 47

24
General Ventilation Filters

Pleated Panel Filters Pleated Panel Filters Pleated Panel Filters Pleated Panel Filters
ECO Moisture Separator EcoPleat G EcoPleat ProSafe Airopac ® Green
Page 48 Page 49 Page 50 Page 51

Compact Filters (Header Compact Filters (Header Compact Filters (Header Compact Filters (Header
Frame) Frame) Frame) Frame)
Opakfil ES Opakfil ProSafe ES Opakfil ST Opakfil 2V
Page 52 Page 53 Page 54 Page 55

ePM2,5

Compact Filters (Header Compact Filters (Header Compact Filters (Header Compact Filters (Header
Frame) Frame) Frame) Frame)
CityCarb I CitySorb CitySorb DP Durafil ® ESB
Page 56 Page 57 Page 58 Page 59

As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type)
Opakair Airopac ® 3GGM Airopac ® 3GGMHF Riga-Flo
Page 60 Page 61 Page 62 Page 63

Compact Filters (Box Type) Compact Filters (Box Type)


3CPM Aeropac 3HCP8 Aeropac
Page 64 Page 65

2
General Ventilation Filters | Information

Ozone rating
Removing ozone from the air
Molecular filters reduce ozone levels in the air through
processes of adsorption and decomposition.

Measuring ozone removal efficiency


Camfil use a unique test rig to measure ozone removal
efficiency. Temperature and relative humidity conditioned air
is blown through full size production filters. Ozone is injected
into the airstream and sensitive ozone detectors measure the
concentration upstream and downstream of the filter. Filter
efficiency is readily calculated from the up-and downstream
ozone concentrations.

Camfil are market leaders in the validation of performance of


molecular filters. Filters can be challenged with many different
gases and vapours. Using temperatures between 5 and 50 deg
C and relative humidity values between 30% and 90%, we can
determine the performance of our filters under the conditions
present in our customer applications.

Camfil introduce an ozone removal


efficiency classification for molecular
filters.
Table of ozone filtration ratings
Ozone may be removed from air by molecular filters. To help
customers assess the effectiveness of different products, Camfil Filter Type Average Ozone Ozone Rating
introduce an ozone removal efficiency rating system. This is a Removal Efficiency
first in the filtration industry. City-Flo XL 35% 3

CityPleat 200 2” 50% 5

Ozone CityPleat 480 4” 65% 6

CitySorb 70% 7
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Ozone is a naturally occurring gas that is widely present in our


environment at ground level. The ozone molecule is composed City-Flo 80% 8

of three oxygen atoms, rather than the two atoms of normal CityCarb I 90% 9
oxygen. Ozone is formed by the interaction of other gaseous (i) All filters tested at 2.5 m/s face velocity (500 fpm);
pollutants such as oxides of nitrogen and volatile organic ii) Ozone challenge = 150 – 450 ppb;
compounds (VOCs) under the influence of ultraviolet (UV) light. iii) Temperature = 22 deg C;
iv) Relative humidity = 50%)
City centre levels of ozone increase during periods of high
sunlight. Ozone is classed as an oxidising agent, and has the
potential to damage or destroy other molecules.
All the filters use a high quality broad spectrum adsorbent,
Ozone and human health based on activated carbon to destroy the ozone molecules.
Laboratory tests show that filters based on the use of
Ozone is an extremely reactive gas and inhalation of ozone can potassium permanganate, which is itself a strong oxidising
be harmful to human health. The presence of ozone in air may agent are unlikely to be effective.
be readily correlated to hospital admission rates relating to
respiratory illness. Symptoms of ozone exposure include; throat
irritation, aggravation of asthma, decrease in lung function and
increased susceptibility to respiratory infection. Ambient ozone
levels and high alerts may be available on local government
websites in many parts of the world.

2
General Ventilation Filters | Pre-Filtration

Media Rolls
Advantages
• Available for all kind of • Cut to Order
applications • Different efficiencies available

Application: CM: For use as a prefilter in air conditioning, and spray


booth ventilation

CDM: For fine filtration in air conditioning devices and installations,


particularly final filtration in Automotive spray booths and drying
cabinets.
Media: Synthetic, Polyester
Rec. final pressure drop: 150 Pa
Max Temperature (°C): 80ºC - 100ºC
Relative Humidity max: 100%
Comment: Fire Rating: DIN53438 class F1 for CM, UL 900 for CDM

ASHRAE Dimensions Media Thickness Weight Pressure drop Weight Velocity


Art. No. Type Media EN779 ISO16890
52.2:2017 WxL (m) (mm) (g/m²) (Pa) (kg) (m/s)

5200003 CM-355 Synthetic MERV 6 G3 Coarse 50% 2,0x 20 10 150 30 6,0 1,0

5200006 CM-360 Synthetic MERV 7 G4 Coarse 60% 2,0x 20 20 190 45 7,6 1,0

5200013 Camtex CDM-600 Polyester MERV 10 M5 Coarse 85% 2,0x 20 23-25 600 85 24,5 1,0

5200015 Camtex CDM-600 Polyester MERV 10 M5 Coarse 85% 1.7x 20 20 600 85 24,5 1.0
Other sizes and cut pads available on request.
Depth: Deviation possible.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2
General Ventilation Filters | Pre-Filtration

Fan Coil Filters


Advantages
• Protection via 2 grids • Progressively built-up thermal
• Ultra compact bonded polyester fibre
• Supported media-upstream
and downstream metal face
grids

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Aluminium
Media: Polyester
Max Temperature (°C): 80°C-100°C maximum in continuous services
Comment: Holding Frame: Type 8
Fire rating: DIN 53438 class F1

Airflow/pressure drop
Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
(m³/h/Pa)

5404501 FCF 24x24x1-G3 MERV 6 G3 Coarse 50% 597x 597x 22 3400/ 115 0.356 1.35

5404511 FCF 24x12x1-G3 MERV 6 G3 Coarse 50% 597x 292x 22 1700/ 144 0.174 1.57

5404001 FCF 24x24x1-G4 MERV 7 G4 Coarse 60% 597x 597x 22 3400/ 140 0.356 1.39

5404002 FCF 24x12x1-G4 MERV 7 G4 Coarse 60% 597x 292x 22 1700/ 190 0.174 1.29
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2
General Ventilation Filters | Pre-Filtration

Media Holding Frame (MHF)


Advantages
• Suitable for high humidity • Progressively built-up thermal
conditions bonded polyester fibre
• Replaceble filter media

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Anodized aluminium
Media: Polyester
Max Temperature (°C): 80ºC - 100ºC maximum in continuous service
Installation Options: Front and side access housings and frames are
available, Type 8 and FC Housings
Comment: Fire Rating: DIN 53438 class F1

ASHRAE Dimensions WxHxD Airflow/pressure drop Weight


Art. No. Type EN779 ISO16890 Area (m²)
52.2-2017 (mm) (m³/h/Pa) (kg)

5402501 MHF-24/24/2-G3 MERV 6 G3 Coarse 50% 594x 594x 46 3400/ 100 0.57 1.17

5402502 MHF-12/24/2-G3 MERV 6 G3 Coarse 50% 289x 594x 46 1700/ 150 0.30 1.52

5402001 MHF-24/24/2-G4 MERV 7 G4 Coarse 60% 594x 594x 46 3400/ 110 0.57 1.69

5402002 MHF-12/24/2-G4 MERV 7 G4 Coarse 60% 289x 594x 46 1700/ 160 0.30 1.18

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2
General Ventilation Filters | Bag Filters

Hi-Cap ®
Advantages
• Low initial pressure drop • Innovative pocket design for
• Flat pressure drop curve optimum air distribution
• Comprehensive range of • Conical pockets
standard sizes

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Galvanised steel
Media: Synthetic
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 50
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70°C max in continuous service
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available, Type 8 and FC Housings
Comment: Fire rating: DIN 53438 class F1

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Bags Area (m²) Weight (kg)

3202009 HF 90/35- 592*592-6*580-66 G4 Coarse 60% 592x 592x 580 3400/ 30 6 4,2 2,6

3202033 HF 90/35- 490*592-5.580-66 G4 Coarse 60% 490x 592x 580 2800/ 30 5 3,5 2,2

3202016 HF 90/35-287*592-3.580-36 G4 Coarse 60% 287x 592x 580 1700/ 30 3 2,0 1,5

3200005 HF 90/35-66 G4 Coarse 60% 592x 592x 360 3400/ 40 6 2,6 2,2

3200006 HF 90/35-56 G4 Coarse 60% 490x 592x 360 2800/ 40 5 2,2 1,9

3200007 HF 90/35-36 G4 Coarse 60% 287x 592x 360 1700/ 40 3 1,3 1,3

3100008 HF 90/35-55 G4 Coarse 60% 490x 490x 360 2334/ 50 5 1.8 1.7
Other dimensions are available on request - All dimensions are nominal
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
General Ventilation Filters | Bag Filters

Hi-Cap ProSafe
Advantages
• ProSafe certified for Food • Free of bisphenol-A, phthalate
Beverage, Life Science or close and formaldehyde
to product applications • Tested for food safety acc. to
• Chemically resistant to EC 1935:2004
decontamination, inactivation • Manufactured and packed in a
and cleaning agent controlled environment
• Microbial inert components • Packaging suitable for
acc. to ISO 846 cleanroom unpacking
• Compliant to VDI 6022

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Plastic
Media: Synthetic
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 50
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
Comment: Packing: Hygienic packing in plastic bag. Outer packing:
Environmental friendly cardboard box, easy to carry

Food and Beverage or Life-Science activities have set new standards in product quality and therefore require specific characteristics
regarding process definition.
Camfil, as the leader in clean air solutions and air filtration, has developed the complete ProSafe range of products designed for the
most demanding processes, including safety, traceability and audits requirement.

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Bags Area (m²) Weight (kg)

3204018-P Hi-Cap ProSafe-G4-592x592-6x520 G4 Coarse 60% 592x 592x 520 3400/ 30 6 3,7 1,2

3204019-P Hi-Cap ProSafe-G4-490x592-5x520 G4 Coarse 60% 490x 592x 520 2800/ 30 5 3,0 1

3204020-P Hi-Cap ProSafe-G4-287x592-3x520 G4 Coarse 60% 287x 592x 520 1700/ 30 3 1,8 0,7

3204021-P Hi-Cap ProSafe-G4-592x592-6x370 G4 Coarse 60% 592x 592x 370 3400/ 35 6 2,6 1

3204022-P Hi-Cap ProSafe-G4-490x592-5x370 G4 Coarse 60% 490x 592x 370 2800/ 35 5 2,2 0,9

3204023-P Hi-Cap ProSafe-G4-287x592-3x370 G4 Coarse 60% 287x 592x 370 1700/ 35 3 1,3 0,6
Other dimensions are available on request - All dimensions are nominal
Certification and test results available online

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3
General Ventilation Filters | Bag Filters

Hi-Cap ® XLS
Advantages
• Low initial pressure drop • Innovative pocket design for
• Flat pressure drop curve optimum air distribution
• Comprehensive range of • Conical pockets
standard sizes

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Plastic moulded
Media: Synthetic
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 50
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available, Type 8 and FC Housings.

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Bags Area (m²) Weight (kg)

3204001 HF XLS 90/35-66 G4 Coarse 60% 592x 592x 360 3400/ 50 6 2,6 1,7

3204003 HF XLS 90/35-36 G4 Coarse 60% 287x 592x 360 1700/ 50 3 1,3 1,3

3204002 HF XLS 90/35-56 G4 Coarse 60% 490x 592x 360 2800/ 50 5 2,2 1,6
Other dimensions are available on request - All dimensions are nominal
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3
General Ventilation Filters | Bag Filters

Hi-Flo XLT
Advantages
• Lowest energy consumption • Lowest labour cost thanks to
and initial pressure drop less frequent filter changes
• Extended operating life • Conical and tapered pocket
with the best total cost of shape for improved air flow
ownership (TCO) • Fully incinerable with the
plastic frame

Application: Air conditioning applications and as pre filters for clean


rooms
Frame: Plastic moulded
Media: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

ASHRAE Dimensions WxHxD Airflow/pressure drop Energy Energy


Art. No. Type EN779 ISO16890 Bags Area (m²) Weight (kg)
52.2:2017 (mm) (m³/h/Pa) consumption class

3146017 6/640 MERV A 11A M6 ePM2,5 50% 592x 592x 640 3400/ 55 10 7,5 2,3 748 A

3146018 6/640 MERV A 11A M6 ePM2,5 50% 490x 592x 640 2800/ 55 8 6 1,6 A

3146019 6/640 MERV A 11A M6 ePM2,5 50% 287x 592x 640 1700/ 55 5 3,7 1,4 A

3146001 6/520 MERV A 11A M6 ePM2,5 50% 592x 592x 520 3400/ 65 10 6,1 2,2 929 B

3146002 6/520 MERV A 11A M6 ePM2,5 50% 490x 592x 520 2800/ 65 8 4,9 1,4 B

3146003 6/520 MERV A 11A M6 ePM2,5 50% 287x 592x 520 1700/ 65 5 3 1,3 B

3146122 7/670 MERV A 13A F7 ePM1 60% 592x 592x 670 3400/ 65 10 7,9 2,3 838 A+

3146123 7/670 MERV A 13A F7 ePM1 60% 490x 592x 670 2800/ 65 8 6,3 1,6 A+

3146124 7/670 MERV A 13A F7 ePM1 60% 287x 592x 670 1700/ 65 5 3,8 1,4 A+

3146125 7/640 MERV A 13A F7 ePM1 60% 592x 592x 640 3400/ 70 10 7,5 2,3 918 A

3146126 7/640 MERV A 13A F7 ePM1 60% 490x 592x 640 2800/ 70 8 6 1,6 A

3146127 7/640 MERV A 13A F7 ePM1 60% 287x 592x 640 1700/ 70 5 3,7 1,4 A

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
3146101 7/520 MERV A 13A F7 ePM1 60% 592x 592x 520 3400/ 75 10 6,1 2,2 1031 B

3146102 7/520 MERV A 13A F7 ePM1 60% 490x 592x 520 2800/ 75 8 4,9 1,4 B

3146103 7/520 MERV A 13A F7 ePM1 60% 287x 592x 520 1700/ 75 5 3 1,3 B

3146207 8/640 MERV A 14A F8 ePM1 75% 592x 592x 640 3400/130 10 7,5 2,3

3146208 8/640 MERV A 14A F8 ePM1 75% 490x 592x 640 2800/130 8 6,0 1,6

3146209 8/640 MERV A 14A F8 ePM1 75% 287x 592x 640 1700/130 5 3,7 1,4 Eurovent not applicable
3146210 8/520 MERV A 14A F8 ePM1 75% 592x 592x 520 3400/155 10 6,1 2,2

3146202 8/520 MERV A 14A F8 ePM1 75% 490x 592x 520 2800/155 8 4,9 1,4

3146203 8/520 MERV A 14A F8 ePM1 75% 287x 592x 520 1700/155 5 3,0 1,3

3146314 9/640 MERV A 15A F9 ePM1 85% 592x 592x 640 3400/ 115 10 7,5 1,6 1474 C

3146315 9/640 MERV A 15A F9 ePM1 85% 490x 592x 640 2800/ 115 8 6,3 1,6 C

3146316 9/640 MERV A 15A F9 ePM1 85% 287x 592x 640 1700/ 115 5 3,7 1,4 C

3146301 9/520 MERV A 15A F9 ePM1 85% 592x 592x 520 3400/ 165 10 6,1 2,2 2091 D

3146302 9/520 MERV A 15A F9 ePM1 85% 490x 592x 520 2800/ 165 8 4,9 1,4 D

3146303 9/520 MERV A 15A F9 ePM1 85% 287x 592x 520 1700/ 165 5 3 1,3 D
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

3
General Ventilation Filters | Bag Filters

Hi-Flo XLS
Advantages
• Low initial pressure drop • Innovative pocket design for
• Flat pressure drop curve optimum air distribution
• Comprehensive range of • Conical pockets
standard sizes • Fully incinerable with the
plastic frame

Application: Air conditioning applications and as pre filters for clean


rooms
Frame: Plastic moulded
Media: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

ASHRAE Dimensions WxHxD Airflow/pressure drop Energy


Art. No. Type EN779 ISO16890 Bags Area (m²) Weight (kg) Energy class
52.2:2017 (mm) (m³/h/Pa) consumption

3146418 5/520 MERV A 10A M5 ePM10 60% 592x 592x 520 3400/ 50 6 3,7 0,9 793 C

3146419 5/520 MERV A 10A M5 ePM10 60% 490x 592x 520 2800/ 50 5 3 0,8 C

3146420 5/520 MERV A 10A M5 ePM10 60% 287x 592x 520 1700/ 50 3 1,8 0,6 C

3146415 5/640 MERV A 10A M5 ePM10 60% 592x 592x 640 3400/ 45 6 4,5 1 770 C

3146416 5/640 MERV A 10A M5 ePM10 60% 490x 592x 640 2800/ 45 5 3,7 0,9 C

3146417 5/640 MERV A 10A M5 ePM10 60% 287x 592x 640 1700/ 45 3 2,2 0,6 C

3146421 5/370 MERV A 10A M5 ePM10 60% 592x 592x 370 3400/ 60 6 2,6 0,8 >1200 E

3146422 5/370 MERV A 10A M5 ePM10 60% 490x 592x 370 2800/ 60 5 2,2 0,7 E

3146423 5/370 MERV A 10A M5 ePM10 60% 287x 592x 370 1700/ 60 3 1,3 0,5 E

3146020 6/640 MERV A 11A M6 ePM2,5 50% 592x 592x 640 3400/ 70 6 4,5 1,2 1212 C

3146021 6/640 MERV A 11A M6 ePM2,5 50% 490x 592x 640 2800/ 70 5 3,7 1 C

3146022 6/640 MERV A 11A M6 ePM2,5 50% 287x 592x 640 1700/ 70 3 2,2 0,7 C

3146023 6/520 MERV A 11A M6 ePM2,5 50% 592x 592x 520 3400/ 80 6 3,7 1,1 1552 D
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3146024 6/520 MERV A 11A M6 ePM2,5 50% 490x 592x 520 2800/ 80 5 3 0,9 D

3146025 6/520 MERV A 11A M6 ePM2,5 50% 287x 592x 520 1700/ 80 3 1,8 0,6 D

3146026 6/370 MERV A 11A M6 ePM2,5 50% 592x 592x 370 3400/ 120 6 2,6 0,9 >1900 E

3146027 6/370 MERV A 11A M6 ePM2,5 50% 490x 592x 370 2800/ 120 5 2,2 0,8 E

3146028 6/370 MERV A 11A M6 ePM2,5 50% 287x 592x 370 1700/ 120 3 1,3 0,6 E

3146128 7/640 MERV A 13A F7 ePM1 60% 592x 592x 640 3400/ 85 6 4,5 0,9 1371 C

3146129 7/640 MERV A 13A F7 ePM1 60% 490x 592x 640 2800/ 85 5 3,7 0,8 C

3146130 7/640 MERV A 13A F7 ePM1 60% 287x 592x 640 1700/ 85 3 2,2 0,6 C

3146131 7/520 MERV A 13A F7 ePM1 60% 592x 592x 520 3400/ 115 6 3,7 0,9 1948 D

3146132 7/520 MERV A 13A F7 ePM1 60% 490x 592x 520 2800/ 115 5 3 0,8 D

3146133 7/520 MERV A 13A F7 ePM1 60% 287x 592x 520 1700/ 115 3 1,8 0,5 D

3146134 7/370 MERV A 13A F7 ePM1 60% 592x 592x 370 3400/ 165 6 2,6 0,9 >2050 E

3146135 7/370 MERV A 13A F7 ePM1 60% 490x 592x 370 2800/ 165 5 2,2 0,7 E

3146136 7/370 MERV A 13A F7 ePM1 60% 287x 592x 370 1700/ 165 3 1,3 0,5 E

3146318 9/640 MERV A 15A F9 ePM1 85% 490x 592x 640 2800/ 200 5 3,7 0,9 E

3146319 9/640 MERV A 15A F9 ePM1 85% 287x 592x 640 1700/ 200 3 2,2 0,6 E

3146320 9/520 MERV A 15A F9 ePM1 85% 592x 592x 520 3400/ 230 6 3,7 0,9 >2400 E

3146321 9/520 MERV A 15A F9 ePM1 85% 490x 592x 520 2800/ 230 5 3 0,8 E

3146322 9/520 MERV A 15A F9 ePM1 85% 287x 592x 520 1700/ 230 3 1,8 0,5 E

3146317 9/640 MERV A 15A F9 ePM1 85% 592x 592x 640 3400/ 200 6 4,5 1 >2400 E
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

3
General Ventilation Filters | Bag Filters

Hi-Flo M, P, TM
Advantages
• Lowest energy consumption • Lowest labour cost thanks to
and initial pressure drop less frequent filter changes
• Extended operating life • Conical and tapered pocket
with the best total cost of shape for improved air flow
ownership (TCO)

Application: Air conditioning applications


Frame: Galvanised steel
Media: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
Comment:
Fire rating: UL 900

ASHRAE Airflow/pressure drop Energy


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg) Energy class
52.2:2017 (m³/h/Pa) consumption

3140001 M6 MERV A 11A M6 ePM2,5 50% 592x 592x 640 3400/ 55 12 9,1 3,3 748 A

3140002 N6 MERV A 11A M6 ePM2,5 50% 490x 592x 640 2800/ 55 10 7,6 3 A

3140003 O6 MERV A 11A M6 ePM2,5 50% 287x 592x 640 1700/ 55 6 4,6 2 A

3140009 P6 MERV A 11A M6 ePM2,5 50% 592x 592x 520 3400/ 65 10 6,2 2,9 992 C

3140010 Q6 MERV A 11A M6 ePM2,5 50% 490x 592x 520 2800/ 65 8 5,1 2,4 C

3140011 R6 MERV A 11A M6 ePM2,5 50% 287x 592x 520 1700/ 65 5 3,1 1,5 C

3140025 TM6 MERV A 11A M6 ePM2,5 50% 592x 592x 370 3400/ 70 12 5,5 2,55 1280 C

3140026 TN6 MERV A 11A M6 ePM2,5 50% 490x 592x 370 2800/ 70 10 4,5 2,15 C

3140027 TO6 MERV A 11A M6 ePM2,5 50% 287x 592x 370 1700/ 70 6 2,7 1,4 C

3140029 M7 MERV A 13A1 F7 ePM1 60% 592x 592x 640 3400/ 60 12 9,1 3,3 838 A+

3140030 N7 MERV A 13A F7 ePM1 60% 490x 592x 640 2800/ 60 10 7,6 3 A+

3140031 O7 MERV A 13A F7 ePM1 60% 287x 592x 640 1700/ 60 6 4,6 2 A+

3140037 P7 MERV A 13A F7 ePM1 60% 592x 592x 520 3400/ 75 10 6,2 2,6 895 A

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
3140038 Q7 MERV A 13A F7 ePM1 60% 490x 592x 520 2800/ 75 8 5,1 2,3 A

3140039 R7 MERV A 13A F7 ePM1 60% 287x 592x 520 1700/ 75 5 3,1 1,6 A

3140053 TM7 MERV A 13A F7 ePM1 60% 592x 592x 370 3400/ 95 12 5,2 2,3 1427 C

3140054 TN7 MERV A 13A F7 ePM1 60% 490x 592x 370 2800/ 95 10 4,3 2,05 C

3140055 TO7 MERV A 13A F7 ePM1 60% 287x 592x 370 1700/ 95 6 2,6 1,35 C

3140057 M8 MERV A 14A F8 ePM1 70% 592x 592x 640 3400/ 130 12 9.1 2.9

3140058 N8 MERV A 14A F8 ePM1 70% 490x 592x 640 2800/ 130 10 7.6 2.5

3140059 O8 MERV A 14A F8 ePM1 70% 287x 592x 640 1700/ 130 6 4.6 1.7

3140065 P8 MERV A 14A F8 ePM1 70% 592x 592x 520 3400/ 160 10 6.5 2.41

3140066 Q8 MERV A 14A F8 ePM1 70% 490x 592x 520 2800/ 160 8 5.2 2.03

3140067 R8 MERV A 14A F8 ePM1 70% 287x 592x 520 1700/ 160 5 3.3 1.43

3140081 TM8 MERV A 14A F8 ePM1 70% 592x 592x 370 3400/ 205 12 5.5 2.45

3140082 TN8 MERV A 14A F8 ePM1 70% 490x 592x 370 2800/ 205 10 4.5 2.12

3140083 TO8 MERV A 14A F8 ePM1 70% 287x 592x 370 1700/ 205 6 2.7 1.45

3145006 M9 MERV A 15A F9 ePM1 85% 592x 592x 640 3400/ 125 12 9,1 3,3 1520 C

3145009 N9 MERV A 15A F9 ePM1 85% 490x 592x 640 2800/ 125 10 7,6 3 C

3145007 O9 MERV A 15A F9 ePM1 85% 287x 592x 640 1700/ 125 6 4,6 2 C

3145008 P9 MERV A 15A F9 ePM1 85% 592x 592x 520 3400/ 155 10 6,2 2,5 1880 D

3145010 Q9 MERV A 15A F9 ePM1 85% 490x 592x 520 2800/ 155 8 5,1 2,4 D

3145011 R9 MERV A 15A F9 ePM1 85% 287x 592x 520 1700/ 155 5 3,1 1,5 D
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019
SGBC is only applicable for F8 and F9 class filters

3
General Ventilation Filters | Bag Filters

Hi-Flo A, UF
Advantages
• Low initial pressure drop • Innovative pocket design for
• Flat pressure drop curve optimum air distribution
• Comprehensive range of • Conical pockets
standard sizes • Robust metal header frame

Application: Comfort air conditioning applications, pre filter


applications
Frame: Galvanised steel
Media: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
Comment: Fire rating: UL 900

Airflow/pressure drop Energy


Art. No. Type ASHRAE 52.2:017 EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg) Energy class
(m³/h/Pa) consumption

3140085 A5 MERV A 10A M5 ePM10 60% 592x 592x 600 3400/ 45 6 4,5 1,9 748 C

3140086 B5 MERV A 10A M5 ePM10 60% 490x 592x 600 2800/ 45 5 3,6 1,6 C

3140087 C5 MERV A 10A M5 ePM10 60% 287x 592x 600 1700/ 45 3 2,3 1,1 C

3140017 A6 MERV A 11A M6 ePM2,5 50% 592x 592x 600 3400/ 70 6 4,5 1,9 1189 C

3140018 B6 MERV A 11A M6 ePM2,5 50% 490x 592x 600 2800/ 70 5 3,6 1,6 C

3140019 C6 MERV A 11A M6 ePM2,5 50% 287x 592x 600 1700/ 70 3 2,3 1,1 C

3100013 UF6 MERV A 11A M6 ePM2,5 50% 592x 592x 600 3400/ 60 8 6 2,9 872 B

3100014 UG6 MERV A 11A M6 ePM2,5 50% 490x 592x 600 2800/ 60 6 4,5 2,4 B

3100015 UH6 MERV A 1A M6 ePM2,5 50% 287x 592x 600 1700/ 60 4 3 1,5 B

3140016 3UF6 MERV A 11A M6 ePM2,5 50% 490x 490x 600 2334/ 70 6 4.1 1.65 B

3140045 A7 MERV A 13A F7 ePM1 60% 592x 592x 600 3400/ 95 6 4,5 1,9 1337 C

3140046 B7 MERV A 13A F7 ePM1 60% 490x 592x 600 2800/ 95 5 3,6 1,6 C
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3140047 C7 MERV A 13A F7 ePM1 60% 287x 592x 600 1700/ 95 3 2,3 1,1 C

3100041 UF7 MERV A 13A F7 ePM1 60% 592x 592x 600 3400/ 75 8 6 2,9 940 A

3100042 UG7 MERV A 13A F7 ePM1 60% 490x 592x 600 2800/ 75 6 4,5 2,4 A

3100043 UH7 MERV A 13A F7 ePM1 60% 287x 592x 600 1700/ 75 4 3 1,5 A

3140044 3UF7 MERV A 13A F7 ePM1 70% 490x 490x 600 2334/ 115 6 4.1 1.65 B

3140073 A8 MERV A 14A F8 ePM1 70% 592x 592x 600 3400/ 160 6 6.2 2.4

3140074 B8 MERV A 1A F8 ePM1 70% 490x 592x 600 2800/ 160 5 5.1 2.03

3140075 C8 MERV A 14A F8 ePM1 70% 287x 592x 600 1700/ 160 3 3.1 1.4

3140069 UF8 MERV A 14A F8 ePM1 70% 592x 592x 600 3400/ 160 8 6 2.19

3140070 UG8 MERV A 14A F8 ePM1 70% 490x 592x 600 2800/ 160 6 4.5 1.8

3140071 UH8 MERV A 14A F8 ePM1 70% 287x 592x 600 1700/ 160 4 3 1.32

3140072 3UF8 MERV A 14A F8 ePM1 70% 490x 490x 600 2334/ 160 6 4.1 1.7

3105012 UF9 MERV A 15A F9 ePM1 85% 592x 592x 600 3400/ 160 8 6 2,9 1956 D

3105013 UG9 MERV A 15A F9 ePM1 85% 490x 592x 600 2800/ 160 6 4,5 2,4 D

3105014 UH9 MERV A 15A F9 ePM1 85% 287x 592x 600 1700/ 160 4 3 1,5 D

3145015 3UF9 MERV A 15A F9 ePM1 85% 490x 490x 600 2334/ 160 6 3.6 1.7 D
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019
General Ventilation Filters | Bag Filters

City-Flo XL
Advantages
• “2-in-1” filtration solution; • Ideal for filtering low
particulate and molecular concentrations of most
• Removal of solid and gaseous external and internal source
contaminants in one filter pollutants
stage • Can be used to upgrade
existing installations
• Incinerable plastic header
frame

Application: Particulate and molecular filter


Frame: Plastic moulded
Media: Glass fiber/Activated carbon
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 50ºC
EFFICIENCY GUARANTEE
Relative Humidity max: 70%
Installation Options: Front and side access housings and frames are
available

Airflow/pressure
Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg)
drop (m³/h/Pa)

612754 7/640 F7 ePM1 60% 592x 592x 640 3400/ 85 10 7,5 3,5

613289 7/640 F7 ePM1 60% 490x 592x 640 2800/ 85 8 6 2,8

612924 7/640 F7 ePM1 60% 287x 592x 640 1700/ 85 5 3,7 1,8

613293 7/640 F7 ePM1 60% 592x 490x 640 2800/ 85 10 6,2 2,9

613291 7/640 F7 ePM1 60% 490x 490x 640 2330/ 85 8 5 2,4

613295 7/640 F7 ePM1 60% 592x 287x 640 1700/ 85 10 3,7 1,8

613297 7/640 F7 ePM1 60% 287x 287x 640 800/ 85 5 1,9 0,9

612753 7/520 F7 ePM1 60% 592x 592x 520 3400/ 110 10 6,1 3,1

613290 7/520 F7 ePM1 60% 490x 592x 520 2800/ 110 8 4,9 2,5

612923 7/520 F7 ePM1 60% 287x 592x 520 1700/ 110 5 3 1,6

613294 7/520 F7 ePM1 60% 592x 490x 520 2800/ 110 10 6,2 3,1

613292 7/520 F7 ePM1 60% 490x 490x 520 2330/ 110 8 4 2

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
613296 7/520 F7 ePM1 60% 592x 287x 520 1700/ 110 10 3 1,6

613298 7/520 F7 ePM1 60% 287x 287x 520 800/ 110 5 1,5 0,8
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

3
General Ventilation Filters | Bag Filters

City-Flo
Advantages
• “2-in-1” filtration solution; • Ideal for filtering moderate
particulate and molecular concentrations of most
• Removal of solid and gaseous external and internal source
contaminants in one filter pollutants
stage • Can be used to upgrade
existing installations
• Robust metal header frame

Application: Particle and odour removal in Hospitals, Offices,


Airports etc
Frame: Galvanised steel
Media: Glass fiber/Activated carbon
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 50°C
EFFICIENCY GUARANTEE
Relative Humidity max: 70%
Installation Options: Front and side access housings and frames are
available

The City-Flo filter utilizes a highly effective broad spectrum carbon media layer to ensure removal of a very wide range of airborne
chemicals.
The broad spectrum carbon operates with a Rapid Adsorption Dynamics (RAD) mechanism that is specifically designed to be highly
efficient against the multiple chemicals that are typically present in low or moderate concentrations in city-centre buildings or other
locations.
City-Flo is a very effective ozone filter with an 80% ozone removal efficiency or Oz8 ozone removal rating according to the unique Camfil
system.
The City-Flo filter provides particle filtration in classes F7 or F9 according to EN 779:2012. A high media area ensures high efficiency,
long life and low pressure drop.

Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Bags Area (m²) Weight (kg)

HFZS-F7-592/592/534-10-25 F7 ePM1 60% 592x 592x 534 3400/ 140 10 6,2 6

HFZS-F7-490/592/534-8-25 F7 ePM1 60% 490x 592x 534 2800/ 140 8 5 4,6

HFZS-F7-287/592/534-8-25 F7 ePM1 60% 287x 592x 534 1700/ 140 5 3,1 3,5

Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019


Energy class: according to Eurovent RS 4/C/001-2019
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3
General Ventilation Filters | Bag Filters

Basic-Flo
Advantages
• Economy version • Optimized filter area with
• Resilient synthetic filter media conical filter bags
• Robust metal header frame

Application: Comfort air conditioning applications, prefilter


applications
Frame: Galvanised steel
Media: Synthetic
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 90%
Installation Options: Front and side access housings and frames are
available

EFFICIENCY GUARANTEE

Airflow/pressure drop Energy


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg) Energy class
(m³/h/Pa) consumption

3320001 A5 M5 ePM10 50% 592x 592x 600 3400/ 50 6 4,5 2,4 929 D

3320002 B5 M5 ePM10 50% 490x 592x 600 2800/ 50 5 3,6 2,1 D

3320003 C5 M5 ePM10 50% 287x 592x 600 1700/ 50 3 2,3 1,5 D

3320004 A5/520 M5 ePM10 50% 592x 592x 520 3400/ 55 6 3,7 2 940 D

3320005 B5/520 M5 ePM10 50% 490x 592x 520 2800/ 55 5 3 1,8 D

3320006 C5/520 M5 ePM10 50% 287x 592x 520 1700/ 55 3 1,8 1,2 D

3320007 A5/370 M5 ePM10 50% 592x 592x 370 3400/ 60 6 2,6 1,8 >1100 E

3320008 B5/370 M5 ePM10 50% 490x 592x 370 2800/ 60 5 2,2 1,6 E

3320009 C5/370 M5 ePM10 50% 287x 592x 370 1700/ 60 3 1,3 1,2 E

3320051 A6 M6 ePM10 70% 592x 592x 600 3400/ 60 6 4,5 2,4 >1300 E

3320052 B6 M6 ePM10 70% 490x 592x 600 2800/ 60 5 3,6 2,1 E

3320053 C6 M6 ePM10 70% 287x 592x 600 1700/ 60 3 2,3 1,5 E

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
3320054 A6/520 M6 ePM10 70% 592x 592x 520 3400/ 65 6 3,7 2 >1300 E

3320055 B6/520 M6 ePM10 70% 490x 592x 520 2800/ 65 5 3 1,8 E

3320056 C6/520 M6 ePM10 70% 287x 592x 520 1700/ 65 3 1,8 1,2 E

3320057 A6/370 M6 ePM10 70% 592x 592x 370 3400/ 85 6 2,6 1,8 >1300 E

3320058 B6/370 M6 ePM10 70% 490x 592x 370 2800/ 85 5 2,2 1,6 E

3320059 C6/370 M6 ePM10 70% 287x 592x 370 1700/ 85 3 1,3 1,2 E

3320101 A7 F7 ePM2,5 70% 592x 592x 600 3400/ 120 6 4,5 2,4 1937 D

3320102 B7 F7 ePM2,5 70% 490x 592x 600 2800/ 120 5 3,6 2,1 D

3320103 C7 F7 ePM2,5 70% 287x 592x 600 1700/ 120 3 2,3 1,5 D

3320104 A7/520 F7 ePM2,5 70% 592x 592x 520 3400/ 135 6 3,7 2 >2000 E

3320105 B7/520 F7 ePM2,5 70% 490x 592x 520 2800/ 135 5 3 1,8 E

3320106 C7/520 F7 ePM2,5 70% 287x 592x 520 1700/ 135 3 1,8 1,2 E

3320107 A7/370 F7 ePM2,5 70% 592x 592x 370 3400/ 185 6 2,6 1,8 >2000 E

3320108 B7/370 F7 ePM2,5 70% 490x 592x 370 2800/ 185 5 2,2 1,6 E

3320109 C7/370 F7 ePM2,5 70% 287x 592x 370 1700/ 185 3 1,3 1,2 E

3320110 UF7 F7 ePM2,5 70% 592x 592x 600 3400/ 110 8 6 2,6 1790 D

3320111 UG7 F7 ePM2,5 70% 490x 592x 600 2800/ 110 6 4,5 2,4 D

3320112 UH7 F7 ePM2,5 70% 287x 592x 600 1700/ 110 4 3 1,5 D

3320113 UF7/520 F7 ePM2,5 70% 592x 592x 520 3400/ 120 8 5,2 2,6 1 971 D

3320114 UG7/520 F7 ePM2,5 70% 490x 592x 520 2800/ 120 6 3,9 2,4 D

3320115 UH7/520 F7 ePM2,5 70% 287x 592x 520 1700/ 120 4 2,5 1,5 D

3
General Ventilation Filters | Bag Filters

Airflow/pressure drop Energy


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg) Energy class
(m³/h/Pa) consumption

3320116 UF7/370 F7 ePM2,5 70% 592x 592x 370 3400/ 150 8 3,6 2,4 >2000 E

3320117 UG7/370 F7 ePM2,5 70% 490x 592x 370 2800/ 150 6 2,7 2,1 E

3320118 UH7/370 F7 ePM2,5 70% 287x 592x 370 1700/ 150 4 1,8 1,5 E

3326003 UF8 F8 ePM1 70% 592x 592x 600 3400/ 155 8 6 2,8 2458 E

3326007 UG8 F8 ePM1 70% 490x 592x 600 2800/ 155 6 4.5 2.6 E

3326008 UH8 F8 ePM1 70% 287x 592x 600 1700/ 155 4 3 1.7 E

3326009 UF8/520 F8 ePM1 70% 592x 592x 520 3400/ 170 8 5.2 2.7 E

3326010 UG8/520 F8 ePM1 70% 490x 592x 520 2800/ 170 6 3.9 2.5 E

3326011 UH8/520 F8 ePM1 70% 287x 592x 520 1700/ 170 4 2.5 1.6 E
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019
20mm header frame is availableon request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
General Ventilation Filters | Bag Filters

S-Flo A, P, U
Advantages
• Extended surface multi-pocket • High efficiency
filter • Large surface area
• Comprehensive range of • Controlled media spacing
standard sizes (CMS)
• Unique pocket design

Application: Air conditioning applications


Frame: Galvanised steel
Media: Synthetic
Rec. final pressure drop: 450 Pa
Max Temperature (°C): 70 °C maximum in continuous service
Installation Options: Holding frames: Front and side access housings
and frames are available, Type 8 and FC Housings
Comment: Fire rating: UL 900

ASHRAE Dimensions WxHxD Airflow/pressure drop


Art. No. Type ISO16890 Bags Area (m²) Weight (kg)
52.2-2017 (mm) (m³/h/Pa)

3300010 Q6 MERV 11 ePM10 70% 490x 592x 534 2800/ 90 8 5.2 2.44

3300009 P6 MERV 11 ePM10 70% 592x 592x 534 3400/ 90 10 6.5 2.92

3300011 R6 MERV 11 ePM10 70% 287x 592x 534 1700/ 90 5 3.2 1.68

3300033 P7 MERV 13 ePM10 80% 592x 592x 534 3400/ 115 10 6.5 2.92

3300034 Q7 MERV 13 ePM10 80% 490x 592x 534 2800/ 115 8 5.2 2.44

3300035 R7 MERV 13 ePM10 80% 287x 592x 534 1700/ 115 5 3.2 1.68

3300057 P8 MERV 14 ePM10 85% 592x 592x 534 3400/ 135 10 6.5 2.92

3300058 Q8 MERV 14 ePM10 85% 490x 592x 534 2800/ 135 8 5.2 2.44

3300059 R8 MERV 14 ePM10 85% 287x 592x 534 1700/ 135 5 3.2 1.68

3300013 UF6 MERV 11 ePM10 70% 592x 592x 600 3400/ 75 8 6 2.65

3300014 UG6 MERV 11 ePM10 70% 490x 592x 600 2800/ 75 6 4.5 2.14

3300015 UH6 MERV 11 ePM10 70% 287x 592x 600 1700/ 75 4 3 1.54

3300037 UF7 MERV 13 ePM10 80% 592x 592x 600 3400/ 95 8 6 2.65

3300038 UG7 MERV 13 ePM10 80% 490x 592x 600 2800/ 95 6 4.5 2.14

3300039 UH7 MERV 13 ePM10 80% 287x 592x 600 1700/ 95 4 3 1.54

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
3300061 UF8 MERV 14 ePM10 85% 592x 592x 600 3400/ 110 8 6 2.65

3300062 UG8 MERV 14 ePM10 85% 490x 592x 600 2800/ 110 6 4.5 2.14

3300063 UH8 MERV 14 ePM10 85% 287x 592x 600 1700/ 110 4 3 1.54

3300073 A5 MERV 10 ePM10 60% 592x 592x 600 3400/ 75 6 4.5 2.4

3300074 B5 MERV 10 ePM10 60% 490x 592x 600 2700/ 75 5 3.6 2

3300075 C5 MERV 10 ePM10 60% 287x 592x 600 1700/ 75 3 2.3 1.5

3300017 A6 MERV 11 ePM10 70% 592x 592x 600 3400/ 100 6 4.5 2.4

3300018 B6 MERV 11 ePM10 70% 490x 592x 600 2800/ 100 5 3.6 2

3300019 C6 MERV 11 ePM10 70% 287x 592x 600 1700/ 100 3 2.3 1.5

3300041 A7 MERV 13 ePM10 80% 592x 592x 600 3400/ 110 6 4.5 2.4

3300042 B7 MERV 13 ePM10 80% 490x 592x 600 2800/ 110 5 3.6 2

3300043 C7 MERV 13 ePM10 80% 287x 592x 600 1700/ 110 3 2.3 1.5

3300065 A8 MERV 14 ePM10 85% 592x 592x 600 3400/ 145 6 4.7 2.4

3300066 B8 MERV 14 ePM10 85% 490x 592x 600 2800/ 145 5 3.6 2.0

3300067 C8 MERV 14 ePM10 85% 287x 592x 600 1700/ 145 3 2.3 1.5
20mm header frame is available on request

4
General Ventilation Filters | Bag Filters

Hi-Flo ProSafe
Advantages
• ProSafe certified for Food • Free of bisphenol-A, phthalate
Beverage, Life Science or close and formaldehyde
to product applications • Tested for food safety acc. to
• Chemically resistant to EC 1935:2004
decontamination, inactivation • Manufactured and packed in a
and cleaning agent controlled environment
• Microbial inert components • Packaging suitable for
acc. to ISO 846 cleanroom unpacking
• Compliant to VDI 6022

Application: Air conditioning applications and as pre filters for clean


rooms
Frame: Plastic
Media: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
EFFICIENCY GUARANTEE
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

Airflow/pressure drop
Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Bags Area (m²) Weight (kg) Energy consumption Energy class
(m³/h/Pa)

3146008 6/640 M6 ePM2,5 50% 592x 592x 640 3400/ 55 10 7,5 2,3 748 A

3146009 6/640 M6 ePM2,5 50% 490x 592x 640 2800/ 55 8 6 1.6 A

3146010 6/640 M6 ePM2,5 50% 287x 592x 640 1700/ 55 5 3.7 1.4 A

3146011 6/520 M6 ePM2,5 50% 592x 592x 520 3400/ 60 10 6.1 2.2 929 B

3146012 6/520 M6 ePM2,5 50% 490x 592x 520 2800/ 60 8 4.9 1.4 B

3146013 6/520 M6 ePM2,5 50% 287x 592x 520 1700/ 60 5 3 1.3 B

3146014 6/370 M6 ePM2,5 50% 592x 592x 370 3400/ 70 10 4.3 2 1405 D

3146015 6/370 M6 ePM2,5 50% 490x 592x 370 2800/ 70 8 3.5 1.3 D
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

3146016 6/370 M6 ePM2,5 50% 287x 592x 370 1700/ 70 5 2.2 1.2 D

3146110 7/670 F7 ePM1 60% 592x 592x 670 3400/ 65 10 7,9 2,3 838 A+

3146111 7/670 F7 ePM1 60% 490x 592x 670 2800/ 65 8 6,3 1,6 A+

3146112 7/670 F7 ePM1 60% 287x 592x 670 1700/ 65 5 3,8 1,4 A+

3146113 7/640 F7 ePM1 60% 592x 592x 640 3400/ 70 10 7,5 2,3 918 A

3146114 7/640 F7 ePM1 60% 490x 592x 640 2800/ 70 8 6 1,6 A

3146115 7/640 F7 ePM1 60% 287x 592x 640 1700/ 70 5 3,7 1,4 A

3146116 7/520 F7 ePM1 60% 592x 592x 520 3400/ 75 10 10 2,2 1031 B

3146117 7/520 F7 ePM1 60% 490x 592x 520 2800/ 75 8 8 1,4 B

3146118 7/520 F7 ePM1 60% 287x 592x 520 1700/ 75 5 3 1,3 B

3146119 7/370 F7 ePM1 60% 592x 592x 370 3400/ 90 10 4,3 2 1643 D

3146120 7/370 F7 ePM1 60% 490x 592x 370 2800/ 90 8 3,5 1,3 D

3146121 7/370 F7 ePM1 60% 287x 592x 370 1700/ 90 5 2,2 1,2 D

3146307 9/640 F9 ePM1 85% 592x 592x 640 3400/ 115 10 7,5 2,3 1474 C

3146308 9/640 F9 ePM1 85% 490x 592x 640 2800/ 115 8 6 1.6 C

3146309 9/640 F9 ePM1 85% 287x 592x 640 1700/ 115 5 3,7 1,4 C

3146310 9/520 F9 ePM1 85% 592x 592x 520 3400/ 165 10 6.1 2.2 2091 D

3146311 9/520 F9 ePM1 85% 490x 592x 520 2800/ 165 8 4.9 1.4 D

3146312 9/520 F9 ePM1 85% 287x 592x 520 1700/ 165 5 3 1.3 D
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019 Certification and test results available online.
General Ventilation Filters | Pleated Panel Filters

Aeropleat III
Advantages
• Moisture resistant cardboard • Fully supported media bonded
frame onto a wire support grid
• Robust construction • Bonded into case to eliminate
• Comprehensive range of air by-pass
standard and non standard
sizes

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Cardboard
Media: Cotton/Synthetic
Rec. final pressure drop: 250 Pa
Max Temperature (°C): 70ºC maximum in continuous service
Installation Options: Front and side access housings and frames are
available, Type 8 and FC Housings
Comment: Fire rating: UL 900

ASHRAE Airflow/pressure drop Weight


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²)
52.2-2017 (m³/h/Pa) (kg)

116300001 Aeropleat III 20x16x2 MERV 8 G4 Coarse 65% 394x 495x 44 1887/ 70 0.6 0.4

116300002 Aeropleat III 20x20x2 MERV 8 G4 Coarse 65% 495x 495x 44 2363/ 70 0.8 0.5

116300003 Aeropleat III 25x20x2 MERV 8 G4 Coarse 65% 495x 622x 44 2950/ 70 1.0 0.6

116300004 Aeropleat III 25x16x2 MERV 8 G4 Coarse 65% 394x 622x 44 2363/ 70 0.73 0.5

116300005 Aeropleat III 24x24x2 MERV 8 G4 Coarse 65% 594x 594x 44 3400/ 70 1.13 0.65

116300006 Aeropleat III 24x12x2 MERV 8 G4 Coarse 65% 289x 594x 44 1656/ 70 0.57 0.35

116300007 Aeropleat III 24x20x2 MERV 8 G4 Coarse 65% 495x 594x 44 2839/ 70 0.96 0.55

116300008 Aeropleat III 24x18x2 MERV 8 G4 Coarse 65% 444x 594x 44 2550/ 70 0.85 0.5

116307001 Aeropleat III 24x24x4 MERV 8 G4 Coarse 65% 594x 594x 95 3400/ 50 2.11 1.2

116307002 Aeropleat III 24x12x4 MERV 8 G4 Coarse 65% 289x 594x 95 1700/ 50 1.05 0.65

116307004 Aeropleat III 20x16x4 MERV 8 G4 Coarse 65% 390x 492x 95 1853/ 50 1.17 0.75

116307005 Aeropleat III 25x16x4 MERV 8 G4 Coarse 65% 390x 619x 95 2332/ 50 1.46 0.9

116307007 Aeropleat III 24x20x4 MERV 8 G4 Coarse 65% 492x 594x 95 2768/ 50 1.76 1.05

116307003 Aeropleat III 20x20x4 MERV 8 G4 Coarse 65% 492x 492x 95 2336/ 50 1.46 0.9

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

4
General Ventilation Filters | Pleated Panel Filters

30/30 ®
Advantages
• Water resistant cardboard • Fully supported media bonded
frame onto a wire support grid
• Robust construction • Radial pleat design for full
• Bonded cross members to media utilization
maintain pleat spacing • Replaceable filter media

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Cardboard
Media: Polyester
Rec. final pressure drop: 250 Pa
Max Temperature (°C): 70ºC maximum in continuous service
Installation Options: Holding frames: Front and side access housings
and frames are available, Type 8 and FC Housings
Comment: Fire rating: UL 900

ASHRAE Airflow/pressure drop Weight


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²)
52.2-2017 (m³/h/Pa) (kg)

54862001 30/30 20x16x1 MERV 8 G4 ePM10 50% 394x 495x 22 1326/ 60 0.5 0.3

54862002 30/30 20x20x1 MERV 8 G4 ePM10 50% 495x 495x 22 1650/ 60 0.61 0.4

54862003 30/30 25x20x1 MERV 8 G4 ePM10 50% 495x 622x 22 2065/ 60 0.74 0.55

54862004 30/30 25x16x1 MERV 8 G4 ePM10 50% 394x 622x 22 1650/ 60 0.62 0.42

54862005 30/30 24x24x1 MERV 8 G4 ePM10 50% 594x 594x 22 2380/ 60 0.91 0.6

54862010 30/30 24x12x1 MERV 8 G4 ePM10 50% 292x 594x 22 1190/ 60 0.46 0.3

54862011 30/30 24x20x1 MERV 8 G4 ePM10 50% 495x 594x 22 1980/ 60 0.74 0.53

49880001 30/30 20x16x2 MERV 8 G4 ePM10 50% 394x 495x 44 1870/ 80 0.92 0.44

49880002 30/30 20x20x2 MERV 8 G4 ePM10 50% 495x 495x 44 2363/ 80 1.11 0.55

49880003 30/30 25x20x2 MERV 8 G4 ePM10 50% 495x 622x 44 2958/ 80 1.39 0.7

49880004 30/30 25x16x2 MERV 8 G4 ePM10 50% 394x 622x 44 2363/ 80 1.15 0.55

49880005 30/30 24x24x2 MERV 8 G4 ePM10 50% 594x 594x 44 3400/ 80 1.61 0.78
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

49880006 30/30 24x12x2 MERV 8 G4 ePM10 50% 289x 594x 44 1700/ 80 0.78 0.4

49880009 30/30 20x14x2 MERV 8 G4 ePM10 50% 343x 495x 44 1658/ 80 0.77 0.25

49880012 30/30 24x20x2 MERV 8 G4 ePM10 50% 495x 594x 44 2839/ 80 1.33 0.45

49880015 30/30 24x18x2 MERV 8 G4 ePM10 50% 444x 594x 44 2550/ 80 1.21 0.61

49880017 30/30 24x16x2 MERV 8 G4 ePM10 50% 394x 594x 44 2270/ 80 1.1 0.55

59413001 30/30 24x24x4 MERV 8 G4 ePM10 50% 594x 594x 95 3400/ 70 2.58 1.45

59413002 30/30 24x12x4 MERV 8 G4 ePM10 50% 289x 594x 95 1700/ 70 1.29 0.6

59413003 30/30 20x20x4 MERV 8 G4 ePM10 50% 492x 492x 95 2363/ 70 1.76 0.3

59413004 30/30 20x16x4 MERV 8 G4 ePM10 50% 390x 492x 95 1870/ 70 1.46 0.25

59413005 30/30 25x16x4 MERV 8 G4 ePM10 50% 390x 619x 95 2363/ 70 1.83 0.25

59413006 30/30 25x20x4 MERV 8 G4 ePM10 50% 492x 619x 95 2958/ 70 2.19 0.45

59413008 30/30 24x20x4 MERV 8 G4 ePM10 50% 492x 594x 95 2839/ 70 2.11 1.02

59413010 30/30 25x25x4 MERV 8 G4 ePM10 50% 619x 619x 95 3689/ 70 2.79 0.5

4
General Ventilation Filters | Pleated Panel Filters

Dual10
Advantages
• Water resistant frame board • Welded Steel Grid with
• Diagonal Support Corrosion Inhibitor
• Radial Pleats • Built Strong
• Proprietary Dual High Lofted
Fibers

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Water resistant cardboard
Media: Dual layered, blended polyester
Max Temperature (°C): 90ºC
Installation Options: Front and side access housings and frames are
available, Type 8, Type L, and FC Housings.
Comment: Fire rating: UL 900

ASHRAE 52.2- Dimensions WxHxD Airflow/pressure drop Energy


Art. No. Type ISO16890 Area (m²) Weight (kg) Energy class
2017 (mm) (m³/h/Pa) consumption

540F-FG406331005 Dual10 24x24x2 MERV 9 ePM10 55% 594x 594x 44 3400/ 75 1.56 0,8 1008 D

540F-FG406331012 Dual10 24x20x2 MERV 9 ePM10 55% 495x 594x 44 2839/ 75 1.30 0,7 D

540F-FG406331002 Dual10 20x20x2 MERV 9 ePM10 55% 495x 495x 44 2363/ 75 1.09 0,6 D

540F-FG406331006 Dual10 24x12x2 MERV 9 ePM10 55% 289x 594x 44 1700/ 75 0.78 0,4 D

540F-FG406332005 Dual10 24x24x4 MERV 9 ePM10 55% 594x 594x 95 3400/ 68 2.47 1.50 1020 D

540F-FG406332012 Dual10 24x20x4 MERV 9 ePM10 55% 492x 594x 95 2839/ 68 2.05 1.10 D

540F-FG406332002 Dual10 20x20x4 MERV 9 ePM10 55% 492x 492x 95 2363/ 68 1.70 1.00 D

540F-FG406332006 Dual10 24x12x4 MERV 9 ePM10 55% 289x 594x 95 1700/ 68 1.24 0.75 D

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
General Ventilation Filters | Pleated Panel Filters

AP WR
Advantages
• Superior moisture resistance • Bonded into case to eliminate
• A multi-layered noncellulose air bypass
media, repels water, captures • Large media surface
dust, lint, pollen and other • High media surface area
particulate contaminants

Application: Prevention of dust and dirt build up on heating/cooling


coils within ventilation systems
Frame: Water resistant cardboard
Media: Glass fiber
Rec. final pressure drop: 250 Pa
Max Temperature (°C): 70°C
Installation Options: Holding frames: Front and side access housings
and frames are available, Type 8 and FC Housings

Art. No. Type ASHRAE 52.2-2017 EN779 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

125343005 AP WR 24x24x2 MERV 7 G4 595x 595x 44 3400/ 60 2,61 0.65

125343006 APWR 24x12x2 MERV 7 G4 289x 595x 44 1700/ 60 1,27 0.33

402137001 AP WR 24x24x4 MERV 7 G4 595x 595x 95 3400/ 55 4,24 1.2

402137002 AP WR 24x12x4 MERV 7 G4 289x 595x 95 1700/ 55 2.12 0.6


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

4
General Ventilation Filters | Pleated Panel Filters

CityPleat
Advantages
• “2-in-1” filtration solution; • Ideal for filtering low
particulate and molecular concentrations of most
• Removal of solid and gaseous external and internal source
contaminants in one filter pollutants
stage • Can be used to upgrade
existing installations

Application: High efficiency particle filtration for deodarisation and


removal of gas pollutants, used for filtration in offices, airports
Frame: Water resistant cardboard
Media: Synthetic/Activated Carbon
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 50
Pa or initial pressure drop x3 (whichever is lower)
Max. final pressure drop: 250 Pa
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 50ºC
Relative Humidity max: 30% - 70%
Installation Options: Front and side access housings and frames are
available
Comment: Ozone removal efficiency: 50 - 70% depending on model
and air flow. All values are +-15%

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

5103001 CityPleat-100-594x594x44 G4 Coarse 65% 594x 594x 44 2000/ 140 1

5103007 CityPleat-100-289x594x44 G4 Coarse 65% 289x 594x 44 1000/ 140 0,5

5103004 CityPleat-200-289x594x44 G4 Coarse 65% 289x 594x 44 1700/ 140 0,9

5103005 CityPleat-200-594x594x44 G4 Coarse 65% 594x 594x 44 3400/ 140 1,8

5103011 CityPleat-200-594x594x95 G4 Coarse 65% 594x 594x 95 3400/ 125 2

5103008 CityPleat-200-289x594x95 G4 Coarse 65% 289x 594x 95 1700/ 125 1

5103010 CityPleat-480-594x594x95 G4 Coarse 65% 594x 594x 95 3400/ 90 3,8

5103009 CityPleat-480-289x594x95 G4 Coarse 65% 289x 594x 95 1700/ 90 1,9


Full size test in Camfil molecular filtration test rig

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

4
General Ventilation Filters | Pleated Panel Filters

ECO Moisture Separator


Advantages
• Pre-drilled weeping holes for • Optional coalescer pad
drainage or reclaim of valuable available for increased
process oils efficiency

Application: High moisture situations in commercial or industrial


processes, or oil-laden industrial applications. Includes weeping
holes for drainage or reclaim of airborne oil or mists.
Frame: Stainless steel, Galvanised steel
Rec. final pressure drop: 250 Pa when operated at 2.5 m/s. System
design may dictate alternative changeout point
Comment: Media: Multi layered galvanized steel wire or stainless
steel wire
Efficiency: 98%+ on droplets 20 microns and larger
Airflow operating range: Velocity of 2.25 m/s to 2.75 m/s, consult
factory outside of this range.

Airflow/pressure drop
Art. No. Type Dimensions WxHxD (mm) Weight (kg)
(m³/h/Pa)

064649-002 EcoMoister-For built-up banks 289x 594x 95 1700/ 4,5

064649-003 EcoMoister-For built-up banks 594x 289x 95 1700/ 4,5

064649-004 EcoMoister-For side access housings(includes sealing gasket on vertical side} 594x 594x 95 3400/ 8,6

064649-005 EcoMoister-For side access housings(includes sealing gasket on vertical side} 289x 594x 95 1700/ 4,5

064649-006 EcoMoister-For side access housings(includes sealing gasket on vertical side} 594x 289x 95 1700/ 4,5

098512-001 EcoMoister-For built-up banks 594x 594x 95 3400/ 8,6

098512-002 EcoMoister-For built-up banks 594x 289x 95 1700/ 4,5

098512-003 EcoMoister-For built-up banks 289x 594x 95 1700/ 4,5

098512-004 EcoMoister-For side access housings(includes sealing gasket on vertical side} 594x 594x 95 3400/ 8,6

098512-005 EcoMoister-For side access housings(includes sealing gasket on vertical side} 594x 289x 95 1700/ 4,5

098512-006 EcoMoister-For side access housings(includes sealing gasket on vertical side} 289x 594x 95 1700/ 4,5

064649-001 EcoMoister-For built-up banks 594x 594x 95 3400/ 8,6


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

4
General Ventilation Filters | Pleated Panel Filters

EcoPleat G
Advantages
• Ultra compact panel filter with • Long operating life with large
ePM1 and ePM10 efficiencies dust holding capacity
• Low pressure drop thanks to • Less frequent changes
large surface area • Fully combustible plastic frame

Application: Air conditioning or industrial processing systems and


for mini air conditioning systems, individual modules, ventilation
equipment
Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Dimensions: Filter front dimensions according EN 15805
Max. final pressure drop: 350 Pa
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

Due to its small size, EcoPleat G can be installed in most air handling units. Close pleats ensure low energy consumption, a large filter
area and low pressure drop.
The filter media used in EcoPleat G has very fine fibres that guarantee efficient removal of submicron particles throughout the filter’s
lifetime. The removal efficiency can be as high as 10 times the efficiency of G4 pre-filters with efficiencies ranging from M5 to F9.
The water-resistant plastic frame provides extra assurance in high-humidity applications. Due to its frame, EcoPleat G is also 50%
lighter than the metal frame version for a smaller environmental impact and easier handling.
EcoPleat G is well suited for commercial and residential air handling units, as well as other stand-alone systems for comfort
applications.
EcoPleat is also available with cardboard and metal frames.

Airflow/pressure drop
Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
(m³/h/Pa)

2715001 3GPPS-12242-M6 MERV A 11A M6 ePM10 70% 287x 592x 48 950/ 50 2,9 2

2715002 3GPPS-20242-M6 MERV A 11A M6 ePM10 70% 490x 592x 48 1500/ 50 4.9 2.5

2715003 3GPPS-24242-M6 MERV A 11A M6 ePM10 70% 592x 592x 48 2900/ 75 5,3 3

2715004 3GPPS-12242-F7 MERV A 13A F7 ePM1 55% 287x 592x 48 1450/ 110 2,9 1,5

2715005 3GPPS-20242-F7 MERV A 13A F7 ePM1 55% 490x 592x 48 1500/ 75 4.9 2.5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
2715006 3GPPS-24242-F7 MERV A 13A F7 ePM1 55% 592x 592x 48 2900/ 110 5,8 3

2715007 3GPPS-12242-F8 MERV A 14A F8 ePM1 70% 287x 592x 48 1450/ 160 2,8 1,5

2715008 3GPPS-20242-F8 MERV A 14A F8 ePM1 70% 490x 592x 48 1500/ 85 4.9 2.5

2715009 3GPPS-24242-F8 MERV A 14A F8 ePM1 70% 592x 592x 48 2900/ 160 6,3 3

2714001 3GPPS-12244-M6 MERV A 11A M6 ePM10 70% 287x 592x 96 1450/ 70 5,1 3

2714002 3GPPS-20244-M6 MERV A 11A M6 ePM10 70% 490x 592x 96 2800/ 105 9.9 3.5

2714003 3GPPS-24244-M6 MERV A 11A M6 ePM10 70% 592x 592x 96 2900/ 70 10,2 4

2714004 3GPPS-12244-F7 MERV A 13A F7 ePM1 55% 287x 592x 96 1450/ 100 5,7 3

2714005 3GPPS-20244-F7 MERV A 13A F7 ePM1 55% 490x 592x 96 2800/ 135 9.9 3.5

2714006 3GPPS-24244-F7 MERV A 13A F7 ePM1 55% 592x 592x 96 2900/ 100 11,5 4

2714007 3GPPS-12244-F8 MERV A 14A F8 ePM1 70% 287x 592x 96 1450/ 105 4,4 3

2714008 3GPPS-20244-F8 MERV A 14A F8 ePM1 70% 490x 592x 96 2800/ 145 9.9 3.5

2714009 3GPPS-24244-F8 MERV A 14A F8 ePM1 70% 592x 592x 96 2900/ 105 12,8 4

2714517 3GPPS-24244-F9 MERV A 15A F9 ePM1 80% 592x 592x 96 3400/ 160 11.9 4

2714518 3GPPS-12244-F9 MERV A 15A F9 ePM1 80% 287x 592x 96 1700/ 160 5.8 3

2714520 3GPPS-20244-F9 MERV A 15A F9 ePM1 80% 490x 592x 96 2800/ 160 9.9 3.5
Other sizes available on request

4
General Ventilation Filters | Pleated Panel Filters

EcoPleat ProSafe
Advantages
• ProSafe certified for Food • Free of bisphenol-A, phthalate
Beverage, Life Science or close and formaldehyde
to product applications • Tested for food safety acc. to
• Chemically resistant to EC 1935:2004
decontamination, inactivation • Manufactured and packed in a
and cleaning agent controlled environment
• Microbial inert components • Packaging suitable for
acc. to ISO 846 cleanroom unpacking
• Compliant to VDI 6022

Application: Industrial processing systems, ventilation equipment,


air intake and return air
Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
EFFICIENCY GUARANTEE
Dimensions: Filter front dimensions according EN 15805
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
Comment: Option: PU gasket (ProSafe certified)
Note: Unit packaging hygienic bag

ASHRAE 52.2- Airflow/pressure drop Weight


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²)
2017 (m³/h/Pa) (kg)

2718001 3GPPS-12242-M6 MERV 11 M6 ePM10 70% 287x 592x 48 950/ 50 2.6 0.94

2718002 3GPPS-20242-M6 MERV 11 M6 ePM10 70% 490x 592x 48 1500/ 50 4.53 1.41

2718003 3GPPS-24242-M6 MERV 11 M6 ePM10 70% 592x 592x 48 1900/ 50 5.47 1.66

2718101 3GPPS-12242-F7 MERV 13 F7 ePM1 55% 287x 592x 48 950/ 75 3.14 0.97

2718102 3GPPS-20242-F7 MERV 13 F7 ePM1 55% 490x 592x 48 1500/ 75 5.47 1.46

2718103 3GPPS-24242-F7 MERV 13 F7 ePM1 55% 592x 592x 48 1900/ 75 6.62 1.72

2718201 3GPPS-12242-F8 MERV 14 F8 ePM1 70% 287x 592x 48 950/ 85 3.43 0.97

2718202 3GPPS-20242-F8 MERV 14 F8 ePM1 70% 490x 592x 48 1500/ 85 5.92 1.46

2718203 3GPPS-24242-F8 MERV 14 F8 ePM1 70% 592x 592x 48 1900/ 85 7.21 1.72
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2718302 3GPPS-12242-F9 MERV 15 F9 ePM1 80% 287x 592x 48 1500/ 100 5.9

2718301 3GPPS-24242-F9 MERV 15 F9 ePM1 80% 592x 592x 48 950/ 100 3.4

2718303 3GPPS-20242-F9 MERV 15 F9 ePM1 80% 490x 592x 48 1900/ 100 7.2

2718501 3GPPS-12244-M6 MERV 11 M6 ePM10 70% 287x 592x 96 1700/ 105 5.26 1.67

2718502 3GPPS-20244-M6 MERV 11 M6 ePM10 70% 490x 592x 96 2800/ 105 9.05 2.63

2718503 3GPPS-24244-M6 MERV 11 M6 ePM10 70% 592x 592x 96 3400/ 105 11.05 3.12

2718601 3GPPS-12244-F7 MERV 13 F7 ePM1 55% 287x 592x 96 1700/ 135 5.79 1.74

2718602 3GPPS-20244-F7 MERV 13 F7 ePM1 55% 490x 592x 96 2800/ 135 10.1 2.74

2718603 3GPPS-24244-F7 MERV 13 F7 ePM1 55% 592x 592x 96 3400/ 135 12.21 3.25

2718701 3GPPS-12244-F8 MERV 14 F8 ePM1 70% 287x 592x 96 1700/ 145 6.42 1.74

2718702 3GPPS-20244-F8 MERV 14 F8 ePM1 70% 490x 592x 96 2800/ 145 11.05 2.74

2718703 3GPPS-24244-F8 MERV 14 F8 ePM1 70% 592x 592x 96 3400/ 145 13.47 3.25

2718802 3GPPS-12244-F9 MERV 15 F9 ePM1 80% 287x 592x 96 1700/ 160 7.47 1.74

2718801 3GPPS-24244-F9 MERV 15 F9 ePM1 80% 592x 592x 96 3400/ 160 15.89 3.25

2718803 3GPPS-20244-F9 MERV 15 F9 ePM1 80% 490x 592x 96 2800/ 160 13.05 2.74
General Ventilation Filters | Pleated Panel Filters

Airopac ® Green
Advantages
• Low pressure drop • lncinerable
• Water resistant beverage board • Rigid design concept
• Large surface area • High dust holding capacity

Application: Air conditioning applications and preparatory filtration


in clean rooms
Frame: Water resistant cardboard
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Rec. final pressure drop: 450 Pa (suggested economical change
point 250 Pa)
Max Temperature (°C): 70°C maximum in continuous service
Installation Options: Front and side access housing and frames are
available
Comment: Holding frames: Type 8 and FC Housings

EFFICIENCY GUARANTEE

Airflow/pressure drop (m³/h/


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Weight (kg)
Pa)

2700001 3GP-24244-60 M6 ePM10 70% 594x 594x 95 3400/ 120 2.3

2700002 3GP-20244-60 M6 ePM10 70% 492x 594x 95 2810/ 120 1.9

2700003 3GP-12244-60 M6 ePM10 70% 289x 594x 95 1645/ 120 1.2

2700004 3GP-20204-60 M6 ePM10 70% 492x 492x 95 2325/ 120 1.5

2700013 3GP-24244-90 F7 ePM1 55% 594x 594x 95 3400/ 130 2.3

2700014 3GP-20244-90 F7 ePM1 55% 492x 594x 95 2810/ 130 1.9

2700015 3GP-12244-90 F7 ePM1 55% 289x 594x 95 1645/ 130 1.2

2700016 3GP-20204-90 F7 ePM1 55% 492x 492x 95 2325/ 130 1.5

2700025 3GP-24244-95 F8 ePM1 70% 594x 594x 95 3400/ 150 2.3

2700026 3GP-20244-95 F8 ePM1 70% 492x 594x 95 2810/ 150 1.9

2700027 3GP-12244-95 F8 ePM1 70% 289x 594x 95 1645/ 150 1.2

2700028 3GP-20204-95 F8 ePM1 70% 492x 492x 95 2325/ 150 1.5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

5
General Ventilation Filters | Compact Filters (Header Frame)

Opakfil ES
Advantages
• Extended operating life with • Very low energy consumption
best total cost of ownership and high dust holding capacity
(TCO) • Lowest labour cost thanks to
• Light and robust filter less frequent changes
construciton • Aerodynamic radial design for
improved air flow

Application: Air conditioning applications and preparatory filtration


in clean rooms
Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
Comment:
only

Airflow/pressure drop Energy


Art. No. Type ASHRAE 52.2:2017 EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg) Energy class
(m³/h/Pa) consumption

2400501 OPGP-M6-0592/0592/0296-ES-00 MERV A 11A M6 ePM10 70% 592x 592x 296 3400/ 60 17 5 770 B

2400502 OPGP-M6-0592/0490/0296-ES-00 MERV A 11A M6 ePM10 70% 592x 490x 296 2800/ 60 14 4 B

2400503 OPGP-M6-0592/0287/0296-ES-00 MERV A 11A M6 ePM10 70% 592x 287x 296 1700/ 60 8 3 B

2400601 OPGP-F7-0592/0592/0296-ES-00 MERV A 13A F7 ePM1 60% 592x 592x 296 3400/ 65 17 5 838 A+

2400602 OPGP-F7-0592/0490/0296-ES-00 MERV A 13A F7 ePM1 60% 592x 490x 296 2800/ 65 14 4 A+

2400603 OPGP-F7-0592/0287/0296-ES-00 MERV A 13A F7 ePM1 60% 592x 287x 296 1700/ 65 8 3 A+

2400701 OPGP-F8-0592/0592/0296-ES-00 MERV A 14A F8 ePM1 70% 592x 592x 296 3400/ 75 17 5 1020 A
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2400702 OPGP-F8-0592/0490/0296-ES-00 MERV A 14A F8 ePM1 70% 592x 490x 296 2800/ 75 14 4 A

2400703 OPGP-F8-0592/0287/0296-ES-00 MERV A 14A F8 ePM1 70% 592x 287x 296 1700/ 75 8 3 A

2400801 OPGP-F9-0592/0592/0296-ES-00 MERV A 15A F9 ePM1 80% 592x 592x 296 3400/ 90 17 5 1212 A

2400802 OPGP-F9-0592/0490/0296-ES-00 MERV A 15A F9 ePM1 80% 592x 490x 296 2800/ 90 14 4 A

2400803 OPGP-F9-0592/0287/0296-ES-00 MERV A 15A F9 ePM1 80% 592x 287x 296 1700/ 90 8 3 A
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

5
General Ventilation Filters | Compact Filters (Header Frame)

Opakfil ProSafe ES
Advantages
• ProSafe certified for Food • Free of bisphenol-A, phthalate
Beverage, Life Science or close and formaldehyde
to product applications • Tested for food safety acc. to
• Chemically resistant to EC 1935:2004
decontamination, inactivation • Manufactured and packed in a
and cleaning agent controlled environment
• Microbial inert components • Packaging suitable for
acc. to ISO 846 cleanroom unpacking
• Compliant to VDI 6022

Application: Air conditioning applications and preparatory filtration


in clean rooms
Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
EFFICIENCY GUARANTEE
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

Food and Beverage or Life-Science activities have set new standards in product quality and therefore require specific characteristics
regarding process definition.
Camfil, as the leader in clean air solutions and air filtration, has developed the complete ProSafe range of products designed for the
most demanding processes, including safety, traceability and audits requirement.

Airflow/pressure drop Energy


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg) Energy class
(m³/h/Pa) consumption

2400501-P OPGP-M6-0592/0592/0296-ES-PS-00 M6 ePM10 70% 592x 592x 296 3400/ 60 17 5 770 B

2400502-P OPGP-M6-0592/0490/0296-ES-PS-00 M6 ePM10 70% 592x 490x 296 2800/ 60 14 4 B

2400503-P OPGP-M6-0592/0287/0296-ES-PS-00 M6 ePM10 70% 592x 287x 296 1700/ 60 8 3 B

2400601-P OPGP-F7-0592/0592/0296-ES-PS-00 F7 ePM1 60% 592x 592x 296 3400/ 65 17 5 838 A+

2400602-P OPGP-F7-0592/0490/0296-ES-PS-00 F7 ePM1 60% 592x 490x 296 2800/ 65 14 4 A+

2400603-P OPGP-F7-0592/0287/0296-ES-PS-00 F7 ePM1 60% 592x 287x 296 1700/ 65 8 3 A+

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
2400701-P OPGP-F8-0592/0592/0296-ES-PS-00 F8 ePM1 70% 592x 592x 296 3400/ 75 17 5 1020 A

2400702-P OPGP-F8-0592/0490/0296-ES-PS-00 F8 ePM1 70% 592x 490x 296 2800/ 75 14 4 A

2400703-P OPGP-F8-0592/0287/0296-ES-PS-00 F8 ePM1 70% 592x 287x 296 1700/ 75 8 3 A

2400801-P OPGP-F9-0592/0592/0296-ES-PS-00 F9 ePM1 80% 592x 592x 296 3400/ 90 17 5 1212 A

2400802-P OPGP-F9-0592/0490/0296-ES-PS-00 F9 ePM1 80% 592x 490x 296 2800/ 90 14 4 A

2400803-P OPGP-F9-0592/0287/0296-ES-PS-00 F9 ePM1 80% 592x 287x 296 1700/ 90 8 3 A


Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019. Certification and test results available online.
General Ventilation Filters | Compact Filters (Header Frame)

Opakfil ST
Advantages
• Long operating life • Aerodynamic radial design
• Light and robust • Less frequent changes
• Long performance

Application: Air conditioning applications


Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available
EFFICIENCY GUARANTEE
Comment:

ASHRAE Airflow/pressure Energy Energy


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
52.2:2017 drop (m³/h/Pa) consumption class

2410501 OPGP-M6-0592/0592/0296-ST-O0 MERV A 11A M6 ePM10 70% 592x 592x 296 3400/ 60 13 4 952 D

2410502 OPGP-M6-0592/04 90/0296-ST-O0 MERV A 11A M6 ePM10 70% 592x 490x 296 2800/ 60 10 3 D

2410503 OPGP-M6-0592/0287/0296-ST-00 MERV A 11A M6 ePM10 70% 592x 287x 296 1700/ 60 6 2 D

2410601 OPGP-F7-0592/0592/0296-ST-O0 MERV A 13A F7 ePM1 55% 592x 592x 296 3400/ 70 13 4 895 A

2410602 OPGP -F7-0592/0490/0296-ST-O0 MERV A 13A F7 ePM1 55% 592x 490x 296 2800/ 70 10 3 A

2410603 OPGP-F7-0592/0287/0296-ST-O0 MERV A 13A F7 ePM1 55% 592x 287x 296 1700/ 70 6 2 A

2410701 OPGP-F8-0592/0592/0296-ST-O0 MERV A 14A F8 ePM1 70% 592x 592x 296 3400/ 90 13 4 1178 B

2410702 OPGP-F8-0592/0490/0296-ST-O0 MERV A 14A F8 ePM1 70% 592x 490x 296 2800/ 90 10 3 B

2410703 OPGP-F8-059 2/0287/0296-ST-O0 MERV A 14A F8 ePM1 70% 592x 287x 296 1700/ 90 6 2 B

2410801 OPGP-F9-0592/0592/0296-ST-O0 MERV A 15A F9 ePM1 80% 592x 592x 296 3400/ 110 13 4 1507 C

2410802 OPGP -F9-0592/0490/0296-ST-O0 MERV A 15A F9 ePM1 80% 592x 490x 296 2800/ 110 10 3 C
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2410803 OPGP-F9-0592/0287/0296-ST-O0 MERV A 15A F9 ePM1 80% 592x 287x 296 1700/ 110 6 2 C
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

5
General Ventilation Filters | Compact Filters (Header Frame)

Opakfil 2V
Advantages
• Light and robust • Fully incinerable

Application: Air conditioning applications and preparatory filtration


in clean rooms
Frame: ABS
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
Pa or initial pressure drop x3 (whichever is lower)
Max airflow: 1,25 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available

EFFICIENCY GUARANTEE

Dimensions WxHxD Airflow/pressure drop


Art. No. Type ASHRAE 52.2:2017 EN779 ISO16890 Area (m²) Weight (kg)
(mm) (m³/h/Pa)

2481001 OPGP-M6-0592/0592/0268-2V-20-00 MERV A 11A M6 ePM10 70% 592x 592x 268 3400/ 85 8 3

2481002 OPGP-M6-0592/0490/0268-2V-20-00 MERV A 11A M6 ePM10 70% 592x 490x 268 2800/ 85 7 2,5

2481003 OPGP-M6-0592/0287/0268-2V-20-00 MERV A 11A M6 ePM10 70% 592x 287x 268 1700/ 85 4 2

2481004 OPGP-F7-0592/0592/0268-2V-20-00 MERV A 13 A F7 ePM1 55% 592x 592x 268 3400/ 100 8 3

2481005 OPGP-F7-0592/0490/0268-2V-20-00 MERV A 13A F7 ePM1 55% 592x 490x 268 2800/ 100 7 2,5

2481006 OPGP-F7-0592/0287/0268-2V-20-00 MERV A 13A F7 ePM1 55% 592x 287x 268 1700/ 100 4 2

2481007 OPGP-F8-0592/0592/0268-2V-20-00 MERV A 14A F8 ePM1 70% 592x 592x 268 3400/ 120 8 3

2481008 OPGP-F8-0592/0490/0268-2V-20-00 MERV A 14A F8 ePM1 70% 592x 490x 268 2800/ 120 7 2,5

2481009 OPGP-F8-0592/0287/0268-2V-20-00 MERV A 14A F8 ePM1 70% 592x 287x 268 1700/ 120 4 2

2481010 OPGP-F9-0592/0592/0268-2V-20-00 MERV A 15A F9 ePM1 80% 592x 592x 268 3400/ 230 8 3

2481011 OPGP-F9-0592/0490/0268-2V-20-00 MERV A 15A F9 ePM1 80% 592x 490x 268 2800/ 230 7 2.5

2481012 OPGP-F9-0592/0287/0268-2V-20-00 MERV A 15A F9 ePM1 80% 592x 287x 268 1700/ 230 4 2

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
25mm header frame (depth with 272 mm is available on request)
Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019

5
General Ventilation Filters | Compact Filters (Header Frame)

CityCarb I
Advantages
• “2-in-1” filtration solution; • Ideal for filtering moderate
particulate and molecular concentrations of most
• Removal of solid and gaseous external and internal source
contaminants in one filter pollutants
stage • Can be used to upgrade
existing installations

Application: Particle and corrosive acids removal in museums, art


galleries, libraries etc
Type: Loose Fill Cylinder
Frame: Plastic moulded
Gasket: One piece PU gasket (01 in the standard version)
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Dimensions: Filter front dimensions according EN 15805
TE
STED
Rec. final pressure drop acc. EN 13053: Initial pressure drop + 100
ISO16890 Pa or initial pressure drop x3 (whichever is lower)
ACCORDI NG
TO
Max airflow: 1,25 x nominal flow
Max Temperature (°C): -21 to 60
Relative Humidity max: 70%
Installation Options: Front and side access housings and frames are
available
EFFICIENCY GUARANTEE

A compact filter with an additional molecular filtration media layer to provide enhanced IAQ through combined particle filtration and
gas filtration.

CityCarb is the ultimate solution when a high performance compact filter and a high performance molecular (gas, odour) filter must
be installed in a single location. CityCarb filter can easily be fitted into new or existing standard filter frames. Particle filtration media
is combined with an exclusive “Broad Spectrum” carbon media that exploits the benefits of “Rapid Adsorption Dynamics” (RAD) to
remove a very wide range of VOCs and odours. Molecular pollutants are released from both external sources (traffic fumes, power
generation , industry) and internal sources (building construction and finish materials, wooden materials, carpets, cleaning agents etc).

The filter should be replaced when the pressure loss exceeds the maximum allowable value for the ventilation system or after a
maximum of one year. In accordance with good practice, used CityCarb filters should be bagged immediately after removal and
disposed of by the appropriate route.

Dimensions WxHxD Airflow/pressure drop


Art. No. Type EN779 ISO16890 Area (m²) Weight (kg) ePM1 ePM1min ePM2,5 ePM2,5min ePM10
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

(mm) (m³/h/Pa)

56710001 CityCarb-I 242412-01PU F7 ePM1 70% 592x 592x 292 3400/ 130 8 9,3 71 55 79 68 93

56710002 CityCarb-I 242012-01PU F7 ePM1 70% 592x 490x 292 2800/ 130 6,6 6,8

56710003 CityCarb-I 241212-01PU F7 ePM1 70% 592x 287x 292 1500/ 130 3,8 4,8

5
General Ventilation Filters | Compact Filters (Header Frame)

CitySorb
Advantages
• Compact filter with molecular • Ideal for filtering moderate
media concentrations of most
• Removal of gaseous external and internal source
contaminants pollutants
• Can be used to upgrade
existing installations

Application: Adsorption of odours and gases in air conditioning


applications
Frame: Plastic moulded
Gasket: One piece PU gasket (01 in the standard version)
Media: Activated Carbon
Separator: Hot-melt
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop: 2x Initial pressure drop
Max Temperature (°C): 40º C
Relative Humidity max: 70%
Installation Options: Front and side access housings and frames are
available

The CitySorb filter utilizes a highly effective broad spectrum carbon media to ensure removal of a very wide range of airborne
chemicals.
The broad spectrum carbon operates with a Rapid Adsorption Dynamics (RAD) mechanism that is specifically designed to be highly
efficient against the multiple chemicals that are typically present in low or moderate concentrations in city-centre buildings or other
locations.
CitySorb is an effective ozone filter with a 70% ozone removal efficiency or Oz7 ozone removal rating according to the unique Camfil
system.

Art. No. Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

56700003 CitySorb 242412-01PU 592x 592x 292 3400/ 80 8 10.8

56700201 CitySorb 242012-01PU 592x 490x 292 2800/ 80 6,6 9.2

56700005 CitySorb 241212-01PU 592x 287x 292 1500/ 80 3,5 5.4

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

5
General Ventilation Filters | Compact Filters (Header Frame)

CitySorb DP
Advantages
• Standard design for removal of • Compact solution with low
acids, alkalines, organic smells pressure dropFrame is also
and condensable organics. available in box type other than
single / double header

Application: Remove of diverse gaseous contaminant


Frame: Galvanised steel
Relative Humidity max: 30% - 70%
Comment: Frame: Galvanised steel (other on request). BH: Double
Header, PH: Single Header, DH: Box Type
Media: Type 201: nonwoven fiber material with carbon for removal
of organic smells and condensable organics. Type 202: nonwoven
fiber material with impregnated carbon for removal of acids. Type
204: nonwoven fiber material with impregnated carbon for removal
of alkalines
Recommended temperature: 0 - 40°C

Art. No. Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

5640018 CitySorb-DP-201-242412-BH 592x 592x 292 3400/ 75 15

5642000 CitySorb-DP-201-241212-BH 287x 592x 292 1700/ 75 8

5640024 CitySorb-DP-201-242412-PH 592x 592x 292 3400/ 75 15

5645000 CitySorb-DP-201-241212-PH 287x 592x 292 1700/ 75 8

5640001 CitySorb-DP-202-242412-BH 592x 592x 292 3400/ 75 15

5640010 CitySorb-DP-202-241212-BH 287x 592x 292 1700/ 75 8

5640006 CitySorb-DP-202-242412-PH 592x 592x 292 3400/ 75 15

5640004 CitySorb-DP-202-241212-PH 287x 592x 292 1700/ 75 8

5640002 CitySorb-DP-204-242412-BH 592x 592x 292 3400/ 75 15

5640012 CitySorb-DP-204-241212-BH 287x 592x 292 1700/ 75 8

5640011 CitySorb-DP-204- 242412 -PH 592x 592x 292 3400/ 75 15

5640005 CitySorb-DP-204-2 41212-PH 287x 592x 292 1700/ 75 8


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

5
General Ventilation Filters | Compact Filters (Box Type)

Durafil ® ESB
Advantages
• Dual headers for front loading • Lowest initial pressure drop of
filter installations any dual header box style air
• Lowest Life-Cycle Cost (LCC) filter
filter available • Built-in spacer for pleated
• Fine fiber ensures that the prefilters
filter will maintain efficiency
throughout its life in the
system

Application: Built-up filter banks, rooftops, split systems, free-


standing units, package systems and air handlers that require a filter
with dual headers
Type: Box Filter
Frame: Plastic
Media: Glass fiber
Rec. final pressure drop: 450 Pa (suggested economical change
point 250 Pa)
EFFICIENCY GUARANTEE
Rec. final pressure drop: 2x Initial pressure drop
Max Temperature (°C): 70°C
Comment: Fire rating: UL 900

ASHRAE Airflow/pressure drop


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
52.2-2017 (m³/h/Pa)

2495001 DU4V-ESB-242412-M6 MERV 11 M6 ePM10 70% 592x 592x 315 3400/ 65 18.3 4.97

2495002 DU4V-ESB-242012-M6 MERV 11 M6 ePM10 70% 592x 492x 315 2550/ 65 15 3.96

2495003 DUV4V-ESB-241212-M6 MERV 11 M6 ePM10 70% 592x 289x 315 1700/ 65 8.3 2.6

2495004 DUV4V-ESB-242412-F7 MERV 13 F7 ePM1 55% 592x 592x 315 3400/ 80 18.3 6.62

2495005 DUV-ESB-242012-F7 MERV 13 F7 ePM1 55% 592x 592x 315 2550/ 80 15 3.96

2495006 DU4V-ESB-241212-F7 MERV 13 F7 ePM1 55% 592x 289x 315 1700/ 80 8.3 2.6

2495007 DU4V-ESB-242412-F8 MERV 14 F8 ePM1 70% 592x 592x 315 3400/ 85 18.3 5.71

2495008 DU4V-ESB-242012-F8 MERV 14 F8 ePM1 70% 592x 492x 315 2550/ 85 15 3.96

2495009 DU4V-ESB-241212-F8 MERV 14 F8 ePM1 70% 592x 289x 315 1700/ 85 8.3 2.6

2495010 DU4V-ESB-242412-F9 MERV 15 F9 ePM1 80% 592x 592x 315 3400/ 115 18.3 6.49

2495011 DU4V-ESB-242012-F9 MERV 15 F9 ePM1 80% 592x 492x 315 2550/ 115 15 3.96

2495012 DU4V-ESB-241212-F9 MERV 15 F9 ePM1 80% 592x 289x 315 1700/ 115 8.3 2.6

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

5
General Ventilation Filters | Compact Filters (Box Type)

Opakair
Advantages
• Long lifespan • Fast, simple filterchange
• High efficiency • Compact design

Application: High air flow air conditioning and process air


applications
Frame: Galvanised steel
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Dimensions: Filter front dimensions according EN 15805
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and safechange
systems are available
Comment: Fire rating: DIN 53438 Class F1

EFFICIENCY GUARANTEE

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

2420003 Opakair-90 F7 ePM1 55% 610x 610x 292 4500/ 105 20 18

2420004 Opakair-90 F7 ePM1 55% 305x 610x 292 2250/ 105 10 9

2420005 Opakair-95 F8 ePM1 70% 610x 610x 292 4500/ 130 20 18

2420006 Opakair-95 F8 ePM1 70% 305x 610x 292 2250/ 130 10 9


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
General Ventilation Filters | Compact Filters (Box Type)

Airopac ® 3GGM
Advantages
• Large surface area • Ultra compact
• Savings in operating costs • High dust holding capacity

Application: Air conditioning or industrial processing systems and


for mini air conditioning systems, individual modules.
Type: Compact Pleated Filter
Frame: Galvanised steel
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Rec. final pressure drop: 450 Pa (suggested economical change
point 250 Pa)
Max Temperature (°C): 70ºC
Comment: Fire rating: DIN 53438 Class Fl .

EFFICIENCY GUARANTEE

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

2100001 3GGM-24246-60 M6 ePM10 70% 610x 610x 150 3400/ 65 6.8

2100002 3GGM-20246-60 M6 ePM10 70% 508x 610x 150 2850/ 65 5.7

2100003 3GGM-12246-60 M6 ePM10 70% 305x 610x 150 1700/ 65 4

2100004 3GGM-20206-60 M6 ePM10 70% 508x 508x 150 2375/ 65 5

2100009 3GGM--24246-90 F7 ePM1 55% 610x 610x 150 3400/ 100 6.8

2100010 3GGM-20246-90 F7 ePM1 55% 508x 610x 150 2850/ 100 5.7

2100011 3GGM-12246-90 F7 ePM1 55% 305x 610x 150 1700/ 100 4

2100012 3GGM-20206-90 F7 ePM1 55% 508x 508x 150 2375/ 100 5

2100017 3GGM-24246-95 F8 ePM1 70% 610x 610x 150 3400/ 130 6.8

2100018 3GGM-20246-95 F8 ePM1 70% 508x 610x 150 2850/ 130 5.7

2100019 3GGM-12246-95 F8 ePM1 70% 305x 610x 150 1700/ 130 4

2100020 3GGM-20206-95 F8 ePM1 70% 508x 508x 150 2375/ 130 5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6
General Ventilation Filters | Compact Filters (Box Type)

Airopac ® 3GGMHF
Advantages
• Large surface area • Ultra compact
• Savings in operating costs • High dust holding capacity
• Less frequent changes

Application: Air conditioning or industrial processing systems and


for mini air conditioning systems, individual modules.
Type: Compact Pleated Filter
Frame: Galvanised steel
Gasket: Polyurethane
Media: Glass fiber
Separator: Hot-melt Separator Technology
Sealant: Polyurethane
Rec. final pressure drop: 450 Pa
Max airflow: 1,15 x nominal flow
Max Temperature (°C): 70ºC
Comment: Fire rating: DIN 53438 Class F1

EFFICIENCY GUARANTEE

ASHRAE 52.2- Airflow/pressure drop


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
2017 (m³/h/Pa)

2120001 3GGMHF-24245-60 MERV 11 M6 ePM2,5 50% 592x 592x 135 3400/ 85 10,13 5,1

2120002 3GGMHF-20245-60 MERV 11 M6 ePM2,5 50% 490x 592x 135 2850/ 90 8,29 5

2120003 3GGMHF-12245-60 MERV 11 M6 ePM2,5 50% 287x 592x 135 1700/ 105 4,6 3

2120005 3GGMHF-24245-90 MERV 13 F7 ePM1 55% 592x 592x 135 3400/ 125 10,13 5,1

2120006 3GGMHF-20245-90 MERV 13 F7 ePM1 55% 490x 592x 135 2850/ 130 8,29 5

2120007 3GGMHF-12245-90 MERV 13 F7 ePM1 55% 287x 592x 135 1700/ 145 4,6 3

2120004 3GGMHF-20205-60 MERV 11 M6 ePM1 70% 490x 490x 135 2375/ 90 5 5

2120008 3GGMHF-20205-90 MERV 13 F7 ePM1 55% 480x 490x 135 2375/ 135 5 5

2120012 3GGMHF-20205-95 MERV 14 F8 ePM1 70% 490x 490x 135 2375/ 175 5 5

2120009 3GGMHF-24245-95 MERV 14 F8 ePM1 70% 592x 592x 135 3400/ 160 6.8 6.8

2120010 3GGMHF-20245-95 MERV 14 F8 ePM1 70% 490x 592x 135 2850/ 170 5.7 5.7

2120011 3GGMHF-12245-95 MERV 14 F8 ePM1 70% 287x 592x 135 1700/ 195 3.8 3.8
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6
General Ventilation Filters | Compact Filters (Box Type)

Riga-Flo
Advantages
• Range of standard sizes • High Efficiency
• Rigid design concept • Suitable for turbulent airflow

Application: Air Conditioning applications


Type: Box Filter
Frame: Galvanised steel
Media: Glass fiber
Rec. final pressure drop: 450 Pa
Max Temperature (°C): 70°C
Comment: Holding frames: Front and side access housings and
frames are available
Comment: Fire rating: UL 900

EFFICIENCY GUARANTEE

ASHRAE Airflow/pressure drop Weight


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²)
52.2-2017 (m³/h/Pa) (kg)

96026001 RF15 24x24x12 MERV 11 M6 ePM10 70% 594x 594x 292 3400/ 70 5.39 5.5

96026005 RF15 24x12x12 MERV 11 M6 ePM10 70% 289x 594x 292 1700/ 70 2.69 5

97293001 RF15 24x24x6 MERV 11 M6 ePM10 70% 594x 594x 149 2040/ 60 2.69 5.5

97293005 RF15 24x12x6 MERV 11 M6 ePM10 70% 289x 594x 149 1020/ 60 1.3 3.5

96026002 RF100 24x24x12 MERV 13 F7 ePM1 55% 594x 594x 292 3400/ 125 5.39 5.5

96026006 RF100 24x12x12 MERV 13 F7 ePM1 55% 289x 594x 292 1700/ 125 2.69 3.5

97293002 RF100 24x24x6 MERV 13 F7 ePM1 55% 594x 594x 149 2040/ 100 2.69 5.5

97293015 RF100 24x12x6 MERV 13 F7 ePM1 55% 289x 594x 149 1020/ 100 2.69 5.5

96026003 RF200 24x24x12 MERV 14 F8 ePM1 70% 594x 594x 292 3400/ 170 5.39 5.5

96026007 RF200 24x12x12 MERV 14 F8 ePM1 70% 289x 594x 292 1700/ 170 2.69 3.5

97293003 RF200 24x24x6 MERV 14 F8 ePM1 70% 594x 594x 149 2040/ 140 2.69 5.5

97293007 RF200 24x12x6 MERV 14 F8 ePM1 70% 289x 594x 149 1020/ 140 1.3 3.5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6
General Ventilation Filters | Compact Filters (Box Type)

3CPM Aeropac
Advantages
• Fine fibre ensures that filter • Robust design
maintains its efficiency • Large dust holding capacity
throughout its life in the • Suitable for variable airflow
system.

Application: Built-up banks, rooftops, split systems, free-standing


units, package systems and air handlers
Type: Compact Pleated Filter
Frame: Galvanised steel
Gasket: Neoprene
Media: Glass fiber
Rec. final pressure drop: 450 Pa
Max Temperature (°C): 70°C
Comment: UL 900
Microfine glass media formed into full pack depth pleats separated
by corrugated aluminum separators

EFFICIENCY GUARANTEE

ASHRAE Airflow/pressure drop


Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
52.2-2017 (m³/h/Pa)

2155001 3CPM-65-242412 MERV 11 M6 ePM10 70% 592x 592x 292 3400/ 110 12.3 8.6

2155002 3CPM-65-241212 MERV 11 M6 ePM10 70% 287x 592x 292 1700/ 110 5.8 6.4

2156001 3CPM-85-242412 MERV 13 F7 ePM1 55% 592x 592x 292 3400/ 145 12.3 8.6

2156002 3CPM-85-241212 MERV 13 F7 ePM1 55% 287x 592x 292 1700/ 145 5.8 6.4

2157003 3CPM-95-242412 MERV 14 F8 ePM1 70% 592x 592x 292 3400/ 160 12.3 8.6

2157002 3CPM-95-241212 MERV 14 F8 ePM1 70% 287x 592x 292 1700/ 160 5.8 6.4

2150002 3CPM-242412-60 MERV 11 M6 ePM10 70% 610x 610x 292 3400/ 75 15.7 8.6

2150001 3CPM-122412-60 MERV 11 M6 ePM10 70% 305x 610x 292 1700/ 75 7.8 6.4

2151007 3CPM-242412-90 MERV 13 F7 ePM1 55% 610x 610x 292 3400/ 110 15.7 8.6

2151008 3CPM-122412-90 MERV 13 F7 ePM1 55% 305x 610x 292 1700/ 110 7.8 6.4

2152003 3CPM-242412-95 MERV 14 F8 ePM1 70% 610x 610x 292 3400/ 135 15.7 8.6

2152004 3CPM-122412-95 MERV 14 F8 ePM1 70% 305x 610x 292 1700/ 135 7.8 6.4

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6
General Ventilation Filters | Compact Filters (Box Type)

3HCP8 Aeropac
Advantages
• Fine fibre ensures that filter • Suitable for variable airflow
maintains its efficiency • High dust holding capacity
throughout its life in the • Robust design
system

Application: Built-up filter banks, rooftops, split systems,


freestanding units, package systems and air handlers
Type: Compact Pleated Filter
Frame: Galvanised steel
Media: Glass fiber
Rec. final pressure drop: 450 Pa
Max Temperature (°C): 90°C
Comment: Media: Microfine glass media formed into full pack depth
pleats separated by corrugated aluminum
Comment: Fire Rating: UL 900

EFFICIENCY GUARANTEE

Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

2135001 3HCP8-65-242412 AEROPAC MERV 11 M6 ePM10 70% 592x 592x 292 3400/ 110 10.8 8.6

2135002 3HCP8-65-122412 AEROPAC MERV 11 M6 ePM10 70% 287x 592x 292 1700/ 110 6.4 6.4

2136001 3HCP8-85-242412 AEROPAC MERV 13 F7 ePM1 55% 592x 592x 292 3400/ 150 10.8 8.6

2136002 3HCP8-85-241212 AEROPAC MERV 13 F7 ePM1 55% 287x 592x 292 1700/ 150 5 6.4

2137001 3HCP8-95-242412 AEROPAC MERV 14 F8 ePM1 70% 592x 592x 292 3400/ 160 10.8 8.6

2137002 3HCP8-95-241212 AEROPAC MERV 14 F8 ePM1 70% 287x 592x 292 1700/ 160 5 6.4

2130002 3CPMHF-122412-60 MERV 11 M6 ePM10 70% 287x 592x 292 1700/ 95 5.6 6.4

2130003 3CPMHF-242412-60 MERV 11 M6 ePM10 70% 592x 592x 292 3400/ 95 13.1 8.6

2131001 3CPMHF-242412-90 MERV 13 F7 ePM1 55% 592x 592x 292 3400/ 130 13.1 8.6

2131002 3CPMHF-122412-90 MERV 13 F7 ePM1 55% 287x 592x 292 1700/ 130 5.6 6.4

2132001 3CPMHF-242412-95 MERV 14 F8 ePM1 70% 592x 592x 292 3400/ 155 13.1 8.6

2132002 3CPMHF-122412-95 MERV 14 F8 ePM1 70% 287x 592x 292 1700/ 155 5.6 6.4
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

65
EPA, HEPA & ULPA Filters

Products

Cleanroom Panel Cleanroom Panel Cleanroom Panel Cleanroom Panel


Megalam ProSafe Megalam Fabsafe Megalam ES Fabsafe Silent Hood
Page 67 Page 69 Page 70 Page 71

Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type)
Absolute VGXL, VGXXL ProSafe Absolute VEXL, VEXXL Absolute VGXL ProSafe Absolute CE
Page 73 Page 74 Page 75 Page 76

Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Header
Absolute CM Absolute DE Absolute DG Frame)
Page 78 Page 80 Page 81 Absolute VGHF
Page 82

As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

66
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Megalam ProSafe
Advantages
• Prosafe certified for Pharma, • Tested for food safety acc. to
Food Beverage EC 1935:2004
• 100% filter scan tested • Hygienic product acc. to VDI
according to ISO29463 6022 and ISO846
• Chemically resistant to • Free of bisphenol-A, phthalate
decontamination and cleaning and formaldehyde
agent • Manufactured and packed in a
• Microbial inert components controlled environment
acc. to ISO 846

Application: Hepa/ULPA filter for clean rooms and LAF benches


Frame: Anodized aluminium
Gasket: Silicone Gel, Seamless PU foamed gasket
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Grille, Upstream: Expanded metal painted (RAL 901)
Grille, Downstream: Expanded metal painted (RAL 901)
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: MD: 500 Pa, MX: 600 Pa, MG:800 Pa
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70 °C
Relative Humidity max: 100%
Comment: All filter tested acc. to EN 1822 with individual protocol
and packed in PE-film. Compliant with Prosafe** requirements. Other
editions on request.
Fire rating: UL 900 8SRQUHTXHVW

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

15002002 0HJDODP360'  H13 305x 610x 66 30/ 116 4,8 2,75

15002003 0HJDODP360'  H13 610x 610x 66 60/ 115 9,7 4,66

15002005 0HJDODP360'  H13 914x 610x 66 90/ 114 14,6 6,56

15002006 0HJDODP360'  H13 1219x 610x 66 1205/ 114 19,5 8,47

15210094 0HJDODP360'/6   H13 610x 610x 71 60/ 115 9.7 5.17

15002202 0HJDODP360'  H14 305x 610x 66 30/ 150 4,8 3,2

15002203 0HJDODP360'  H14 610x 610x 66 60/ 140 9,7 5,4

15002205 0HJDODP360'  H14 914x 610x 66 90/ 140 14.6 6.36
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

15002206 0HJDODP360'  H14 1219x 610x 66 1205/ 140 19.5 8.2

15002802 0HJDODP360;  H14 305x 610x 90 30/ 105 6,6 3,9

15002803 0HJDODP360;  H14 610x 610x 90 60/ 95 13,2 6,5

15002805 0HJDODP360;  H14 914x 610x 90 90/ 95 19.9 7.62

15002806 0HJDODP360;  H14 1219x 610x 90 1205/ 95 26.6 9.83

15003402 0HJDODP360*  H14 305x 610x 110 30/ 75 8,7 5,2

15003403 0HJDODP360*  H14 610x 610x 110 60/ 65 17,5 8,6

15003405 0HJDODP360*  H14 914x 610x 110 90/ 64 26.3 9.69

15003406 0HJDODP360*  H14 1219x 610x 110 1205/ 64 35.2 12.55

15002402 0HJDODP360'  U15 305x 610x 66 30/ 160 4,8 3,2

15002403 0HJDODP360'  U15 610x 610x 66 60/ 145 9.7 5,4

15002405 0HJDODP360'  U15 914x 610x 66 90/ 145 17.1 6.9

15002406 0HJDODP360'  U15 1219x 610x 66 1205/ 145 22.7 8.92

15003002 0HJDODP360;  U15 305x 610x 90 30/ 125 7,5 3,9

15003003 0HJDODP360;  U15 610x 610x 90 60/ 115 15,2 6,5

15003005 0HJDODP360;  U15 914x 610x 90 90/ 115 22.8 8.23

15003006 0HJDODP360;  U15 1219x 610x 90 1205/ 115 30.5 10.65

15003602 0HJDODP360*  U15 305x 610x 110 30/ 90 9,3 5,2

67
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

15003603 0HJDODP360*  U15 610x 610x 110 60/ 80 18,8 8,6

15003605 0HJDODP360*  U15 914x 610x 110 90/ 80 28.2 9.42

15003606 0HJDODP0*[ U15 1219x 610x 110 1205/ 80 37.8 12.19


* Pressure drop: ±  %
Other sizes are available on request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

68
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Megalam Fabsafe
Advantages
• Developed for microelectronic • 100% filter scan tested
cleanrooms and equipment according to ISO29463
• Ideal for nanoparticle filtration • Individual efficiency test
(100 nm) reports
• No organic outgassing from • High dust holding capacity
test aerosol • Manufactured and packed in a
• Ultra-low outgassing (dopant controlled environment
free) components

Application: Microelectronic cleanrooms and equipment.


Nanoparticle filtration
Frame: Anodized aluminium
Gasket: EPDM
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Grille, Upstream: Expanded metal painted
Grille, Downstream: Expanded metal painted
Rec. final pressure drop: MD: 500 Pa, MX: 600 pa, MG:800 Pa
Rec. final pressure drop: 2x Initial pressure drop
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Comment: Test: 100% individual scan test according to EN1822,
IEST RP-CC007 or required standard
Test aerosol: PSL. Oil free
Fire rating: UL900 & FM Approved
Remarks: Many frame options and dimensions are available on
request

Filter Efficiency Particle Filter Efficiency Particle Filter Efficiency Particle


Type EN1822 Dimensions WxHxD (mm) Pressure drop (Pa)
d=20nm d=100-200nm d=300nm

Fabsafe MD H13 H13 1170x 1170x 66 110 • • •

Fabsafe MD H13 H13 1170x 570x 66 110 • • •

Fabsafe MD H14 H14 1170x 1170x 66 130 • • •

Fabsafe MD H14 H14 1170x 570x 66 130 • • •

Fabsafe MX H14 H14 1170x 1170x 90 90 • • •

Fabsafe MX H14 H14 1170x 570x 90 90 • • •


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Fabsafe MG H14 H14 1170x 1170x 110 60 • • •

Fabsafe MG H14 H14 1170x 570x 110 60 • • •

Fabsafe MD U15 U15 1170x 1170x 66 140 • • •

Fabsafe MD U15 U15 1170x 570x 66 140 • • •

Fabsafe MX U15 U15 1170x 1170x 90 110 • • •

Fabsafe MX U15 U15 1170x 570x 90 110 • • •

Fabsafe MG U15 U15 1170x 1170x 110 80 • • •

Fabsafe MG U15 U15 1170x 570x 110 80 • • •

Fabsafe MX U16 U16 1170x 1170x 90 130 • • •

Fabsafe MX U16 U16 1170x 570x 90 130 • • •

Fabsafe MG U16 U16 1170x 1170x 110 90 • • •

Fabsafe MG U16 U16 1170x 570x 110 90 • • •


*Other sizes available on request

69
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Megalam ES Fabsafe
Advantages
• Developed for microelectronic • Individual efficiency test
cleanrooms and equipment reports
• No organic outgassing from • Energy saving with low
test aerosol pressure drop PTFE media
• Ultra-low outgassing (dopant • Manufactured and packed in a
free) components controlled environment
• 100% filter scan tested
according to ISO29463

Application: Microelectronic cleanrooms and equipment. Low energy


usage
Frame: Anodized aluminium
Gasket: EPDM
Media: Membrane
Separator: Hot-melt Separator Technology
Sealant: Polyurethane
Grille, Upstream: Expanded metal painted
Grille, Downstream: Expanded metal painted
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Comment: Test: 100% individual scan test according to EN1822,
IEST RP-CC007 or required standard.
Test aerosol: PSL. Oil free.
Fire rating: UL900
Remarks: Many frame options and dimensions are available on
request.

Filter Efficiency Particle Filter Efficiency Particle Filter Efficiency Particle


Type EN1822 Dimensions WxHxD (mm) Pressure drop (Pa)
d=20nm d=100-200nm d=300nm

ES Fabsafe MD H14 H14 1170x 1170x 50 75 • • •

ES Fabsafe MD H14 H14 1170x 570x 50 75 • • •

ES Fabsafe MD H14 H14 1170x 1170x 66 60 • • •

ES Fabsafe MD H14 H14 1170x 570x 66 60 • • •

ES Fabsafe MX H14 H14 1170x 1170x 90 50 • • •

ES Fabsafe MX H14 H14 1170x 570x 90 50 • • •

ES Fabsafe MD U15 U15 1170x 1170x 50 90 • • •

ES Fabsafe MD U15 U15 1170x 570x 50 90 • • •

ES Fabsafe MD U15 U15 1170x 1170x 66 75 • • •

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
ES Fabsafe MD U15 U15 1170x 570x 66 75 • • •

ES Fabsafe MX U15 U15 1170x 1170x 90 65 • • •

ES Fabsafe MX U15 U15 1170x 570x 90 65 • • •

ES Fabsafe MD U16 U16 1170x 1170x 66 105 • • •

ES Fabsafe MD U16 U16 1170x 570x 66 105 • • •

ES Fabsafe MX U16 U16 1170x 1170x 90 85 • • •

ES Fabsafe MX U16 U16 1170x 570x 90 85 • • •


*Other sizes available on request

70
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Silent Hood
Advantages
• Compact filter-diffuser for • Test port
clean room • Non-slip collar design
• Ready to install • Roomside adjustable diffuser
• Low noise disc

Application: Final filtration for clean rooms


Type: Hood Filter
Frame: Anodized aluminium
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Grille, Downstream: Expanded metal painted (RAL 9010)
MPPS efficiency:+•+•
Max Temperature (°C): 70ºC
Installation Options: Integrated suspension eyes.
Comment: Diffuser disc: Perforated aluminium
Terminal: Collar with outer dia. 305 mm (12in) or 210 mm (10in)
depending on the model
Test: 100% individually scanned in accordance with EN 1822
Fire rating: UL 900, FM 4920 approval on request
Maximum flow rate: See table, use nominal values otherwise a
reduction in efficiency may occur

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

15300001 MD13-HD10-610x610-01/02 H13 610x 610x 110 605/ 130 9.7 13

15300002 MD13-HD10-914x610-01/02 H13 914x 610x 110 905/ 130 14.6 16

15300003 MD13-HD10-1219x610-01/02 H13 1219x 610x 110 1205/ 130 19.5 19

15301001 MD13-HD12-610x610-01/02 H13 610x 610x 110 605/ 130 9.7 13

15301002 MD13-HD12-914x610-01/02 H13 914x 610x 110 905/ 130 14.6 16

15301003 MD13-HD12-1219x610-01/02 H13 1219x 610x 110 1205/ 130 19.5 19

15300101 MD14-HD10-610x610-01/02 H14 610x 610x 110 605/ 155 9.7 13

15300102 MD14-HD10-914x610-01/02 H14 914x 610x 110 905/ 155 14.6 16

15300103 MD14-HD10-1219x610-01/02 H14 1219x 610x 110 1205/ 155 19.5 19

15301101 MD14-HD12-610x610-01/02 H14 610x 610x 110 603/ 155 9.7 13

15301102 MD14-HD12-914x610-01/02 H14 914x 610x 110 905/ 155 14.6 16

15301103 MD14-HD12-1219x610-01/02 H14 1219x 610x 110 1205/ 155 19.5 19


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

15300401 MX14-HD10-610x610-01/02 H14 610x 610x 133 605/ 110 13.2 15

15300402 MX14-HD10-914x610-01/02 H14 914x 610x 133 905/ 110 19.9 19

15300403 MX14-HD10-1219x610-01/02 H14 1219x 610x 133 1205/ 110 26.6 22

15301402 MX14-HD12-914x610-01/02 H14 914x 610x 133 905/ 110 19.9 19

15301401 MX14-HD12-610x610-01/02 H14 610x 610x 133 605/ 110 13.2 15

15301403 MX14-HD12-1219x610-01/02 H14 1219x 610x 133 1205/ 110 26.6 22

15300701 MG14-HD10-610x610-01/02 H14 610x 610x 155 605/ 80 17.7 18

15300703 MG14-HD10-1219x610-01/02 H14 1219x 610x 155 1205/ 80 34.7 26

15301701 MG14-HD12-610x610-01/02 H14 610x 610x 155 605/ 80 17.1 18

15301703 MG14-HD12-1219x610-01/02 H14 1219x 610x 155 1205/ 80 34.7 26

15401001 MD13-HL10-610x610-01/02 H13 610x 610x 110 605 / 130 9,9 13

15401002 MD13-HL10-914x610-01/02 H13 914x 610x 110 905 / 125 14,9 16

15401003 MD13-HL10-1219x610-01/02 H13 1219x 610x 110 1205/ 125 19,9 19

15403001 MD13-HL12-610x610-01/02 H13 610x 610x 110 605/ 130 9,9 13

15403002 MD13-HL12-914x610-01/02 H13 914x 610x 110 905/ 125 14,9 16

15403003 MD13-HL12-1219x610-01/02 H13 1219x 610x 110 1205/ 125 19,9 19

15401101 MD14-HL10-610x610-01/02 H14 610x 610x 110 605/ 155 9,9 13

15401102 MD14-HL10-914x610-01/02 H14 914x 610x 110 905/ 155 14,9 16

15401103 MD14-HL10-1219x610-01/02 H14 1219x 610x 110 1205/ 155 19,9 19

15403101 MD14-HL12-610x610-01/02 H14 610x 610x 110 605/ 155 9,9 13

71
EPA, HEPA ULPA FILTERS | Cleanroom Panel

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

15403102 MD14-HL12-914x610-01/02 H14 914x 610x 110 905/ 155 14,9 16

15403103 MD14-HL12-1219x610-01/02 H14 1219x 610x 110 1205/ 155 19,9 19

15401401 MX14-HL10-610x610-01/02 H14 610x 610x 133 605/ 110 13,4 13

15401402 MX14-HL10-914x610-01/02 H14 914x 610x 133 905/ 110 20,2 16

15401403 MX14-HL10-1219x610-01/02 H14 1219x 610x 133 1205/ 110 24 19

15403401 MX14-HL12-610x610-01/02 H14 610x 610x 133 605/ 110 13,4 13

15403402 MX14-HL12-914x610-01/02 H14 914x 610x 133 905/ 110 20,2 16

15403403 MX14-HL12-1219x610-01/02 H14 1219x 610x 133 1205/ 110 27 19

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

72
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute VGXL, VGXXL ProSafe


Advantages
• 23% energy savings compared • Tested resistance against
to market average disinfectant and cleaning
• Lowest weight in industry procedures
• Strong and airtight frame • Compact, lightweight and fully
• Hygienic product acc. to VDI incinerable for optimised waste
6022 and ISO846 management
• Approved to EC1935/2004 for • Optimised for bag-in bag-out
food contact safe changes
• Free of BPA, formaldehyde and • Machine-tested leak-free
phthalates construction

Application: High airflow filter for make-up air and exhaust air
applications
Type: V-Bank Box Filter
Frame: ABS
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:( • ( • ( • 
+ • + • 
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 600 Pa
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70° C
Relative Humidity max: 100%
Installation Options: CamSafe
Comment: Compliant with Prosafe** requirements
)LUHUDWLQJ8/

Pressure drop Weight


Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow (m³/h) Area (m²)
(m³/h/Pa)*** (kg)

ABV3022131001 VGXL10-610x305x292-P-PS E10 610x 305x 292 1500/1800 150/190 10,9 4,9

ABV6022121001 VGXL10-610x610x292-P-PS E10 610x 610x 292 3400/4000 150/190 22,0 7,7

ABV3031131001 VGXXL10-610x305x292-P-PS E10 610x 305x 292 2300 210 14,9 5,3

ABV6031121001 VGXXL10-610x610x292-P-PS E10 610x 610x 292 5000 210 30,2 8,5

ABV3122131001 VGXL11-610x305x292-P-PS E11 610x 305x 292 1500/1800 170/210 18,9 5.7

ABV6122121001 VGXL11-610x610x292-P-PS E11 610x 610x 292 3400/4000 170/210 38.9 9.3

ABV3222131001 VGXL12-610x305x292-P-PS E12 610x 305x 292 1500/1800 180/ 220 18,9 5,7
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

ABV6222121001 VGXL12-610x610x292-P-PS E12 610x 610x 292 3400/4000 180/220 38,3 9,3

ABV3322131001 VGXL13-610x305x292-P-PS H13 610x 305x 292 1500/1800 200/240 20,5 5,8

ABV6322121001 VGXL13-610x610x292-P-PS H13 610x 610x 292 3400/4000 200/240 41,6 9,6

ABV3332131001 VGXXL13-610x305x292-P-PS H13 610x 305x 292 2300 400 20,5 5,8

ABV6332121001 VGXXL13-610x610x292-P-PS H13 610x 610x 292 5000 400 41,6 9,6

ABV3422131001 VGXL14-610x305x292-P-PS H14 610x 305x 292 1500 250 20,5 5,8

ABV6422121001 VGXL14-610x610x292-P-PS H14 610x 610x 292 3400 250 41,6 9,6

ABV3432131001 VGXXL14-610x305x292-P-PS H14 610x 305x 292 1800 310 20,5 5,8

ABV6432121001 VGXXL14-610x610x292-P-PS H14 610x 610x 292  310 41,6 9,6
* Not available with pressure test “DIN“ gasket
** All certificates and further information are available on www.camfil.com/prosafe
*** Pressure drop: ± 10 %


EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute VEXL, VEXXL


Advantages
• For very high airflows (up to • 100% leak-free : individually
3,7 m/s) scan tested
• 23% Energy savings compared • Strong and airtight frame
to market average • Optimized for Bag-in Bag-out
• Lightest V-bank steel HEPA in safe change
the industry • Most convenient handling

Application: High airflow filter for make-up air and exhaust air
applications
Frame: Galvanised steel
Gasket: Seamless PU foamed gasket
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:( • ( • ( • +
• + • 
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 600 Pa
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: CamBox, CamSafe, CamCube
Comment: Special versions on request (e.g. stainless steel
frame or high temperature version 120ºC))LUHUDWLQJ8/

Pressure drop
Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow (m³/h) Area (m²) Weight (kg)
(m³/h/Pa)*

ABV3021131000 VEXL10-610x305x292-P E10 610x 305x 292 1500/1800 150/190 10.9 6,0

ABV6021121000 VEXL10-610x610x292-P E10 610x 610x 292 3400/4000 150/190 22 9,0

ABV3031131000 VEXXL10-610x305x292-P E10 610x 305x 292 2300 210 14.9 6,4

ABV6031121000 VEXXL10-610x610x292-P E10 610x 610x 292 5000 210 30.2 9,9

ABV3121131000 VEXL11-610x305x292-P E11 610x 305x 292 1500/1800 170/210 18,9 6.8

ABV6121121000 VEXL11-610x610x292-P E11 610x 610x 292 3400/4000 170/210 38.3 10.7

ABV3221131000 VEXL12-610x305x292-P E12 610x 305x 292 1500/1800 180/220 18.9 6,8

ABV6221121000 VEXL12-610x610x292-P E12 610x 610x 292 3400/4000 180/220 38.3 10,7

ABV3321131000 VEXL13-610x305x292-P H13 610x 305x 292 1500/1800 200/240 20.5 6,9

ABV6321121000 VEXL13-610x610x292-P H13 610x 610x 292 3400/4000 200/240 41.6 11,0

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
ABV3331131000 VEXXL13-610x305x292-P H13 610x 305x 292 2300 400 20.5 6,9

ABV6331121000 VEXXL13-610x610x292-P H13 610x 610x 292 5000 400 41.6 11,0

ABV3421131000 VEXL14-610x305x292-P H14 610x 305x 292 1500 250 20.5 6,9

ABV6421121000 VEXL14-610x610x292-P H14 610x 610x 292 3400 250 41.6 11,0

ABV3431131000 VEXXL14-610x305x292-P H14 610x 305x 292 1800 310 20.5 6,9

ABV6431121000 VEXXL14-610x610x292-P H14 610x 610x 292 4000 310 41.6 11,0
* Pressure drop ± 10%
UL900 per Underwriters Laboratories


EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute VGXL ProSafe


Advantages
• 23% energy savings compared • - Tested resistance against
to market average disinfectant and cleaning
• Lowest weight in the industry agents
• Strong and airtight frame • Compact, lightweight and fully
• Prosafe certified: incinerable for optimised waste
• - Hygienic product acc. to VDI management
6022 and ISO846 • Optimised for bag-in bag-out
• - Tested for food safety acc. to safe changes
EC 1935:2004 • 100% leak-free : individually
• - Free of BPA, formaldehyde scantested
and phthalates

Application: High airflow filter for make-up air and exhaust air
applications
Type: V-Bank Box Filter
Frame: ABS
Gasket: Seamless PU foamed gasket
Media: Glass fiber
Separator: Hot-melt
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 600 Pa
Max airflow: 1,1 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Installation Options: CamSafe, AHU
Comment: Compliant with Prosafe** requirements
)LUHUDWLQJ8/

Pressure drop
Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow (m³/h) Area (m²) Weight (kg)
(m³/h/Pa)**

ABV2022131001 VGXL10-595x289x292-P-PS E10 595x 289x 292 1500/1800 170/210 10,3 4,6

ABV5022121001 VGXL10-595x595x292-P-PS E10 595x 595x 292 3400/4000 170/210 21,5 7,4

ABV2122131001 VGXL11-595x289x292-P-PS E11 595x 289x 292 1500/1800 190/230 17.5 5,3

ABV5122121001 VGXL11-595x595x292-P-PS E11 595x 595x 292 3400/4000 190/230 37.3 8,8

ABV2222131001 VGXL12-595x289x292-P-PS E12 595x 289x 292 1500/1800 200/240 17,9 5,3

ABV5222121001 VGXL12-595x595x292-P-PS E12 595x 595x 292 3400/4000 200/240 37,3 9,0

ABV2322131001 VGXL13-595x289x292-P-PS H13 595x 289x 292 1500 220 19,4 5,5

ABV5322121001 VGXL13-595x595x292-P-PS H13 595x 595x 292 3400 220 40,5 9,3

ABV2422131001 VGXL14-595x289x292-P-PS H14 595x 289x 292 1500 270 19,4 5,5
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

ABV5422121001 VGXL14-595x595x292-P-PS H14 595x 595x 292 3400 270 40,5 9,3
* All certificates and further information are available on www.camfil.com/prosafe
** Pressure drop: ± 10 %


EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute CE
Advantages
• Low to medium airflow (up to • 100% leakfree, individually
1,8 m/s) scan tested
• Galvanised metal frame for
stability

Application: Very high efficiency final filtration in air conditioning


systems housings-ducts or diffusers
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
MPPS efficiency:(•+•
Max. final pressure drop: 500 Pa
Max Temperature (°C): 70°C
Installation Options: Mounting systems: Ducts, Diffusers, CAMSAFE
Comment: Fire rating: DIN 53438 Class Fl

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1400508 CED11-305x305x150-P0 E11 305x 305x 150 290/ 125 2,2 4

1400506 CED11-457x457x150-P0 E11 457x 457x 150 660/ 125 4,9 10

1400505 CED11-575x575x150-P0 E11 575x 575x 150 1055/ 125 7,8 11

1400507 CED11-305x610x150-P0 E11 305x 610x 150 590/ 125 4,4 6

1400504 CED11-610x610x150-P0 E11 610x 610x 150 1190/ 125 8,9 12

1400503 CED11-762x610x150-P0 E11 762x 610x 150 1490/ 125 11,1 13,5

1400502 CED11-914x610x150-P0 E11 914x 610x 150 1790/ 125 13,3 15

1400501 CED11-1219x610x150-P0 E11 1219x 610x 150 2380/ 125 17,7 18

1400558 CEX11-305x305x150-P0 E11 305x 305x 150 380/ 125 3 4

1400556 CEX11-457x457x150-P0 E11 457x 457x 150 865/ 125 6,9 10

1400555 CEX11-575x575x150-P0 E11 575x 575x 150 1385/ 125 11 11

1400557 CEX11-305x610x150-P0 E11 305x 610x 150 770/ 125 6,1 6

1400554 CEX11-610x610x150-P0 E11 610x 610x 150 1560/ 125 12,4 12

1400553 CEX11-762x610x150-P0 E11 762x 610x 150 1950/ 125 15,5 13,5

1400552 CEX11-914x610x150-P0 E11 914x 610x 150 2335/ 125 18,6 15

1400551 CEX11-1219x610x150-P0 E11 1219x 610x 150 3120/ 125 24,8 18

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
1400654 CEG11-305x610x292-P0 E11 305x 610x 292 950/ 125 7,2 7,2

1400653 CEG11-457x610x292-P0 E11 457x 610x 292 1420/ 125 10,8 9,9

1400652 CEG11-610x610x292-P0 E11 610x 610x 292 1900/ 125 14,4 12,5

1400651 CEG11-762x610x292-P0 E11 762x 610x 292 2380/ 125 18 16

1400704 CET11-305x610x292-P0 E11 305x 610x 292 1190/ 125 10,9 7,2

1400703 CET11-457x610x292-P0 E11 457x 610x 292 1780/ 125 16,4 10

1400702 CET11-610x610x292-P0 E11 610x 610x 292 2380/ 125 21,8 13

1400701 CET11-762x610x292-P0 E11 762x 610x 292 2975/ 125 27 16,2

1400008 CED13-305x305x150-P0 H13 305x 305x 150 317/ 250 2,4 4

1400006 CED13-457x457x150-P0-S H13 457x 457x 150 726/ 250 5,5 10

1400005 CED13-575x575x150-P0-S H13 575x 575x 150 1161/ 250 8,7 11

1400007 CED13-305x610x150-P0-S H13 305x 610x 150 645/ 250 4,9 6

1400004 CED13-610x610x150-P0-S H13 610x 610x 150 1305/ 250 9,8 12

1400003 CED13-762x610x150-P0-S H13 762x 610x 150 1635/ 250 12,3 13,5

1400002 CED13-914x610x150-P0-S H13 914x 610x 150 1958/ 250 14,7 15

1400001 CED13-1219x610x150-P0-S H13 1219x 610x 150 2618/ 250 19,7 18

1400058 CEX13-305x305x150-P0 H13 305x 305x 150 380/ 250 3,2 4

1400056 CEX13-457x457x150-P0-S H13 457x 457x 150 867/ 250 7,4 10

1400055 CEX13-575x575x150-P0-S H13 575x 575x 150 1384/ 250 12 11

1400057 CEX13-305x610x150-P0-S H13 305x 610x 150 773/ 250 6,6 6

1400054 CEX13-610x610x150-P0-S H13 610x 610x 150 1565/ 250 13,4 12

76
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1400053 CEX13-762x610x150-P0-S H13 762x 610x 150 1957/ 250 16,7 13,5

1400052 CEX13-914x610x150-P0-S H13 914x 610x 150 2348/ 250 20,1 15

1400051 CEX13-1219x610x150-P0-S H13 1219x 610x 150 3131/ 250 27,1 18

1400154 CEG13-305x610x292-P0-S H13 305x 610x 292 893/ 250 7,8 7

1400153 CEG13-457x610x292-P0-S H13 457x 610x 292 1340/ 250 11,7 9,9

1400152 CEG13-610x610x292-P0-S H13 610x 610x 292 1804/ 250 15,7 12,5

1400151 CEG13-762x610x292-P0-S H13 762x 610x 292 2251/ 250 19,6 16

1400204 CET13-305x610x292-P0-S H13 305x 610x 292 1230/ 250 11,7 7

1400203 CET13-457x610x292-P0-S H13 457x 610x 292 1850/ 250 17,5 9,9

1400202 CET13-610x610x292-P0-S H13 610x 610x 292 2485/ 250 23,5 12,5

1400201 CET13-762x610x292-P0-S H13 762x 610x 292 3100/ 250 29,4 16


*Other sizes are available on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

77
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute CM
Advantages
• Low to medium airflow (up to • 100% leakfree, individually
1,8 m/s) scan tested
• Completely incinerable, no
metal used

Application: HEPA filter for standard applications


Frame: MDF
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:(•+ • 
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 800 Pa
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Comment: All filter tested acc. to EN 1822 with individual protocol
Other options available: Galvanized frame on request

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1400758 CMD11-305x305x150-PO E11 305x 305x 150 236/ 125 1.8 4

1400756 CMD11-457x457x150-PO E11 457x 457x 150 580/ 125 4.3 10

1400755 CMD11-575x575x150-PO E11 575x 575x 150 950/ 125 7.1 11

1400757 CMD11-305x610x150-PO E11 305x 610x 150 505/ 125 3.8 6

1400754 CDM11-610x610x150-PO E11 610x 610x 150 1080/ 125 8 12

1400753 CMD11-762x610x150-PO E11 762x 610x 150 1370/ 125 10.1 13.5

1400752 CMD11-914x610x150-PO E11 914x 610x 150 1650/ 125 12.3 15

1400751 CMD11-1219x610x150-PO E11 1219x 610x 150 2220/ 125 16.5 18

1400808 CMX11-305x305x150-PO E11 305x 305x 150 310/ 125 2.5 4

1400806 CMX11-457x457x150-PO E11 457x 457x 150 760/ 125 6 10

1400805 CMX11-575x575x150-PO E11 575x 575x 150 1245/ 125 9.9 11

1400807 CMX11-305x610x150-PO E11 305x 610x 150 668/ 125 5.3 6

1400804 CMX11-610x610x150-PO E11 610x 610x 150 1410/ 125 11.2 12

1400803 CMX11-762x610x150-PO E11 762x 610x 150 1788/ 125 14.2 12

1400802 CMX11-914x610x150-PO E11 914x 610x 150 2150/ 125 17.1 15

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
1400801 CMX11-1219x610x150-PO E11 1219x 610x 150 2900/ 125 23 18

1400904 CMG11-305x610x292-PO E11 305x 610x 292 815/ 125 6.2 7.2

1400903 CMG11-457x610x292-PO E11 457x 610x 292 1265/ 125 9.6 9.6

1400902 CMG11-610x610x292-PO E11 610x 610x 292 1735/ 125 13.1 13

1400901 CMG11-762x610x292-PO E11 762x 610x 292 2180/ 125 16.6 16.5

1400954 CMT11-305x610x292-PO E11 305x 610x 292 1015/ 125 9.2 7.2

1400953 CMT11-457x610x292-PO E11 457x 610x 292 1585/ 125 14.4 10

1400952 CMT11-610x610x292-PO E11 610x 610x 292 2170/ 125 19,8 13,0

1400951 CMT11-762x610x292-PO E11 762x 610x 292 2725/ 125 25 16.2

1400258 CDM13-305x305x150-PO H13 305x 305x 150 258/ 250 1.9 4

1400256 CDM13-457x457x150-PO-S H13 457x 457x 150 636/ 250 4.8 10

1400255 CDM13-575x575x150-PO-S H13 575x 575x 150 1046/ 250 7.9 11

1400257 CMD13-305X610X150-PO-S H13 305x 610x 150 553/ 250 4.2 6

1400254 CMD13-610X610X150-PO-S H13 610x 610x 150 1183/ 250 8.9 12

1400253 CMD13-762x610x150-PO-S H13 762x 610x 150 1497/ 250 11.3 13.5

1400252 CMD13-914x610x150-PO-S H13 914x 610x 150 1805/ 250 13.6 15

1400251 CMD13-1219x610x150-PO-S H13 1219x 610x 150 2434/ 250 18.3 18

1400308 CMX13-305x305x150-PO H13 305x 305x 150 310/ 250 2.7 4

1400306 CMX13-457x457x150-PO-S H13 457x 457x 150 760/ 250 6.5 8

1400305 CMX13-575x575x150-PO-S H13 575x 575x 150 1247/ 250 10.7 10

1400307 CMX13-305x610x150-PO-S H13 305x 610x 150 664/ 250 5.7 6

78
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1400304 CMX13-610x610x150-PO-S H13 610x 610x 150 1419/ 250 12.1 12

1400303 CMX13-762x610x150-PO-S H13 762x 610x 150 1793/ 250 15.3 13.5

1400302 CMX13-914x610x150-PO-S H13 914x 610x 150 2166/ 250 18.5 15

1400301 CMX13-1219x610x150-PO-S H13 1219x 610x 150 2912/ 250 24.9 18

1400404 CMG13-305x610x292-PO-S H13 305x 610x 292 770/ 250 6.7 7

1400403 CMG13-457x610x292-PO-S H13 457x 610x 292 1210/ 250 10.5 9.9

1400402 CMG13-610x610x292-PO-S H13 610x 610x 292 1635/ 250 14.2 12.5

1400401 CMG13-762x610x292-PO-S H13 762x 610x 292 2075/ 250 18.1 16

1400454 CMT13-305x610x292-PO-S H13 305x 610x 292 1060/ 250 10.1 7.2

1400453 CMT13-457X610X292-PO-S H13 457x 610x 292 1670/ 250 15.8 10

1400452 CMT13-610X610X292-PO-S H13 610x 610x 292 2250/ 250 21.3 13

1400451 CMT13-762X610X292-PO-S H13 762x 610x 292 2855/ 250 27.1 16.2
Pressure drop: ±10%
Type -P = PU gasket
Other sizes are available on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

79
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute DE
Advantages
• High airflow (2,5 m/s) • Galvanized filter frame
• Scanable flat media pack • 100% leakfree, individually
surface scan tested

Application: HEPA-filter for high air flows


Frame: Galvanised steel
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Rec. final pressure drop: 1000 Pa
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Comment: Fire rating: DIN 53438 Class Fl

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1408031 DE13-305x610x292-P0-S H13 305x 610x 292 1500/ 250 19,5 13

1408032 DE13-610x610x292-P0-S H13 610x 610x 292 3400/ 250 39,6 16

1408033 DE13-762x610x292-P0-S H13 762x 610x 292 3750/ 250 50,1 20

1408034 DE14-305x610x292-P0-S H14 305x 610x 292 1500/ 290 19,5 13

1408035 DE14-610x610x292-P0-S H14 610x 610x 292 3400/ 290 39,6 16

1408036 DE14-762x610x292-P0-S H14 762x 610x 292 3750/ 290 50,1 20


*Other sizes are available on reques
)UDPHLVDYDLODEOHLQ(OHFWUR]LQF

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

80
EPA, HEPA ULPA FILTERS | Compact Filters (Box Type)

Absolute DG
Advantages
• High airflow (2,5 m/s) • 100% leakfree, individually
• Scanable flat media pack scan tested
surface • Compliant to VDI 6022
• Lightweight and fully
incinerable

Application: HEPA-Filter for high air flows


Frame: ABS
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:+ • + • DFFWR(1
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 1000 Pa
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Comment: All filter tested acc. to EN 1822 with individual protocol.
Fire rating: DIN 53438 Class F1

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1408037 DG13-305x610x292-PO-OW-V H13 305x 610x 292 1500/ 250 19.8 8.5

1408038 DG13-610x610x292-PO-OW-V H13 610x 610x 292 3000/ 250 39,6 12,0

1408039 DG13-762x610x292-PO-OW-V H13 762x 610x 292 3750/ 250 50,1 15,5

1408040 DG14-305x610x292-PO-OW-V H14 305x 610x 292 1300/ 250 19.8 8.5

1408041 DG14-610x610x292-PO-OW-V H14 610x 610x 292 2600/ 250 39.9 12

1408042 DG14-762x610x292-PO-OW-V H14 762x 610x 292 3300/ 250 50.1 15.5
Other dimensions on demand
Pressure drop: +- 15%
Type P = gasket on in let air side
Type W-V = filter with handle and grid
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

81
EPA, HEPA ULPA FILTERS | Compact Filters (Header Frame)

Absolute VGHF
Advantages
• High airflow (up to 2,3m/s) • Completely incinerable
• Compact HEPA filter with • Easy Hepa upgrade of AHU
header frame

Application: EPA/HEPA final filtration in air conditioning systems


and industrial processes
Frame: ABS; header frame, 25mm
Gasket: Polyurethane, endless foamed, Flat gasket
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:( • + • 
Rec. final pressure drop: 2x Initial pressure drop
Max. final pressure drop: 500 Pa
Max airflow: Nominal flow rate (if not, efficiency drops)
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available. Type 8 and FC housings.
Comment: All filter auto-tested acc. EN 1822 and individually packed
in PE-foil. Other editions on request

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

2430003 VGHF10-592X287X300 E10 592x 287x 300 1700/ 250 8.4 3

2430002 VGHF10-592X490X300 E10 592x 490x 300 2850/ 250 15.2 4

2430001 VGHF10-592X592X300 E10 592x 592x 300 4000/ 250 18.5 5

2440002 VGHF13-592x287x300-OP-S H13 592x 287x 300 1350/ 250 13.1 3

2440003 VGHF13-592x490x300-OP-S H13 592x 490x 300 2450/ 250 24.2 4

2440001 VGHF13-592x592x300-OP-S H13 592x 592x 300 3000/ 250 29.6 5


Pressure drop: ± 10%
Gasket available on request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

82
High Temperature Filters

Products

Compact Filters (120°C) Compact Filters (250°C) Compact Filters (250°C) Compact Filters (350°C)
Sofilair HT 120-H13 Airopac HT-HF Absolute 1FRSI Absolute 1FRK-V
Page 84 Page 85 Page 86 Page 87

Compact Filters (350°C) Compact Filters (350°C)


Termikfil 2000 Absolute D-Pyro
Page 88 Page 89
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

83
High Temperature Filters | Compact Filters (120°C)

Sofilair HT 120-H13
Advantages
• High Temperature HEPA Filter • Strong and airtight frame
• For very high airflows (up to • Maximum continuous operating
3,7 m/s) temperature 120ºC
• Lightest V-bank steel HEPA in • High filter surface area offers
the industry low pressure drop for energy
• 100% leak-free : individually savings and longer life
scan tested

Application: Industry and hospitals


Frame: Galvanised steel
Gasket: EPDM
Media: Glass fiber
Separator: Glass fiber
Sealant: Polyurethane
Max Temperature (°C): 120°C
Installation Options: Mounting systems: FCBL-A housing
Comment: Temperature: 120°C maximum continuous

Art. No. Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1564.01.00 SFR120-E-2500-H13 H13 610x 610x 292 2500/ 250 24 19

1568.01.50 SFR120-E-1300-H13 H13 289x 595x 292 1300/ 250 16 12

1567.01.50 SFR120-E-3200-H13 H13 595x 595x 292 3200/ 250 38 22

1566.01.00 SFR120-E-1500-H13 H13 305x 610x 292 1500/ 250 16 13

1561.01.00 SFR120-E-3400-H13 H13 610x 610x 292 3400/ 250 33 20

1561.02.00 SFR120-E-4000-H13 H13 610x 610x 292 4000/ 250 40 23

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

84
High Temperature Filters | Compact Filters (250°C)

Airopac HT-HF
Advantages
• High temperature compact fine • Long filter life time
filter • Maximum continuous operating
• Free of paint effecting temperature 250ºC
substances

Application: Paint bake ovens and other high temperature


applications
Frame: Galvanised steel
Gasket: Glass fibre cord
Media: Glass fiber
Separator: Aluminium
Sealant: Glass fiber
Dimensions: Filter front dimensions according EN 15805
Max Temperature (°C): 260 °C
Temperature max. (peak): 400 °C
Relative Humidity max: 100%
Comment: Temperature: 260 °C continuously with peaks up to 400°C
EFFICIENCY GUARANTEE

High efficiency, high temperature, silicon free compact filter.

Art. No. Type EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

2181001 3CPM-HT-122412-90 F8 ePM1 70% 305x 610x 292 1700/ 120 7.7 5.6

2181002 3CPM-HT-242412-90 F8 ePM1 70% 610x 610x 292 3400/ 110 15.9 9.5

2181004 3CPM-HT-242406-90 F8 ePM1 70% 610x 610x 150 1700/ 65 7.8 5.6

2181005 3CPM-HT-122403-90 F8 ePM1 70% 305x 610x 78 750/ 80 2.4 2

2181006 3CPM-HT-242403-90 F8 ePM1 70% 610x 610x 78 1500/ 80 4.9 4

2181007 3CPM-HT-305*610*52-90 F8 ePM1 70% 305x 610x 52 750/ 90 2.7 1.8

2181008 3CPM-HT-610*610*52-90 F8 ePM1 70% 610x 610x 52 1500/ 90 5.4 3.6

2181009 3CPM-HT-480*480*78-90 F8 ePM1 70% 480x 480x 78 800/ 80 2.3 2.1

2181010 3CPM-HT-915*457*78-90 F8 ePM1 70% 915x 457x 78 2000/ 100 5.7 4.5

2181011 3CPM-HT-762 *457*78-90 F8 ePM1 70% 762x 457x 78 1250/ 80 3.6 3.8

2191001 3CPM-HT-HF-242412-90 F8 ePM1 70% 592x 592x 292 3000/ 150 13.3 8.3

2190001 3CPM-HT-HF-242412-60 M6 ePM10 70% 592x 592x 292 3000/ 105 12,6 8,3
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

2180001 3CPM-HT-122412-60 M6 ePM10 70% 305x610x292 1700/80 7,7 5,6

2180002 3CPM-HT-242412-60 M6 ePM10 70% 610x610x292 3400/75 15,9 9,5

2180004 3CPM-HT-242406-60 M6 ePM10 70% 610x 610x 150 1700/ 30 7,8 5,6

2180006 3CPM-HT-242403-60 M6 ePM10 70% 610x 610x 78 1500/ 30 4,3 4

2180005 3CPM-HT-122403-60 M6 ePM10 70% 305x 610x 78 750/ 30 2,1 2


Outer dimensions of the filter due to the Screw Heads + 7 mm in width

85
High Temperature Filters | Compact Filters (250°C)

Absolute 1FRSI
Advantages
• High temperature HEPA Filter • 100% leak-free: individually
• High air flow (1,5m/s) scan tested at 20ºC
• Maximum continuous operating • High mechanical stability
temperature 250ºC

Application: Protection for clean processes at high temperatures


Frame: Stainless steel
Gasket: Silicone
Media: Glass fiber
Separator: Aluminium
Sealant: Silicon HT
MPPS efficiency:+ • 
Max. final pressure drop: 500 Pa
Max Temperature (°C): 250ºC
Relative Humidity max: 100%
Comment: Please note the installation and assembly instructions!

Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1FRSI-25-1SIHT H13 203x 203x 78 50/ 250 0,5 2,5

1FRSI-50-1SIHT H13 203x 203x 150 90/ 250 0,9 3,1

1FRSI-110-1SIHT H13 305x 305x 150 250/ 250 2,4 4,0

1FRSI- 200-1SIHT H13 305x 305x 292 410/ 250 5,1 5,1

1FRSI- 220-1SIHT H13 305x 610x 150 540/ 250 5,0 7,9

1FRSI- 300-1SIHT H13 457x 457x 150 620/ 250 5,9 8,5

1FRSI- 450-1SIHT H13 305x 610x 292 900/ 250 10,4 15,6

1FRSI- 600-1SIHT H13 610x 610x 150 1180/ 250 10,9 11,4

1FRSI- 725-1SIHT H13 457x 610x 292 1420/ 250 16,3 18,0

1FRSI- 830-1SIHT H13 762x 610x 150 1500/ 250 13,7 13,5

1FRSI- 980-1SIHT H13 915x 610x 150 1800/ 250 16,8 15,8

1FRSI-1000-1SIHT H13 610x 610x 292 1960/ 250 22,5 16,5

1FRSI-1250-1SIHT H13 762x 610x 292 2500/ 250 28,4 23,5

1FRSI-610x457x150-1SIHT H13 610x 457x 150 860/ 250 7,8 8,4

1FRSI-457x457x292-1SIHT H13 457x 457x 292 1030/ 250 12,8 10,5

1FRSI-610x762x292-1SIHT H13 610x 762x 292 2500/ 250 22,7 21,5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Other dimensions & gasket on request
Type -1SIHT = gasket upstream (standard)

86
High Temperature Filters | Compact Filters (350°C)

Absolute 1FRK-V
Advantages
• High temperature HEPA Filter • Individually scan tested at
• Filter class H13 acc. to EN 20ºC
1822 (at 20ºC) • High mechanical stability
• High air velocity (1,5m/s) • Reinforced stainless steel
• Maximum continuous operating frame
temperature 350ºC

Application: Protection for clean processes at high temperature


Frame: Reinforced stainless steel
Gasket: Glass Fiber
Media: Glass fiber
Separator: Aluminium
Sealant: Ceramic
MPPS efficiency:��������������
Max. final pressure drop: 500 Pa
Max Temperature (°C): 350ºC
Relative Humidity max: 100%
Comment: Please note installation and assembly instructions! Due
to the different thermal expansion coefficients of the individual
filter components the ceramic potting may form cracks during
the tempering process. At operating temperature (350 ºC) these
filters have an overall efficiency of 99,97% at 0,3 μm, leackages are
possible.

Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

1FRKV- 220-1W H13 305x 610x 150 540/ 250 5,1 10,3

1FRKV- 300-1W H13 457x 457x 150 620/ 250 5,9 11,2

1FRKV- 600-1W H13 610x 610x 150 1180/ 250 11,4 13,5

1FRKV- 980-1W H13 915x 610x 150 1780/ 250 16,8 18,3

1FRKV- 450-1W H13 305x 610x 292 900/ 250 10,4 18

1FRKV- 725-1W H13 457x 610x 292 1420/ 250 16,3 21,4

1FRKV-1000-1W H13 610x 610x 292 1960/ 250 22,5 23,4

1FRKV-1250-1W H13 762x 610x 292 2480/ 250 28,4 25,9


Modell -1W = Gasket upstream (standard)
Modell -01W = Gasket downstream
Modell -2W = Gasket both sides
Modell -0 = no gasket
Other editions on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

87
High Temperature Filters | Compact Filters (350°C)

Termikfil 2000
Advantages
• High temperature HEPA filter • Maximum continuous operating
• For low installation depths temperature 350ºC
(84mm) and low air velocity • Exclusive precuring process at
(0,9m/s) 300ºC carried out in the plant
• Efficiency 99,99% at 0,3 μm • Efficiency tested after
(meets FDA requirements) precuring

Application: Protection of ultra-clean processes at high temperature,


sterilisation tunnels in the pharmaceutical industry
Frame: Composite ceramic
Gasket: Glass Fiber, Braided glass fiber
Media: Glass fiber
Separator: Glass fiber
Sealant: Ceramic
Grille, Upstream: Stainless steel
Grille, Downstream: Stainless steel
Max. final pressure drop: 350 Pa
Temperature max. (peak): 350ºC
Installation Options: A stainless steel adaptor frame can be supplied
to reach the thickness of 150mm or 292mm
Comment: Efficiency 0.3μm : > 99.99% @ front velocity 0.9m/s
Local penetration max.: 10-4 maximum,(0.01% acc. FDA) after the
1st heating cycle on site following Camfil procedure
Note : since full running condition in customer equipment are not
able to be fully described, Camfil is not able to guarantee further to
the 1st heating cycle on site
NB: To reduce fume emission when starting up, TERMIKFIL
undergoes a specific precuring cycle in the factory at 300ºC using an
exclusive CAMFIL process

Art. No. Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

3415.06.00 3P3 305x 305x 84 300/ 250 2,9 1.8

3415.01.00 3P6 305x 610x 84 600/ 250 5,9 3.3

3415.07.00 4P4 457x 457x 84 675/ 250 5 2.8

3415.05.00 4P6 457x 610x 84 900/ 250 8,9 3.7

3415.02.00 6P6 610x 610x 84 1200/ 250 12,1 4.6

3415.03.00 7P6 762x 610x 84 1500/ 250 15,3 6

3415.04.00 9P6 915x 610x 84 1800/ 250 18,5 8

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

88
High Temperature Filters | Compact Filters (350°C)

Absolute D-Pyro
Advantages
• High temperature HEPA filter • Leak-free and proven efficiency
• Filterclass H14 during all after 200 cycles
conditions (H13 also available) • Very robust construction
• Maximum continuous operating • ProSafe + REACH compliance
temperature 350ºC • Patented construction
• No tempering and system
cleaning required

Application: HEPA filter protection for clean processes at high


temperature, especially for Life Science (depyrogenation tunnels,
ovens)
Frame: Stainless steel
Media: Glass fiber
Separator: Stainless steel
Sealant: Inorganic polymer
MPPS efficiency:•DW—P•DW0336+DQG
•DW—P•DW0336+HYHQDIWHUKHDWLQJ
F\FOHOHDNIUHH•F\FOHV
Max. final pressure drop: 700 Pa
Comment: Temperature: 350 °C with peaks up to 400 °C.
ISO 5 under all production steps. Please note installation and
assembly instructions! Other editions on request (with gasket, or
sizes)

Type EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

DHT14-305x610x150-0-SP H14 305x 610x 150 540/ 310 4,8 8,0

DHT14-457x457x150-0-SP H14 457x 457x 150 620/ 300 5,3 9,0

DHT14-762x457x150-0-SP H14 762x 457x 150 1080/ 290 11.8 15

DHT14-457x610x150-0-SP H14 457x 610x 150 850/ 300 7,3 12,0

DHT14-610x610x150-0-SP H14 610x 610x 150 1180/ 290 10,4 16,0

DHT14-762x610x150-0-SP H14 762x 610x 150 1500/ 290 13,1 34,0

DHT14-305x610x292-0-SP H14 305x 610x 292 900/ 310 9,7 13,0

DHT14-457x610x292-0-SP H14 457x 610x 292 1420/ 290 14,6 19,5

DHT14-610x610x292-0-SP H14 610x 610x 292 1960/ 290 20,7 26,0

DHT14-762x610x292-0-SP H14 762x 610x 292 2480/ 290 25,9 44,0

DHT13-305x610x150-0-SP H13 305x 610x 150 460/ 250 4,8 8,0


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

DHT13-457x457x150-0-SP H13 457x 457x 150 510/ 250 5,3 9,0

DHT13-457x610x150-0-SP H13 457x 610x 150 750/ 250 7,3 12,0

DHT13-610x610x150-0-SP H13 610x 610x 150 990/ 250 10,4 16,0

DHT13-762x610x150-0-SP H13 762x 610x 150 1260/ 250 13,1 34,0

DHT13-305x610x292-0-SP H13 305x 610x 292 780/ 250 9,7 13,0

DHT13-457x610x292-0-SP H13 457x 610x 292 1310/ 250 14,6 19,5

DHT13-610x610x292-0-SP H13 610x 610x 292 1850/ 250 20,7 26,0

DHT13-762x610x292-0-SP H13 762x 610x 292 2250/ 250 25,9 44,0


Pressure drop: ±10%

89
Molecular Filters

Products

Panel Filters Panel Filters Panel Filters Cylinders


CamCarb PM CamCarb PM V CamCarb PC CamCarb XG
Page 97 Page 98 Page 99 Page 100

Cylinders Cylinders Cylinders Cylinders


CamCarb CG CamCarb CM CamCarb Mounting Frames CamCube CC-L
Page 101 Page 102 Page 103 Page 104

Cylinders Compact Filters (Box Type) Compact Filters (Box Type) Compact Filters (Box Type)
CamCube HF-CC CamCarb VG PSSA GigaPleat XPC
Page 106 Page 107 Page 108 Page 109

As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

Compact Filters (Header Panel Filters Compact Filters (Header Compact Filters (Box Type)
Frame) GigaPleat NXPP Frame) GigaPleat NXPC
GigaPleat XPH Page 111 GigaPleat NXPH
Page 113
Page 110 Page 112

Compact Filters (Header Filters Bed


Compact Filters (Box Type) Filters Bed
Frame) ProCarb VDBe
GigaPleat NXDP (DH) HDB
GigaPleat NXDP (PH) Page 116
Page 114 Page 115 Page 116

90
Molecular Filters

Products

Filters Bed Filters Bed Filters Bed


HDC ProCarb VDBs HDB Biogas
Page 117 Page 117 Page 118
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

91
Molecular Filters | Information

Applicable Standards for Corrosion Control


Common Reference Standards
There are two commonly referenced standards that categorise environmental conditions in relation to the deployment and reliability of electronic
equipment:
1. IEC 60721-3-3
2. ANSI/ISA-71.04-2013.

IEC 60721-3-3 categorises environmental conditions based on several parameters such as climatic conditions, biological and chemical contaminants and
mechanical effects.

ANSI/ISA-71.04-2013
ANSI/ISA-71.04-2013 is the most popular and focuses on airborne contaminants and observed rates of corrosion for copper and silver metals.

ANSI/ISA-71.04-2013 defines 4 classes of air quality that relate to different rates of reactivity or corrosion of copper and silver. These are; G1 Mild, G2
Moderate, G3 Harsh and GX Severe.

For reference, the standard tabulates concentrations of different gases that approximately correspond to the 4 categories of copper reactivity. It is worth
noting that extremely low concentrations of some agents are required to achieve G1 Mild conditions.

Most original equipment manufacturers require provision of G1 Mild conditions as part of their warranty conditions since the standard states for class G1
that “Corrosion is not a factor in determining equipment reliability”. The external ambient air at some heavy process industries will routinely be classified
as GX Severe.

ISA Classification of reactive environments (ANSI/ISA 71.04-2013)


Environment sufficiently well Environment in which the Environment in which there is Environment in which only
controlled such that corrosion effects of corrosion are a high possibility that corrosive specialy designed and
is not a factor in determining measurable and may be attack will occur. These packaged equipment would
equipment reliability a factor in determining harsh levels should prompt be expected to survive
equipment reliability further evaluation resulting in
environmental controls

G1 G2 G3 GX
Security level
(MILD) (MODERATE) (HARSH) (SEVERE)

Copper reactivity level * <300 <1000 <2000 ≥2000

Silver reactivity level * <200 <1000 <2000 ≥2000

* In angstroms, normalized to a 30-day exposure

COPPER REACTIVITY LEVELS


(A/month)
G1 (MILD) G2 (MODERATE) G3 (HARSH) GX (SEVERE)

GROUP GAS GAS CONCENTRATION (parts per billion)


Hydrogen sulfide (H2S) <3 < 10 < 50 50

Sulfur dioxide (SO2)


< 10 < 100 < 300 300 As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
A Sulfur trioxide (SO3)

Chlorine (CI2) <1 <2 < 10 10

Nitrogen oxides (NOx) < 50 < 125 < 1,250 1,250

Hydrogen fluoride (HF) <1 <2 < 10 10

B* Ammonia (NH3) < 500 < 10,000 < 25,000 25,000

Ozone (O3) <2 < 25 < 100 100

* Reprinted by permission from ANSI/ISA-71.04-2013, copyright © ISA 2013

Note of caution :

The standard indicates concentrations of individual gases that loosely correspond to the 4 classes of corrosivity. If multiple gases are present in the air,
a synergistic effect on the observed rate of corrosion that is difficult to quantify may occur. As a consequence, on-site monitoring for a single or multiple
gases may not in itself predict or explain corrosion of silver and copper.

92
Molecular Filters | Information

Application matrix

DUTY VERY LIGHT LIGHT MODERATE MODERATE MODERATE HEAVY HEAVY VERY HEAVY

SENSITIVE CLEAN LIGHT CORROSION INDUSTRIAL EMERGENCY


SEGMENT IAQ COMFORT
ENVIRONMENT ROOMS PROCESS CONTROL EXHAUST PROTECTION

CITY CENTRE MUSEUM AND SEMI- SMALL PETROCHEM. WASTE


EXAMPLE AIRPORT REFUGE
OFFICE IVF CLINIC CONDUCTOR FACTORY PULP & PAPER HANDLING

CUSTOMER VERY VERY


NON-SPECIFIC SPECIFIC SPECIFIC SPECIFIC SPECIFIC SPECIFIC SPECIFIC SPECIFIC
PROBLEM

MAKE-UP CITY FAMILY / CAMCARB /


CAMCARB CAMCARB CAMCARB PROCARB PROCARB
AIR CAMCARB GIGAPLEAT

RECIRC. CITY FAMILY /


CITY FAMILY CITY FAMILY GIGAPLEAT CAMCARB CAMCARB PROCARB
(RETURN) AIR GIGAPLEAT

PROCARB /
EXHAUST
CAMCARB ACTICARB /
AIR
HEGA
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

TE
STED Molecular filter test equipment according to ISO 10121

ISO10121
ACCORDING
TO

93
Molecular Filters | Information

Why molecular filtration?


Air pollution caused by traffic, manufacturing, power plants, agriculture
and even forest fires is a growing problem in our industrialized world.
Molecular gaseous compounds are invisible and all around us. Some of
these compounds are so toxic, and yet so hard for us to detect, that
they can do us harm without even realizing we have been exposed.
Unfortunately we are routinely being subjected to such hazardous
compounds in our offices, our homes, our cities and even during our
leisure time.
The impact of such exposure can be significant. High ozone or volatile
organic compound (VOC) levels represent a serious health threat for
all of us. At the same time air pollution can damage everything from
valuable artifacts in museums to exposed surfaces in our homes and
offices.
In manufacturing environments Airborne Molecular Contamination (AMC)
can cause a variety of problems. In semiconductor manufacturing,
for example, AMC can reduce product yield, corrode valuable optical
components and damage a wide range of process equipment.
In other industries, as products and processes become more complex
and more sensitive to all types of contamination, the control of AMC
will become an ever more critical part of ensuring product quality and
improving process yield rates.

Test according to ISO 10121

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Additional services
Camfil offers a wide range of AMC focused services that allow our
customers to remain focused on their core business. These service
include filter life time analysis, real time online measurement of con-
taminants and passive sampling to precisely determine the type and
concentration of the problem compounds.
Once local analysis has been completed our AMC experts can propose
comprehensive AMC solutions based on the minimum possible Life
Cycle Cost available to meet customer needs.
Camfil is the only filter company equipped with a full size filter test
facility designed to performance test not just filter media samples but
also full size filters under precisely simulated conditions. This full size
filter testing is the basis for all our published technical data and can be
used to test filter performance against wide and varied range of AMC
challenges under precise temperature, humidity and air flow conditions.
This type of performance data can be invaluable when it comes to
determining the optimal solution for any specific AMC challenge.

94
Molecular Filters | Information

Molecular filtration technical services


Beyond Filtration Gas challenges
Camfil provides a comprehensive range of measurement services Camfil have a unique test facility that allows full scale molecular filters to
to complement their range of air filtration products. The services are be tested under conditions which precisely replicate those experienced in
used to assist in product selection, product validation and optimiza- actual applications.
tion of product performance. The molecular filtration test rig allows filters to be exposed to airflows
Where possible we base our testing on international standards to with a wide variety of temperatures and relative humidities.
ensure comparability and repeatability of results.
All our testing facilities are ISO 9001 : 2000 certified and measuring
equipment is calibrated traceable to national standard.
Site services
Camfil have the possibility to offer on-site support services. These may
include:
- Supply and fit of filters.
- Removal and disposal of waste material
- Supply and fill of new media and in=site performance validation.

CamPure Corrosion Coupons


On-line corrosion monitoring
CamPure or reactivity coupons are an economical and simple way to
assess the corrosive potential of an environment.
(AirImage-COR)
The coupons comprise of a pair of copper and silver foil strips which The AirImage-COR is an out-of-the-box solution to accurately monitor
are exposed to the environment. After a given period, the coupons are corrosion, temperature, relative humidity, and pressure (absolute or
returned to the laboratory where the surface corrosion is determined. differential). It is a vital tool for pro-tecting valuable electronic equipment
The types and relative amounts of corrosion on each metal are indica- and other objects from corrosion caused by airborne acidic gases.
tive of the corrosive agents in the air.
AirImage-COR measures and registers the change over time in the
Coupons may be used to assess an environment prior to selection and
electrical resistance (ER) of a thin metal track applied on an insulating
installation of a molecular filtration system and to validate the ongoing
substrate. If the metal corrodes, the cross sectional area of the track
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

performance after installation.


decreases and the ER increases. The changes in ER can be directly
Atmospheres may be classified according to the Instrument Society of
translated into corrosion depth and corrosion rate. AirImage-COR
America standard ISA-S71.04. Categories include Mild (G1). Moderate
measures loss of metal thickness and therefore the technique provides a
(G2), Harsh (G3) and Severe (GX).
direct correlation to corrosivity.

Residual Life Analysis / Gigamonitor


It is important to be able to predict the impending failure of a molecu-
lar filter due to saturation of the media. This may be achieved through
a programme of residual life analyses.
In this laboratory technique, a sample of media returned from the field
is analysed for the residual content of the impregnation or chemical
agent system.
A series of measurements made at 3 or 6 month interval allow the
eventual deterioration in the condition of the media to be anticipated
and plans put in place for a replacement.

95
Molecular Filters | Information

Molecular filtration technical services


Gigacheck™ Advanced Online Gas Monitoring
The Camfil Gigacheck™ is a passive analytical system to selectively If you need to understand the short term variation of airborne mo-
measure airborne molecular contaminants (AMC) in cleanrooms and lecular contaminant (AMC) concentrations in your cleanroom for an
accompanying air handling systems used for microelectronics and extended period of time, Camfil online monitoring equipment will be
integrated circuit manufacture. the perfect solution. Equipped with 8 sampling ports, our system is
able to measure the concentrations of Ammonia (NH3), Nitrogen Oxides
Other possible applications include museums, airports, hospitals and oil (NOx), Sulfur Dioxide (SO2), Hydrogen Sulfide (H2S) or total reduced
and gas industries. Sulfur compounds (TRS), down to a detection limit of 0.5 ppb(v). Data
Common contaminants of analysis include acids, acid precursors, are recorded and can be plotted into graphs showing concentration
bases and ozone. changes over time in different location of your cleanroom or process
equipments.
The kit and the samplers are supplied in a case and sealed plastic
bags. Our technology follows the recommendations of the International
The Gigacheck™ can be located inside the cleanroom, in a ventilation Technology Roadmap for Semicondutors (ITRS) for advanced air
duct, inside make-up air systems, or in a mini environment. A proven monitoring applications, using chemiluminescence technology for NOx
tool, it is small, light weight, cost effective, and does not require any and NH3, UV fluorescence detectors for SO2 and H2S, NH3 and Sulfur
electrical connections or field calibration. compounds are the most critical contaminants in semiconductor and
The only requirements are ambient temperature and normal airflow. microelectronic applications, resulting in serious yield losses and prod-
Sampling time is 1 day – 1 month depending on the application. The uct quality issues, even when present at trace levels. Please contact
Gigacheck™ provides average concentrations of AMC over the our local Camfil team of experts to assist you with your advanced
sampling period. online AMC measurements.
The Gigacheck™ is sealed and returned to our laboratory at the end of
the exposure period.
The resulting data and information about the ventilation system and the
process being protected allows us to design an optimized molecular
filtration system based on your specific site condition.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

96
Molecular Filters | Panel Filters

CamCarb PM
Advantages
• Suitable for high temperature • Predicted removal efficiency
applications above 60ºC and lifetime by Camfil’s
• Custom lengths, widths, and proprietary software
depths • Typical target gases: ozone,
• Stainless steel, galvanized nitrogen dioxide, sulfur dioxide,
steel, powder coated metal beta-myrcene, hydrocarbons,
construction VOCs
• Vibrated fill technique to
prevent media settlement

Application: Adsorption of odours and gases in air conditioning


applications
Frame: Stainless steel, Galvanised steel
Media: Activated Carbon, Impregnated Activated Carbon, Activated
Alumina
Max Temperature (°C): -21 to 80ºC
Relative Humidity max: 90%
Installation Options: Front and side access housings and frames are
available

Available in standard and custom sizes, CamCarb PM panels are high-quality molecular filtration panels for use in a variety of housings.
CamCarb PM panels may be filled with many different molecular filtration media to protect people, processes, the environment and
cultural artefacts.
CamCarb PM panels are a cost-effective method to deploy moderate amounts of carbon media.
The standard construction is galvanized steel with stainless steel as an option. Both face meshes are fitted with internal scrims to
eliminate shedding of fine particles and minimize dusting.

Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Optimum temperature (ºC) Optimum RH (%) Weight (kg)

CamCarb PM VOC_O3_NO2_SO2 600x 600x 24 680/ 125 Max. 40 0-70 9

CamCarb PM VOC_O3_NO2_SO2 300x 600x 24 340/ 125 Max. 40 0-70 4.5


Filters are available in a comprehensive range of sizes and depths. Please contact Camfil for more information.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

9
Molecular Filters | Panel Filters

CamCarb PM V
Advantages
• Reusable V cell housing • High performance
• Exchangeable loose-filled • Suitable for a wide range of air
panels volumes
• Cost optimized life cycle

Application: Adsorption of odours and gases in air conditioning


applications.
Media: Activated Carbon, Impregnated Activated Carbon, Activated
Alumina
Max Temperature (°C): Max 80°C
Relative Humidity max: 90%
Comment: Frame: Housing = Stainless steel, Panels = Galvanized
steel
Gasket: 01 = downstream, 10 = upstream

Type#1 Note Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Optimum temperature (ºC) Optimum RH (%) Weight (kg)

CamCarb PM V- DH: Box type 610x 610x 292 2600/ 300 Max. 40 0-70 80

CamCarb PM V DH: Box type 305x 610x 292 1100/ 300 Max. 40 0-70 42

CamCarb PM V PH: Single header 592x 592x 292 2600/ 180 Max. 40 0-70 40

CamCarb PM V PH: Single header 287x 592x 292 1100/ 180 Max. 40 0-70 22
#1-CamCarb PM V housing fitted with CamCarb PM VOC_O3_NO2_SO2.
Filters are available with different media options.High Performance media will be selected in accordance to the type of application.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.


Molecular Filters | Panel Filters

CamCarb PC
Advantages
• Reduced media bed density • Suitable for non-critical
when a lower pressure drop is applications in recirc or
required exhaust
• Lightweight construction • Typical target gases: ozone,
components nitrogen dioxide, sulfur dioxide,
and VOCs

Application: Adsorption of odours and gases in air conditioning


applications.
Type: Loose Fill Panel
Frame: Galvanised steel
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Rec. final pressure drop: Pressure drop in a loose-fill molecular
filter will remain unchanged. Periodic media sampling should be
conducted to determine the filter replacement frequency.
Max Temperature (°C): -21 to 80
Relative Humidity max: 90%
Installation Options: Front and side access housings and frames are
available

Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Optimum temperature (ºC) Optimum RH (%) Weight (kg)

CamCarb PC VOC_O3_NO2_SO2 594x 594x 47 850/ 70 Max. 40 0-70 7.5

CamCarb PC VOC_O3_NO2_SO2 594x 289x 47 425/ 70 Max. 40 0-70 4


Above are sample sizes, filters are available in a comprehensive range of sizes, please specify
Also available with stainless steel case
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.


Molecular Filters | Cylinders

CamCarb ;G
Advantages
• ,QKHUHQWO\OHDNIUHHGHVLJQ IRUPDOGHK\GHQLWURJHQGLR[LGH
ZKHQLQVWDOOHGLQGHGLFDWHG DQGRWKHUDFLGVDQGEDVHV
KDUGZDUH • 7KHFRQLFDOVKDSHSURYLGHVWKH
• &RUURVLRQUHVLVWDQWDQGORZ KLJKHVWUHPRYDOHIILFLHQF\DQG
GXVWLQJFRQVWUXFWLRQ ORZHVWSUHVVXUHGURS
• 3UHGLFWHGUHPRYDOHIILFLHQF\ • OLJKWHUWKDQPHWDO
DQGOLIHWLPHE\&DPILO V F\OLQGHUV
SURSULHWDU\VRIWZDUH • (UJRQRPLFILOWHUGHVLJQIRU
• 7\SLFDOWDUJHWJDVHVK\GURJHQ LPSURYHGKDQGOLQJ
VXOILGH92&VR]RQH

Application: 7KHPRVWUHOLDEOHPROHFXODUILOWHUIRUKLJKHIILFLHQF\
DQGORQJWHUPFRQWURORIPROHFXODUFRQWDPLQDQWVLQVHQVLWLYH
EXLOGLQJVDQGSURFHVVLQGXVWULHV
7KH\PD\DOVREHXVHGLQRGRXUUHPRYDODSSOLFDWLRQVLQSXOSDQG
SDSHUPLOOVDQGZDVWHZDWHUWUHDWPHQWSODQWVRUOLJKWHU
DSSOLFDWLRQVVXFKDVDLUSRUWVFXOWXUDOKHULWDJHEXLOGLQJVDQG
FRPPHUFLDORIILFHV
Type: Loose Fill Cylinder
Frame: $%6
Gasket: 2XWOHWVHDOPROGHG73(
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Max Temperature (°C): -21ºC to 0ºC
Installation Options: )URQWDFFHVVPRXQWLQJIUDPHVDQGVLGHDFFHVV
KRXVLQJVDUHDYDLODEOH6HHUHODWHGSURGXFWVEHORZ
Comment: 8QLYHUVDOPRXQWLQJNQREVWRDFFRPPRGDWHRUPP
PRXQWLQJIUDPHV6L[WHHQ  ;* VDUHDSSOLHGSHU[PP
[ RSHQLQJ&DQEHILOOHGZLWKDQ\ORRVHILOOPROHFXODUPHGLD

Type#1 Length (mm) Diameter (mm) Airflow/pressure drop (m³/h/Pa)#2 Optimum temperature (°C) Optimum RH (%) Nominal weight (kg)

CamCarb XG 2600 SO2_H2S^³ 452 146 2500/ 85 10-60 40-90 3.5

CamCarb XG 2600 Acids_H2S^³ 452 146 2500/ 85 10-60 40-90 3.5

CamCarb XG 2600 VOC 452 146 2500/ 95 Max. 40 0-70 2.3

CamCarb XG 2600 H2S_Mercaptans 452 146 2500/ 95 10-60 40-90 2.4

CamCarb XG 2600 Acids 452 146 2500/ 95 10-60 40-90 2.7

CamCarb XG 2600 VOC_O3_Acid_H2S 452 146 2500/ 95 10-40 40-70 2.9

CamCarb XG 2600 VOC_O3_NO2_SO2 452 146 2500/ 85 Max. 40 0-70 2.3

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CamCarb XG 2600 Bases 452 146 2500/ 95 10-60 40-90 2.7

CamCarb XG 3500 SO2_H2S^³ 595 146 3400/ 120 10-60 40-90 4.4

CamCarb XG 3500 Acids_H2S^³ 595 146 3400/ 120 10-60 40-90 4.4

CamCarb XG 3500 VOC 595 146 3400/ 125 Max. 40 0-70 2.9

CamCarb XG 3500 H2S_Mercaptans 595 146 3400/ 125 10-60 40-90 3.0

CamCarb XG 3500 Acids 595 146 3400/ 125 10-60 40-90 3.3

CamCarb XG 3500 VOC_O3_Acid_H2S 595 146 3400/ 125 10-40 40-70 3.7

CamCarb XG 3500 VOC_O3_NO2_SO2 595 146 3400/ 125 Max. 40 0-70 2.9

CamCarb XG 3500 Bases 595 146 3400/ 125 10-60 40-90 3.4
Filter performance will be affected if used in conditions where T and RH are above or below the optimum conditions.
#1 - Other models with different media options are available. High performance media will be selected in accordance to the type of application.
#2 - Pressure drop at maximum rated airflow.
^3 - Filled with UL approved media

10
Molecular Filters | Cylinders

CamCarb CG
Advantages
• Corrosion resistant and low • Predicted removal efficiency
dusting construction and lifetime by Camfil’s
• 25% lighter than CamCarb CM proprietary software
• Inherently leak-free design • Typical target gases: hydrogen
when installed in dedicated sulfide, VOC’s, ozone,
hardware formaldehyde, nitrogen
• Combines highest removal dioxide, and other acids and
efficiency and lowest pressure bases
drop

Application: The most reliable molecular filter for high efficiency and
long-term control of molecular contaminants in sensitive buildings
and process industries.
They may also be used in odour removal applications in pulp and
paper mills and wastewater treatment plants, or lighter applications
such as airports, cultural heritage building, and commercial offices.
Type: Loose Fill Cylinder
Frame: Plastic moulded
Gasket: Double seal, molded TPE
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Max Temperature (°C): -21ºC to 60ºC
Installation Options: Dedicated base plate in 2 standard sizes (1.5
mm and 2.0 mm thickness).
16 cylinders per 610x610 mm base plate. Half size, three quarter
and full size 610x610 base plates are available.
Comment: Filter performance will be affected if used in conditions
where T and RH are above or below the optimum conditions.
CamCarb CG can be used in Supply Air, Recirculation Air, and
Exhaust Air ventilation systems.

Type#1 Length (mm) Diameter (mm) Airflow/pressure drop (m³/h/Pa)#2 Optimum temperature (°C) Optimum RH (%) Nominal weight (kg)

CamCarb CG 1300 SO2_H2S^³ 240 148 1250/ 80 10-60 40-90 2.4

CamCarb CG 1300 Acids_H2S^³ 240 148 1250/ 80 10-60 40-90 2.4

CamCarb CG 1300 VOC 240 148 1250/ 80 Max. 40 0-70 1.6

CamCarb CG 1300 H2S_Mercaptans 240 148 1250/ 80 10-60 40-90 1.6

CamCarb CG 1300 Acids 240 148 1250/ 80 10-60 40-90 1.6

CamCarb CG 1300 VOC_O3_Acid_H2S 240 148 1250/ 100 10-40 40-70 2.0

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CamCarb CG 1300 VOC_O3_NO2_SO2 240 148 1250/ 60 Max. 40 0-70 1.5

CamCarb CG 1300 Bases 240 148 1250/ 80 10-60 40-90 1.6


#1 - Other models with different media options are available. High performance media will be selected in accordance to the type of application.
#2 - Pressure drop at rated air flow for 16 cylinders.
^3 - Filled with UL approved media

10
Molecular Filters | Cylinders

CamCarb CM
Advantages
• Ideal for high temperature • Predicted removal efficiency
applications above 60ºC and lifetime by Camfil’s
• Factory refillable proprietary software
• Inherently leak-free design • Typical target gases: VOCs,
when installed in dedicated ozone, nitrogen dioxide, sulfur
hardware dioxide
• Combines highest removal
efficiency and low pressure
drop

Application: The most reliable molecular filter for high efficiency and
long-term control of molecular contaminants in sensitive buildings
and process industries.
They may also be used in odour removal applications in pulp and
paper mills and wastewater treatment plants, or lighter applications
such as airports, cultural heritage building, and commercial offices.
Type: Loose Fill Cylinder
Frame: Stainless steel, Galvanised steel
Gasket: Rubber
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Max Temperature (°C): -21ºC to 80 ºC
Installation Options: Dedicated base plate in 2 standard sizes (1.5
mm and 2.0 mm thickness)
Comment: Filter performance will be affected if used in conditions
where T and RH are above or below the optimum conditions.
CamCarb CM can be used in Supply Air, Recirculation Air and
Exhaust Air ventilation systems.

Type#1 Length (mm) Diameter (mm) Airflow/pressure drop (m³/h/Pa)#2 Optimum temperature (°C) Optimum RH (%) Nominal weight (kg)

CamCarb CM 2600 VOC 450 145 2500/ 110 Max. 40 0-70 3.9

CamCarb CM 2600 H2S_Mercaptans 450 145 2500/ 110 10-60 40-90 3.9

CamCarb CM 2600 Acids 450 145 2500/ 110 10-60 40-90 3.9

CamCarb CM 2600 Bases 450 145 2500/ 110 10-60 40-90 3.9

CamCarb CM 3500 VOC 600 145 3400/ 190 Max. 40 0-70 5.2

CamCarb CM 3500 H2S_Mercaptans 600 145 3400/ 190 10-60 40-60 5.2

CamCarb CM 3500 Acids 600 145 3400/ 190 10-60 40-90 5.2

CamCarb CM 3500 Bases 600 145 3400/ 190 10-60 40-90 5.2
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

#1 - Other models with different media options are available. High performance media will be selected in accordance to the type ofapplication.
#2 - Pressure drop at rated air flow for 16 cylinders.

10
Molecular Filters | Cylinders

CamCarb Mounting Frames


Advantages
• Modular design adaptable for • Quick and easy service
all types of installations • Three standard sizes
• Rapid fitting system via • Assembly by bolting,
bayonet fitting rivets,welding

Application: Dedicated mounting frames to ensure leak-free


installation of CamCarb molecular filters in AHUs, ducts and
plenums
Frame: Stainless steel, Galvanised steel
Comment: Frame Thickness 1.5mm and 2.0mm
Applicable filters: CamCarb CM and CamCarb (Note : always
specify filter type when ordering as base plate thickness may vary to
accommodate different weights of filters).

Type Dimensions WxHxD (mm) Number of Cylinders Weight (kg)

G8 305x 610x 70 8 3

G12 457x 610x 70 12 5.7

G16 610x 610x 70 16 6


Available as 1.5mm or 2mm

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

10
Molecular Filters | Cylinders

CamCube CC-L
Advantages
• For CamCarb cylindrical • Leakage class C acc. EN 15727
molecular filters with max • Easy maintenance
depth 452 mm • Optional rail for particle
• Build-in thermal insulation prefilter panels
• Corrosivity class C4 for Aluzinc
housing material

Application: CamCube CC is a flexible and compact range of filter


housings for cylindrical molecular filters having a maximum length
of 452 mm. Two stage filtration is available as an option with a
mounting rail for 48 mm particle pre or after filters. Housings are
used in comfort and industrial applications.
Comment: Molecular filter types: CamCarb 1300/ 2600 or
CamCarb CM 2600 filled with different types of adsorbents.
depending on application. See the relevant catalogue page for
further information.
Particle filter types: Optional mounting rail for 48 mm particle pre or
after filters. All filters shall have external dimensions 592x592 mm.
Other standard features: Adjustable feet, factory mounted pressure
ports, guide for housing connection, 45 mm thermal insulation. The
door is hinged on the left or right and the orientation may also be
changed on site.
Other options: Lockable handles. Flange for housing connection.
Stainless steel SS EN 1.4301 housing material.

CamCube CC is a flexible and compact range of filter housings for cylindrical filters in length 450 mm.
Two stage filtration is available as an option with a prefilter or afterfilter mounting rail for panel filters.
The housing is a sandwich design with 45 mm heat and condensation insulation between, covered with aluzink sheet metal inside and
outside (corrosivity class C4).
The service hatch is hinged mounted.The endless gasket on the inside of the service hatch makes it highly airtight.
The filter housing has a leakage class of C according to EN 15727.
As standard the casing has M8 threads for mounting the filter housing. The filter housing is supplied with a guide connection, and a
flange connection is available as an option.

Accessories:
Prefilter or afterfilter mounting rail 50 mm
Lockable handles
Flange adaptor

Example specification text:


Filter housing: CamCube CC-1010.
Design: Sandwich construction with 45 mm heat and condensation insulation, covered with double aluzinc sheet metal (corrosivity class
C4)
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Leakage class C
Filter: 16 pcs Camcarb 2600 GZ D=145 mm L=450 mm CEX003

Classification:
Leakage class C, according to the EN 15727:2010 standard
Leakage class L1 according to the EN 1886:2007 standard
Mechanical performance: D1 according to the EN 1886:2007 standard

Type Dimensions WxHxD (mm) Inner flanges W1xH1 (mm) Number of Cylinders Weight (kg) Airflow at 0,1s (m³/h) Airflow at 0,2s (m³/h)

CamCube CC-L 0505 392x 392x 700 300x 300 4 24 650 310

CamCube CC-L 0510 392x 692x 700 300x 600 8 34 1300 620

CamCube CC-L 1005 692x 392x 700 600x 300 8 34 1300 625

CamCube CC-L 1010 692x 692x 700 600x 600 16 43 2600 1250

CamCubeCC-L 1015 692x 992x 700 600x 900 24 55 3900 1875

CamCube CC-L 1020 692x 1292x 700 600x 1200 32 64 5200 2500

CamCube CC-L 1025 692x 1592x 700 600x 1500 40 76 6500 3150

CamCube CC-L 1030 692x 1892x 700 600x 1800 48 85 7800 3750

CamCube CC-L 1510 992x 692x 700 900x 600 24 53 3900 1875

CamCube CC-L 1515 992x 992x 700 900x 900 36 66 5850 2810

CamCube CC-L 1520 992x 1292x 700 900x 1200 48 76 7800 3750

CamCube CC-L 1525 992x 1592x 700 900x 1500 60 89 9750 4685

CamCube CC-L 1530 992x 1892x 700 900x 1800 72 99 11700 5625

CamCube CC-L 2010 1292x 692x 700 1200x 600 32 62 5200 2500

10
Molecular Filters | Cylinders

Type Dimensions WxHxD (mm) Inner flanges W1xH1 (mm) Number of Cylinders Weight (kg) Airflow at 0,1s (m³/h) Airflow at 0,2s (m³/h)

CamCube CC-L 2015 1292x 992x 700 1200x 900 48 77 7800 3750

CamCube CC-L 2020 1292x 1292x 700 1200x 1200 64 86 10400 5000

CamCube CC-L 2025 1292x 1592x 700 1200x 1500 80 100 13000 6250

CamCubeCC-L 2030 1292x 1892x 700 1200x 1800 96 109 15600 7500

CamCube CC-L 2510 1592x 692x 700 1500x 600 40 74 6500 3125

CamCube CC-L 2515 1592x 992x 700 1500x 900 60 89 9750 4685

CamCube CC-L 2520 1592x 1292x 700 1500x 1200 80 98 13000 6250

CamCube CC-L 2525 1592x 1592x 700 1500x 1500 100 113 16250 7810

CamCube CC-L 2530 1592x 1892x 700 1500x 1800 120 123 19500 9375

CamCube CC-L 3010 1892x 692x 700 1800x 600 48 83 7800 3750

CamCube CC-L 3015 1892x 992x 700 1800x 900 72 99 11700 5625

CamCube CC-L 3020 1892x 1292x 700 1800x 1200 96 108 15600 7500

CamCube CC-L 3025 1892x 1592x 700 1800x 1500 120 124 19500 9375

CamCube CC-L 3030 1892x 1892x 700 1800x 1800 144 134 23400 11250

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

10
Molecular Filters | Cylinders

CamCube HF-CC
Advantages
• For CamCarb molecular • Leakage class C acc. EN 15727
filters with max depth 600 mm • Easy maintenance
• Build-in thermal insulation • Possible installation of 2
• Corrosivity class C4 for Aluzinc stages of particle filters
housing material

Application: CamCube HF-CC is a flexible range of filter housings for


cylindrical molecular filters having a maximum length of 600 mm,
combined with 1 stage of particle filters (bag or compact header)
and with an optional rail for particle pre-filter panels (48 or 96 mm
depth). Housings are used in comfort and industrial applications.
Max Temperature (°C): 60°C with plastic cylinders, 70°C with metal
cylinders.
Installation Options: Left hinged service door from factory, can be
changed on site.
Comment: Molecular filter types: CamCarb G or CamCarb CM filled
with different types of adsorbents depending on application. See the
relevant product catalogue page for further information.
Particle filter types: All filters shall have external dimensions
592x592 mm.
Optional first stage using 48 mm particle panel filters. 96 mm depth
is possible in certain configurations.
Second stage using bag filters such as Hi-Flo with maximum pocket
depth of 370 mm when combined with CamCarb /CM 3500 or a
depth of 520 mm when combined with other cylindrical products.
Alternative second stage using compact filters with 25 mm header
frames such as Opakfil.
Other standard features: Adjustable feet, factory mounted pressure
ports, guide for housing connection, 45 mm thermal insulation. The
door is hinged on the left or right and the orientation may also be
changed on site.
Other options: Lockable handles. Flange for housing connection.
Stainless steel SS EN 1.4301 housing material.
Filter housing material: Aluzinc (except handles, hinges and
accessories).

Product description: CamCube HF-CC is a flexible range of filter housing for bag filters, other filter types with 25mm HF and cylinder
filters. Three stage filtration is available as an option with a filter slide mounted. The housing has a sandwich design with 45mm heat
and condensation insulation between an outer and an inner shell of aluzinc (corrosivity class C4).
The filter housing holds leakage class C according to EN 15727.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

When the service hatch is closed the newly developed clamping device ensures a secure clamping of the filter.
As standard the casing has M8 threads for mounting adjustable feet.
The filter housing is supplied with guided connection as standard with flange connection as an option.

Type Dimensions WxHxD (mm) Inner flanges W1xH1 (mm) Weight (kg)

CamCube HF-CC 0510 392x 692x 1160 300x 600 60

CamCube HF-CC 0505 392x 392x 1160 300x 300 52

CamCube HF-CC 1010 692x 692x 1160 600x 600 77

CamCube HF-CC 1015 692x 992x 1160 600x 900 97

CamCube HF-CC 1020 692x 1292x 1160 600x 1200 113

CamCube HF-CC 1510 992x 692x 1160 900x 600 94

CamCube HF-CC 1520 992x 1292x 1160 900x 1200 135

CamCube HF-CC 2010 1292x 692x 1160 1200x 600 110

CamCube HF-CC 2015 1292x 992x 1160 1200x 900 136

CamCube HF-CC 2020 1292x 1292x 1160 1200x 1200 152

CamCube HF-CC 2030 1292x 1892x 1160 1200x 1800 193

CamCube HF-CC 2520 1592x 1292x 1160 1500x 1200 173

CamCube HF-CC 2530 1592x 1892x 1160 1500x 1800 218

CamCube HF-CC 3020 1892x 1292x 1160 1800x 1200 191

CamCube HF-CC 3025 1892x 1592x 1160 1800x 1500 219


Filter sizes: 287x287, 592x592, 287x592 and 592x287mm.
Depth: Pre-filter 48 mm, Bag filter 520 mm, Cylinder 450 or 452 mm.
Depth: Pre-filter 48 mm, Bag filter 370 mm, Cylinder 600 mm.

10
Molecular Filters | Compact Filters (Box Type)

CamCarb VG
Advantages
• V-cell molecular filter filled • UL 900
with any Camfil carbon or • Easily retrofitted in existing
CamPure media hardware or dedicated Camfil
• Integrated PET mesh allowing hardware
for smaller media and low • Suitable for commercial and
dusting industrial applications
• Predicted removal efficiency
and lifetime by Camfil’s
proprietary software

Application: Heavy duty disposable plastic Vee Cell Modules to


specifically treat corrosion control of electronic and electrical
equipment in heavy process industries. They may also be used in
odour removal applications in pulp and paper mills and wastewater
treatment plants, or lighter applications such as airports, cultural
heritage building and commercial offices.
Frame: ABS , PET
Gasket: EPDM, PU-foam
Media: Activated Carbon, Impregnated Activated Carbon,
Impregnated Activated Alumina
Max Temperature (°C): -21ºC to 80ºC
Installation Options: PSSA Housing, VG track
Comment: Filter performance will be affected if used in conditions
where T and RH are above or below the optimum conditions.
VG300 can be used in Supply Air Systems, while the VG440 can be
used in Supply Air and Recirculation Air Systems.

Number of modules Pressure drop Optimum temperature Optimum RH Nominal weight


Type#1 Dimensions WxHxD (mm)
per 610x610 area (Pa)#2 (°C) (%) (kg)

CamCarb VG300 SO2_H2S^³ 300x 300x 300 4 315 10 - 60 40 - 90 14.5

CamCarb VG300 Acids_H2S^³ 300x 300x 300 4 315 10 - 60 40 - 90 14.5

CamCarb VG300 VOC 300x 300x 300 4 500 Max. 40 0 - 70 10.0

CamCarb VG300 H2S_Mercaptans 300x 300x 300 4 500 10 - 60 40 - 90 10.0

CamCarb VG300 Acids 300x 300x 300 4 500 10 - 60 40 - 90 10.0

CamCarb VG300 VOC_O3_Acid_H2S 300x 300x 300 4 440 10 - 40 40 - 70 11.7

CamCarb VG300 VOC_O3_NO2_SO2 300x 300x 300 4 560 Max. 40 0 - 70 8.8

CamCarb VG300 Bases 300x 300x 300 4 500 10 - 40 40 - 90 10.0

CamCarb VG440 SO2_H2S^³ 300x 150x 440 8 94 10 - 60 40 - 90 6.5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CamCarb VG440 Acids_H2S^³ 300x 150x 440 8 94 10 - 60 40 - 90 6.5

CamCarb VG440 VOC 300x 150x 440 8 146 Max. 40 0 - 70 4.5

CamCarb VG440 H2S_Mercaptans 300x 150x 440 8 146 10 - 60 40 - 90 4.5

CamCarb VG440 Acids 300x 150x 440 8 146 10 - 60 40 - 90 4.5

CamCarb VG440 VOC_O3_Acid_H2S 300x 150x 440 8 120 10 - 40 40 - 70 5.6

CamCarb VG440 VOC_O3_NO2_SO2 300x 150x 440 8 142 Max. 40 0 - 70 4.7

CamCarb VG440 Bases 300x 150x 440 8 146 10 - 40 40 - 90 4.5


#1 - Other models with different media options are available. High performance media will be selected in accordance to the type of application.
#2 - Pressure drop at rated velocity of 1.25 m/s (250 fpm) for VG300 and 2.5 m/s (500 fpm) for VG440.
^³ - Filled with UL approved media

10
Molecular Filters | Compact Filters (Box Type)

PSSA
Advantages
• Positive filter clamping • May be used in multiple stages
mechanism • Double skin with insulation
• Leakage tested housing • No special tools required

Application: Leak free housing specifically designed for Vee Cell


modules which are installed at make-up air or recirculation air
systems.
Type: Housing
Comment: Type: Housing
Filter housing material : 1mm thick Aluzinc with a corrosion class of
C4. the shell of the unit is 50 mm thick, filled with 45mm mineral
wool insulation material.
Filter : Vee Cell Module for loose filled media, Camcarb VG. Filled
with different types of adsorbents depending on application,
Recommended face velocity: 1.25m/s.
Camfil PSSA housings are robustly constructed to reflect the industrial environment where they are used. An outer frame is clad with
double skinned and insulated body panels. Material options are available depending on the application. Hinged doors on the sides of
the housing allow access for loading/removing the CamCarb VG modules. The doors are sealed using a jointless pour-on PU gasket for
leak-tightness. The door closure handles incorporate a cam mechanism to ensure effective compression of the door seal.

The principal feature of PSSA housings is the inclusion of a unique positive clamping mechanism that ensures an effective seal is
achieved between the CamCarb VG filters and the internal framework in the housing, The eliminates internal by-passes, which are a
common features in competitor equipment. the clamps operate via a lead actuating screw, securing the cells into position. On units
greater than 1200 mm wide, access doors are provided on both sides of the housing.

Pre and after-filters are fitted in dedicated chambers upstream and downstream of the molecular media beds. The particle filters
are access through service doors on the side of the housing. Pre-and after-filters are held in the frame work by a robust clamping
mechanism. This ensures elimination of internal leaks. optional differential pressure loss gauges will be mounted on the side of the
housing.

The filters are provided with external inlet and outlet flanges to facilitate connection of ductwork using industry standard connections.

Classification:
Leakage class C, according to the EN 15727:2010 standard
Leakage class L1 according to the EN 1886:2007 standard
Mechanical strength Class D1 according to the EN 1886:2007 standard
Filter by pass leakage class F9 according to the EN 1886:2007 standard
No. of Modules No. of Modules
Type Inner flanges W1xH1 (mm) Velocity (m/s) Airflow at 0,1s (m³/h)
High Wide

VG300-0202 600x 600 1.25 2 2 1700

VG300-0302 600x 900 1.25 3 2 2600

VG300-0402 600x 1200 1.25 4 2 3400


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

VG300-0303 900x 900 1.25 3 3 3800

VG300-0502 600x 1500 1.25 5 2 4300

VG300-0602 600x 1800 1.25 6 2 5100

VG300-0403 900x 1200 1.25 4 3 5100

VG300-0503 900x 1500 1.25 5 3 6400

VG300-0404 1200x 1200 1.25 4 4 6800

VG300-0603 900x 1800 1.25 6 3 7700

VG300-0504 1200x 1500 1.25 5 4 8500

VG300-0604 1200x 1800 1.25 6 4 10200

VG300-0505 1500x 1500 1.25 5 5 10600

VG300-0605 1500x 1800 1.25 6 5 12800

VG300-0606 1800x 1800 1.25 6 6 15300

10
Molecular Filters | Compact Filters (Box Type)

GigaPleat XPC
Advantages
• Reduced waste through • High media cleanliness
reusable housing • Predicted removal efficiency
• Up to 2 media types can be and lifetime by Camfil’s
combined into the same filter proprietary software
• Exchangeable panels • Typical target gases: VOCs,
• Low outgassing components acids, bases, ozone

Application: Clean room recirculation air and clean room make up


air
Frame: Stainless steel
Sealant: Polyurethane
Max Temperature (°C): 40º C
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket Position: 01 - downstream, 10 - upstream
Configuration XPC: 2 layers of 8 panels / full size housing
Outgassing: Individually outgassing tested for VOC emissions on
request

Number of panels per Number of panels per Appr. weight with


Product Type Material Dimensions WxHxD (mm)
layer housing panels (kg)

Box Housing XPC 610x610x292 Stainless Steel 610x 610x 292 8 16 28

Box Housing XPC 305x610x292 Stainless Steel 305x 610x 292 4 8 28

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

XPC A Acids 610x 610x 292 2600/ 95 28

XPC B Bases 610x 610x 292 2600/ 95 28

XPC V Organics 610x 610x 292 2600/ 95 28

XPC A Acids 305x 610x 292 1100/ 95 16

XPC B Bases 305x 610x 292 1100/ 95 16

XPC V Organics 305x 610x 292 1100/ 95 16

XPC BA Bases, acids 610x 610x 292 2600/ 95 28

XPC AV Acids, organics 610x 610x 292 2600/ 95 28

XPC BV Bases, organics 610x 610x 292 2600/ 95 28

XPC BA Bases, acids 305x 610x 292 1100/ 95 16

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
XPC AV Acids, organics 305x 610x 292 1100/ 95 16

XPC BV Bases, organics 305x 610x 292 1100/ 95 16

1
Molecular Filters | Compact Filters (Header Frame)

GigaPleat XPH
Advantages
• Reduced waste through • Predicted removal efficiency
reusable housing and lifetime by Camfil’s
• Exchangeable panels proprietary software
• Low outgassing components • Typical target gases: VOCs,
• High media cleanliness acids, bases, ozone

Application: Clean room recirculation air and clean room make up


air
Frame: Stainless steel
Sealant: Polyurethane
Max Temperature (°C): 40º C
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket Position: 01 - downstream, 10 - upstream
Configuration XPH: 1 layers of 8 panels / full size housing
Outgassing: Individually outgassing tested for VOC emissions on
request

Dimensions WxHxD Number of panels Number of panels Appr. weight with


Product Type Material
(mm) per layer per housing panel (kg)

Header Housing XPH 592x592x292 Stainless Steel 592x592x292 8 8 17

Header Housing XPH 287x592x292 Stainless Steel 287x592x592 4 4 9

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

XPH A Acids 592x 592x 292 2600/ 60 17

XPH B Bases 592x 592x 292 2600/ 60 17

XPH V Organics 592x 592x 292 2600/ 60 17

XPH A Acids 287x 592x 292 1100/ 60 9

XPH B Bases 287x 592x 292 1100/ 60 9

XPH V Organics 287x 592x 292 1100/ 60 9


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Panel Filters

GigaPleat NXPP
Advantages
• Multiple media types can be • High media cleanliness
combined into the same filter • Predicted removal efficiency
• Individually VOC outgassing and lifetime by Camfil’s
tested proprietary software
• Extremely small form factor • Typical target gases: VOCs,
• Wide range of dimensions acids, bases, dopants,
• Low outgassing components refractories, ozone

Application: For clean room ceiling, Fan Filter Units, mini-


environment or process equipment
Frame: Anodized aluminium
Gasket: Polyurethane
Max Temperature (°C): 40ºC
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Knife position: KD - downstream, KU - upstream
Gasket Position: 01 - downstream, 10 - upstream, 11- Both
downstream and upstream
Faceguard Position: 02 - downstream, 20 - upstream, 22 - Both
downstream and upstream
Available filter depth without knife edge: 66, 90, 110, 150, 172 and
200 mm
Available filter depth with knife edge: 66 (+38), 90 (+38), 110 (+38),
150 (+15) mm
Outgassing: Individually outgassing tested for VOC emissions

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

NXPP B Bases 610x 610x 90 535/ 15 5

NXPP B Bases 1220x 610x 90 1070/ 15 10

NXPP A Acids 610x 610x 90 535/ 15 5

NXPP A Acids 1220x 610x 90 1070/ 15 10

NXPP V Organics 610x 610x 90 535/ 15 5

NXPP V Organics 1220x 610x 90 1070/ 15 10

NXPP ABV Bases, Acids, Organics 610x 610x 150 535/ 50 14

NXPP ABV Bases, Acids, Organics 1220x 610x 150 1070/ 50 28


Other dimensions and media combinations available on request. Adapter frames for FFU installation available on request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Compact Filters (Header Frame)

GigaPleat NXPH
Advantages
• Low pressure drop • Predicted removal efficiency
• Low weight and lifetime by Camfil’s
• Incinerable proprietary software
• Low outgassing components • Typical target gases: VOCs,
• High media cleanliness acids, bases, ozone

Application: Clean room recirculation air, clean room make up air


Frame: ABS
Sealant: Polyurethane
Max Temperature (°C): 40ºC
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket position: 01- downstream, 10 - upstream
Outgassing: Individually outgassing tested for VOC emissions on
request.

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

NXPH B Bases 592x 592x 292 3300/ 50 12

NXPH B Bases 592x 287x 292 1600/ 50 65

NXPH A Acids 592x 592x 292 3300/ 60 12

NXPH A Acids 592x 287x 292 1600/ 60 65

NXPH V Organics 592x 592x 292 3300/ 60 12

NXPH V Organics 592x 287x 292 1600/ 60 65


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Compact Filters (Box Type)

GigaPleat NXPC
Advantages
• Low pressure drop • Predicted removal efficiency
• Available in galvanized or and lifetime by Camfil’s
stainless steel proprietary software
• Low outgassing components • Typical target gases: VOCs,
• High media cleanliness acids, bases, ozone

Application: Clean room recirculation air, clean room make up air


Frame: Stainless steel, Galvanised steel, Aluminium
Sealant: Polyurethane
Max Temperature (°C): 40ºC
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket position: 01 - downstream, 10 - upstream
Outgassing: Individually outgassing tested for VOC emissions on
request

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

NXPC B Bases 610x 610x 292 2600/ 60 15

NXPC B Bases 305x 610x 292 1100/ 60 8

NXPC B Bases 595x 595x 292 2600/ 60 15

NXPC B Bases 289x 595x 292 1100/ 60 8

NXPC B Bases 592x 592x 292 2600/ 60 15

NXPC B Bases 287x 592x 292 1100/ 60 8

NXPC A Acids 610x 610x 292 2600/ 60 15

NXPC A Acids 305x 610x 292 1100/ 60 8

NXPC A Acids 595x 595x 292 2600/ 60 15

NXPC A Acids 289x 595x 292 1100/ 60 8

NXPC A Acids 592x 592x 292 2600/ 60 15

NXPC V Organics 610x 610x 292 2600/ 60 15

NXPC A Acids 287x 592x 292 1100/ 60 8

NXPC V Organics 305x 610x 292 1100/ 60 8

NXPC V Organics 595x 595x 292 2600/ 60 15

NXPC V Organics 289x 595x 292 1100/ 60 8

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
NXPC V Organics 592x 592x 292 2600/ 60 15

NXPC V Organics 287x 592x 292 1100/ 60 8

11
Molecular Filters | Compact Filters (Box Type)

GigaPleat NXDP (DH)


Advantages
• Multiple media types can be • Predicted removal efficiency
combined into the same filter and lifetime by Camfil’s
• Low pressure drop proprietary software
• Low outgassing components • Typical target gases: VOCs,
• Individually VOC outgassing acids, bases, dopants,
tested refractories, ozone
• High media cleanliness

Application: Clean room recirculation air, clean room make up air


Frame: Galvanised steel
Sealant: Polyurethane
Max Temperature (°C): 40ºC
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket Position: 01 - downstream, 10 - upstream
Outgassing: Individually outgassing tested for VOC emissions

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

NXDP B Bases 592x 592x 292 3300/ 50 15

NXDP B Bases 287x 592x 292 1600/ 50 10

NXDP A Acids 592x 592x 292 3300/ 50 15

NXDP A Acids 287x 592x 292 1600/ 50 10

NXDP V Organics 592x 592x 292 3300/ 50 15

NXDP V Organics 287x 592x 292 1600/ 50 10

NXDP ABV Bases, Acids, Organics 592x 592x 292 3300/ 140 20

NXDP ABV Bases, Acids, Organics 287x 592x 292 1600/ 140 12
Other media combinations available on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Compact Filters (Header Frame)

GigaPleat NXDP (PH)


Advantages
• Multiple media types can be • Predicted removal efficiency
combined into the same filter and lifetime by Camfil’s
• Low pressure drop proprietary software
• Low outgassing components • Typical target gases: VOCs,
• Individually VOC outgassing acids, bases, dopants,
tested refractories, ozone
• High media cleanliness

Application: Clean room recirculation air, clean room make up air


Frame: Galvanised steel
Sealant: Polyurethane
Max Temperature (°C): 40ºC
Relative Humidity max: 30% - 70%
Particle cleanliness: ISO Class 6
Comment: Gasket Position: 01 - downstream, 10 - upstream
Frame : PH = Single Header
Outgassing: Individually outgassing tested for VOC emissions

Type Target contaminant Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

NXDP B Bases 592x 592x 292 3300/ 5 15

NXDP B Bases 287x 592x 292 1600/ 5 10

NXDP A Acids 592x 592x 292 3300/ 5 15

NXDP A Acids 287x 592x 292 1600/ 5 10

NXDP V Organics 592x 592x 292 3300/ 5 15

NXDP V Organics 287x 592x 292 1600/ 5 10

NXDP ABV Bases, Acids, Organics 592x 592x 292 3300/ 1 0 20

NXDP ABV Bases, Acids, Organics 287x 592x 292 1600/ 1 0 12


Other target gas combinations are available on request.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Filter Beds

ProCarb VDBe
Advantages
• Low life cycle cost for exhaust • Large area footprint for
applications minimum foundation
• Leak-free design requirements
• Simple, safe and clean • Can handle air flows up to
procedure for filling filters 105,000 m³/h
• Easy maintenance access • Magnahelic filter gauges for
maintenance planning

Vertical Deep Bed filters (VDBe) are durable cost effective


molecular filtration solutions for exhaust streams from industrial
processes. This product is designed to ensure the very highest
levels of performance in those applications where the elimination
of toxic gases and odours is essential for operational security and/
or regulatory compliance. Performance is delivered in terms of
extremely high removal efficiency and the longest possible lifetime
per fill of filtration media. Standard features ensure reliable and
safe operation. Two equipment configurations are available with
airflow capacities ranging from 10,000 to 105,000 . Virtually
any molecular filtration media may be selected for use in the filters,
depending on the contaminant(s) to be controlled. VDBe filters
are completely passive in operation and require very little routine
maintenance.

HDB
Advantages
• Leak-free design • Can be used with any filtration
• Gravity assisted media media to target specific gases
unloading • Rectangular footprint for
• Corrosion resistant minimum use of plant room
• Very long contact time for space
optimised lifetime and high • Can handle air flows up to
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

level of protection 5,000 m³/h

The Horizontal Deep Bed filters (HDB) filter is a robust solution for
removing corrosive gases, odours or toxic gases from make-up air
and exhaust air systems with very high efficiency on a single pass
basis. The filters contain horizontal beds of molecular filtration
media that are retained on top of a horizontal perforated screen.
The air passes vertically through the media bed. The normal airflow
direction is upward, but this arrangement can be reversed in some
applications. The filters utilise a very deep bed of media and they
are particularly well suited to applications that combine low to
moderate airflows and relatively high contaminant concentrations.

A range of standard sizes accommodate flows from 500 m3/h to


5,000 m3/h. Pre and after-filters can be incorporated by the addition
of bolt-on housing to provide a total filtration solution. HDB filters
are safe and simple to install. They are completely passive in oper-
ation and require little or no routine maintenance beyond changing
the filters and media. Fans and variable speed drives can be incorpo-
rated as options.

11
Molecular Filters | Filter Beds

HDC
Advantages
• Leak-free design • Optional pre and after particle
• Flexible design for supply, filter sections
recirculation or exhaust air • Can handle air flows up to
• Refillable cells 24,400 m3/h
• Up to 2 stages for targeting
multiple gas

The HDC units (Horizontal Deep Cell) product is designed to


ensure high levels of performance in those applications where
the elimination of corrosive gases is essential to meet the
tightest environmental conditions that are specified by machinery
manufacturers. HDC’s are configured for horizontal airflow and
use a standard size re-fillable cell in either a single or double
pass arrangement, using this arrangement enables an engineered
approach to eliminating internal leaks that would otherwise degrade
performance. A range of standard housings are available to hold the
various quantities of HDC cells to provide airflow ranging from 1,100
to 24,400 m3/h. The media in the cells can be refurbished on-
site, without the need for special tools. HDCs can be supplied with
ducts, fans and discharge stacks.
The housings are designed to ensure ease of installation and
servicing procedures. Virtually any molecular filtration media may be
selected for use in the HDC cells, depending on the contaminant(s)
to be controlled. After commissioning the filters and housings
are completely passive in operation and require minimal routine
maintenance.

ProCarb VDBs
Advantages
• Low life cycle cost for • Double skin for internal
corrosion control temperature control
• Leak-free design • Multiple bed arrangement for
• Compact footprint with targetting multiple gases
integrated pre and after filters • Can handle air flows up to
28,000 m3/h

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Vertical Deep Bed Supply filters (VDBs) are members of the Camfil
“ProCarb” range of industrial molecular filtration solutions. This
product is designed to ensure the very highest levels of performance
in those applications where the elimination of corrosive gases is
essential to meet the tightest environmental conditions that are
specified by electrical equipment manufacturers. Heavy process
industries rely on sophisticated electronic control systems and
power distribution systems to operate their processes safely and with
high efficiency. In certain industries, acidic gases that are strongly
corrosive are present in the air. These gases are liberated from the
process raw materials. If left uncontrolled, these gases can degrade;
even destroy the electronic/electrical control systems.

11
Molecular Filters | Filter Beds

HDB Biogas
Advantages
• Leak-free design • Wide choice of adsorbent for
• Gravity assisted media H2S and siloxane removal
unloading • Can handle air flows up to
• Corrosion resistant 2,000 m³/h
• Very long contact time for
optimised lifetime

Horizontal Deep Bed Biogas (HDB-BG) filters are members of the


“ProCarb” range of industrial molecular filtration solutions. This
product is specifically designed for use in the purification of biogas,
particularly the removal of hydrogen sulphide and siloxanes. hese
are important process steps to protect the gas engines where biogas
is combusted to produce energy and heat.
Depending on the biogas feedstock and source, high concentrations
of one of both gases might be present. Hydrogen sulphide causes
corrosion and siloxanes cause erosion.

HDB-BG filters are designed to work at the elevated pressures


experienced in biogas processes and they provide extended contact
times necessary to handle the high contaminant concentrations and
ensure long lifetime.

Models are available to suit different biogas flow rates.


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

11
Molecular Filters | Information

Activated Carbon and Campure Media


Effective molecular filtration media Demanding applications
A comprehensive range of molecular filtration medias for the control Campure medias are designed for the most difficult and demanding
of corrosive gases, toxic gases, odours and other gaseous pollutants. applications in industrial and commercial environments. The principal
The medias may be used as part of original equipment packages or as areas of use include the control of acidic gases in pulp and paper, oil
replacement for spent media. refining, and steel production industries. If left untreated, acidic gases
The campure media range comprises chemically impregnated such as hydrogen sulphide, sulphur dioxide, chlorine and oxides of
adsorbents based on activated alumina which may be use on their own nitrogen may cause serious damage to key electrical equipment essen-
or blended with activated carbon. tial to process management. Other applications include the control
of acidic and odourous gases in waste water treatment applications and
the protection of sensitive artefacts in museums and art galleries.

Flexible filtration solutions and sup-


port services
Activated carbon and campure medias may be deployed in a range of
Camfil hardware systems. These allow standard and custom, solutions
for all industrial and commercial applications using various media
amounts and bed depths. Activated carbon and campure medias may
be re-filled directly into other manufacturers hardware.
These medias are supported by a comprehensive range of technical
support services including: media life analysis, corrosion monitoring
coupons, on-line monitoring and media handling.

Media Target gases Media type


CEX003 CEX004 VOCs, hydrocarbons, general odours Extruded activated carbon, 3 and
4mm diameter (coal based).

LGS036 LGS048 Light VOCs, hydrocarbons, general odours Granular activated carbon (coconut shell based).

Impregnated Carbon Acids, Alkalines, etc. A wide range of impregnation is available.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CamPure 4 H2S, SO2, formaldehyde, ethylene, low mol. wt. aldehydes. Activated alumina with chemical impregnation.

CamPure 8 High capacity for H2S, SO2 formaldehyde, ethylene, low mol. wt. aldehydes. Activated alumina with chemical impregnation.

CamPure 10 High capacity for H2S, SO2 formaldehyde, ethylene, low mol. wt. aldehydes Activated alumina with chemical impregnation.

CamPure 15 High capacity for acids Activated alumina with chemical impregnation.

CamPure 32 High capacity for H2S removal in biogas Hybrid media

CamPure D32PLUS High capacity for H2S and siloxane removal in biogas Activated carbon media

Blends Any of the Campure medias may be blended with either of the activated carbon based CP83 (CamPure 8 + CEX003)
medias to provide an adsorption system that combines broad spectrum and highly specific CP43 (CamPure 4 + CEX003)
characteristics.The usual blend ratio is 50/50 by volume. CP84 (CamPure 8 + CEX004)
CP44 (CamPure 4 + CEX004)

AMC filter media for pleated filters


AMC removal vs filter model V B A
Acids P

Bases P

Condensables (B.Pt > 150 deg. C) P S

Dopants (Organophosphates) P S

Dopants (BF3) P

Organics (B.Pt < 150 deg. C) P

Ozone P S

*P - Primary Target, S- Secondary Target


For specific contaminants, please contact Camfil

1
Housing, Frames Louvres

Products

Terminal Housings Terminal Housings Terminal Housings Terminal Housings


PHAP Pharmaseal AP PHAP® Exhaust AP Slimline RSR CleanSeal AP
Page 121 Page 123 Page 124 Page 125

Terminal Housings Terminal Housings Terminal Housings Terminal Housings


CleanSeal Top-C CleanSeal Side-C CleanSeal Side-R CamHosp 2
Page 127 Page 128 Page 129 Page 131

Terminal Filter Housings Terminal Filter Housings Safety Housings


Safety Housings
CamFFU EC CamFFU AC CleanSeal Extract Exhaust/Re-
CamSafe 3 -Housing
Page 132 Page 133 turn Air Housing
Page 134
Page 135
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

Safety Housings Ducted Housings Ducted Housings Filter Holding Frames


CamContain CS CamCube HF-L CamCube AS Absolute Filter Holding Frame
Page 136 Page 138 Page 140 Page 142

Filter Holding Frames Filter Holding Frames Weather Louvres Weather Louvres
Universal filter holding frame FastFrame CamVane 100 Dynavane
Page 143 Page 144 Page 145 Page 146

12
Housings, Frames & Louvres | Terminal Housings

PHAP Pharmaseal AP
Advantages
• Includes all essentials features • In-situ scanning with local
for pharmaceutical and health
care applications. is guaranteed.
• Quick filter change, quick • Heavy duty aluminium fully
upstream aerosol injection welded to ensure air-tight
dispersion, quick aerosol housing.
sampling and pressure test.

Application: Non-unidirectional (turbulent) airflow clean rooms in


pharmaceutical and health care applications.
Installation Options: Suspended by 4 lifting eyes or rested on ceiling
grid.
Comment: Type: Ceiling-mount ducted, room-side operatable air
supply module with gel-seal HEPA/ULPA filters and butterfly damper.
Construction: Casing of 2.8 mm extruded aluminium with fully
welded joints, powder coated as standard.
Filter seal: Self-healing, non-flowing silicon gel approved by Camfil
for pharmaceutical applications..
Duct connection: Mould drawn one piece, seamless aluminium inlet
collar sealed airtight to the back plate.
Damper: Room side adjustable heavy duty butterfly assembly with
air diffusion disk for even airflow distribution.
Challenge aerosol: Quick-connect airtight nickel plated brass port at
room side. Integrated aerosol-dispersion assembly for even aerosol
distribution.
Upstream aerosol sampling and pressure measurement: At
room side, a quick-connecting airtight port for pressure drop
measurement and upstream aerosol quick sampling to determine if
the upstream aerosol concentration is sufficient for filter scanning
test downstream.
Faceguard: Stainless steel or aluminium diffuser with swirling
blades, perforated style diffuser available as option, powder-coated if
required.

In-Situ scanning local min. Airflow/pressure drop


Art. No. Type Dimensions WxHxD (mm) Diameter (mm) Weight (kg)
efficiency @ 0.3 μm (m³/h/Pa)

Aluminium diffuser in center perforated and 4-way blades style

4130005C PHAP-476x476-A-TS-C10-A11-O-BS-A-P 476x 476x 254 99.99% 250 500/ 205 17.5

4130006C PHAP-635x635-A-TS-C12-A11-O-BS-A-P 635x 635x 254 99.99% 305 1000/ 205 23

4130007C PHAP-695x695-A-TS-C12-A11-O-BS-A-P 695x 695x 254 99.99% 305 1250/ 205 24.5

4130008C PHAP-756x756-A-TS-C14-A11-O-BS-A-P 756x 756x 254 99.99% 350 1500/ 205 27

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
4130009C PHAP-867x867-A-TS-C16-A11-O-BS-A-P 867x 867x 254 99.99% 405 2000/ 210 33

Aluminium diffuser in swirling style

4130010C PHAP-476x476-A-TS-C10-A31-O-BS-A-P 476x 476x 254 99.99% 250 500/ 205 17.5

4130011C PHAP-635x635-A-TS-C12-A31-O-BS-A-P 635x 635x 254 99.99% 305 1000/ 205 23

4130012C PHAP-695x695-A-TS-C12-A31-O-BS-A-P 695x 695x 254 99.99% 305 1250/ 205 24.5

4130013C PHAP-756x756-A-TS-C14-A31-O-BS-A-P 756x 756x 254 99.99% 350 1500/ 205 27

4130014C PHAP-867x867-A-TS-C16-A31-O-BS-A-P 867x 867x 254 99.99% 405 2000/ 210 33

4130015C PHAP-476x476-A-TS-C10-A21-O-BS-A-P 476x 476x 254 99.99% 250 500/ 205 17.5

4130016C PHAP-635x635-A-TS-C12-A21-O-BS-A-P 635x 635x 254 99.99% 305 1000/ 205 23

4130017C PHAP-695x695-A-TS-C12-A21-0-BS-A-P 695x 695x 254 99.99% 305 1250/ 205 24.5

4130018C PHAP-756x756-A-TS-C14-A21-0-BS-A-P 756x 756x 254 99.99% 350 1500/ 205 27

4130019C PHAP-867x867-A-TS-C16-A21-0-BS-A-P 867x 867x 254 99.99% 405 2000/ 210 33

4120151C PHAP-476x476-A-TS-C1O-S30-0-BS-A-P 476x 476x 254 99.99% 250 500/ 205 19

4130001C PHAP-635x635-A-TS-C12-S30-0 -BS-A-P 635x 635x 254 99.99% 305 1000/ 205 26

4130002C PHAP-695x695-A-TS-C12-S30-0-BS-A-P 695x 695x 254 99.99% 305 1250/ 205 28

4130003C PHAP-756x756-A-TS-C14-S30-0-BS-A-P 756x 756x 254 99.99% 350 1500/ 205 31

4130004C PHAP-867x867-A-TS-C16-S30-0-BS-A-P 867x 867x 254 99.99% 405 2000/ 210 38


Tolerance of pressure drop is +/- 15%. 0ther dimensions are available on request
0nly 0305 and 0350 inlet collars are mould drawn one-piece
*Note : Please refer to the next 2 tables of ‘ Model number system’ for model selection per detail options

12
Housings, Frames & Louvres | Terminal Housings

Model Number System For HEPA Supply Module


PHAP-. 695x695- A- TS- C12- S 1 0- 0- BS- A- P-

1 2 3 4 5 6 7 8 9 10 11 12

Naming Description

Pharmaseal AP HEPA supply module

476x476 635x635 695x695 756x756 867x867


*if other sizes, please state

A=Heavy duty extruded Aluminium (standard) S=Stainless Steel 304#(optional)

TS=Top Side (Standard) SS=Side

C12=Round, 12”=305mm C14=Round, 14”=350mm Other sizes are fully welded instead
of mould-drawn one piece
Mould-drawn top inlet collar and top plate of one-piece
aluminium (standard):

A=Aluminium S=Stainless steel 304

1=Center perforated and 4-way 2=ully perforated 3=Swirling 4=Other style (specify separately)
blades surrounded style

1=Powder coated (standard color RAL9016 or specify) 0=No coating

I=Inside the hood (within) 0=Outside the hood (extended)

BS= Butterfly damper, Stainless steel 304 NO= No damper

A = Yes (air tight quick connect) N = No

P = Yes (air tight quick-connect) N = No

Filter Element
Housing Dimensions Airflow/pressure drop
Art. No. Type PHF Size (mm) Efficiency Weight (kg)
WxHxD (mm) (m³/h/Pa)

15218202C PHF-LSS- 416x416-01/22 416x 416x 110 476x 476x 254 500/ 205 H14 4.1

15218215C PHF-LSS- 575x575-01/22 575x 575x 110 635x 635x 254 1000/ 205 H14 6.5

15218208C PHF-LSS- 635x635-01/22 635x 635x 110 695x 695x 254 1250/ 205 H14 7.6

15218213C PHF-LSS-696x696-01/22 696x 696x 110 756x 756x 254 1500/ 205 H14 8.8

15218232C PHF-LSS-807x807-01/22 807x 807x 110 867x 867x 254 2000/ 210 H14 12.2
Tolerance of pressure drop is +/- 15%
0ther dimensions are available on reques
*Note : Please refer to the next 2 tables of ‘ Model number system’ for model selection per detail options

Model Number System for Filter Element


PHAP-. LSS- 635x635- 01/- 22-

1 2 3 4 5

Naming Description
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Pharmaseal AP filter element

LSS : Liquid Seal, Special (Silicone gel)

416x416 575x575 635x635 807x807 Other odd sizes required,


please specify

01=Air Outlet Side (Standard) 10 : Air Inlet Side

22 : Both Sides (standard)

12
Housings, Frames & Louvres | Terminal Housings

Advantages
• Includes all essential functions • Heavy duty aluminium or
for pharmaceutical and bio- stainless steel fully welded
cleanroom applications to ensure the airtight robust
• In-situ efficiency 99.97% or construction
higher is guaranteed • All ports of injection and
• High capacity “V” -bank HEPA samplings are of air tight
filter inside results in low quick-connection design
pressure drop, low energy cost
and long service life.

Application: Exhaust/return air system for pharmaceutical and bio-


cleanroom applications
Frame: Stainless steel, Aluminium
Installation Options: Side wall mounted with site-made metal
brackets (instructed but not supplied by Camfil).
Comment: Type: Wall-mount, room side operatable, efficiency tested
exhaust/return air housing with Sofilair filters.
Construction: Aluminium or stainless steel 304 fully welded, powder
coated if required.
Filter seal: Endless PU gasket on filter.
Outlet connection: Flanged rectangular duct connection.
Damper: Room-side adjustable butterfly damper assembly, stainless
steel #304.
Room-side grill: Stainless steel 304, or aluminium painted.
Movable room-side,functions for upstream
aerosol injection and dispersion, upstream & downstream aerosol
sampling.
Accessory: Downstream sampling kit along with every housing
supplied.

Art. No. Type Dimensions WxHxD (mm) Prefilters WxHxD (mm) Filter size HxWxD (mm) Weight (kg) Filter Dimension (WxH) mm

4200007C PWAP- 670x670- S-A21- BS 670x 670x 880 595x 595x 45 610x 610x 292 26 500x 400

4200008C PWAP- 670x365- S-A21- BS 365x 670x 880 289x 594x 45 610x 305x 292 17 250x 400
Note: Tolerance of the pressure drop data within +/- 20% as standard.
Please refer to next “Model Number System” for model selection per detail option

Model Number System


PHAP-. 670x670 S- S 2 0 BS-

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
1 2 3 4 5 6 7

Naming Description

Pharmaseal AP Wall Mount Exhaust/Return Air HEPA Housing

670x670x880 (with Sofilair filter 610x610x292mm)

670x365x880 (with Sofilair filter 305x610x292mm)

S= Side Outlet (for upwards or downwards), standard

B=Back Outlet

2 = Fully perforated, standard

0= No treatment or Coating

1=Powder coated, RAL 9016, for other color, please separately

2=Other Style, please state separately

BS = Butterfly damper, stainless steel #304

No=No damper

12
Housings, Frames & Louvres | Terminal Housings

Slimline RSR
Advantages
• Low Profile • Adjustable room side diffusion
• Room side replaceable HEPA disc
filter module • Gel seal between filter and
• Housing can be installed from housing
room and top side • Noise reducing rounded collar
• Gap free, architecturally • Welded housing
pleasing room side surface

Filter
Application: Microelectronic, Hospitals, Life science
Type: Hood Filter
Frame: Anodized aluminium
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
MPPS efficiency:
93° C
Comment:
Fire rating: UL 900
Housing
Frame: Extruded aluminium
Back plate: Hot dipped galvanized steel

Filter
Art. No. Type EN1822 Filter size HxWxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

15290001 Slimline RSR - 600*600 H13 600x 600x 4.5/ 121 6.98 4.7

15290002 Slimline RSR - 905*600 H13 600x 905x 680/ 120 11.1 6.6

15290003 Slimline RSR - 1210*600 H13 600x 1210x 947/ 119 15.46 7.9

Housing
Art. No. Type Dimensions WxHxD (mm) Con. Ø (mm) Area (m²) Weight (kg)

4109001 SLM Housing 600*600* Ø250 600x 600x 133 250 6.98 9.72

4109002 SLM Housing 905*600* Ø305 905x 600x 133 305 11.1 9.8

4109003 SLM Housing 1210*600* Ø305 1210x 600x 133 305 15.46 9.91
*Other dimensions, finishes and different options are available on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

12
Housings, Frames & Louvres | Terminal Housings

CleanSeal AP
Advantages
• Aesthetic pleasing room side • Fits Camfil standard MD/MG/
appearance MX cleanrooms panels with dry
• Tool free, single person filter or gel seal
installation • Noise reducing rounded
• Several mounting options terminal
• Leak free design with welded
corners

Application: Turbulent airflow in clean rooms


Frame: Galvanised steel
Gasket: Polyurethane
Comment: Construction: Aluminium, Galvanized steel, fully welded
seams
Finishing: RAL9016
Connection: By ribbed circular inlet continuous welded on top
For Filters: MEGALAM MD/MX/MD PU gasket frame height
(66/90/110mm) (to be ordered separately)
Filter Mounting: Tool-less multi-height quick release lever clamp for
immediate and secured clamping including gasket compression
limiter and filter retainer.
Control equipment: room side access: 1 port for dp or 100%
measurement.
Housing installation: by removable «universal blocks, for suspension
by hangers, or integration into clean room ceiling panels or fitting
into T bar grids system
Diffusion plates: Perforated or swirl

Housing Gasket
Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Diffusers

4108001 CL-AL-4P4-P-MD-T-C-250-00-AAA0 539x 539x 260/250 457x 457x 66 Perforated

4108002 CL-AL-5P5-P-MD-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 66 Perforated

MD 4108003 CL-AL-5P5-P-MD-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 66 Swirl

4108004 CL-AL-6P6-P-MD-T-C-250-00-AAA0 692x 692x 260/250 610x 610x 66 Perforated

4108005 CL-AL-11P5-P-MD-T-C-250-00-AAA0 1190x 590x 260/250 508x 1108x 66 Perforated

4108006 CL-AL-12P6-P-MD-T-C-250-00-AAA0 1302x 692x 260/250 610x 1220x 66 Perforated

4108007 CL-AL-4P4-P-MX-T-C-250-00-AAA0 539x 539x 260/250 457x 457x 90 Perforated

4108008 CL-AL-5P5-P-MX-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 90 Perforated

MX 4108009 CL-AL-5P5-P-MX-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 90 Swirl

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
4108010 CL-AL-6P6-P-MX-T-C-250-00-AAA0 692x 692x 260/250 610x 610x 90 Perforated

4108011 CL-AL-11PS-P-MX-T-C-250-00-AAA0 1190x 590x 260/250 508x 1108x 90 Perforated

4108012 CL-AL-12P6-P-MX-T-C-250-00-AAA0 1302x 692x 260/250 610x 1220x 90 Perforated

4108013 CL-AL-4P4-P-MG-T-C-250-00-AAA0 539x 539x 260/250 457x 457x 110 Perforated

MG 4108014 CL-AL-5P5-P-MG-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 110 Perforated

4108015 CL-AL-5P5-P-MG-T-C-250-00-AAA0 590x 590x 260/250 508x 508x 110 Swirl

4108016 CL-AL-6P6-P-MG-T-C-250-00-AAA0 692x 692x 260/250 610x 610x 110 Perforated

4108017 CL-AL-11P5-P-MG-T-C-250-00-AAA0 1190x 590x 260/250 508x 1108x 110 Perforated

4108018 CL-AL-12P6-P-MG-T-C-250-00A- AA0 1302x692x260/250 1220x610x110 Perforated


*305mm,315mm & 350mm drawn type collar size available on request.
Gasket : P-PU & G-Gel

12
Housings, Frames & Louvres | Terminal Housings

Housing Gel
Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Diffusers

4108019 CL-AL-4P4-G-MD-T-C-250-00-AAAO 539x 539x 260/250 457x 457x 71 Perforated

4108020 CL-AL-5P5-G-MD-T-C-250-00-AAAO 590x 590x 260/250 508x 508x 71 Perforated

MD 4108021 CL-AL-5P5-G-MD-T-C-250-00-AAAO 590x 590x 260/250 508x 508x 71 Swirl

4108022 CL-AL-6P6-G-MD-T-C-250-00-AAAO 590x 692x 260/250 610x 610x 71 Perforated

4108023 CL-AL-11P5-G-MDT-C-250-00-AAAO 692x 590x 260/250 508x 1108x 71 Perforated

4108024 CL-AL-12P6-G-MD-T-C-250-00-AAAO 1190x 692x 260/250 610x 1220x 71 Perforated

4108025 CL-AL-4P4-G-MX-T-C-250-00-AAAO 1302x 539x 260/250 457x 457x 105 Perforated

4108026 CL-AL-5P5-G-MX-T-C-250-00-AAAO 539x 590x 260/250 508x 508x 105 Perforated

MX 4108027 CL-AL-5P5-G-MX-T-C-250-00-AAAO 590x 590x 260/250 508x 508x 105 Swirl

4108028 CL-AL-6P6-G-MX-T-C-250-00-AAAO 590x 692x 260/250 610x 610x 105 Perforated

4108029 CL-AL-11P5-G-MX-T-C-250-00-AAAO 692x 590x 260/250 508x 1108x 105 Perforated

4108030 CL-AL-12P6-G-MX-T-C-250-00-AAAO 1190x 692x 260/250 610x 1220x 105 Perforated

4108031 CL-AL-4P4-G-MG-T-C-250-00-AAAO 1302x 539x 260/250 457x 457x 115 Perforated

4108032 CL-AL-5P5-G-MG-T-C-250-00-AAAO 539x 590x 260/250 508x 508x 115 Perforated

MG 4108033 CL-AL-5P5-G-MG-T-C-250-00-AAAO 590x 590x 260/250 508x 508x 115 Swirl

4108034 CL-AL-6P6-G-MG-T-C-250-00-AAAO 590x 692x 260/250 610x 610x 115 Perforated

4108035 CL-AL-11P5-G-MG-T-C-250-00-AAAO 692x 590x 260/250 508x 1108x 115 Perforated

4108036 CL-AL-12P6-G-MG-T-C-250-00-AAAO 1190x 692x 260/250 610x 1220x 115 Perforated


*305mm,315mm & 350mm drawn type collar size available on request.
Gasket : P-PU & G-Gel
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

12
Housings, Frames & Louvres | Terminal Housings

CleanSeal Top-C
Advantages
• Tool-less filter clamping 100% • Long lasting reliability and
secured and immediate tightness: robust fully welded
• Quick grid locking for construction
immediate access to filter • Complete interchangeable
diffusion plates range

Application: Turbulent airflow in clean rooms


Comment: Construction: Steel, fully welded seams
Finish: White epoxy coated RAL 9010 (SW)
Available in material SS 304 (S4) and SS 316L (S6)
Filters and air diffusers must be ordered separately:
Filters: MEGALAM MD/MX/MD. PU gasket frame height
(66/90/110mm)
Air diffusers: Swirl-(SW), Perforated- (PF) Adjustable - (AV) and Four
way diffuser (4W)
For more information about filters and air diffusers, see the relevant
product pages
Gasket type options: PU and GEL
Control equipment: Room side accessible pressure drop port

The CleanSeal is a reliable and versatile filter housing especially developed for hospitals, clean rooms and Life Science facilities. This
terminal housing equipped with Camfil´s premium HEPA filters makes an ideal solution to achieve the high demands on air cleanliness
by minimizing the number of particles and microorganisms in the air.
CleanSeal is available in several standard sizes and different types of connections/configurations.
The filter clamping system is adjustable for different filter depths. This scalability allows an upgrade of existing filter to a deeper filter
with lower pressure drop. Low pressure drop filters can be used either to maintain pressure cascades or to get energy savings.
Thanks to the tool-less filter clamping and unique filter retainer, the handling and maintenance if very easy.
The filter is pre-positioned in the housing which makes it possible to handle by only one person.
The installation of the housing is very easy with supporting blocks.
The hinged diffusor plate gives direct access to the filter and control ports and is opened with just a badge/card.
Consult Camfil office for additional information.

Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Con. Ø (mm) Weight (kg)

CL-SW-3P3-(X1)-XX-(X2)-C-160-N-00-(X3)AA0 392x 392x 311 305x 305x 66 160 6.7

CL-SW-4P4-(X1)-XX-(X2)-C200-N-00-(X3)AA0 544x 544x 311 457x 457x 66 200 10.1

CL-SW-4P4-(X1)-XX-(X2)-C250-N-00-(X3)AA0 544x 544x 311 457x 457x 66 250 10

CL-SW-5P5-(X1)-XX-(X2)-C250-N-00-(X3)AA0 595x 595x 311 508x 508x 66 250 11.3

CL-SW-5P5-(X1)-XX-(X2)-C315-N-00-(X3)AA0 595x 595x 311 508x 508x 66 315 11.1

CL-SW-6P6-(X1)-XX-(X2)-C250-N-00-(X3)AA0 697x 697x 311 610x 610x 66 250 14.1

CL-SW-6P6-(X1)-XX-(X2)-C315-N-00-(X3)AA0 697x 697x 311 610x 610x 66 315 13.9

CL-SW-11P5-(X1)-XX-(X2)-C315-N-00-(X3)AA0 1195x 595x 311 1108x 508x 66 315 19.1

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CL-SW-12P6-(X1)-XX-(X2)-C315-N-00-(X3)AA0 1307x 697x 311 1220x 610x 66 315 22.7
ATTENTION : references for housing factory set Megalam MD (other settings on request)
NOTE 1 : (*) : INCLUDING PERIPHERAL RETURN OF20mm
NOTE 2 : (**) : INCLUDING COLLAR HEIGHT OF 46mm
NOTE 3 : (***) : For ordering: To select filter frame height replace “xx” with “MD” for Megalam MD-66mm, “MX” for Megalam MX-90mm and “MG” for Megalam MG-110mm
NOTE 4 : (X1) : P for PU & G for Gel
NOTE 5 : (X2) : T for Top Entry & S for Side Entry
NOTE 6 : (X3) : A for PU & G for Gel
SW= Standard version steel white RAL 9010 (Optional S4=Stainless steel SS 304, S6= SS 316L)

12
Housings, Frames & Louvres | Terminal Housings

CleanSeal Side-C
Advantages
• Tool-less filter clamping 100% • Long lasting reliability and
secured and immediate tightness: robust fully welded
• Quick grid locking for construction
immediate access to filter • Option with damper
• Complete interchangeable
diffusion plates range

Application: Turbulent airflow in clean rooms


Comment: Construction: Steel, fully welded seams
Finish: White epoxy coated RAL 9010 (SW)
Available in material SS 304 (S4) and SS 316L (S6)
Filters and air diffusers must be ordered separately:
Filters: MEGALAM MD/MX/MD.PU gasket frame height
(66/90/110mm)
Air diffusers: Swirl-(SW), Perforated- (PF) Adjustable - (AV) and Four
way diffuser (4W)
For more information about filters and air diffusers, see the relevant
product pages
Gasket type options : PU and GEL
Control equipment: Room side accessible pressure drop port
Option: with damper
The CleanSeal is a reliable and versatile filter housing especially developed for hospitals, clean rooms and Life Science facilities. This
terminal housing equipped with Camfil´s premium HEPA filters makes an ideal solution to achieve the high demands on air cleanliness
by minimizing the number of particles and microorganisms in the air.
CleanSeal is available in several standard sizes and different types of connections/configurations.
The filter clamping system is adjustable for different filter depths. This scalability allows an upgrade of existing filter to a deeper filter
with lower pressure drop. Low pressure drop filters can be used either to maintain pressure cascades or to get energy savings.
Thanks to the tool-less filter clamping and unique filter retainer, the handling and maintenance if very easy.
The filter is pre-positioned in the housing which makes it possible to handle by only one person.
The installation of the housing is very easy with supporting blocks.
The hinged diffusor plate gives direct access to the filter and control ports and is opened with just a badge/card.
Consult Camfil office for additional information.
Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Con. Ø (mm) Weight (kg)

CL-SW-3P3-P-xx-S-C-160-N-00-AAA0 367x 355x 410 305x 305x 160 9,2

CL-SW-3P6-P-xx-S-C-200-N-xx-AAA0 * 660x 367x 450 305x 610x 200 14,4

CL-SW-4P4-P-xx-S-C-200-N-00-AAA0 519x 507x 450 457x 457x 200 14,7

CL-SW-4P4-P-xx-S-C-250-N-00-AAA0 519x 507x 500 457x 457x 250 15,5

CL-SW-5P5-P-xx-S-C-250-N-00-AAA0 570x 558x 500 508x 508x 250 17,5

CL-SW-5P5-P-xx-S-C-315-N-00-AAA0 570x 558x 565 508x 508x 315 18,7


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

CL-SW-6P6-P-xx-S-C-250-N-00-AAA0 672x 660x 500 610x 610x 250 21,2

CL-SW-6P6-P-xx-S-C-315-N-00-AAA0 672x 660x 565 610x 610x 315 22,7

CL-SW-9P6-P-xx-S-C-315-N-xx-AAA0 * 965x 672x 565 610x 915x 315 29,8

CL-SW-9P6-P-xx-S-C-355-N-xx-AAA0 * 965x 672x 605 610x 915x 355 31,0

CL-SW-9P9-P-xx-S-C-315-N-00-AAA0 977x 965x 565 915x 915x 315 37,8

CL-SW-9P9-P-xx-S-C-355-N-00-AAA0 977x 965x 605 915x 915x 355 39,3

CL-SW-11P5-P-xx-S-C-315-N-xx-AAA0 * 1158x 570x 565 508x 1108x 315 31,1

CL-SW-11P5-P-xx-S-C-355-N-xx-AAA0 * 1158x 570x 605 508x 1108x 355 32,4

CL-SW-12P6-P-xx-S-C-315-N-xx-AAA0 * 1270x 672x 565 610x 1220x 315 36,4

CL-SW-12P6-P-xx-S-C-355-N-xx-AAA0 * 1270x 672x 605 610x 1220x 355 37,9


The item types in the table are PU versions (for filters with PU gasket). Other sizes and variants on request.
For ordering: To select filter frame height replace “xx” with “MD” for Megalam MD, “MX” for Megalam MX and “MG” for Megalam MG
*Entry Position (xx) : 00 - All Square, LS - Long Side and SS - Short Side
SW= Standard version steel white RAL 9010 (Optional S4=Stainlesss steel SS 304, S6= SS 316L)
P= PU version & G= GEL version

12
Housings, Frames & Louvres | Terminal Housings

CleanSeal Side-R
Advantages
• For limited space above false • Complete interchangeable
ceiling diffusion plates range
• Tool-less filter clamping 100% • Long lasting reliability and
secured and immediate tightness: robust fully welded
• Quick grid locking for construction
immediate access to filter

Application: Turbulent airflow in clean rooms, especially suitable for


applications with limited space above the false ceiling
Comment: Construction: Steel, fully welded seams
Finish: White epoxy coated RAL 9010 (SW)
Available in material SS 304 (S4) and SS 316L (S6)
Filters and air diffusers must be ordered separately:
Filters: MEGALAM MD/MX/MD.PU gasket frame height
(66/90/110mm)
Air diffusers: Swirl-(SW), Perforated- (PF) Adjustable - (AV) and Four
way diffuser (4W)
For more information about filters and air diffusers, see the relevant
product pages
Gasket type options: PU and GEL
Control equipment: Room side accessible pressure drop port

The CleanSeal is a reliable and versatile filter housing especially developed for hospitals, clean rooms and Life Science facilities. This
terminal housing equipped with Camfil´s premium HEPA filters makes an ideal solution to achieve the high demands on air cleanliness
by minimizing the number of particles and microorganisms in the air.
CleanSeal is available in several standard sizes and different types of connections/configurations.
The filter clamping system is adjustable for different filter depths. This scalability allows an upgrade of existing filter to a deeper filter
with lower pressure drop. Low pressure drop filters can be used either to maintain pressure cascades or to get energy savings.
Thanks to the tool-less filter clamping and unique filter retainer, the handling and maintenance if very easy.
The filter is pre-positioned in the housing which makes it possible to handle by only one person.
The installation of the housing is very easy with supporting blocks.
The hinged diffusor plate gives direct access to the filter and control ports and is opened with just a badge/card.
Consult Camfil office for additional information.

Type Dimensions WxHxD (mm) Duct connection (mm) Filter size HxWxD (mm) Weight (kg)

CL-SW-3P3-P-xx-S-R-000-N-00-AAA0 367x 355x 374 200x 100 305x 305x 8,8

CL-SW-3P6-P-xx-S-R-000-N-LS-AAA0 660x 367x 374 350x 100 305x 610x 12,9

CL-SW-3P6-P-xx-S-R-000-N-SS-AAA0 660x 367x 474 200x 200 305x 610x 14,8

CL-SW-4P4-P-xx-S-R-000-N-00-AAA0 519x 507x 424 350x 150 508x 508x 14,0

CL-SW-5P5-P-xx-S-R-000-N-00-AAA0 570x 558x 424 400x 150 508x 508x 15,7

CL-SW-6P6-P-xx-S-R-000-N-00-AAA0 672x 660x 424 500x 150 610x 610x 19,1

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CL-SW-9P6-P-xx-S-R-000-N-LS-AAA0 965x 672x 474 600x 200 610x 915x 26,4

CL-SW-9P9-P-xx-S-R-000-N-00-AAA0 977x 965x 474 500x 200 915x 915x 33,9

CL-SW-11P5-P-xx-S-R-000-N-SS-AAA0 1158x 570x 474 400x 200 508x 1108x 27,8

CL-SW-11P5-P-xx-S-R-000-N-LS-AAA0 1158x 570x 424 800x 150 508x 1108x 26,0

CL-SW-12P6-P-xx-S-R-000-N-SS-AAA0 1270x 672x 474 500x 200 610x 1220x 32,5

CL-SW-12P6-P-xx-S-R-000-N-LS-AAA0 1270x 672x 424 800x 150 610x 1220x 30,2


The item types in the table are PU versions (for filters with PU gasket). Other sizes and variants on request.
For ordering: To select filter frame hight replace “xx” with “MD” for Megalam MD, “MX” for Megalam MX and “MG” for Megalam MG
SW= Standard version steel white RAL 9010 (Optional S4=Stainless steel SS 304, S6= SS 316L)
P= PU version & G= GEL version

1
Housings and Frames | Information

CleanSeal product overview


Available diffusers

Available configurations

Top entry Rectangular side entry

Side entry with damper Side entry

305 x 305 457 x 457 508 x 508 610 x 610 915 x 915 610 x 305 915 x 610 1108 x 508 610 x 1220

3P3 4P4 5P5 6P6 9P9 6P3 9P6 11P5 12P6


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

392 x 392

544 x 544
595 x 595
697 x 697 697 x 392

1002 x 1002 1002 x 697

1195 x 595
1307 x 697

Available for all gasket types

CleanSeal is available for Camfil filters


with DIN, PU or Gel gaskets.

13
Housings, Frames & Louvres | Terminal Housings

CamHosp 2
Advantages
• New modular design • Conformity to the standard
• More secure assembly NFS-90 351 in areas at risk 3
• Tightness in terms of and 4
immediate and lasting joint

Application: Modular filtration ceiling with a unidirectional flow for


operating theaters design
Comment: Construction: Modular, with each module assembled and
sealed in the factory and consisting of:
1 plenum part made of carbon steel
1 airtight,continuously welded platform with a thickness of 1.5mm
Assembly: The modules are simply bolted together on site. Airtight
joints are created mechanically between the modules
Protection: Oven-baked, RAL 9010 epoxy with primer coating both
inside and out
Test connector: 1 test connector accessible from the operating
theater to measure the loss of pressure and to take Test Aerosol
samples
Fitting the filters: From the operating theaters the filters can be
quickly clamped in place with a compression limiter using captive,
pre-positioned tabs.
Cassing airtight at 450 Pa: Class B of EN 1886:1998, Class L1 (M)
of PR EN 1886:2003, Class C of PR EN 12237:2003
Joints airtight at 450Pa: Maximum local penetration < 10-4 (0.01%)
in accordance with ISO EN14644-3
Finish: 2 types of finish:
Screentek : set of clip-on frame units with screens made of
monofilament polyester fabric
Protek: set of clip on frame units with screens made of perforated
steel sheet

Type Ext.size WxHxD (mm) Int.surface m2 Airflow (m3/h) at 0.25m/s Airflow (m3/h) at 0.3m/s Airflow (m3/h) at 0.45m/s No.of module(s)

Type 1 1913x 1308x 431 1.6 1,760 2,110 3,160 1

Type 1.5 1913x 1909x 449 3.3 2,560 3,080 4,620 2

Type 2 1913x 2516x 449 4.4 3,060 3,670 5,510 2+2

Type 3 2519x 2516x 449 5.9 4,120 4,950 7,420 4+2

Type 3.5 2519x 3126x 449 7.3 5,360 6,430 9,650 4+2

Type 4 3124x 3124x 449 9.2 7,020 8,420 12,630 4

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Type 5p5 filter size AxBxH (mm) Quantity 8p5 filter size AxBxH (mm) Quantity 11p5 filter size AxBxH (mm) Quantity

1 560x 560x 66 0 560x860x66 0 560x1165x66 3

1.5 560x 560x 66 0 560x860x66 6 560x1165x66 0

2 560x 560x 66 2 560x860x66 6 560x1165x66 0

3 560x 560x 66 0 560x860x66 10 560x1165x66 0

3.5 560x 560x 66 0 560x860x66 2 560x1165x66 8

4 560x 560x 66 0 560x860x66 0 560x1165x66 12

13
Containment Systems | Terminal Filter Housings

CAMFFU EC
Advantages
• Individual control • Low power consumption
• EC Fan for high reserve
capacity for pre and AMC
Filtration

Application: Flexible and economical solution to equip cleanroom from ISO 8


to ISO 5
Type: Self contained ceiling fan filter unit with high performance EC motor
Construction: Aluminum, SS430, Galvalume.
Fan: Efficient EC Motor
Airflow control: BUS controlled system or handheld control
Filter : Megalam H13, H14, U15 or U16. MD, MX or MG with dry PU gasket to
be ordered separately.

Simple and reliable operation


High efficiency EC fans are selected for applications where energy consumption
is the utmost importance. The unique built-in controller within the motor allows for
each unit to be individually controlled and monitored remotely upon connection to
an integrated control system.

Camfil can also provide customized solutions to support existing system integration
depending on the type of configuration required. The control system could either be
a common operating system in the market such as eLisa, or Camfil’s CamControl
system. For more details regarding types of central control systems and control
configurations available, please kindly contact Camfil technical specialist.

Tech
hnical Specificat
ation
Typical Grid Size 1200 x 1200 1200 x 600 600 x 600
*Size (L x W) (mm) 1175 x 1175 1175 x 575 575 x 575

Nominal Height without filter (H) (mm) 315 + 35 295 + 30 275 + 25

Nominal Weight without filter (kg) 30.0 - 36.5 16.0 - 26.0 11.0 - 15.0

Noise Level (dBA) 43 - 56 44 - 53 43 - 52

Power consumption (kW) 150 - 183 90 - 110 49 - 60

Housing Material Aluminium / Stainless Steel / Galvalume

Motor Type EC
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Voltage Type 1 Ph, 220V, 50/60 Hz

*Other dimensions are available on request.

PLAN VIEW END VIEW


Containment Systems | Terminal Filter Housings

CAMFFU AC
Advantages
• Individual control • Low power consumption
• AC Fan maintenance free

Application: Flexible and economical solution to equip cleanroom from ISO 8


to ISO 5
Type: Self contained ceiling fan filter unit with AC motor
Construction: Aluminum, SS430, Galvalume.
Fan: Efficient AC Motor
Airflow control: 5 speed manual control
Filter : Megalam H13, H14, U15 or U16. MD, MX or MG with dry PU gasket to
be ordered separately.

Simple and reliable operation


AC fans are provided for customers looking for simple and cost effective solutions.
The speed of the highly stable and reliable fans are manually controlled using a five
speed or variable speed manual controller.

Camfil can also provide customized solutions to support existing system integration
depending on the type of configuration required. The control system could either be
a common operating system in the market such as eLisa, or Camfil’s CamControl
system.

For more details regarding types of central control systems and control configurations
available, please kindly contact Camfil technical specialist.

Tech
T hnical Specificattion
Typical Grid Size 1200 x 1200 1200 x 600 600 x 600
*Size (L x W) (mm) 1175 x 1175 1175 x 575 575 x 575

Nominal Height without filter (H) (mm) 315 + 35 295 + 30 275 + 25

Nominal Weight without filter (kg) 31.0 - 37.5 15.5 - 25.5 10.5 - 14.5

Noise Level (dBA) 49 - 60 42 - 52 48 - 59

Power consumption (kW) 305 - 375 146 - 180 105 - 126

Housing Material Aluminium / Stainless Steel / Galvalume

Motor Type AC
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Voltage Type 1 Ph, 220V, 50/60 Hz

*Other dimensions are available on request.

PLAN VIEW END VIEW


Housings, Frames Louvres | Safety Housings

CamSafe 3 -Housing
Advantages
• Modularity and Flexibility • Filter clamping “Twice the
• High security guarantee: class Security” (patented)
3 IS010648-2 at +/- 6000Pa • High operator protection by
• Fully welded BIBO

Application: Exhaust of contaminated air (particles,


microorganisms, molecules), filter changing in secure plastic bag:
Pharmaceutical, Biotechnology, Chemistry, Hospitals, Laboratories
biosafety, animal facilities.
Type: Housing
Comment: Type: Modular system BIBO safe change housing to be
assembled, fully welded.

Construction: 2mm steel airtight welded.

Finish: White painted baked RAL 9010.

Filter frame: Bended and continuous welded.

For filters: 292mm depth particle and carbon filter, 45mm depth
prefilter.

Filters mounting : Fast filter clamping by ClampSafe, equipped with


a “twice security” both on clamping frame and door: impossible to
clamp the filter if not correctly positioned and impossible to close
the door if the filter is not clamped.

Connection: Rectangular flanges pre-drilled.

Pressure ports: Locations provided upstream and downstream


(pressure port kit to be ordered separately).

Performance: Housing qualified +/- 5000Pa: Class 3 acc. to ISO


10648-2, L1 acc. to EN1886, Class D acc. to EN12237, Class C acc.
to Eurovent 2/ 2.

Accessories: Safe change bag with integrated a-ring sealable,


Gaskets and bolting kit Connecting ducks 1-6 housing in parallel for
high flow rates.

Option: Stainless steel, factory mounting full or partial, individual


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

factory tests with test report.

Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Weight (kg)

4500004C CS3-610-F-SS 730x 535x 725 610x 610x 292 45

4500006C CS3-305-F-SS 730x 535x 420 610x 305x 292 39

4500000C CS3-610-F-PPC 730x 535x 725 610x 610x 292 45

4500002C CS3-305-F-PPC 730x 535x 420 610x 305x 292 39

13
Housings, Frames Louvres | Safety Housings

CleanSeal Extract Exhaust/Return Air Housing


Advantages
• Tool-less filter clamping 100% • High corrosion protection
secured and immediate againts decontamination
• Quick grid locking for agents
immediate access to filter • Ensure localized control of
• Long lasting reliability and potent compounds, eliminating
tightness : robust fully welded the contamination of
construction downstream ductworks
• Easily operation with scanning
system for filter integrity test

Application: CleanSeal Extract is wall mount equipment used


for exhaust/return air system: Pharmaceutical, Biotechnology,
Chemistry, Hospitals, and animal facilities.
Type: Housing
Comment: Type: Fully welded Wall mount housing.

Construction: Carbon steel, fully welded seams, accessories in


Stainless Steel

Finish: 3 Steps - white epoxy coated RAL 9010, qualified for high
corrosion protection against decontamination agents

Filter Seal: Endless PU gasket on filter.

Connection: Rectangular pre-drilled flanges.

Pressure Gauge: Pressure gauge is pre-installed on the equipment.

Performance: The whole equipment could bear ±1000Pa.The overall


leakage rate should no more than 0.25% per hour under 1000Pa
pressure.

Scanning system: Accourding to standard IS014644-3.

Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Unit volume (m3) Weight (kg)

WM10000C CLE-SW-6P6-P-MD-SR6008-N-LS-AOOO 800x 998x 526 HEPA:610x 610x 66 0.6 55

WM10001C CLE-SW-6P6-P-MX-SR6008-N-LS-AOOO 800x 998x 526 HEPA:610x 610x 90 0.6 55

WM10002C CLE-SW-6P6-P-MG-SR6008-N-LS-AOOO 800x 998x 526 HEPA:610x 610x 110 0.6 55

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
WM10003C CLE-SW-6P6-P-48MD-SR6008-N-LS-AOOO 800x 998x 526 Pre-filter 610x 610x48 0.6 55
HEPA : 610x610x66

WM10004C CLE-SW-6P6-P-NF-SR6008-N-LS-AOOO 800x 998x 526 No Filter 0.6 55


*Other model please contact Camfil Kunshan factory.

One-Stage Filter HEPA-Megalam


Dimensions WxHxD Unit Volume Airflow/pressure drop
Art. No. Type Area (m2) EN 779 Weight (kg)
(mm) (m3) (m³/h/Pa)

15042392C Megalam MDA-610x610-01/22 610x 610x 66 9.7 H14 0.02 1000/250 4

15056166C Megalam MXA-610x610-01/22 610x 610x 90 13.2 H14 0.03 1500/250 5.6

15066022C Megalam MGA-610x610-01/22 610x 610x 110 17.5 H14 0.04 1800/250 5.3
.

13
Housings, Frames Louvres | Safety Housings

CamContain CS
Advantages
• Stainless steel housing • Especially secure filter
conforms to tightness-class clamping technology
as required by nuclear power • Innovative filter insertion
stations device
• Integrated filter scanning • Safe decontamination concept
technology

Application: Hospital isolation rooms/wards and Intensive Care Units


(ICUs) for the control of airborne pathogens, viral contaminants and
infectious organisms
Comment: Construction: Matched components can include bag-in/
bag-out section, prefilter section, testing section and an optimized
fan section
Filters: HEPA filters and various grades of prefilters
Additional data: Consult Camfil office for additional information

Safety cannot be stressed enough.


Especially when it involves highly sensitive applications in which people, animals or the environment are endangered by highly infectious
microorganisms, for example. High safety demands apply to all situations in which toxic, radioactive or bacterial substances must be
isolated, such as in the pharmaceutical industry, with the use of biotechnical equipment as well as in BSL-3/BSL-4 laboratories and
nuclear power engineering.
The filter housings have been designed to meet the highest safety demands.

To ensure a complete documentation of your air filtration, most notably in highly sensitive areas, the CamContain CS housing can
be supplied with an integrated scanner. The HEPA filter can be tested on-site for separation efficiency and any leaks, and the results
professionally documented. For applications in which dangerous microorganisms must be filtered out (BSL-3/BSL-4), the housing
can be equipped with connections and devices for safe decontamination. What is more, the maintenance bag replacement technology
guarantees additional safety for the operator. The CamContain CS housings made of stainless steel are gas-tight welded, torsion-
resistant and compliant with the highest tightness requirements, which are also commonly used in nuclear power plant engineering.

The CamScan Mobile is a mobile analysis unit for the automatic testing of an installed filter. As defined in the standard DIN 1822, the
built-in filter can be tested for overall separation efficiency and any possible leaks. The computer that is integrated into the system
stores the measurement values, which in turn allows for trouble-free documentation.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

13
Housings and Frames | Information

CamCube filter housings


Flexible, compact and with multiple stage filtration options

HINGED SERVICE HATCH


with foldable handles ROBUST CONSTRUCTION
Leakage class C, EN15727 HEAT AND CONDENSATION INSULATED
Mechanical performance: 45 mm insulation in a sandwich design
D1, EN1886:2007

ALUZINC
Corrosion class C4

OPTIONAL PREFILTER
MOUNTING RAIL

ADJUSTABLE FEET
Available for floor mounting

CLAMPING DESIGN AC
CLAMPING DESIGN HF

• CamCube HF: For filters with header frame 25 mm, like Hi-Flo, Opakfil, CityCarb and CitySorb.
• CamCube AS: is a housing with integrated scanning system for HEPA filters size 610x610x292 mm

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
• CamCube AD: for HEPA filter size 610x610x292 mm
• CamCube AC: for HEPA filters size 595x595x292 mm
• CamCube CC: For CamCarb cylindrical molecular filters with max depth 450 mm
• CamCube HF-CC: For CamCarb cylindrical molecular filters with max depth 600 mm

THE HOUSINGS CAN BE ORDERED IN A VARIETY OF DIFFERENT SIZES

Size samples

13
Housings, Frames Louvres | Ducted Housings

CamCube HF-L
Advantages
• For bag filters and compact • Leakage class C acc. EN 15727
filters (header frame) • Easy maintenance
• Build-in thermal insulation • Optional rail for prefilter
• Corrosivity class C4 for Aluzinc panels
housing material

Application: CamCube HF is a flexible and compact range of filter


housings for bag filters and other filter types with a 25 mm frame.
Used in comfort and industrial applications
Max Temperature (°C): 70°C
Comment: Filter housing material: Aluzinc
Option: Stainless steel SS EN 1.4301
Filter: Bag filters such as Hi-Flo XL and City-Flo XL. Compact filters
such as Opakfil. See the relevant page in the catalogue for the
technical data about filters
Air flow: The recommended air flow in a full module filter (592 x
592 mm) is 3,400 m3/h. See the relevant page in the catalogue for
further information
Note: Door hinged on the left or right, can be changed on site
Included as standard: Adjustable feet, mounted pressure points, in-
and outlet gasket for guidance connection
Accessories: Lockable handles

CamCube HF is a flexible and compact range of filter housings for bag filters and other filter types with a 25 mm frame. Two stage
filtration is available as an option with a prefilter mounting rail for panel filters. The housing walls is a sandwich design with 45 mm
heat and condensation insulation between, covered with aluzink sheet metal inside and outside (corrosivity class C4).
The service hatch is hinged mounted. The endless gasket on the inside of the service hatch makes it highly airtight.
The filter housing has a leakage class of C according to EN 15727.
When the service hatch is closed the newly developed clamping device ensures the clamping of the filter.
As standard the casing has M8 threads for mounting the filter housing. The filter housing is supplied with a guide connection and a
flange connection is available as an option.

Accessories:
Prefilter mounting rail 50 or 100 mm
Locking handles
Flange adaptor

Example specification text:


Filter housing: CamCube HF-1010. Supplier, Camfil Svenska AB
Design: Sandwich construction with 45 mm heat and condensation insulation,
covered with double aluzinc sheet metal ( corrosivity class C4)
Leakage class C
Filter: 1 x Cityflo XL-592x592x640 F7
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Accessories: One set of adjustable feet. Hose connectors for pressure drop, factory mounted

Classification:
Leakage class C, according to the EN 15727:2010 standard. Leakage class L1 according to the EN 1886:2007 standard
Mechanical perfomance: D1 according to the EN 1886:2007 standard
Filterbypass test, highest class according to the EN 1886:2007 standard, up to filter class F9

Art. No. Type Dimensions WxHxD (mm) Inner flanges W1xH1 (mm) Weight (kg)

550001 CamCube HF-L 0505 392x 392x 700 300x 300 24

550002 CamCube HF-L 0510 392x 692x 700 300x 600 34

550003 CamCube HF-L 1005 692x 392x 700 600x 300 34

550004 CamCube HF-L 1010 692x 692x 700 600x 600 43

550005 CamCube HF-L 1015 692x 992x 700 600x 900 55

550007 CamCube HF-L 1025 692x 1592x 700 600x 1500 76

550006 CamCube HF-L 1020 692x 1292x 700 600x 1200 64

550008 CamCube HF-L 1030 692x 1892x 700 600x 1800 85

550009 CamCube HF-L 1510 992x 692x 700 900x 600 53

550010 CamCube HF-L 1515 992x 992x 700 900x 900 66

550011 CamCube HF-L 1520 992x 1292x 700 900x 1200 76

550012 CamCube HF-L 1525 992x 1592x 700 900x 1500 89

550013 CamCube HF-L 1530 992x 1892x 700 900x 1800 99

550014 CamCube HF-L 2010 1292x 692x 700 1200x 600 62

550015 CamCube HF-L 2015 1292x 992x 700 1200x 900 77

13
Housings, Frames Louvres | Ducted Housings

Art. No. Type Dimensions WxHxD (mm) Inner flanges W1xH1 (mm) Weight (kg)

550016 CamCube HF-L 2020 1292x 1292x 700 1200x 1200 86

550017 CamCube HF-L 2025 1292x 1592x 700 1200x 1500 100

550018 CamCube HF-L 2030 1292x 1892x 700 1200x 1800 109

550019 CamCube HF-L 2510 1592x 692x 700 1500x 600 74

550020 CamCube HF-L 2515 1592x 992x 700 1500x 900 89

550021 CamCube HF-L 2520 1592x 1292x 700 1500x 1200 98

550022 CamCube HF-L 2525 1592x 1592x 700 1500x 1500 113

550023 CamCube HF-L 2530 1592x 1892x 700 1500x 1800 123

550024 CamCube HF-L 3010 1892x 692x 700 1800x 600 83

550025 CamCube HF-L 3015 1892x 992x 700 1800x 900 99

550026 CamCube HF-L 3020 1892x 1292x 700 1800x 1200 108

550027 CamCube HF-L 3025 1892x 1592x 700 1800x 1500 124

550028 CamCube HF-L 3030 1892x 1892x 700 1800x 1800 134

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

13
Housings, Frames Louvres | Ducted Housings

CamCube AS
Advantages
• For Compact filters (box type) • Advanced patended probe for
full size 610x610x292mm reliable scanning
• Unique non-intrusive patented • Built-in inspection lens and
scanning system light
• Space saving installation • Leak-free guarantee
• Built-in thermal insulation

Application: Filter housing with integrated scanning system


Max Temperature (°C): 90°C
Comment: Filter: High airflow HEPA filter, in size 610x610x292 mm.
See the relevant page in the catalogue for the technical data about
filters
Filter clamping: Suitable for filters, in depth 292 mm. Tool for filter
clamping hex key 5 mm
Note: The housing is reversible depending on airflow direction
Material: Aluzinc

CamCube AS is a flexible and compact range of scannable filter housings for high airflow HEPA filters and other filter types with 292
mm depth. The cover is a sandwich design with 45 mm heat and condensation insulation between, covered with Aluzinc sheet metal
inside and outside (corrosivity class C4). The groove around and between the filters is sealed with sealant to exclude any leakage from
the joints.
The service hatch is hinged mounted. The endless gasket on the inside of the service hatch ensures high tightness.
The filter housing has leakage class D according to EN 15727.
When the service hatch is closed the clamping device ensures the clamping of the filter.
The filter housing is supplied with flange connection and hose connectors for pressure drop measurement.

Accessories:
Replacement kit for scanning system
Lockable handles

Scanning:
Using the integrated crank, with foldable handle, the scanning probe can be moved up and down. The scanning process is non-intrusive,
easy, reliable and secure and installation footprint is minimized.
The built-in wide angel inspection lens and light makes it easy to look inside the housing.
The scanning system is easy to replace if needed.

Example specification text:


Filterhousing: Camfil CamCube AS-1010.
Design: Sandwich construction with 45 mm heat and condensation insulation,
covered with double aluzinc sheet metal (corrosivity class C4).
Including hinged airtight hatch for fast access.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Filter: Absolute DG 610x610x292 mm.


Integrity test for validation operation : Built-in, non intrusive scanning system for HEPA filter integrity test, including 100%
concentration measurement ports.
Clamping system: Designed not to disturb integrity test operations.
Inspection: Built-in inspection lens and light to survey while performing scanning.

Classification:
Leakage class D according to EN 15727:2010 standard.
Leakage class L1 according to EN 1886:2007 standard.
Mechanical: D1 according to EN 1886:2007 standard.
Max penetration gasket frame (filter section) < 0,01% by ISO 14644-3.
Fulfills the regulatory demands on HEPA-filter integrity test according to ISO 14644-3.

Art. No. Type Dimensions WxHxD (mm) Duct connection (mm) Weight (kg)

553004 CamCube AS-1010 707x 707x 650 615x 615 43

553006 CamCube AS-1020 707x 1322x 650 615x 1230 64

553008 CamCube AS-1030 707x 1937x 650 615x 1845 85

553014 CamCube AS-2010 1322x 707x 650 1230x 615 62

553016 CamCube AS-2020 1322x 1322x 650 1230x 1230 86

553018 CamCube AS-2030 1322x 1937x 650 1230x 1845 109

1
Housings, Frames Louvres | Ducted Housings

D W

H
1010 1020 1030 2010 2020 2030

1 2 3

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1.Advanced patended probe


2. Optical wide angle inspection lens
3. Crank with foldable handle

14
Housings, Frames Louvres | Filter Holding Frames

Absolute Filter Holding Frame


Advantages
• Modular design adaptable for • Pre drilled for easy assembly
all types of installations • Filter holding clips can be
• Location dimples in frame easily replaced as required
ensure correct filter fitting

Application: Mounting very high efficiency filters in air conditioning


units and systems
Frame: Stainless steel, Galvanised steel
Comment: Filter types: HEPA filters like Absolute or other compact
filters (box type)
Filter fixing: Using 4 corner mounted clamps

Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Weight (kg)

5107.06.01 Galvanised steel 626x 626x 335 610x 610x 292 12,5

5107.24.01 Galvanised steel 626x 321x 335 305x 610x 292 10

5107.50.01 Galvanised steel 610x 305x 335 290x 595x 292 9,9

5107.60.01 Galvanised steel 610x 610x 335 595x 595x 292 12,3

5107.50.02 Stainless steel 610x 305x 335 290x 595x 292 9,9

5107.60.02 Stainless steel 610x 610x 335 595x 595x 292 12,3

5107.24.02 Stainless steel 626x 321x 335 305x 610x 292 10

5107.06.02 Stainless steel 626x 626x 335 610x 610x 292 12,5
Other dimensions and arrangements available on request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

14
Housings, Frames Louvres | Filter Holding Frames

Universal filter holding frame


Advantages
• Rapid installation of the frame • Holds a variety of bag filters
and compact filters (with
header frame)

Application: Suitable for commercial and industrial applications


Frame: Stainless steel, Galvanised steel
Comment: Gasket: Optional endless polyurethane gasket
Remarks: Filter fixing using 4 clamps (included)
Mounting frame for Hi-Flo, Opakfil and other bag- and compact (hf)
filters
Stainless Steel

Frame
Art. No. Type Dimensions WxHxD (mm) Clips included Weight (kg)

4300001 Frame 4SPXM 608x 608x 76 Yes 3

4300003 Frame 4URZO 303x 608x 76 Yes 2.2

430F-4300104 Type 8 Holding Frame 24x12” 303x 608x 68 No 2.2

430F-4300101 Type 8 Holding Frame 24x24” 608x 608x 68 No 3


Clamping height 25 or 50 mm

Clips

Art. No. Type Model

6999-10001 Clip C70

6999-10002 Clip C78-3

6999-10003 Clip C78-4

6999-10004 Clip C78-5

Recommended clips for Type 8 frame


Prefilter. Secondary filter Recommended clip Number of clips required

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
1* None C70 4

2* None C70 4

4* None C78-4 4

None With 25 or 20mm header C70 4

1* With 25 or 20mm header C70 4

2* With 25 or 20mm header C78-3 4

4* With 25 or 20mm header C78-5 4


Clamping height 25 or 50 mm

14
Housings, Frames Louvres | Filter Holding Frames

FastFrame
Advantages
• No clamp manipulation • Holds a variety of bag filters,
optimizes filter change out compact filters (with header
times frame) , prefilters or a
• Rapid installation of the frame combination thereof
• Modular concept for all
installations

Application: Mounting frame for Hi-Flo, Opakfil, EcoPleat and other


bag- and compact filters
Frame: Galvanised steel
Comment: Option: Stainless steel
Gasket: Hygienic endless polyurethane
Filter Types: Pre-filters and header frame type filters.
Filter fixing: Using 4 corner mounted clips, to suit the installed filter.
Also available in stainless steel 304 and 430

Art. No. Type Dimensions WxHxD (mm) Filter size HxWxD (mm) Weight (kg)

4304004 FastFrame with PU gasket 610x 610x 91 592x 592x 3.5

4304003 FastFrame with PU gasket 508x 508x 91 490x 490x 3

4304002 FastFrame with PU gasket 610x 508x 91 490x 592x 3.3

4304001 FastFrame with PU gasket 610x 305x 91 287x 592x 2.8

4304008 FastFrame without PU gasket 610x 610x 91 592x 592x 3.5

4304007 FastFrame without PU gasket 508x 508x 91 490x 490x 3

4304006 FastFrame without PU gasket 610x 508x 91 490x 592x 3.3

4304005 FastFrame without PU gasket 610x 305x 91 287x 592x 2.8


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1
Housings, Frames Louvres | Weather Louvres

CamVane 100
Advantages
• Effective rain separator • Designed for tough conditions
• Specially designed profiles for • Wide range of dimensions
high separation efficiency

Application: Turbomachinery Systems such as gas turbines, large


industrial air compressors, diesel & gas engines, generators

The air intake which is very efficient as rain protection can be used in
all filter installations where water, rain, or fog conditions occur. Also
suitable in marine environments and coastal areas.
Installation Options:
Mounting flange or fastening ears to customer specifications.
Comment: Product Features:
CamVane has specially designed aluminum profiles which ensures
high separation efficiency
Frame material: Aluminum EN-AW-5754
Profiles material: Aluminum EN-AW-6060
Dimensions (WxH): From 250x250 mm to 2500 x 2500 mm, depth
MagiCAD
®

100 mm
Air velocity: 1.0 - 5.0 m/s in the duct system.
When ordered in stainless version: Frame: Stainless AISI316L,
Profiles: Aluminum EN-AW-6060
Tested according to EN 13030:2001: Class A
Options: Mounting flange, drain type, painted

The CamVane 100 has specially designed profiles where the air is forced into turbulence. Because of inertia, the water droplets are
caught up in the vertical profiles while the air stream continue in the inlet. With gravity, the collected water is directed to the bottom
drainage system and removed.
One or more drains, depending on the size of the frame, are placed on the bottom. The frame is provided with drilled or undrilled flange
on air entering or outlet side.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

14
Housings, Frames Louvres | Weather Louvres

Dynavane
Advantages
• Much higher efficiency as • Constant pressure drop, self-
compared to sand trap louvres cleaning
• Much higher life for pre and • Modular concept and can be
bag filters resulting ROI designed to fit in available
approximately in a year area based upon the designed
• Tested as per ISO 5011 and airflow
efficiency of 95% Coarse dust
and 78% fine dust

Application: Self-cleaning inertial filter designed to handle large


volume of air. Dynavane incorporates inertial separation providing
high dust removal efficiency of airborne particulate matter.
Type: Metal Panel
Frame: Stainless steel, Metal
Installation Options: Construction: 11 gauge steel all welded
construction, bolt on flange for HVAC system connection and bleed
outlet,removable blade pack and four mesh inlet screens. Material of
construction can be Mild Steel, SS304 & SS316
Comment: Face Air Velocity: 2.5 m/s – 4.5 m/s.

Efficiency
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Airflow Resistance

14
Air Cleaners & Air Purifiers

Products

City Air Purifiers City Air Purifiers Industrial Air Cleaners Industrial Air Cleaners
City M City Touch CC 410 (Concealed) CC 1000
Page 150 Page 151 Page 152 Page 153

Industrial Air Cleaners Industrial Air Cleaners Industrial Air Cleaners


CC 1700 CC 2100 CC 6000
Page 154 Page 156 Page 157

As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

14
Air Cleaners & Air Purifiers | Information

City M Overview

CLEAN AIR IN ALL DIRECTIONS


The polluted air passes through the pattern
rn
de
of holes on both sides and continues inside
to be purified.
HEPA filter
CITY air purifier is equipped with a highly ef-
ficient HEPA filter. It removes 99.995 % of alllll
particles down to the MPPS (most penetrating
ng
g POLLUTED A I R
particle size) according to EN1822 standard.

es
The molecular filter efficiently eliminates Molecular filter
odours and gases.

Clean air – free of particles and harmful pol-


ol-
lutants, gases or odours – is dispersed in all
directions, 360°.

Fan

QUICK AND SIMPLE FILTER CHANGES


To change the filters only takes a minute. IR
NA
CLEA
• Remove the top lid and the lid
underneath.
• Take out the used filters and replace
them with new ones.
• And put the lids back in place.
• Also, remember to turn the machine
off during this procedure.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

14
Air Cleaners & Air Purifiers | Information

City M Overview

Technical information

EXTERNAL DIMENSIONS, VERTICAL MODEL


City M
Height (mm) 720
Width (mm) 340
Depth (mm) 345
Weight (kg) 15.0 (including new filters)
Filter weight (kg) 2.0 kg (2 filters are needed)

FAN SPECIFICATIONS
Phase 1~
Nominal voltage VAC 230
Nominal voltage range VAC 200 .. 240
Frequency Hz 50/60
Type of data definition ml
Speed min~1 3200
Power input W 83
Current draw A 0.75
Min. ambient temperature ºC -25
Max. ambient temperature ºC +60

AIR FLOW
City M
Step Qv N Pe LpA
[m3/h] [rpm] [W] [dBA]
1 37 520 4 15.5
2 67 728 5 15.5
3 94 907 6 15.5
4 127 1072 7 21.7
5 251 1772 19 37.7

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
6 Max. 433 2733 55 52.6

City M - front City M - side City M - back

14
Air Purifiers | City Air Purifiers

City M
Advantages
• Individually certified H14 • Removal of airborne
filters ensuring 99.995% particulates, viruses, and
filtration efficiency bacteria
• Ideal for larger rooms in offices • Protecting the health of your
and hospitals employees

Application: Air purifier for all types of indoor environments,


for example hospitals, hotels, offices, homes, schools, public
environments and where high quality air purification is required
Power supply: 200...240V
Comment: Filter: H14/Molecular (H13 is available as an option)
Installation: Floor
Design: White
Average Air purification area: 75m²

Art. No. Type Dimensions WxHxD (mm) Weight (kg)

94000047 Air purifier CITY M (WHITE) 340x 720x 345 15

56160011 B Replacement Main filter*

56160027 B Replacement Main filter*

94020031 Replacement Pre filter**

94000199 Air Image Sensor 144x 64x 61 0.2


*Includes 2pcs H14/Molecular
**Includes 2pcs PPI mat
94000047 - Transport Dimension (mm)/Weight (kg): 395x790x395 / 17

Operating Specification
Setting. Air flow (m3/h) Energy Consumption (W) Noise Level (dBa)* Max Filtration Efficiency (%)

1 37 4 16 >99.99

2 67 5 21 >99.99

3 94 6 28 >99.99

4 127 7 35 >99.99

5 251 19 45 >99.99
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

6 433 55 54 >99.99
*Tolerance +/- 10%

Accessory

Air Image Sensor (94000199)


• Monitors and tracks air quality
• Controls indoor air quality
• Energy savings through smart connectivity
• World map IAQ levels

1
Air Purifiers | City Air Purifiers

City Touch
Advantages
• Healthier Indoor Environment • Reduce PM1 and PM2.5
• Reduce Environmental Impact • Less Odour
• Less Asthma and Allergy • Low power consumption
Suffering

Application: Air purifier for all types of indoor environments,


for example hospitals, hotels, offices, homes, schools, public
environments and where high quality air purification is required
Installation Options: Floor, Filter Replacement Reminder, Child Lock
Comment: Power Supply: AC 220V/50HZ
Filter: Pre Filter, Molecular Filter, EPA Filter
Particle Clean Air Delivery Rate (CADR): 500m3/h

Cleaning Energy Efficiency: High efficiency class (GB 18801.2015)


Timer:2,4,8,10,12h

Sensor: Particle + VOC


Model: Quick,Sleep,Auto
Remote Control

Art. No. Type Dimensions WxHxD (mm) Weight (kg)

94000152 City Touch (White) 340x 496x 388 8.2

Pre Filter

EPA Filter

VOC Filter
Filter included in standard version EPA 11 Filter+VOC Filter+Pre Filter
Available in selected market only

Operating Specification
Setting. Air flow (m3/h) Energy Consumption (W) Noise Level (dBa)* Max Filtration Efficiency (%)

TURBO 500 40 66 99%@0.3μm, 99% @ PM1 and PM2.5

Exchange

Article Number Type Number of filters per air purifier Specification

9119139 Pre Filter 2 Nylon

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
CITF003C EPA Filter 2 Particle Filter

CITC02 VOC Filter 2 VOC Filter

15
Air Cleaners | Industrial Air Cleaners

CC 410 (Concealed)
Advantages
• Healthier employees • Clean products, fewer
• Less cleaning operational disruptions
• Lower energy costs • Easy to adapt ducts and
• Reduced environmental impact diffusors
• Less odour

Application: Air purifier for rooms measuring up to 140 m², for


example small or medium offices.
Power supply: 200...240V
Type: Air cleaner
Frame: Steel, painted
Installation Options: Wall or ceiling (built in)
Comment: Frequency: 50/60hz
Duct Connection: 2 pc Ø250mm
Capacity: 0~490 m³/h, Air Flow controlled by potentiometer with
cable (5m)
Air Image: Optional
Design: Powder coated sheet steel (White)
Air purification area: MAX 140 m²

Art. No. Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Power Consumption (W) Weight (kg)

94000159 Air Cleaner 410 (Concealed) - M 1052x 300x 364 480/ 165 31.5

94000160 Air Cleaner 410 (Concealed) 1052x 300x 364 490/ 165 25

94000159A Air Cleaner 410 (Concealed) - M 1052x 300x 364 480/ 165 31.5

94000160A Air Cleaner 410 (Concealed) 1052x 300x 364 490/ 165 25
Filter included in standard version
94000159 - ISO ePM10 50%
* Molecular and HEPA filter not included
94000160 - ISO ePM1 60% (bag filter)
*HEPA filter not included
94000159A - ISO ePM10 50%
* Molecular and HEPA filter not included
94000160A - ISO ePM1 60% (bag filter)
*HEPA filter not included

Operating Specification
Setting. Air Flow m3/h Noise level dB Power Consumption (W) System efficiency based on H14)

1 45 23.0 2.5 >99 %

2 124 28.1 8.3 >99 %

3 271 44.7 37.9 >99 %


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

4 412 55.3 101 >99 %

5 442 58.9 155 >99 %

6 490 63.3 165 >99 %

15
Air Cleaners | Industrial Air Cleaners

CC 1000
Advantages
• Healthier employees • Eliminates tobacco smoke,
• Less asthma and allergy odour PM1, PM2.5 and
suffering ultrafine particles
• Reduced environmental impact
• Lower power consumption

Application: Air cleaner to provide clean air for all kinds of indoor
environments e.g. office, healthcare, pharmaceutical, food and
beverage, schools, gym, bakeries, processing industry, supermarkets,
etc. Specialized for the elimination of VOCs, H2O2, ozone, smoke,
bacteria and ultrafine particulate matters.
Power supply: 200...240V
Installation Options: Mobile, stationary, wall-mounted, ceiling-
mounted, or ducted.
Comment: Filter: 3 stages filter (Pre filter, Molecular & HEPA 13)
Capacity: Max 1000 m3/h
Energy consumption: 420W max
Average air purification area: up to 200m²
Air Quality Monitor: PM sensor (built-in) or Air image
Castor Wheel: Non-marking PU Castor (suitable for hospital and
cleanroom)
System Control: Air Flow Sensor, Pressure Sensor, 24x7 on/off Timer

Art. No. Type Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Power Consumption (W) Area (m²) Weight (kg)

94000181 CC 1000 630x 1282x 505 max 1000/ 420 up to 200 88

CC1000 Maximum Pressure Drop


versus Air Flow
1000
950
Pressure Drop (Pa)

900
850
800
750
700
650
600
550
0 200 400 600 800 1000

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Air Flow (CMH)

HMI Touch Screen High Performance Fan Motor All around Acoustic Insulation

Secure and Easy Filter Change using Active Clamp System (ACS)

15
Air Cleaners | Industrial Air Cleaners

CC 1700
Advantages
• High efficient HEPA and • Pressure drop alarm
molecular filtration options • Silent performance
• Easy to service • On/Off timer
• Touch Screen control • Constant Air flow features

Application: Versatile Air Cleaner specialized for elimination of


acids, corrosive gases, VOC’s, ozone, formaldehyde and particulate
matter. Inside, you will find the well-known CamCarb, City or
Gigapleat molecular products and EN, ASHRAE or ISO certified
Particle filters. Due to Camfil’s in house HEPA / Molecular filter
expertise, we provide several unique customer benefits, such as low
pressure drop and energy consumption, unique media combinations
and optimized product lifetime. This air cleaner is engineered for
multiple segment customization and often used in the following
areas: Control rooms of petrochemical facilities, metal refining and
pulp & paper mills; data centres & switch rooms, IVF Clinique’s,
health care facilities, indoor air quality excellence in polluted cities,
cleanroom upgrades or complement to existing cleanrooms. Taking
into account filter replacement, service cost, downtime and electrical
power requirements, this product provides a minimum LCC value
Power supply: 200...240V
Comment: Filter: Up to 4 stage filter option
Capacity: Max 1700 m3/h

Art. No. Type Dimensions WxHxD (mm) Airflow (m³/h) Power Consumption (W) Area (m²) Weight (kg)

94000085 CC 1700 1000x 2100x 550 1700 249 150-300 310*


*Weight including filter
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

15
Air Cleaners & Air Purifiers | Information

CC 1700 Overview
Versatile air cleaner specially engineered to provide clean indoor air. Especially
suitable for these professional segments: Corrosion control, healthcare, comfort,
ce, food & beverage.
life science,
COMFORT
VERSATILE FILTER FORMALDEHYDE
COMBINATIONS

CORROSION
CONTROL

Ai
Air Cl
Cleaner CC 1700
Art. number: 94000085

Upgrades/Accessories/Exchange
OIL & GAS, METAL, PULP AND PAPER (CC 1700) FOR CORROSION CONTROL
• Art. no. 94020065 - Inlet, filter class G4, target containment: PM10, 1 pc per unit
• Art. no. 94020068 - CC CG MS, target containment: Acids, H2S, SO2, 15 pcs per unit
• Art. no. 94020074 - CC CG MCI, target containment: Inorganic & organic acids, ozone, 15 pcs per unit
• Art. no. 94020067 - Outlet, filter class E11, target containment: PM2.5, PM1, nanoparticles, 1 pc per unit

DATA CENTERS (CC 1700)

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
• Art. no. 94020066 - Inlet, filter class F7, target containment: PM10, PM2.5, PM1, 1 pc per unit
• Art. no. 94020063 - GigaPleat NXPC MA, target containment: Acids, H2S, SO2, ozone, 1 pc per unit
• Art. no. 94020067 - Outlet, filter class E11, target containment: PM1, nanoparticles, 1 pc per unit
• Art. no. 94020064 - Outlet, filter class H13, target containment: PM1, nanoparticles, 1 pc per unit (upgrade from E11)

COMFORT (CC 1700) FORMALDEHYDE


• Art. no. 94020066 - Inlet, filter class F7, target containment: PM10, PM2.5, PM1, 1 pc per unit
• Art. no. 94020075 - CC CG formaldehyde, target containment: Formaldehyde, aldehydes, 15 pcs per unit
• Art. no. 94020062 - CitySorb VOC, target containment: VOC, smells, 1 pc per unit
• Art. no. 94020021 - CC CG VOC, target containment: VOC, smells, 15 pcs per unit (upgrade from CitySorb)
• Art. no. 94020067 - Outlet, filter class E11, target containment: PM1, nanoparticles, 1 pc per unit
• Art. no. 94020061 - CityCarb, target containment: PM2.5, PM1, VOC, smells, 1 pc per unit

15
Air Cleaners | Industrial Air Cleaners

CC 2100
Advantages
• Healthier employees • Reduced environmental impact
• Less Cleaning • Clean products,fewer
• Eliminates tobacco smoke,weld operational disruptions
smoke,construction • Lower energy costs
dust,asbestos and particles of
all sizes down to ultrafine

Application: Air Cleaner for dusty environments and indoor


premises such as offices, pharmaceutical facilities, food factories,
hospitals and health care, paper mills, bouldering gym, timber
facilities, bakeries, packaging production, printing facilities, stables,
processing industry and supermarkets. Specialized for elimination of
VOCs, Ozone, Formaldehyde and Particulate matter.
Type: Air cleaner
Installation Options: Mobile, stationary, on wall or floor
Comment: Filter: Up to 4 stages filter option
Capacity; max 2100 m3/h
Voltage Usage : 220-240V, 50/60Hz
Energy Consumption: 0.88 KW
Average Air Purification Area: up to 400 m2
Other Option: PM1 sensor, Air image compatibility

Art. No. Type Dimensions WxHxD (mm) Airflow (m³/h) Power Consumption (W) Area (m²) Weight (kg)

94000121 CC 2100 850x 1860x 550 max 2100 880 up to 400 280*
*Weight including filter
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

15
Air Cleaners | Industrial Air Cleaners

CC 6000
Advantages
• Saving energy cost in large • Designed for high airflow
spaces. requirements
• Dual Air Intake • Protecting your people,
• Adaptable filter configurations products and process

Application: Air purifier for dusty environments and large indoor


premises such pharmaceutical facilities, food factories, heavy
industry, paper mills, welding workshops, timber facilities, bakeries,
packaging production, printing facilities, stables, processing
industry, supermarket and other specialist applications such as
upgrading of clean room environments and other classified assembly
environments
Installation Options: Mobile or stationary, floor, wall or ceiling
mounting (with wire or suspension arms)
Comment: Power supply: 3-phase 380-480V or 1-phase 230V
Filter: F7, E11-H13
Fan: EC fan with adjustable airflow and ModBus connection
Capacity: 0 - 6000 m³/h
Connection: 4 standard round (diameter 315mm) or 2 standard
round (diameter 315mm) and 2 round (diameter 250mm) with
sound reduction

Art. No. Type EN779 EN1822 Dimensions WxHxD (mm) Sound level (dB) Power Consumption (W) Weight (kg) Air Volume (m³/h)

94000001 CC 6000 230V, 1 phase Vertical F7 E11 798x 1968x 820 0-67 887 130 6000

94000002 CC 6000 380-400V, 3 phase Vertical F7 E11 798x 1968x 820 0-67 887 130 6000

94000003 CC 6000 230V, 1 phase Horizontal F7 E11 1262x 1359x 829 0-67 887 130 6000

94000004 CC 6000 380-400V, 3 phase Horizontal F7 E11 1262x 1359x 829 0-67 887 130 6000
Uses 4 Pre + 2 main filters

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

15
Air Cleaners & Air Purifiers | Information

CC 6000 Overview
Air Cleaner CC 6000 is engineered to help large logistic and manufacturing
companies keep employees healthy, improve product quality and reduce dust.

Air Cleaner CC 6000 Air Cleaner CC 6000 Air Cleaner CC 6000


Vertical Horizontal Prosafe
Art. number: 94000001 / Art. number: 94000003 / Art. number: 94020005
94000002 94000004

Upgrades/Accessories/Exchange
UPGRADES
• Art. no. 94000005 - Silencer (only for vertical model), 1-2 pcs per unit
• Art. no. 94000006 - Eyelets for ceiling mounting (horizontal), 4 pcs per unit
• Art. no. 94000008 - Upgrade pre-filter to 97mm Ecopleat
• Art. no. 94000010 - Ext. frame for Bagfilter/Citycarb/City-Flo 592x592x max 370 (without filter)
• Art. no. 94000035 - Molecular box for 2x32 pcs CamCarb CG 1300 incl. 2 frames (without filter), 2 pcs per unit
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

ACCESSORIES
• Art. no. 94000007 - Constant airflow sensor, 1 pc per unit
• Art. no. 94000015 - UK Plug (1 phase), 1 pc per unit
• Art. no. 94000016 - UK Plug (3 phase)
• Art. no. 94000026 - Extension frame kit 97mm incl. 2 frames (without filter), 2 pcs per unit
• Art. no. 94000027 - Extension frame bag filter incl. 2 frames (without filter), 2 pcs per unit

EXCHANGE - PRE-FILTER
• Art. no. 94020013 - 3GPA-F7-610x610x48, filter class F7, 4 pcs per unit, standard
• Art. no. 94020016 - Bagfilter XLT F7 592x592x370, filter class F7, 4 pcs per unit
• Art. no. 94020015 - 3GPA-F7-610x610x96, filter class F7, 4 pcs per unit
• Art. no. 94020058 - Aluminium pre-filter with flange 588x1198x50, 2 pcs per unit

EXCHANGE - COMBINATIONS FILTER


• Art. no. 94020018 - CityCarb CIZP-7l 592x592x292, filter class F7, 4 pcs per unit
Art. no. 94020013
• Art. no. 94020017 - City-Flo HFZS-F7 592x592x380, filter class F7, 4 pcs per unit

15
Air Cleaners & Air Purifiers | Information

CC 6000 Overview (continued)

Upgrades/Accessories/Exchange
EXCHANGE - HIGH EFFICIENCY
• Art. no. 94020039 - MGE13-1220x610x100, filter class H13, 2 pcs per unit

EXCHANGE - HIGH MOLECULAR


• Art. no. 94020047 - CamCarb CG 1300 VOC, 2x32 pcs per unit
• Art. no. 94020050 - CamCarb CG 1300 formaldehyde, 2x32 pcs per unit
• Art. no. 94020053 - CamCarb CG 1300 decontamination, 2x32 pcs per unit

EXCHANGE - PROSAFE FILTER


• Art. no. 94020011 - Prosafe pre-filter 610x610x48, filter class F7, 4 pcs per unit
• Art. no. 94020030 - Prosafe 610x1220x100, filter class H14, 2 pcs per unit

EXCHANGE - PROSAFE FILTER


• Art. no. 94000091 - Machine, Air Image sensor
• Art. no. 94000095 - Connectivity upgrade CC6000/CC6000 ProSafe

AIR IMAGE SENS


SENSOR
NSOR

SILENCER (ONLY FOR VERTICAL


MODEL), 1-2 PCS PER UNIT EXT. FRAME FOR BAGFILTER/
CITYCARB/CITY-FLO 592X592X
MAX 370 (WITHOUT FILTER)
CONNECTIVITY UPGRADE

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

UPGRADE PRE-FILTER TO EYELETS FOR CEILING MOUNTING


97MM ECOPLEAT (HORIZONTAL), MOLECULAR BOX FOR 2X32 PCS
4 PCS PER UNIT CAMCARB CG 1300 INCL. 2 FRAMES
(WITHOUT FILTER), 2 PCS PER UNIT

Energy Noise level without Noise level with Working


Air flow W System efficiency
consumption area
(m³/h) (m /h)
3
silencer (dBA) silencer (dBA) according to EN 1822
(W) (m2)
3000 150 0,05 52 50 750 >99 %

4000 312 0,08 56 53 1000 >99 %

5000 556 0,11 62 57 1250 >99 %

6000 887 0,15 67 64 1500 >99 %

15
Turbomachinery Filters

Products

Panel Filters Panel Filters Panel Filters Bag Filters


30/30 GT CamClose CamClose Compact Cam-Flo GT Hybrid
Page 163 Page 164 Page 165 Page 166

Bag Filters Bag Filters Compact Filters (Header Compact Filters (Header
CamGuard Hi-Cap GT Frame) Frame)
Page 167 Page 168 CamPGT CamGT 4V-300
Page 169 Page 170

Compact Filters Compact Filters Compact Filters (Box Type)


(Header Frame) (Header Frame) CamGT Box Type G II Cartridge Filters
CamGT 3V-440 CamGT 3V-600 Page 173 TurboPulse GTC10
Page 171 Page 172 Page 174
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

Cartridge Filters
CamPulse GTC Cartridge Filters Cartridge Filters Cartridge Filters
Page 175 CamPulse GT Polytech HE Tenkay Composite Filters Polytech Nano
Page 176 Page 177 Page 178

Cartridge Filters
Cartridge Filters
Composite Filters GTC (LM6000
CamPulse CamBrane
Series)
Page 180
Page 179

1
Turbomachinery Filters | Information

TurboBoost performance & The Value Rating for gas turbines


Boost power, uptime and profits The Value Rating for gas turbines
CamGT filters are engineered to excel in extreme environments “The easiest way to select filters for gas
where your turbomachinery are threatened by high humidity,
salt-laden air and heavy pollution or particulates. They are turbines”
optimized for EPA efficiency and hydrophobicity to virtually The filters you select to protect your gas turbines can have
eliminate fouling, corrosion and maintenance downtime, all at a a huge impact on your operations. Low efficiency filters lead
lower and stable pressure drop. to fouling and higher pressure drop that rob your turbines of
energy output and cause an increase in fuel consumption and
The CamGT line is the best-performing EPA filters on the CO2 emissions. Powered by Camfil, The Value Rating helps
market: gas turbine users easily evaluate the efficiency and quality
of gas turbine final filters. Armed with this data, you can
quickly compare the impact different filters will have on the
• Improved fuel efficiency
performance of your turbines.
• Higher power output
• Reduced maintenance requirements
• Extended component life The OUTPUT RATING is a projection of the average yearly power
• Increased reliability output you can expect from your turbines as they will have
• Reduced carbon emissions degraded due to filter pressure drop, as well as fouling caused
• Safer operations by particles getting past the filters.

Learn more about the CamGT filters at www.camfil.com/ The FUEL PENALTY value indicates how much more fuel you
TurboBoost and check out the new filter Value Rating Label to must use to compensate for degradation due to fouling and
get a good correlation to the actual impact on your turbine, and pressure drop.
compare!

The CO2 SAVINGS index compares how many tonnes of CO2


you could save per TWh of produced power against an M6 (ISO
ePM10) 60% filter – a basic, industry-standard entry-level final
filter.

Calculate your filter rating at www.TheValueRating.com.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Turbomachinery Filters | Information

PowerEye & BoostToReduce


PowerEye BoostToReduce
“Predictive analytics service for air intake “Upgrade GT Filtration to slash CO2
filters and gas turbines” emission per MWh produced”
PowerEye is an advanced predictive analytics engine. It helps With rising operational costs and a growing demand for greener
your company understand the impact that environmental practices, it has become imperative for gas turbine operators
conditions, changing weather patterns, and filter service status to cut their carbon footprints, reduce operational costs, and
have on the health and performance of your gas turbines. become more efficient.

Filter management Air inlet filters are the easiest, most cost-effective way to
dramatically reduce carbon emissions across your entire gas
Your maintenance teams will be able to monitor pressure drop
turbine operation.
trends and plan the timing of filter change-outs to coincide
with scheduled outages. You save money on logistics and
maintenance costs and – most importantly – avoid lost revenue When you use more efficient air intake filters, you could slash
from unplanned outages. And before you make any filter your CO2 emissions by more than 5% per year, per megawatt
investment, PowerEye can provide hyper-accurate predictive hour produced.
models and life cycle costs analyses that show how different
filter configurations and water wash schedules6 will impact your Visit our website to learn more and calculate your carbon
facilities’ performance and your budget. savings with our online calculators at www.BoostToReduce.com.

Fleet asset maintenance and management

Your gas turbine fleet is spread across many locations


with different weather and environmental conditions. Each
environmental condition has a different impact on the
performance of the intake filters and the engines. PowerEye
gives you the vision to see which locations and assets are
underperforming so that you can allocate resources and take
action where it will have the most impact.

Power output predictions

PowerEye enables your facilities to predict future power output


with a high degree of accuracy. Your company can make
commitments and deliver power to the grid with confidence, so
you meet your contractual obligations and avoid the penalties
of underdelivering.

Visit www.camfil.com/PowerEye
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Panel Filters

30/30 GT
Advantages
• High mechanical strength • Unique radial pleat design
• Rigid, reinforced water • Bonded into case to eliminate
resistant cardboard frame air bypass
• Large media surface • Compact

Application: Suitable for most areas


Frame: Water resistant cardboard
Media: Cotton/Synthetic
Rec. final pressure drop: 250 Pa
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Universal frame or clip
Comment: Additional information: Different clips available for
mounting combinations with different filters.

The 30/30GT® has been setting the standard for G4/MERV 8 panel pre-filters. The combination of the unique media, robust
construction and pleating technology makes the Camfil 30/30GT a low pressure drop pre-filter that performs well in all situations

Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

540F-FG070205001 30/30 GT 24x24x4 MERV 8 G4 Coarse 70% 594x 594x 95 4250/ 85 2.5 1.1

*540F-FG402312001 30/30 GT 24x24x4 MERV 8 G4 Coarse 70% 594x 594x 95 4250/ 85 2.5 1.1

*540F-FG402312001A 30/30 GT Special 24x24x4 MERV 8 G4 Coarse 70% 592x 592x 95 4250/ 85 2.5 1.1

*540F-FG402312005 30/30 GT Special 24x24x3.5 MERV 8 G4 Coarse 70% 592x 592x 89 4250/ 85 2.5 1.1

540F-FG406332005 30/30 GT Dual 10 24x24x4 MERV 9 G4 ePM10 50% 592x 592x 95 4250/ 85 2.5 1.1
*with gasket
*Available in Dual 10 media
*Turbomachinery ISO 29461-1 test standard is available upon customer reques

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Panel Filters

CamClose
Advantages
• Pre-filter with longer life and a • Optional built-in or external
lower and more stable pressure clips for easy installation
drop • Non-discharging, high
• Lightweight and easy to install efficiency media
• Can be used as hydrophobic or • High burst strength > 6250 Pa
a coalescing air filter (25” w.g.)
• Patented pressure drop port
for easy monitoring

Application: Suitable for most areas including wet and coastal


Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber, Synthetic
Separator: Hot-melt
Max. final pressure drop: 450 Pa
Max Temperature (°C): 70ºC
Relative Humidity max: 100%
Installation Options: Integrated clip on or optional without clip.
Separate metal clip available.
Comment: Additional Product Features : High mechanical
strength, Optimal coalescing performance, High strength plastic
frame, Downstream media support, Patented pressure drop port,
Downstream spacer for optimal airflow, Can be fitted directly to a
final filter with built-in clips.
The CamClose is Camfil’s new generation panel air filter designed to extend the service life of final filters. By adding the CamClose pre-
filter in front of the final filter, overall filtration efficiency is further improved.

CamClose has a user-friendly design, robust construction, and best-in-class water handling properties. These features make it an
excellent pre-filter for most turbomachinery and gas turbine applications. It is especially suitable for humid conditions such as tropical
and coastal installations. The CamClose pre-filter has been engineered to enable hassle-free operations, increased performance and
offers excellent protection.
Dimensions WxHxD Airflow/pressure drop Area Weight
Art. No. Type EN779 ISO29461-1 ISO16890
(mm) (m³/h/Pa) (m²) (kg)

CCLS00040001PE00MY CamClose GT 24245-G4-with clips G4 Coarse 60% 592x 592x 129 4250/ 55 2.4 3

CCLS00040001PU00MY CamClose GT 24245-G4-with clips G4 Coarse 60% 592x 592x 129 4250/ 55 2.4 3

CCLS00040101PE00MY CamClose GT 24245-G4-without clips G4 Coarse 60% 592x 592x 129 4250/ 55 2.4 3

CCLS00040101PU00MY CamClose GT 24245-G4-without clips G4 Coarse 60% 592x 592x 129 4250/ 55 2.4 3

CCLS00050101PE00MY CamClose GT M5-592*592*129-with clips M5 T5 ePM10 65% 592x592x129 4250/125 12 4.7

CCLS00050101PU00MY CamClose GT M5-592*592*129-with clips M5 T5 ePM10 65% 592x592x129 4250/125 12 4.7

CCLS00050001PE00MY CamClose GT M5-592*592*129-without clips M5 T5 ePM10 65% 592x592x129 4250/125 12 4.7


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

CCLS00050001PU00MY CamClose GT M5-592*592*129-without clips M5 T5 ePM10 65% 592x592x129 4250/125 12 4.7

CCLS00060101PE00MY CamClose GT M6-592*592*129-with clips M6 T6 ePM2,5 50% 592x592x129 3400/145 12 4.7

CCLS00060101PU00MY CamClose GT M6-592*592*129-with clips M6 T6 ePM2,5 50% 592x592x129 3400/145 12 4.7

CCLS00060001PE00MY CamClose GT M6-592*592*129-without clips M6 T6 ePM2,5 50% 592x592x129 3400/145 12 4.7

CCLS00060001PU00MY CamClose GT M6-592*592*129-without clips M6 T6 ePM2,5 50% 592x592x129 3400/145 12 4.7


Filter Class according to EN779:2012
*Please refer to CSG for other grade filter article number
*(Filter size: 592x592x129mm)
*Turbomachinery ISO 29461-1 test standard is available upon customer request

16
Gas Turbine Filtration | Panel Filters

CamClose Compact
Advantages
• High water removal efficiency • High strength ABS frame
• High dust holding capacity • Fully incinerable

Application: Pre-filter with high efficiency removal of water and mist


with medium efficiency removal of airborne particulates
Frame: ABS
Gasket: Polyurethane, Neoprene
Media: Glass fiber, Synthetic
Sealant: Polyurethane
Rec. final pressure drop: 450 Pa
Relative Humidity max: 100%
Comment: DIN 53438.

Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

5302001 Camclose Compact - 592x592x96-G4 MERV 7 G4 Coarse 70% 592x 592x 96 4250/ 60 2.3 2.5

5302005 CamClose Compact -592x592x96-M6 MERV 11 M6 ePM2,5 50% 592x 592x 96 4250/ 105 2.3 5.0
*Gasket is standard
*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Bag Filters

Cam-Flo GT Hybrid
Advantages
• Hybrid Technology media • High dust holding capacity =
• Maximum surface use long life
• High mechanical strength • Recommended choice for gas
• Incinerable bags turbine pre-filtration

Application: Installations exposed to turbulence and harsh


environments
Frame: Stainless steel, Galvanised steel
Gasket: Polyurethane, Neoprene, Flat gasket
Media: Hybrid Synthetic and Glass Technology
Rec. final pressure drop: 450 Pa
Max airflow: 1,8 x nominal flow
Max Temperature (°C): 70 °C
Comment: Additional Information :Available in half and special size
filters on request.

EFFICIENCY GUARANTEE

The Cam-Flo Hybrid is a new generation of premium bag filters for gas turbines that utilize the breakthrough Hybrid media technology
to combine glass fiber and synthetic fibers. The results is a smart solution for an extended filter life, a stable and predictable
performance, and most of all, carefree operations. Self-supporting bags and a unique design make this filter an excellent pre-filter and
coalescer choice for turbomachinery applications.

ASHRAE 52.2- Dimensions WxHxD Airflow/pressure drop Area


Art. No. Type EN779 ISO29461-1 Bags
2017 (mm) (m³/h/Pa) (m²)

3501501 CamFlo GT Hybrid M6-592*592-640*10-65-25 MERV 12 M6 T6 592x 592x 640 4250/ 80 10 8.5

3502003 CamFlo-GT Hybrid-592*592*-640*10-85 MERV 13 F7 T7 592x 592x 640 4250/ 90 10 8.51

3502001 CamFlo X7 Hybrid-620*580-600*10-85 MERV 13 F7 T7 595x 595x 600 4250/ 90 10 8.51

3502002 Cam-Flo X7 Hybrid-620*580-600*10-85 MERV 13 F7 T7 620x 580x 600 4250/ 90 10 8.49

3507002 CamFlo GT Hybrid F9 592*592-640*10-98-25 MERV 15 F9 T9 592x 592x 640 4250/ 165 10 8.5
*Also available in half size and shorter bag
*Turbomachinery ISO 29461-1 test standard is available upon request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Bag Filters

CamGuard
Advantages
• Guard filter in combination • Suitable for high velocity
with a high velocity bag filter applications
• Allows on-line filter
replacement of earlier stages

Application: Suitable for all environments including high velocity air


inlet systems. Typical for coastal and offshore installations
Pre-filter for gas turbines, large industrial air compressors, diesel &
gas engines, generators & enclosures
Frame: Stainless steel
Media: Synthetic
Max Temperature (°C): 70°C
Comment: Additional information: Designed for use in combination
with Cam-Flo GT HV.

The CamGuard is a coarse filter that is installed downstream of the Cam-Flo GTX7, allowing online filter replacement thus reducing
costly downtime.

Type Material EN779 Dimensions WxHxD (mm) Area (m²) Weight (kg)

CamGuard CCS Stainless steel G4 618x 577x 630 1,7 2

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Bag Filters

Hi-Cap GT
Advantages
• Optimized filter area with • High dust holding capacity
conical filter bags • Low pressure drop
• Resistant media • Incinerable bags

Application: Comfort air conditioning applications, gas turbines.


Frame: Galvanised steel, ABS
Gasket: Polyurethane, Neoprene, Flat gasket
Media: Polyester
Dimensions: Filter front dimensions according EN 15805
Rec. final pressure drop: 250 Pa
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Installation Options: Front and side access housings and frames are
available, Type 8 and FC Housings

Hi-Cap GT is a high quality filter, available for the removal of coarse particles. It allows for a secure and efficient filtration in industrial
environments where large amounts of dust are present. Long experience and continuous R&D has optimised the product for impressive
filtration at a low cost.

Art. No. Type ASHRAE 52.2-2017 EN779 ISO16890 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Bags Area (m²) Weight (kg)

3204012 Hi-Cap GT 592*592*6*360-G4 MERV 7 G4 Coarse 60% 592x 592x 360 4250/ 50 6 2.6 2.2

3204009 Hi-Cap GT 592*592-6*580-G4 MERV 7 G4 Coarse 60% 592x 592x 580 4250/ 30 6 4.2 3.2
Hi-Cap other dimensions available on request
*Turbomachinery ISO 29461-1 test standard is available upon customer request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Compact Filters (Header Frame)

CamPGT
Advantages
• F7 to E10 (EN779:2012 / • Light weight construction for
En1822) easy mounting
• ISO ePM1 70%, 85% and 95% • Downstream synthetic scrim
• Low pressure drop maximizes protection
equipment output • Fully incinerable
• Reduces fuel/energy
consumption

Application: Suitable for demanding operating conditions like heavy


polluted rural or industrial areas
Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt Separator Technology
Sealant: Polyurethane
Grille, Downstream: Support grid for filtermedia
Rec. final pressure drop: 450 Pa
Max Temperature (°C): 70ºC
Comment: Additional information : 4 side PU sealant with scrim on 8
pack and 4 side sealant with 2 side scrim also available.

The CamPGT is an energy efficient solution functioning as a high efficiency filter in Camfil medium velocity multistage inlet houses. It
is intended for inland industrial and rural areas. Its unique geometry provides a large inlet area and optimized air flow, thus offering a
lower pressure drop than industry standard for V-shaped barrier filters.

Airflow/pressure drop
Art. No. Type ASHRAE 52.2-2017 EN779 EN1822 ISO29461 -1 ISO16890 Dimensions WxHxD (mm) Area (m²) Weight (kg)
(m³/h/Pa)

PGT02011112210MY CamPGT 4H300 Std MERV 14 F7 ePM1 55% 592x 592x 292 4250/ 95 17 4,3

PGT02021112210MY CamPGT 4H300 Std MERV 15 F8 T7 ePM1 70% 592x 592x 292 4250/ 115 18 4,3

PGT02031112210MY CamPGT 4H300 Std MERV 16 F9 T9 ePM1 80% 592x 592x 292 4250/ 130 19 4,3

PGT02041112210MY CamPGT 4H300 Std E10 T10 592x 592x 292 4250/ 210 24 4,3
XL versions available on demand*
*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

16
Gas Turbine Filtration | Compact Filters (Header Frame)

CamGT 4V-300
Advantages
• Hydrophobic filter construction • Resistant to turbulence and
and media extreme pressure drop
• Low operational pressure drop, • Patented Aerodynamic support
even when wet, with patented grid for lower pressure drop
built-in drainage • Optimized media area for the
• Sealed on all sides and lowest pressure drop at EPA
featuring our patented double efficiency
sealing process

Application: All installations where safety/reliability/long life is


important, especially areas with high humidity/heavy rain
Pre- or final filter for gas turbines, large industrial air compressors,
diesel & gas engines, generators & enclosures, wind turbines
Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
EFFICIENCY GUARANTEE
Sealant: Polyurethane
Grille, Downstream: Support grid for filtermedia
Rec. final pressure drop: 600 Pa
Max airflow: 1,3 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Comment: Fire rating: Available according to DIN4102 class b2
rating on request
Burst strength: > 6250 Pa continuous wet/soaked
Reverse flow version: With support grid available on request
Additional information: Also available in 1/2 and 3/4 size on request.

CamGT 4V-300 is a high efficiency air inlet filter used for second and/or third stage filtration, depending on the gas turbine air inlet
system. Typical range from M6 or MERV 11 up to E12 (EPA level), for the best gas turbine protection. Also available in versions with Fire
rating DIN4102 class b2, Reverse flow, half-size and 3/4 size on request.

ASHRAE 52.2- Dimensions Airflow/pressure


Art. No. Type EN779 EN1822 ISO29461-1 ISO16890 Area (m²) Weight (kg) ePM1 ePM1min ePM2,5 ePM2,5min ePM10
2017 WxHxD (mm) drop (m³/h/Pa)

CGT1100111MY CamGT 4V-300 MERV 13 M6 Coarse 60% 592x 592x 300 4250/ 105 19 8.0

CGT1101111MY 4V-300-F7-Std MERV 13 F7 T7 ePM1 70% 592x 592x 300 4250/ 130 19 8 72 72 80 80 93

CGT1101211MY 4V-300-F7-XL MERV 13 F7 T7 ePM1 70% 592x 592x 300 4250/ 125 26 8.5 72 72 80 80 93

CGT1102111MY 4V-300-F8 MERV 14 F8 T8 ePM1 80% 592x 592x 300 4250/ 140 19 8 80 80 87 87 96

CGT1102211MY 4V-300-F8-XL MERV 14 F8 T8 ePM1 80% 592x 592x 300 4250/ 135 26 8.5 80 80 87 87 96
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

CGT1103111MY 4V-300-F9 MERV 15 F9 T9 ePM1 85% 592x 592x 300 4250/ 165 19 8 85 84 89 89 96

CGT1103211MY 4V-300-F9-XL MERV 15 F9 T9 ePM1 85% 592x 592x 300 4250/ 160 26 8.5 85 84 89 89 96

CGT1104111MY 4V-300-E10 E10 T10 592x 592x 300 4250/ 200 29 8.5 97 97 98 97 98

CGT1105111MY 4V-300-E11 E11 T11 592x 592x 300 4250/ 225 29 8.5

CGT1106111MY 4V-300-E12 E12 T12 592x 592x 300 4250/ 325 30 8.5
*EPA Class in green frame and F class filter in black frame

1
Gas Turbine Filtration | Compact Filters (Header Frame)

CamGT 3V-440
Advantages
• Hydrophobic filter construction • Resistant to turbulence and
and media extreme pressure drop
• Low operational pressure drop, • Patented Aerodynamic support
even when wet, with patented grid for lower pressure drop
built-in drainage • Optimized media area for the
• Sealed on all sides and lowest pressure drop at EPA
featuring our patented double efficiency
sealing process

Application: All installations where safety and reliability is crucial.


Low air resistance, long life and high dust concentrations
Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Grille, Downstream: Support grid for filtermedia
EFFICIENCY GUARANTEE
Rec. final pressure drop: 600 Pa
Max airflow: 1,8 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Comment: Reverse flow version: With support grid available on
request
Additional information: Also available in 1/2 and 3/4 size on request.

The CamGT 3V-440 is built on a solid 440 mm deep frame with extended media area. The unique design provides industry-leading
pressure drop and dust holding capacity ensuring optimum performance, low average pressure drop and a long filter life. The filter is
also available with CamBrane media in E12 efficiency.

Airflow/
ASHRAE Dimensions Area Weight
Art. No. Type EN779 EN1822 ISO29461-1 ISO16890 pressure drop ePM1 ePM1min ePM2,5 ePM2,5min ePM10
52.2-2017 WxHxD (mm) (m²) (kg)
(m³/h/Pa)

CGT0302111MY CamGT 3V-440-F8 MERV 14 F8 T8 ePM1 80% 592x 592x 440 4250/ 105 31 10.5 80 80 87 87 96

CGT0303111MY CamGT 3V-440-F9 MERV 15 F9 T9 ePM1 85% 592x 592x 440 4250/ 125 29 10.5 85 84 89 89 96

CGT0304111MY CamGT 3V-440-E10 E10 T10 592x 592x 440 4250/ 155 33 11 97 97 98 97 98

CGT0305111MY CamGT 3V-440-E11 E11 T11 592x 592x 440 4250/ 175 33 11

CGT0306111MY CamGT 3V-440-E12 E12 T12 592x 592x 440 4250/ 310 34 11

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
*EPA Class in green frame and F class filter in black frame
*Turbomachinery ISO 29461-1 test standard is available upon customer request

17
Gas Turbine Filtration | Compact Filters (Header Frame)

CamGT 3V-600
Advantages
• Largest media area for • Lowest air resistance (dP) for
longest life or higher airflows optimal economy
application • Solid HEPA frame eliminates
• High filtration efficiency (up to air bypass
H13) • Patented aerodynamic grid
• Patented vertical pleat • Meets the industry’s most
stringent requirements

Application: All installations where safety/reliability is crucial in


combination with low air resistance
Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt
Sealant: Polyurethane
Grille, Downstream: Support grid for filtermedia
Rec. final pressure drop: 600 Pa
EFFICIENCY GUARANTEE
Max airflow: 1,8 x nominal flow
Max Temperature (°C): 70°C
Relative Humidity max: 100%
Comment: Burst strength: > 6250 Pa continuous wet/soaked.
Additional information: Also available in reverse configuration with
metal faceguard.

The CamGT 3V-600 is built on a solid 600 mm deep frame with extended media area. The unique design provides industry-leading
pressure drop and dust holding capacity ensuring optimum perfomance, low average pressure drop and a long filter life. The filter is
also available with CamBrane media in E12 efficiency.

Airflow/pressure drop Area Weight


Art. No. Type ASHRAE 52.2-2017 EN779 EN1822 ISO29461-1 ISO16890 Dimensions WxHxD (mm)
(m³/h/Pa) (m²) (kg)

CGT0202111MY CamGT 3V 600-F8-Std MERV 14 F8 T8 ePM1 80% 592x 592x 600 4250/ 100 41 15

CGT0203111MY CAM GT 3V 600-F9-Std MERV 15 F9 T9 ePM1 85% 592x 592x 600 4250/ 115 38 15

CGT0204111MY CamGT 3V 600-E10-Std E10 T10 592x 592x 600 4250/ 135 45 16

CGT0205111MY CamGT 3V 600-E11-Std E11 T11 592x 592x 600 4250/ 140 48 16

CGT0206111MY CAM GT 3V 600-E12-Std E12 T12 592x 592x 600 4250/ 190 50 17
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

*EPA Class in green frame and F class filter in black frame


*Turbomachinery ISO 29461-1 test standard is available upon customer reques

17
Gas Turbine Filtration | Compact Filters (Box Type)

CamGT Box Type G II


Advantages
• Ensures water drainage • Resistant to turbulence and
• High filtration efficiency high pressure drop
• Low pressure drop also in wet • Easy mounting
conditions • Water resistant media

Application: All installations where safety/reliability is important


Frame: Plastic moulded
Gasket: Polyurethane, endless foamed
Media: Glass fiber
Separator: Hot-melt Separator Technology
Rec. final pressure drop: 600 Pa
Max Temperature (°C): 70°C
Comment: Additional information: XL version available on request.
Profile placed at 292 mm depth for clamping, i.e for fastener spring
type C-80.

EFFICIENCY GUARANTEE

CamGT Box Type G is a high-capacity filter for turbomachinery. Thanks to the unique design, its performance is maintained in humid or
wet conditions, guaranteeing a long lifetime and a good filter economy.

Art. No. Type ASHRAE 52.2-2017 EN779 EN1822 Dimensions WxHxD (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

2472001 Cam GT Box Green II 592*592*315-F7-01 MERV 13 F7 592x 592x 315 4250/ 140 19 7,3

2472004 Cam GT Box Green II 592*592*315-F9-01 MERV 15 F9 592x 592x 315 4250/ 200 19 7,3

2472007 Cam GT Box Green II 592*592*315-E10-01 E10 592x 592x 315 4250/ 240 19 7,3

2472010 Cam GT Box Green II 592*592*315-F7-01 (XL) MERV 13 F7 592x 592x 315 4250/ 135 22 7,8

2472013 Cam GT Box Green II 592*592*315-F9-01 (XL) MERV 15 F9 592x 592x 315 4250/ 190 22 7,8

2472016 Cam GT Box Green II 592*592*315-E10-01 (XL) E10 592x 592x 315 4250/ 220 22 7,8
*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

Advantages
• •

• •


• •


Application:

Gasket:
Media:

Max Temperature (°C): 70ºC


Pleat: HemiPleat
Comment:

Length (mm) Diameter (mm) Length 2 (mm) Diameter 2 (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

678 447-360 678 360-322 2500/ 160 13.5

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

CamPulse GTC
Advantages
• HemiPleat ™technology- • 2 in 1 package - saves space
proven open pleat solution and money
• Non discharging F9 • Optimal ability to handle daily
• Water resistant media fog and humidity
• Improved dust release • Helicord design for efficient
pulse cleaning

Application: For humid/dry heavy dust load areas. Our


recommended choice for one-stage self cleaning air intake systems
Gasket: Polyurethane, endless foamed, EPDM
Media: Synthetic
Max Temperature (°C): 70º C
Pleat: HemiPleat
Comment: End caps: Available Galvanized steel (Standard), Powder
coated, Stainless steel AISI304, Stainless steel AISI 31
Liners: External helical cords and internal screen, secure the filter
element from movement without obstruction to the pulse
Additional information: Available in Co/Cy, Tenkay, and in other
dimensions on request.

Our conical-cylindrical air inlet filters are available in vertical or horizontal designs, to best suit your system of choice. With our broad
range of media, including EPA filters, we can offer an air inlet pulse filter for every environment and every gas turbine inlet. Camfil
CamPulse with proven HemiPleat™ technology, combined with a synthetic media, delivers valuable benefits to gas turbine operation
and maintenance.

Airflow/
ASHRAE Length Diameter Length 2 Diameter 2 pressure
Type EN779 EN1822 ISO16890 Area (m²) Weight (kg) ePM1 ePM1min ePM2,5 ePM2,5min ePM10
52.2-2017 (mm) (mm) (mm) (mm) drop (m³/h/
Pa)

CyCy MERV 15 F9 ePM1 80% 660 324 660 445 2500/ 145 35 12 84 83 88 88 96

CoCy MERV 15 F9 ePM1 80% 660 324 660 445 2500/ 200 35 12

CyCy MERV 15 E10 660 324 660 445 2500/ 140 35 12

CoCy MERV 15 E10 660 324 660 445 2500/ 200 29 12


CyCy = Large Cylindrical, Small cylindrical
CoCy= Large Conical, Small Cylindrical
*Turbomachinery ISO 29461-1 test standard is available upon customer request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

CamPulse GT Polytech HE
Advantages
• Patented HemiPleat™ • Improved air distribution
technology- proven open • Suitable also in high humidity
• Water repellent media conditions
protected by metal liners • Suitable as prefilter for filter
• Each filter set is shipped class E10, E12
together in one carton • Increased air to cloth
• Galvanized metal finish ratio thanks to Hemi-Pleat
• Self-cleaning air filter ™technology.
cartridges

Application: For desert/dry/ heavy dust load areas


Gasket: Polyurethane, endless foamed, EPDM
Media: Polytech HE
Max Temperature (°C): 70º C
Pleat: HemiPleat
Comment: Additional information: Available as dimple pleated and in
fire retardant version on request.

Camfil CamPulse with proven HemiPleat™ technology, combined with a synthetic media, delivers valuable benefits to gas turbine
operation and maintenance.

Type ASHRAE 52.2-2017 EN779 Length (mm) Diameter (mm) Length 2 (mm) Diameter 2 (mm) Airflow/pressure drop (m³/h/Pa) Area (m²) Weight (kg)

CyCy MERV 16 F7 660 324 660 445 2500/ 165 34.7 12.8

CoCy MERV 16 F7 660 324 660 445 2500/ 195 34.7 12.8
CyCy = Large Cylindrical, Small cylindrical
CoCy= Large Conical, Small Cylindrical
*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

Tenkay
Advantages
• High filtration efficiency • Factory bonded steel top and
• Excellent energy performance bottom headers
• Long life • Pleated media
• Continuous one-piece gasket • Helical cord retainer

Application: Vertical pulse filter for desert/dry/ heavy dust load


areas
Gasket: Polyurethane, endless foamed, EPDM
Media: Synthetic, Membrane, Polytech HE
Rec. final pressure drop: 600
Max Temperature (°C): 70º C
Comment: Size: Standard 34”, 22” and 27” on request.
Additional information: Also available as CamBrane E12, Goldcone,
and eXtreme versions on request.

The Tenkay HemiPleat™ filters for turbomachinery provide enhanced performance and longer service life, thanks to greater media
utilization and more effective filtration. The HemiPleat™ separator bead opens up the pleats uniformly, allowing more effective cleaning,
low pressure drop and long life.

Type ASHRAE 52.2-2017 EN779 EN1822 Length (mm) Diameter (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

Polytech HE MERV 13 F7 864 324 1150/ 145 8,6

GTC MERV 16 F9 864 324 1150/115 8.6

GTC MERV 15 E10 864 324 1150/ 130 3.8


Energy Consumption, kWh/year: Calculated according to Eurovent Guideline 4/21-2019
Energy class: according to Eurovent RS 4/C/001-2019
*Turbomachinery ISO 29461-1 test standard is available upon customer request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

Composite Filters Polytech Nano


Advantages
• High filtration efficiency • The nano layer acts like a
• Excellent energy performance pre-filter to the base media
• Long life time and doesn’t allow most dust
• One-piece gasket provides particles to “depth” load or
rigidity and eliminates leakage imbed in the media
• Dimple pleating increased
media area available for
filtration

Application: All installations where safety/reliability is important


Gasket: Polyurethane
Media: Polytech Nano
Comment: End caps: Galvanized or Stainless Steel (top & bottom)
Rec. temperature - Operating: 71°C
Rec. temperature - Surge: 82°C
Standard configuration: Cylindrical element type

The composite cartridge filter has two stages in a composite design: an inner filter that works as a pre-filter extending the life of
the final filter and a high efficiency outer filter. The inner filter is a depth loading high loft synthetic with high air permeability. It is
constructed with a reusable velcro retainer attached to the inside of the top filter pan for easy installation and removal. Typically
changed more often than the outer filter it protects against coarse particles, humidity and salt.

The outer filter is synthetic non-discharging fibre media resistant to humidity and able to withstand high dust load concentrations. The
medias unique properties give the filter a high level of efficiency over its entire lifetime. The smooth synthetic fibres offer low resistance
to airflow and maintain a low pressure drop during the life of the filter. The combination of surface- and depth-loading media is the
ideal solution for removing hygroscopic particles in areas of high humidity, which makes this the perfect choice for most installations.

Type EN779 Length (mm) Diameter (mm) Length 2 (mm) Diameter 2 (mm) Airflow/pressure drop (m³/h/Pa)

Composite Filter F8 660 355 660 446 3400/ 220


*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

Composite Filters GTC (LM6000 Series)


Advantages
• High filtration efficiency • HemiPleat™ technology
• Excellent energy performance - Uniform media pleating
• Long life time allows for minimum airflow
• One-piece gasket provides restrictions and lower pressure
rigidity and eliminates leakage drop

Gasket: Polyurethane
Media: Synthetic
Comment: End caps: Galvanized or Stainless Steel (top & bottom)
Rec. temperature - Operating: 71°C
Rec. temperature - Surge: 82°C
Standard configuration: Cylindrical element type

The LM6000 series fit GE’s LM6000 Air Inlet Systems. The cartridge has two filtering stages in a composite design: an inner filter that
works as a pre-filter extending the life of the final filter and a high efficiency outer filter. The inner filter is a depth loading high loft
synthetic with high air permeability. It is constructed with a reusable velcro retainer attached to the inside of the top filter pan for easy
installation and removal. Typically changed more often than the outer filter it protects against coarse particles, humidity and salt.

The outer filter is our GTC synthetic non-discharging fibre media resistant to humidity and able to withstand high dust load
concentrations. The GTC media unique properties give the filter a high level of efficiency over its entire lifetime. The smooth synthetic
fibres offer low resistance to airflow and maintain a low pressure drop during the life of the filter. The combination of surface- and
depth-loading media is the ideal solution for removing hygroscopic particles in areas of high humidity, which makes this the perfect
choice for most installations. The outer filter pack also has patented open HemiPleat™ construction with uniformly spaced pleats
across the length of the pack.

Type EN779 Length (mm) Diameter (mm) Length 2 (mm) Diameter 2 (mm) Airflow/pressure drop (m³/h/Pa) Media Type

LM6000 Series GTC F9 660 355 660 446 3400/ 235 Synthetic
*Turbomachinery ISO 29461-1 test standard is available upon customer request
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

17
Gas Turbine Filtration | Cartridge Filters

CamPulse CamBrane
Advantages
• Self-cleaning cartridge filter • High availability and highest
with long filter life and low and reliability
stable pressure drop • Best fuel efficiency leads to
• Improved pulsability due to lower CO2 emissions per MWh
HemiPleat open-pleat media • E12 grade limits degradation
technology such as fouling and corrosion
• Good pulsability with depth- • Suitable for harsh
loading and multi-layer media environments
technology

Application: Humid or dry heavy dust load areas, coastal and fine
hydrocarbon environments
Pre- or final filter for gas turbines, large industrial air compressores,
diesel & gas engines, generators & enclosures
Gasket: Polyurethane, endless foamed, EPDM
Media: Membrane
Max Temperature (°C): 70ºC
Pleat: HemiPleat
Comment: End caps: Available in Galvanized steel (Standard), Power
coated, Stainless steel AISI304, Stainless steel AISI 316
Construction with outercage and innercage also available as
Cylindrical/Conical.

The CamBrane combines a variety of filtration technologies into one unique composite media tailored for the tough requirements of
modern gas turbines. The synthetic pre-filter layer is extremely efficient on small particles, hydrocarbons and airborne salt while the
membrane layer adds a barrier to submicron particles and stops water and salt from penetrating the filter. CamBrane offers best-in-
class protection at lowest possible air flow restriction.

Type EN1822 Length (mm) Diameter (mm) Length 2 (mm) Diameter 2 (mm) Airflow/pressure drop (m³/h/Pa) Weight (kg)

CyCy E12 660 324 660 445 2500/ 180 12

CoCy E12 660 324 660 445 2500/ 285 12


CyCy = Large Cylindrical, Small cylindrical
CoCy= Large Conical, Small Cylindrical
*Turbomachinery ISO 29461-1 test standard is available upon customer request

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1
Dust, Fume & Mist Collectors

Products

Dust Fume Collectors Dust Fume Collectors Dust Fume Collectors Dust Fume Collectors
Gold Series Gold Series Camtain Quad Pulse Package Quantum Series
Page 182 Page 183 Page 184 Page 185

Dust Fume Collectors Dust Fume Collectors Machining Mist Collectors Machining Mist Collectors
Handte Wet Scrubbers Zephyr III Portables Handte EM Profi Handte Oil Expert
Page 186 Page 187 Page 188 Page 189

Filter Cartridges Filter Cartridges Filter Cartridges Filter Cartridges


HemiPleat® Gold Cone Dura-Pleat Gold Cone HemiPleat® Retrofit Oval Retrofit
Page 190 Page 191 Page 192 Page 193
As part of our continuous improvement, Camfil reserves the right to change specifications without notice.

1
Dust, Fume & Mist Collectors | Dust Fume Collectors

Gold Series®
Advantages
• High efficiency collector using • Easy to install and maintain
HemiPleat® cartridges • Simple cartridge replacement
• Modular design for optimum using quick release cam bars
flexibility • Up to 25% smaller
• Customised for Original Equipment • ATEX and NFPA available upon
Manufacturers (OEM) request

Application: The Gold Series® cartridge dust and fume collectors may be used for a wide range of pollution control and product
recovery applications including: Blasting, Chemical Processing, Pharmaceutical Manufacturing Processes, Fiberglass and FRP, Food
Processing, Laser/Plasma Cutting, Paper Scrap, Rubber Grinding, Seed Processing, Mining, Thermal Spray and more. Contact Camfil
for more information

Type: Dust collector

Options: A wide variety of options are available including: Explosion Venting, Special Inlet Designs, BIBO (bag in-bag out) for
Pharmaceutical Applications, Custom Colours, Stainless Steel Construction, Alternative Hopper Designs etc. please contact us with
your specific requirements

Cartridges: Vertically mounted to shed dust readily for efficient cleaning and longer service life. High filtration efficiency meeting the 5
mg/m³ or less emissions required to re-circulate the air back into the work place on non hazardous dusts

Features

• Modular design for optimum flexibility-have it your way fast!


• Each module accommodates airflows up to 8,500 m3/h
• Module constructed of 4.5mm thick carbon steel
• Door, hopper, inlet and panels are all 3.4mm thick
• Powder painted for unsurpassed corrosion resistance
• Component configurations are virtually unlimited
• Vertical design of cartridges enables efficient pulse cleaning of dust

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Easy Maintenance
Simple, quick-open heavy gauge door(s) provide access to a super-fast cartridge change-out system that does not require entry into the collector. The door
is fully reversible for access from either side and has an exclusive lock-out feature for worker safety.

Easy Access Door

• No knobs to lose or drop


• No threads to bind
• Mechanically attached seal
• Heavy 3.4mm thick construction

Easy Change-out

Gold ConeTM cartridge with patented cambar action that positively seals the cartridges without using threads or knobs.

18
Dust, Fume & Mist Collectors | Dust Fume Collectors

Gold Series® Camtain®


Advantages
• Designed specifically for • Modular design for optimum
pharmaceutical and containment flexibility
applications • Customised for Original Equipment
• Bag-in/bag-out safe change options Manufacturers (OEM)
available. • Easy to install and maintain
• High efficiency collector using • Simple cartridge replacement
HemiPleat® cartridges using quick release cam bars
• Up to 25% smaller

Application: The Farr Gold Series® Camtain® is used in a wide range of pharmaceutical applications including tablet presses, coating,
fluid bed and spray drying, blending, granulation and general ventilation. Contact Camfil for more information

Type: Dust collector

Options: A wide variety of options are available including: BIBO

(bag-in/bag-out) for Pharmaceutical Applications, Explosion Venting, Special Inlet Designs, Custom Colours, Stainless Steel Construction,
Alternative Hopper Designs etc. please contact us with your specific requirements

Cartridges: Vertically mounted to shed dust readily for efficient cleaning and longer service life. High filtration efficiency meeting the 5
mg/m³ or less emissions required to re-circulate the air back into the work place on non hazardous dusts

Features

• Safe-change containment systems are available for both the filter cartridges and discharge
system underneath the collector.
• The cartridge change utilizes the safe change filter replacement method while the discharge
uses continuous liner technology.
• The Farr Gold Series Camtain is perfect for high efficiency filtration in pharmaceutical
manufacturing processes where recovery of the product is not required.
• The only dust collector that is potent compound surrogate tested for validated performance
verification. Test report available upon request.
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

18
Dust, Fume & Mist Collectors | Dust Fume Collectors

Quad Pulse Package


Advantages
• Economical, space-saving cleaning • Low pressure drop across the filter
unit requiring just a single primary for energy cost savings
filter cartridge • Camfil pleated filter technology
• Cleaning during operation for provides exceptional dust release
production process and product enabling extended filter service life
quality control and reduced filter replacement
• EN14460:2006 Explosion
Resistance Equipment

Application: The Quad Pulse Package compact dust collector provides a


cleanable filter system for the pharmaceutical and chemical industries

Type: Dust collector

Compact and strong unit construction incorporates a unique HEPA filter design, with specialized materials from the aerospace industry, providing the
following key advantages:
• The Quad Pulse Package HEPA filter captures the fine dust particles and is a tested flame and contamination barrier.
• Additional, expensive explosion safety devices are not required.
• The pressure resistant housing maintains its integrity with no damage during an explosion event.
• Compact unit with flexibility for indoor installation reduces the need for long duct runs.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

18
Dust, Fume & Mist Collectors | Dust Fume Collectors

Quantum Series
Advantages
• Integrated spark arrestor • Minimum footprint; maximum
• Easy to install • performance
• Economical • Newest pulse cleaning technology

Application: Welding (laser and manual) Laser and plasma cutting Dry
machining. Non-explosive fine dust Shot blasting

Type: Dust collector

Installation Options: Fire suppression; Smoke detection; HEPA; Oneside


service access.

Description:

The Quantum Series is a compact and powerful, fine dust collector designed for the metal fabrication, thermal cutting and welding markets.
The Quantum Series’ integrated spark arrestor and improved filter design allows this unit to provide the highest levels of efficiency and
safety. Quantum Series product shot facing left. Designed to take up the minimum possible floor space, the Quantum Series can be located
close to your processes in order to minimize duct work and reduce fire hazards created by sparks. Built with decades of proven filtration
industry knowledge and expertise, the Camfil APC Quantum Series includes design features and high-end technology which has been tested
and proven in our range of market-leading dust and fume collectors.

Comment:

Incorporating Camfil APC’s advanced filter design, the Quantum Series prevents the common filter failures suffered by competitive collectors. A patent
pending filter segmenting and volume displacement design improves pulse cleaning efficiency and reduces the chance for re-entrainment and clogging,
while also reducing pulsing energy and noise. A strategically placed and fully integrated spark arrestor allows for higher separation efficiency and smaller
footprint.

Spark Arrestor: As sparks can cause poor performance, damage the collector and filter media or present a fire hazard, many dust collectors require
an external spark arrestor that is expensive and requires more floor space. The Quantum Series has been designed to avoid these issues. Key Aspects:
Integrated in the unit; Cyclonic separation of fine laser dust and metal sparks; Coarse, hot particles collected in separate bin; •1500 m³/h - 6000 m³/h;
Unique, patent pending design
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

18
Dust, Fume & Mist Collectors | Dust Fume Collectors

Handte Wet Scrubbers


Advantages
• No filter elements required • Universal applications
• The safest solution when dealing • High-level separation combined
with flammable/combustible with safe operating technique
materials • Low-maintenance

Application: The Handte Vortex and Handte Venturi wet scrubber systems
provide high-efficiency and low-maintenance removal of dusts and other
hazardous substances from the workplace

Type: Wet Scrubber

Handte wet scrubbers are for applications where hazardous substances are in production processes. Examples:

• Steam: Washing machines, waste treatment, soldering, die-casting machines, releasing agents, paint vapors, cooling aggregates, spark discharge
material removal machines, paint-stripping units, electro-plating units, lead production, electro-galvanizing plants, foundries
• Aluminum magnesium dust: Minimal lubrication, grit production, chip removal, de-burring, brushing, separating, finishing processes, forging processes,
grinding and polishing
• Aluminum magnesium chippings: Drilling, machining, rough machining, sawing, de-burring, forming processes, recycling systems
• Rubber/leather/plastic fines: Shoe manufacturing, tire re-treading, plastics processing, foils
• Production, extruders, modeling, textiles manufacturing
• Fibers/fluff/textile dust: Polishing processes, paper machines, waste sorting systems, textile processing, recycling plants, insulation material
production, asbestos abatement, food processing, grain processing
• Sticky powders: Pharmaceutical processes, manufacturing of food, animal feed, dyes, mold and die manufacturing, printing machines, tire and chip
production, adhesive applications, textile finishing, mixing and conveying plants, plastics processing, ceramic coating

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

18
Dust, Fume & Mist Collectors | Dust Fume Collectors

Zephyr IIITM Portables


Advantages
• Portable air purification system • Complete unit-plug it in and start
• Ideal for industrial process collecting dust and fumes
contamination, source capture, and • Portable
for plants requiring periodic dust • The only thing you need to
collection at various locations supply is the electrical feed and
compressed air line

Application: The Zephyr is a portable air cleaner for capturing welding fumes,
grinding dusts, dry dusts, and soldering fumes, and other airborne particles.
Not suitable for explosive dusts & solvent fumes.

Features

• Roll out dust drawer


• Quick clamp cartridge sealing/removal
• Exterior arm adjustments
• Heavy duty fume arm is obstruction free inside
• Easy, 360º hood positioning
• 1200 m3/h at the capture hood
• Three stage filtration: Primary spark trap, Gold Cone® HemiPleat® and Carbon after filter for
ozone only
• Large wheels with swivels and brakes for ease in moving and positioning
• Tough powder coated surface finish inside and outside
• Venturi assisted pulse cleaning, manually activated
• Dust drawer grid minimizes dust re-entrainment
• Thermal overload in motor starter switch
• 7.5 m extension cord
• The only thing you need to supply is the electrical feed and compressed air line
Built-in fan with 160 mm Dia. x 3 mtrs long
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

motor overloads collection arm standard

Camlock cartridge seal On/Off 1200 m3/h and 4.2 m/s


switch face velocity

Compressed air
reverse pulse
cleaning system
Reverse pulse
button on side
Carbon final filter
for ozone only

Compressed
Clean air exhaust air reservoir

Spark trap
metal filter

HemiPleat® fire re-


tardant filter shown

Primary dust tray

18
Dust, Fume & Mist Collectors | Machining Mist Collectors

Handte EM Profi
Advantages
• Modular, user-friendly design to • No Leaks - guaranteed. German
provide a high-end solution for engineering and American
high-efficiency emulsion (coolant) manufacturing expertise result
mist separation in premium quality products. We
• The highest available collection guarantee that our mist collectors
efficiencies, plus the ability to run will not leak
“24/7” for reduced maintenance, • Multi-stage Filtration - We
service ease and lower operating consistently achieve high
costs separation performance by
designing our filter materials to
meet specific needs or to handle
a given droplet spectrum. We
do this through optimized, flow-
engineered, multistage design

Application: Handles the heaviest loads encountered in the industry to clean up contaminants generated during milling, drilling,
tapping, turning, grinding and other machining processes that utilize emulsion mist coolants

Type: Mist Separator

Modular Design: Minimum space requirement, maximum performance. System can be expanded in the future as needed. Short
delivery time. Easy transport and installation

Basic Modules: Ground/platform versions with optional return pump station (for recirculating separated fluids). Filter module (contains
main and final filter).Connection box for use with an external fan. Connection can be on left, right or rear side. Built-in fan in compact
design enclosure with integrated sound insulation. Top mount fan

Product Name Air Volume m3/h Dimension (WxD) mm mm Weight (kg)

Handte EM Profi 3.0 3000 798 x 958 2942 555

Handte EM Profi 4.5 4500 798 x 1208 2102 705

Handte EM Profi 6.0 6000 1548 x 958 2127 850

Handte EM Profi 9.0 9000 1548 x 1208 3461 1625

Handte EM Profi 13.5 13500 2298 x 1208 3525 2139

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

18
Dust, Fume & Mist Collectors | Machining Mist Collectors

Handte Oil Expert


Advantages
• Economically efficient separation • Air flow can be adjusted without
of ultra-fine cooling liquid mists and affecting the collection efficiency
fumes • Operator-friendly due to low-
• Collection efficiencies at 99.97% maintenance design
on 0.3 micron and higher particle • Tool-free filter changes with quick-
size with the optional HEPA final acting clamps
filter • Optional clean air recirculation
• Long-life filters • Plug-and-play delivery
• 24/7 operation

Type: Mist Separator

Progressive filtration design: The progressive design of ascending filter


classes provides the highest filtration efficiency available in the industry. This
includes the coarse separator mesh for high contamination, the standard
CoaPack diffusion filter as a preliminary filter, a fine filter and the optional
downstream final stage filter. This design makes it possible to configure the
system for simple applications or for highly complex requirements such as clean
air recirculation. This is especially true for ultra-fine mists and fumes generated
in the course of high-performance machining

Modular design for flexible configuration: The compact, modular design


of the Handte Oil Expert provides for easy, efficient adaptation to specific
requirements and installation situations. It is available in four standardized basic
modules with different air capacities, which can be combined in a large central
system. State-of-the-art technology enables flexible adjustment for system
conversions or expansion as production requirements increase

Innovative filter media: The unique structure of the standard CoaPack filter
material combines premium separation performance with self-cleaning features
via optimum drainage of the separated cooling lubricant. This ensures extremely
long filter life of the optional HEPA final filter

Easy filter change for simple, clean maintenance: The operation of


the Handte Oil Expert is practically maintenance free. When infrequent filter
changes are needed, the change-out is clean, easy and requires no tools. The
closed filter cassettes can be removed without being exposed to the oil coated
filter materials

Customizable: By combining different basic modules, it is possible to design


economically efficient central extraction systems for each requirement capable
of air volumes of 41,000 cfm or more. The modular concept of the Handte Oil
Expert provides for smooth, cost-efficient production conversions or extensions
during ongoing operation
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

With increasing production in modern manufacturing, energy consumption continues to grow, particularly in machining processes where cooling lubricants
are used. As a result, there are higher demands for the separation of ultra-fine mists and fumes. Worker safety, production efficiency and capital
equipment protection cannot be compromised. The Handte Oil Expert provides for optimum results even under the most challenging conditions.

Product Name Air Volume m3/h Dimension (WxD) mm mm Weight (kg)

Handte Oil Expert 3.0 3000 770 x 1190 2900 - 3900 1075

Handte Oil Expert 4.5 4500 770 x 1735 3050 - 4200 1420

Handte Oil Expert 6.0 6000 1240 x 1190 3020 - 4380 1745

Handte Oil Expert 9.0 9000 1240 x 1190 3035 - 4620 2585

Handte Oil Expert 13.5 13500 1784 x 1735 3400 - 4620 3895

18
Dust, Fume & Mist Collectors | Dust Fume Filters

HemiPleat® Gold ConeTM


Advantages
• Original spare for Farr Gold Series ® • Excellent energy saving
dust collectors performance
• Vertically integrated cartridge for • Extended Filter Life
better dust release and ease of • High Filtration Efficiency
removal and installation • Pour in place one piece double
gasket

Application: Air Pollution Control filter cartridge to collect dust, fumes and/or oil mist in many different industrial applications and
processes

Type: Pleated Cylinder

Gasket: Polyurethane, endless foamed

Separator: HemiPleat Separator Technology

Sealant: Polyurethane

Temperature max: 70º Operating

Mounting/Frames: Internal GV support cage

Filter Class: M

• Featuring an injection molded inner cone in the center of the cartridge, cleaning is accomplished by pulse waves that emanate outward from this inner
cone providing enhanced cleaning for more efficient operation, longer cartridge life and reduced service requirements.
• The new PolyTech™ media is the most advanced pulse-cleaned media ever made, and now comes standard with a moisture resistant treatment for
high humidity resistance.
• Continuous double seal gaskets give added insurance against leaks. No other filter design gives you a double seal barrier.
• The separation beads, NOT the media beads, contact the inner cage, protecting the media from frictional damage.
• The HemiPleat separator bead opens up the pleats uniformly, allowing more effective cleaning and lower pressure drop.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
Art. No. Model Name Length (mm) Diameter (mm) Media area (m²) Weight (kg) Media Type

325325-001 GS-GR-325 990 381 30.20 15 Standard Green

325325-002 GS-FR-325 990 381 30.20 15 Fire Retardant

325325-003 GS-CB-325 990 381 30.20 15 Carbon Impregnated

325325-004 GS-XG-325 990 381 30.20 15 eXtreme Green

325325-005 GS-XF-325 990 381 30.20 15 eXtreme Fire Retardant

325325-006 GS-XC-325 990 381 30.20 15 eXtreme Carbon Impreg-


nated

325325-007 GS-SY-325 990 381 30.20 15 Synthetic

325325-008 GS-XS-325 990 381 30.20 15 eXtreme Synthetic

1
Dust, Fume & Mist Collectors | Dust Fume Filters

Dura-Pleat® Gold Cone®


Advantages
• Meets widest range of tough • Exceptionally rugged, long-lasting
application challenges;handles • Vertically integrated cartridge for
difficult dusts better dust releaseand ease of
• Washable media may be resused in removal and installation
many applications

Application: Dura-Pleat media is made of 100% spun bond polyester in a


pleated design that combines the best of both worlds: the high efficiency of
pleated media and the versatility of synthetic materials.
Filter cartridges with Dura-Pleat technology capture and release more
pollutants when pulsed, resulting in a safer, cleaner work environment with less
maintenance.

Media Options
DPS - Dura-Pleat
Our spun-bonded, heavy-duty, all-purpose polyester media.

DPA - Aluminized
Our Dura-Pleat media with a conductive aluminized finish applied for static dissipation.

DPO - Hydro-Oleophobic
Our Dura-Pleat media coated with an oil and water repellent finish.

DPT - PTFE
Our Dura-Pleat media with a laminated polytetraflouroethylene (PTFE) membrane for very high efficiencies of fine particulate and
superior dust cake release.

Dura-Pleat filters are rated MERV 10up to MERV 16 (PTFE).


As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

1
Dust, Fume & Mist Collectors | Dust Fume Filters

HemiPleat® Retrofit
Advantages
• Less energy consumption • Lower pressure drop
• Fewer filter change outs • Saving you money
• Better dust release • Longer filter life

Application: Synthetic beads are applied to our media in order to achieve even
and open spacing. The open pleats create topmost utilization of media area
resulting in longer lasting and highly efficient filter cartridges.

Camfil APC filter cartridges with HemiPleat technology have sizable dust loading
capacity and allow for maximum dust release when pulsed. These industry
superior characteristics result in a cleaner, safer and lower maintenance work
environment.

Media Options
GR — Green
Our own blend of fibers with a moisture resistant treatment for the best dust release,
long filter life and high filtration efficiencies.

FR — Flame Retardant
Our own blend of fibers, chemically treated with a flame retardant.

FC - FR Carbon Impregnated
Our own blend of fibers, impregnated with carbon for static dissipation and chemically
treated with a flame retardent.

SY — Synthetic
A lightweight, washable polyester media.

HemiPleat filters are rated MERV 10 and higher.

HemiPleat High Efficiency filters are available for the GR, FR, and FC media options. A microfiber synthetic melt blown laminate is applied to the surface of
the base media for high filtration efficiencies and are rated MERV 16.

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

19
Dust, Fume & Mist Collectors | Dust Fume Filters

Oval Retrofit
Advantages
• Low pressure drop • High Filtration effeciency
• Extended filter life • Direct fit replacement

Application & Dust Type


• Wood & paper dust
• Talc & cornstarch
• Sand & shot blasting
• Foundry sand
• Sanding dust
• Thermal spray
• Welding & soldering
• Fumed silica dust
• Steel grinding
• Laser cutting
• PVC dust
• Carbon black
• Toner dust
Media Options
FC — FR Carbon Impregnated
Our own blend of fibers, impregnated with carbon for static dissipation and chemically treated with a flame retardant.

XF — eXtreme Flame Retardant


Our own blend of fibers, chemically treated with a flame retardant with the proprietary coating of nanofibers to yield the market’s most superior filtration
and cleanability with an efficiency of 99.995% on 0.5 microns and larger by weight.

XFC — XFC - eXtreme Flame Retardant Carbon Impregnated


Blended media impregnated with carbon for static dissipation, chemically treated with a flame retardant, and coated with nanofibers for superior filtration
and cleanability.

Efficiency for eXtreme Media:


ASHRAE 52.2: MERV 15 Filter Class M, in accordance to independent test to DIN EN 60335-2-69:2016
As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

110 μm 1150x 60 μm 2050x


Camfil APC’s Filter Media Camfil APC’s Filter Media with eX-
treme coating

19
Dust, Fume & Mist Collectors | Explosion Protection Solutions

Explosion Protection Solutions

Inlet Protection Outlet Protection


Fast-Acting Valve Integrated Safety
Designed to close within milliseconds of detecting an
explosion, the fast-acting valve installs in either inlet and/
Monitoring Filter
or outlet ducting. The fast-acting valve creates a mechanical The iSMF has been proven to isolate
barrier within the ducting, which effectively isolates pressure the downstream equipment from the
and flame fronts (from either direction) from being able to progression of a flame front during
propagate further through the process. an explosion. The Farr Gold Series®
dust collector with an integrated
Safety Monitoring Filter allows you
Inlet/Outlet Chemical Isolation to recirculate exhaust air back into
Designed to react within the work space when your dust is
milliseconds of detecting an explosive. The key advantage of
explosion, a chemical isolation this device is that it prevents the
system can be installed in either transmission of explosive dust (fuel)
inlet and/or outlet ducting. from the collector.
The chemical isolation system
creates a chemical barrier
that suppresses the explosion
within the ducting, reduces the
Explosion Venting
propagation of flame through
the ducting and minimizes
Explosion Vent
pressure increases within Designed to be the “weak” link of the vessel,
connected process equipment. explosion vents open when predetermined pressures
are reached inside the dust collector allowing the
overpressure and flame fronts to exit to a safe
Stinger Isolation Valve area. Explosion vents minimize damage to the
The purpose of the Stinger is to prevent a deflagration dust collector caused by overpressure created by a
(explosion) that could occur in the dust collector deflagration. Camfil APC’s standard explosion vents
from traveling back down the inlet pipe back into the are ATEX certified and NFPA compliant.
workspace/process.
Flameless Vent
Designed to install over a standard explosion
vent, the “FlamQuench SQ” extinguishes
the flame front exiting the vented area not
Detect and Suppress allowing it to exit the device. This allows
These systems protect the dust collector conventional venting to be accomplished
from ignition sources such as sparks or indoors where it could otherwise endanger
embers. It detects them and activates a personnel and/or ignite secondary explosions.
suppression system that extinguishes them
before they reach the collector. Chemical Suppression The chemical suppression system
Designed to react within milliseconds prevents expanding a deflagration by
of detecting an explosion, a chemical releasing a chemical agent.
suppression system is installed in the
collectors dirty air section.

OPTIONAL SAFETY FEATURES

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.

Blast Plate
A Blast Plate is a deflector mounted directly in front the explosion relief
area. The deflector is designed to restrict the flame length ejected from
the collector in the event of an explosion. For vessels that are not greater
than 706 cubic feet, the deflector is designed to reduce the axial (front-
centerline) safe distance by 50 percent.

Vertical Plenum
A plenum that is bolted to the dirty air section of the collector. The explosion vent is mounted to the top of the
plenum which effectively transitions the pressure and flame fronts from a horizontal to a vertical configuration. A
vertical configuration make it possible to explosion vent through a roof and/or direct the pressure and flame fronts
to a safe location as outlined in NFPA standards. In most cases, ducting and weather hoods are required to be
compliant with NFPA standards to protect the explosion vents from the elements and other debris. Access panels
are provided on the ducting so that easy inspection and/or replacement of the explosion vent is made possible
without removing the ducting and weather hood.

19
o & plants in Asia Pa & Middle East

Agents in Asia & Middle East

Tel: +86 512 5363 6111


We breathe
up to 15 kg of We spend up to
air per day* 90% of our life
*Typical for a sedentary lifestyle. indoors
Humans eat 1 kg food/day

15 kg
15 kg

Humans breathe 15 kg air/day

ISO16890

ISO 16890 - More than


the new standard 25,000,000
particles with
for air filters each breath

Take a Breath
Breathing air is essential for life.
It is the first thing we do when
we are born.
CAMFIL – A GLOBAL LEADER IN AIR
FILTERS AND CLEAN AIR SOLUTIONS.
For more than half a century, Camfil has been helping people
breathe cleaner air. As a leading manufacturer of premium clean
air solutions, we provide commercial and industrial systems for air
filtration and air pollution control that improve worker and equipment
productivity, minimize energy use, and benefit human health and
the environment. We firmly believe that the best solutions for our
customers are the best solutions for our planet, too. That’s why
every step of the way – from design to delivery and across
the product life cycle – we consider the impact of what we
do on people and on the world around us. Through a fresh
approach to problem-solving, innovative design, precise
process control and a strong customer focus we aim to
conserve more, use less and find better ways – so we
can all breathe easier.

The Camfil Group is headquartered in Stockholm,


Sweden, and has 3 manufacturing sites,
six R&D centres, local sales offices in 3
countries, and about , 00 employees
and growing. We proudly serve and
support customers in a wide variety
of industries and in communities
across the world. To discover
how Camfil can help you
to protect people,

As part of our program for continuous improvement, Camfil reserves the right to change specifications without notice.
processes and the
environment.

www.camfil.com
For further information please contact your nearest Camfil office.

You might also like