BS 8500 Concrete

BS 8500-1:2006 provides guidance on the selection of designated and standardized prescribed concrete for various applications in housing and construction. It includes tables detailing concrete types, strength classes, consistence classes, and specific requirements for different uses such as foundations, floors, and pavements. The document emphasizes the importance of selecting the appropriate concrete type based on application needs and handling conditions.

Uploaded by

8bk8z27vd2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
295 views3 pages

BS 8500 Concrete

BS 8500-1:2006 provides guidance on the selection of designated and standardized prescribed concrete for various applications in housing and construction. It includes tables detailing concrete types, strength classes, consistence classes, and specific requirements for different uses such as foundations, floors, and pavements. The document emphasizes the importance of selecting the appropriate concrete type based on application needs and handling conditions.

Uploaded by

8bk8z27vd2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

BS 8500-1:2006

Table A.13 Guidance on the selection of designated and standardized


prescribed concrete in housing and other applications
Application A), B) Designated Standardized Recommended
concrete prescribed consistence class
concrete
Unreinforced foundations B) and associated works requiring
DC-1 concrete
Blinding and mass concrete fill GEN1 ST2 S3 C)
Strip footings GEN1 ST2 S3 C)
Mass concrete foundations GEN1 ST2 S3 C)
Trench fill foundations GEN1 ST2 S4
Drainage works to give immediate support GEN1 ST2 S1
Other drainage works GEN1 ST2 S3 C)
Oversite below suspended slabs GEN1 ST2 S3 C)
Unreinforced foundations requiring DC-2 to DC-4 concrete B)
DC-2 FND2 N/A S3 C), D)


DC-2z FND2Z N/A S3 C), D)




DC-3 FND3 N/A S3 C), D)




"



DC-3z FND3Z N/A S3 C), D)
DC-4 FND4 N/A S3 C), D)
!

DC-4z FND4Z N/A S3 C), D)


DC-4m FND4M N/A S3 C), D)


General applications
Kerb bedding and backing GEN0 ST1 S1

Floors

House floors with no embedded metal (see Note 2 to 4.2.2)



• Permanent finish to be added, e.g. a screed or floating floor GEN1 ST2 S2
• No permanent finish to be added, e.g. carpeted GEN2 ST3 S2


Garage floors with no embedded metal GEN3 ST4 S2






Wearing surface: light foot and trolley traffic RC25/30 ST4 S2



Wearing surface: general industrial RC32/40 N/A S2


Wearing surface: heavy industrial E) RC40/50 N/A S2


Paving





House drives and domestic parking PAV1 N/A S2 C)


 

Heavy-duty external paving with rubber tyre vehicles E) PAV2 N/A S2 C), F)



A) Concrete containing embedded metal should be treated as reinforced.
 
B) See Table A.3 for designated concretes for reinforced foundations and reinforced concrete.


C) This is the default slump class for this designated concrete.


 


D) For trench fill, the recommended consistence class is S4.

E) For extreme applications, e.g. foundry floors and busy public roads, specialist advice should be sought.
F)



Depends on method of placing.


 

40 • © BSI 2006
 


BS 8500-1:2006

Table A.14 Summary of requirements for designated concretes A)


Concrete Min. Default Max. Min. cement or Cement and combination types
designation strength slump w/c ratio combination content
class class (kg/m3) for 20 mm
max. aggregate size
GEN0 C6/8 S3 — 120 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V
GEN1 C8/10 S3 — 180 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V
GEN2 C12/15 S3 — 200 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V
GEN3 C16/20 S3 — 220 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V
RC20/25 C20/25 S3 0.70 240 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V
RC25/30 C25/30 S3 0.65 260 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
RC28/35 C28/35 S3 0.60 280 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
RC30/37 C30/37 S3 0.55 300 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
RC32/40 C32/40 S3 0.55 300 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
RC35/45 C35/45 S3 0.50 320 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
<
RC40/50 C40/50 S3 0.45 340 CEM I, IIA, IIB-S, IIB-V, IIIA, IVB-V B)
+

>

RC40/50XF C40/50 S3 0.45 340 CEM I, IIA, IIB-S, IIB-V, IIIA


,(

E
'
PAV1 C25/30 C) S2 0.60 280 CEM I, IIA, IIB-S, IIB-V, IIIA
?
PAV2 C28/35 C) S2 0.55 300 CEM I, IIA, IIB-S, IIB-V, IIIA
D

0.55 320 IIB-V+SR, IIIA+SR, IIIB+SR, IVB-V


0.50 340 CEM I, SRPC, II-S, II-V, IIIA, IIIB
%

'

# '

FND2 C25/30 S3
@
0.45 360 IIA-L or LL U class 42,5
.

0.40 380 IIA-L or LL class 32,5


.
C

FND2Z C25/30 S3 0.55 320 All in Table A.6


,

'

0.50 340 IIIB+SR


,

B
'
FND3 C25/30 S3 0.45 360 IVB-V
>

0.40 380 IIB-V+SR, IIIA+SR, SRPC


-

'

FND3Z C25/30 S3 0.50 340 All in Table A.6


A

@
'
0.45 360 IIIB+SR
+

?
,
FND4 C25/30 S3 0.40 380 IVB-V
- >

(
0.35 380 IIB-V+SR, IIIA+SR, SRPC
FND4Z C25/30 S3 0.45 360 All in Table A.6
=

<

FND4M C25/30 S3 0.45 360 IIIB+SR


(

;
$

A) See BS 8500-2:2006, Clause 6 for the full set of requirements for designated concretes.
& :
B) Only if specifically permitted under 4.2.3a).
6
C) The concrete is required by BS 8500-2 to contain an air-entraining admixture to give a minimum air content by volume
9

4 7
of 3.0%, 3.5% or 5.5% with aggregate of 40 mm, 20 mm and 10 mm maximum aggregate size respectively at delivery.
8

4 7

'

- .

+ ,

% )

41
& '

© BSI 2006 •
# $
BS 8500-1:2006

Table A.15 Standardized prescribed concretes and indicative strengths


Standardized prescribed Strength class that may be Characteristic compressive cube strength
concrete assumed for structural design at 28 days that may be assumed for structural
design
N/mm2
ST1 C6/8 8
ST2 C8/10 10
ST3 C12/15 15
ST4 C16/20 20
ST5 C20/25 25

A.5 Selection of consistence


The consistence of fresh concrete should be suitable for the conditions
of handling and placing so that after compaction, concrete surrounds
all reinforcement, tendons and ducts and completely fills the
formwork. Table A.16 provides guidance on the consistence expressed
_

as slump [S(number)] and flow [F(number)] classes appropriate to


different uses. Where the concrete is laid on a slope, a lower slump class
a

OK

h
J
than that given in Table A.16 might be necessary.
b

K
Table A.16 Consistence suitable for different uses of in-situ concrete
Use of concrete Form of compaction Consistence class
H

F J

Normal-weight Lightweight
f
Q

Q
concrete concrete

O
Kerb bedding and backing Tamping S1 —
J

Floors and hand placed pavements Poker or beam vibration S2 S2


O

e
J

Strip footings S3 —
P
a

J
Mass concrete foundations S3 —
d

Blinding S3 —
Normal reinforced concrete in slabs, beams, Poker or beam vibration S3 S3
O

c
J

N O
walls and columns and/or tamping
b

P a
Sliding formwork construction S2 S2
K

Pumped concrete S3 F5
_

Vacuum processed concrete S3 S3


^
G

Trench fill S4 —
Self-weight compaction
In-situ piling S4 —
I ]

[
Z

Consistence should be specified by using one of the classes in


W Z
BS EN 206-1:2000, Table 3 to Table 6 or, in special cases, by a target
value. Where self-compacting concrete is required, guidance may be
V

V
obtained from specialist literature. For example, the classes in The
X

U
European Guidelines for self-compacting concrete – specification,
W

V
production and use [2] may be specified and that document cited for
U

conformity criteria and test methods.


S

O
It is normally the responsibility of the user of the fresh concrete to make
R
J

the selection of consistence and inform the specifier of the


P Q
requirements. The specifier should add this requirement to the
N O

M
specification.

H L

42 • © BSI 2006
I J