The document provides a detailed product data sheet for the TeSys Deca thermal overload relay (LRD05), which is designed for motor protection with a thermal overload adjustment range of 0.63 to 1 A and conforms to Class 10A standards. It includes specifications such as compatibility with various devices, environmental conditions, mechanical robustness, and certifications. Additionally, it outlines packaging details, warranty information, and environmental sustainability efforts by Schneider Electric.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views8 pages

Schneider Electric TeSys Deca Overload Relays LRD05

The document provides a detailed product data sheet for the TeSys Deca thermal overload relay (LRD05), which is designed for motor protection with a thermal overload adjustment range of 0.63 to 1 A and conforms to Class 10A standards. It includes specifications such as compatibility with various devices, environmental conditions, mechanical robustness, and certifications. Additionally, it outlines packaging details, warranty information, and environmental sustainability efforts by Schneider Electric.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Product data sheet

Specifications

TeSys Deca, thermal overload relay,


0.63 to 1 A, class 10A
LRD05

Product availability: Stock - Normally stocked in distribution


facility

Main
Range TeSys
TeSys Deca

product name TeSys LRD


TeSys Deca

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or Component Type Differential thermal overload relay

Device short name LRD

Relay application Motor protection

Product Compatibility LC1D25


LC1D38
LC1D12
LC1D32
LC1D18
LC1D09

Network type AC
DC

Thermal overload class Class 10A IEC 60947-4-1

Thermal protection adjustment 0.63…1 A


range
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1

Complementary
Network Frequency 0...400 Hz

Mounting support Plate, with specific accessories


Rail, with specific accessories
Under contactor

Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1

Auxiliary contact composition 1 NO + 1 NC

[Ith] conventional free air thermal 5 A signalling circuit


current
Permissible current 3 A 120 V AC-15 signalling circuit
0.22 A 125 V DC-13 signalling circuit

[Ue] rated operational voltage 690 V AC 0...400 Hz power circuit IEC 60947-4-1

Associated fuse rating 4 A gG for signalling circuit


4 A BS for signalling circuit

[Uimp] rated impulse withstand 6 kV


voltage
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0

Control type Red push-button stop


Blue push-button reset

Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.

Jul 2, 2025 1
Temperature compensation -4…140 °F (-20…60 °C)

Connections - terminals Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible
without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with
cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without
cable end
Power circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without
cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with
cable end
Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without
cable end

Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals

Height 2.6 in (66 mm)

Width 1.8 in (45 mm)

Depth 2.8 in (70 mm)

Net Weight 0.273 lb(US) (0.124 kg)

Environment
Climatic withstand IACS E10

IP degree of protection IP20 conforming to IEC 60529

Ambient air temperature for -4…140 °F (-20…60 °C) without derating IEC 60947-4-1
operation
Ambient Air Temperature for -76…158 °F (-60…70 °C)
Storage
Flame retardance V1 conforming to UL 94

Mechanical robustness Vibrations6 Gn IEC 60068-2-6


Shocks15 Gn for 11 ms IEC 60068-2-7

Dielectric strength 1.89 kV 50 Hz IEC 60947-1

Standards EN/IEC 60947-4-1


EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495

Product Certifications IEC


UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCA

Ordering and shipping details


Category US10I1222347

Discount Schedule 0I12

GTIN 3389110346756

Returnability Yes

Country of origin FR

2 Jul 2, 2025
Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 1.97 in (5 cm)

Package 1 Width 3.07 in (7.8 cm)

Package 1 Length 3.50 in (8.9 cm)

Package 1 Weight 4.9 oz (139 g)

Unit Type of Package 2 S02

Number of Units in Package 2 24

Package 2 Height 5.91 in (15 cm)

Package 2 Width 11.81 in (30 cm)

Package 2 Length 15.75 in (40 cm)

Package 2 Weight 8.305 lb(US) (3.767 kg)

Unit Type of Package 3 P06

Number of Units in Package 3 384

Package 3 Height 31.50 in (80 cm)

Package 3 Width 31.50 in (80 cm)

Package 3 Length 23.62 in (60 cm)

Package 3 Weight 150.770 lb(US) (68.388 kg)

Contractual warranty
Warranty 18 months

Jul 2, 2025 3
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg CO2 eq, Total Life cycle) 13

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard Yes

Packaging without single use plastic No

EU RoHS Directive Compliant

SCIP Number 224fb0ea-2bc1-482e-b6b4-c1bdd9779659

REACh Regulation REACh Declaration

WARNING: This product can expose you to chemicals


including: Antimony oxide & Antimony trioxide, which is
California proposition 65
known to the State of California to cause cancer. For
more information go to www.P65Warnings.ca.gov

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

Take-back No

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins.

4 Jul 2, 2025
Product data sheet LRD05

Dimensions Drawings

Approximate Dimensions

Jul 2, 2025 5
Product data sheet LRD05

Image of product / Alternate images

Alternative

6 Jul 2, 2025
Product data sheet LRD05

Jul 2, 2025 7
Product data sheet LRD05

8 Jul 2, 2025

You might also like