EMS Reports ACP Processor Error For SAS Shelf ACP Processor

The document addresses an error reported by the EMS regarding the ACP Processor for a SAS shelf, indicating critical faults and communication issues within the ACP. It provides troubleshooting steps including checking firmware, rebooting the service processor, and adjusting ACP settings. Users are advised to contact NetApp Technical Support for further assistance if issues persist.

Uploaded by

leeweishin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views3 pages

EMS Reports ACP Processor Error For SAS Shelf ACP Processor

The document addresses an error reported by the EMS regarding the ACP Processor for a SAS shelf, indicating critical faults and communication issues within the ACP. It provides troubleshooting steps including checking firmware, rebooting the service processor, and adjusting ACP settings. Users are advised to contact NetApp Technical Support for further assistance if issues persist.

Uploaded by

leeweishin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

EMS reports ACP Processor error for SAS shelf ACP processor

https://kb.netapp.com/onprem/ontap/hardware/EMS_reports_ACP_Processor_error_for_SAS_shelf_A…
Updated: Wed, 27 Mar 2024 11:33:17 GMT

Applies to
• Alternate control path (ACP)
• Service Processor (SP)
• Baseboard Management Controller(BMC)

Issue
• Error is reported on the IOM fixing on motherboard
• EMS reports Call home for SHELF_FAULT and ACP Processor error for SAS shelf ACP
processor

[?] Tue Mar 23 04:37:00 JST [cluster-01: dsa_worker3:


ses.status.ACPError:critical]: DS2126 (S/N SHJSGXXXXXXXXXX) shelf 0 on

'NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations
provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations
provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or 1
techniques herein is a customers responsibility and depends on the customers ability to evaluate and integrate them into the customers operational
environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this
document.'
channel 0a ACP Processor error for SAS shelf ACP processor 1: critical
status ; Alternate Control Path hardware failed This module is on the rear
of the shelf at the top left, on shelf module A.
[?] Tue Mar 23 04:37:00 JST [cluster-01: monitor:
monitor.globalStatus.critical:critical]: Disk shelf fault.
[?] Tue Mar 23 04:37:09 JST [cluster-01: statd:
monitor.shelf.fault:critical]: Fault reported on disk storage shelf
attached to channel 0a. Check fans, power supplies, disks, and temperature
sensors.
[?] Tue Mar 23 04:37:09 JST [cluster-01: statd:
callhome.shlf.fault:error]: Call home for SHELF_FAULT

• storage show fault reports Alternate Control Path is critical

Vendor Unique Element 85-IOM6E: (ACP)


Element Status Status Bytes Status Descriptions
1 [IOM6E A] : CRITICAL 02,00,00,40 FAIL
2 [IOM6E B] : OK 01,00,00,00

Vendor Unique Element 85-IOM12E: (ACP)


Element Status Status Bytes Status Descriptions
1 [IOM12E A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12E B] : OK 01,18,00,00 NO ACPP, INBACP

Vendor Unique Element 85-IOM12E: (ACP)


Element Status Status Bytes Status Descriptions
1 [IOM12E A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12E B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL

Vendor Unique Element 85-IOM12: (ACP)


Element Status Status Bytes Status Descriptions
1 [IOM12 A] : OK 01,18,00,00 NO ACPP, INBACP
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL

Cause

ACP internal communication issues

© 2023 NetApp.No part of this document covered by copyright may be reproduced in any form or by any means—graphic, electronic, or mechanical,
including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner. For more
information, see Legal Notices. 2
Solution
1. Check your SP/BMC FW and upgrade if not on the latest, FW may solve your issue. System Firmware &
Diagnostics Download
2. Check whether the ACP settings of all nodes are consistent
3. Reboot the SP/BMC of effected node

Cluster::> system service-processor reboot-sp -node <node_name>

3. Disable ACP

Cluster::> storage shelf acp configure -is-enabled false

4. Re-enable ACP

Cluster::> storage shelf acp configure -is-enabled true -channel <in-band


or out-of-band>

5. Please contact NetApp Technical Support or log into the NetApp Support Site to create a case. Reference
this article for further assistance.

Additional Information
• SU383
• In-Band ACP Setup and Support

© 2023 NetApp.No part of this document covered by copyright may be reproduced in any form or by any means—graphic, electronic, or mechanical,
including photocopying, recording, taping, or storage in an electronic retrieval system—without prior written permission of the copyright owner. For more
information, see Legal Notices. 3