0% found this document useful (0 votes)
14 views10 pages

6 U.S (1)

The document outlines critical notes and instructions for the engineer in charge during the execution of a construction project, emphasizing the need for thorough study of architectural and structural drawings. It specifies concrete mix requirements, reinforcement details, and dimensions for various structural components, along with guidelines for formwork and curing. Additionally, it highlights the importance of reporting ambiguities and adhering to written dimensions to ensure project integrity.

Uploaded by

xhireofficial
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views10 pages

6 U.S (1)

The document outlines critical notes and instructions for the engineer in charge during the execution of a construction project, emphasizing the need for thorough study of architectural and structural drawings. It specifies concrete mix requirements, reinforcement details, and dimensions for various structural components, along with guidelines for formwork and curing. Additionally, it highlights the importance of reporting ambiguities and adhering to written dimensions to ensure project integrity.

Uploaded by

xhireofficial
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH

DUE RESPONSIBILITY BY ENGINEER IN -CHARGE DURING EXECUTION OF


THE PROJECT
2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/
1 2 3 4 5 6 7 8 9 10 11 STRUCTURAL DRAWINGS OF THE BUILDING BEFORE EXECUTION AND
AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO S.E./SR.
ARCHITECT/SR. STR.ENGR.FOR NECESSARY ACTION.
63'-8" 3) ALL DIMENSIONS ARE IN mm
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4" 4) ALL DESIGN MIX CONCRETE OF GRADE M25 HAVING MINIMUM CEMENT
CONTENT 300 kg/m3, Max W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.
S1 S S1 S1 S S1 7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS,
INCLUDING LINKS) FOR FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND
H SLAB = 30.

5'-9"
5'-9"
8) d = DIA OF MAIN BAR.
R.C.C SLAB AT P.L

R.C.C SLAB AT P.L


9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEPTH OF BEAM / SLAB
5'-6"

5'-6"
10) Ds = OVERALL DEPTH OF SLAB.
5'-9" 6'-3" 11) T = EDGE THICKNESS OF SLAB.
6'-3" 6'-3" 6'-4" 5'-9" 12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.

3'

3'
G 13) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
14) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
X X S X X 15) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 33X BAR
7'-10" DIA.
6'-10"

6'-10"
16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA EQUALLY
DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB > 750 FOR STRAIGHT
BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB THICKNESS, WHICHEVER IS
LESS.
F 17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING
DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN NOTE (14 ).

6'-9"

6'-9"
6'-9"

6'-9"
S PB S S S PB S 18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF ANY,
5'-5"

5'-5"
5'-9" SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C. PATNA.
19) GRID LINE SHOWS CL OF WALLS.
S S
20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS No. 501,
2'-9"

Sl.No.-500, DATED-14-12-2010.
E

2'-9"
S S
R.C.C SLAB AT P.L

R.C.C SLAB AT P.L


1) TYPE OF STR.- LOAD BEARING
5'-9" 7'-3" 7'-10" 7'-3"

49'-7"
2) LOAD -G+2
3) SEISMIC ZONE - V
12'-4"

12'-4"
50'-5"

4) NET ALLOWABLE B.P= 10 T/m AT A DEPTH OF 2.0 M


5'-9"
7'-3"
7'-3"

S S S1 S1 S S
D

7'-3"

7'-3"
PB PB
CF3
5'-5"

5'-5"
5'-9"
5'-9" BIHAR POLICE BUILDING CONSTRUCTION
S
2'-9"

C CORPORATION, B.M.P. - 5, PATNA

2'-9"
S S S
7' 7'-3" 7'-3"
JOB TITLE :
9'-8"

9'-8"
7'
TIe beam SHEET TITLE :
S S1 At P.L
B
5'-9" S 5'-9"
X CF1 X
CF1 CF2 S1
4'-5"

4'-5"
6'

6'

CF2 DRG. NO. - DATE -


S1 R.C.C SLAB AT P.L S R.C.C SLAB AT P.L
2'-6"

2'-6"

2'-6"

A S.L NO. -
SHEET NO. - 1 / 9
5'-9"

5'-9"
X S1 S1 S X S1 FAHAD NAQUI
ARCH. D'Man SCALE:- NOT TO SCALE

M. SAHU
STR.CONSULTANT.

FOUNDATION LAYOUT PLAN

S. E. CHIEF ENGINEER
ARCHITECT
4''Th.R.C.C. BAND AT P.L.
P.L. 4''Th.R.C.C. BAND AT P.L. 4''Th.R.C.C. BAND AT P.L. 4''Th.R.C.C. BAND AT P.L.
P.L. P.L. P.L.
NOTES & INSTRUCTIONS:-
AS PER SITE AS PER SITE AS PER SITE
AS PER SITE 1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH DUE RESPONSIBILITY BY
ENGINEER IN -CHARGE DURING EXECUTION OF THE PROJECT.
G.L. G.L. G.L. G.L. 2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/ STRUCTURAL DRAWINGS OF
THE BUILDING BEFORE EXECUTION AND AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO
C.E./SR. ARCHITECT/SR.STRU.ENGR.FOR NECESSARY ACTION.
3) ALL DIMENSIONS ARE IN mm
4) ALL DESIGN MIX CONCRETE SHALL BE OF GRADE M20 HAVING MINIMUM CEMENT CONTENT 300 kg/m3, Max
W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
# 10@7"c/c (Dist.) #10 @ 7" c/c 5) # INDICATES HYSD BARS OF GRADE Fe 500, CONFORMING TO I.S. 1786.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND COMPACTED PROPERLY USING MECHANICAL
6'-6" #12 @ 5" c/c #10@7" c/c #10@8" c/c
14" #12 @ 5" c/c (Main) 14'' #12 @ 6" c/c #12 @ 7" c/c
VIBRATORS.
7) DURATION OF CURING SHALL BE NOT LESS THAN SEVEN DAYS.
6'-6"4'' 6'-6" 6'-6"
4" 12'' 10'' 8) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS, INCLUDING LINKS) FOR
2" FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND SLAB = 30mm.
10'' 14" R.C.C. M20 14'' R.C.C. M20 3"
9) d = DIA OF MAIN BAR.
10'' 12'' R.C.C. M20 10'' R.C.C. M20 10) Ld = EFFECTIVE DEVELOP LENGTH.
9'' 8''
11) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
3'' 3" Brick Flat Soling 3" 3" Brick Flat Soling 3" 3" Brick Flat Soling 3" 3" Brick Flat Soling 12) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
13) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 39X BAR DIA FOR M20.
6'' 6" Local Sand Filling 6" 6" Local Sand Filling 6" 6" Local Sand Filling 6" 6" Local Sand Filling 14) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WEB AREA EQUALLY DISTRIBUTED ON BOTH FACES
WHERE DEPTH OF WEB > 750 FOR STRAIGHT BEAMS IN FLEXURE ONLY
7'-9'' 7'-3"/7'-0'' 6'-9" 5'-9"/6'-0" @ <300S c/c OR WEB THICKNESS, WHICHEVER IS LESS.
15) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING DEPTH OF CROSS SECTION > 450
SECTION OF SECTION OF SECTION OF SECTION OF SHALL BE SAME AS IN NOTE (17 ).
16) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED AMBIGUITY, IF ANY, SHALL BE BROUGHT TO THE
WALL FOOTING 4 - #10 Thr. WALL FOOTING WALL FOOTING WALL FOOTING NOTICE OF THE SR. ARCHITECT / SR. STRU. ENG. ( M ) B.P.B.C.C. PATNA FOR NECESSARY ACTION.
17) THE FORM WORK FOR CONCRETING SHALL BE SUCH THAT IT MAY REMAIN
SUFFICIENTLY RIGID DURING PLACING AND COMPACTION OF CONCRETE AND SHALL BE SUCH AS TO
# 8 @ 4" 4''Th. PREVENT LOSS OF CEMENT / SLURRY FROM THE CONCRETE.
P.L. SIZE - 10"X10" (S) to 6"c/c P.L. 18) THE FROM WORKS FOR (SPAN >3.5m) BEAMS & SLAB SHALL BE SO ASSEMBLED AS TO PROVIDE CAMBER
250 R.C.C. AS FOLLOWERS:-
AS PER SITE #8@4''to6''c/c # 8 @ 4" to 6"c/c 4''Th.R.C.C. BAND AT P.L. 4''Th.R.C.C. BAND AT P.L. BAND a) CAMBER FOR BEAMS/SLAB SHALL BE 1 IN 250 OF THE SPAN OR 4MM/ METER OF SPAN AT THE CENTRAL
POINT.
P.L. P.L. AS PER SITE
G.L.
#12-4 Nos. 5 - #10 Thr. AT P.L. b) FOR CANTILEVER BEAMS /SLAB CAMBER AT THE FREE END SHALL BE SPAN /50 OF THE PROJECTED
4 - #10 Thr. G.L. LENGTH.
250 AS PER SITE AS PER SITE 19) a) REMOVAL OF PROPS UNDER R.C.C. SLAB SHALL NOT BE ALLOWED BEFORE 14 DAYS (MINIMUM).
b) REMOVAL OF PROPS UNDER BEAMS & ARCH. SPANNING UP TO 6m SHALL NOT BE ALLOWED BEFORE 14
Main Rein.of Corresponding G.L. G.L. DAYS (MINIMUM).
6'-6" D Footing both way SECTION OF TB 5" c) REMOVAL OF PROPS UNDER BEAMS & ARCH. SPANNING OVER 6m SHALL NOT BE ALLOWED BEFORE 21
DAYS.
D R.C.C. M20 20) IN FRAME STRUCTURE ALL EXTERNAL & STAIR WALL SHALL BE 10" THICK AND INTERNAL WALL SHALL
D 2 - #10 Thr.+
3" 3" Brick Flat Soling # 8 - 6 Nos.(Dist.) # 8 - 6 Nos.(Dist.) BE 125 THICK EXCEPT MENTIONED.
2 - #10 extra 21) EXPANSION JOINT SHALL BE PROVIDED AS PER DRG. NO.-357, SL NO.-356, DT- 24-07-2015, COMMUNICATED
6" 6" Local Sand Filling 6'-6" 8" #10 @ 7" c/c (Main) 6'-6" #10 @ 7" c/c (Main) 6'-6" VIDE C.E.'S LETTER NO.-3650 DT-25-07-2015 AS PER LOCATION MARKED IN THE ARCH./STRU. DRG.
5 - #10 Thr. 2" 22) PARAPET WALL SHALL BE STIFFENED WITH STIFFENER/ COLUMN PROJECTING FROM
# 8 @ 4" 8" R.C.C. M20 R.C.C. M20 6"
ROOF AND BY PROVIDING A R.C.C. BAND 3" THICK AT THE TOP OF PARAPET WALL.
DETAILS OF STIFFNER (S ) 6" 23) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWING No.- ------ Sl. No. ----------
(SECTION - K -K) 250 to 6"c/c 2'-7" 6" 6"
3"
DATE - ----------
3" 3" Brick Flat Soling 3" 3" Brick Flat Soling
6" 6" Local Sand Filling 6" 6" Local Sand Filling 6" B) DESIGN PARAMETERS
4 - #10 Thr. 3'-0" 2'-9"
width of footing 250 2'-6''
SECTION OF R.C.C
#12 @ 6" c/c C OF
L COL.
SLAB AT P.L
SECTION OF SECTION OF SECTION OF
Bothways
SECTION OF PB WALL FOOTING WALL FOOTING WALL FOOTING
Section at-xx
BAR ALONG THIS LINE
AS PER WIDTH OF
BAR ALONG THIS LINE

FOOTING

K K
G.F.C.
CL OF COL.

4''Th.R.C.C. BAND AT P.L. 4''Th.R.C.C. BAND AT P.L.


4''Th.R.C.C. BAND AT P.L.
P.L. P.L.(AS PER SITE) P.L. P.L.(AS PER SITE) P.L. BIHAR POLICE BUILDING CONSTRUCTION
AS PER WIDTH OF
FOOTING
P.L.(AS PER SITE)
CORPORATION, B.M.P. - 5, PATNA
AS PER SITE AS PER SITE AS PER SITE
TYPICAL DETAILS OF FOOTING (S )
G.L. G.L. G.L.
PROJECT:-
# 10 - 8 Nos. (DIST.) # 10 - 8 Nos. (DIST.) # 10 - 8 Nos. (DIST.) 6 US QUARTER FOR
P.L. SIZE - 10"X12"(S1)
#10@8"c/c (MAIN) #10@8"c/c (MAIN) #10@8"c/c (MAIN)
BIHAR SWAVIMAN SPECIAL ARMS
AS PER SITE #8@4" to 6" c/c 6'-6" 6'-6" 6'-6" POLICE FORCE AT - VALMIKINAGAR,BIHAR
G.L. R.C.C. M20 R.C.C. M20 R.C.C. M20
#12-8 Nos.
3" Thk. Brick 3" Thk. Brick 3" Thk. Brick
9'' 9'' 9''
#12 @ 6" c/c Bothways 3"
Flat Soling
3"
Flat Soling
3"
Flat Soling DETAILS OF FOUNDATION
12" 6" Thk. Local 6" Thk. Local 6" Thk. Local
6'-6" 6" 6" 6"
4" Sand Filling Sand Filling Sand Filling
8" 12" R.C.C. M20
as per wide of footing as per wide of footing as per wide of footing
3" 3" Brick Flat Soling #10@8"c/c (MAIN) #10@8"c/c (MAIN) #10@8"c/c (MAIN) DRG. NO. - DATE -
6" 6" Local Sand Filling
SECTION OF CF1 # 10 - 8 Nos. (DIST.) SECTION OF CF2 # 10 - 8 Nos. (DIST.) SECTION OF CF3 # 10 - 8 Nos. (DIST.)
4'-0''
SHEET NO. - 2 / 9
DETAILS OF COLUMN (S1) S.L NO. -
(SECTION - L -L) SCALE:- NOT TO SCALE

#12 @ 6" c/c CL OF COL.


Bothways
CF1 CF2 CF3
AS PER WIDTH OF CORRESPONDING

BAR ALONG THIS LINE


BAR ALONG THIS LINE

STRUCTURAL
L L
FOOTING

A. E. DESIGN A. E. DESIGN CONSULTANT

CL OF COL.
S1 S1 S1 S1 S1 S1
AS PER WIDTH OF CORRESPONDING
FOOTING

TYPICAL DETAILS OF FOOTING (S1) DETAILS OF FOOTING CF1(10'-4"x7'-0") DETAILS OF FOOTING CF2(10'-4"x7'-3") DETAILS OF FOOTING CF3(10'-4"x7'-3")
ARCHITECT S. E. CHIEF ENGINEER
1 2 3 4 5 6 7 8 9 10 11 1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH
DUE RESPONSIBILITY BY ENGINEER IN -CHARGE DURING EXECUTION OF
THE PROJECT
63'-8" 2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4" STRUCTURAL DRAWINGS OF THE BUILDING BEFORE EXECUTION AND
AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO S.E./SR.
ARCHITECT/SR. STR.ENGR.FOR NECESSARY ACTION.
3) ALL DIMENSIONS ARE IN mm
S1 S S1 S1 S S1 4) ALL DESIGN MIX CONCRETE OF GRADE M25 HAVING MINIMUM CEMENT
CONTENT 300 kg/m3, Max W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
H 5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.

R.C.C SLAB AT P.L

R.C.C SLAB AT P.L


7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS,
5'-6"

5'-6"
INCLUDING LINKS) FOR FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND
SLAB = 30.
8) d = DIA OF MAIN BAR.
G 9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEPTH OF BEAM / SLAB
10) Ds = OVERALL DEPTH OF SLAB.
S 11) T = EDGE THICKNESS OF SLAB.
12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
6'-10"

6'-10"
13) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
14) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
15) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 33X BAR
DIA.
F 16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA EQUALLY

S PB S S S PB S DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB > 750 FOR STRAIGHT
BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB THICKNESS, WHICHEVER IS
5'-5"

5'-5"
LESS.
17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING
DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN NOTE (14 ).

E S S 18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF ANY,


SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C. PATNA.
S S
R.C.C SLAB AT P.L

R.C.C SLAB AT P.L


19) GRID LINE SHOWS CL OF WALLS.
20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS No. 501,
Sl.No.-500, DATED-14-12-2010.

49'-7"
12'-4"

12'-4"
50'-5"

1) TYPE OF STR.- LOAD BEARING


2) LOAD -G+2
3) SEISMIC ZONE - V
4) NET ALLOWABLE B.P= 10 T/m AT A DEPTH OF 2.0 M

S S S1 S1 S S
D
PB PB
5'-5"

5'-5"
C S
S S S
BIHAR POLICE BUILDING CONSTRUCTION
CORPORATION, B.M.P. - 5, PATNA
9'-8"

9'-8"
JOB TITLE :
TIe beam
S S1 At P.L S1
B S 5'-9"
X SHEET TITLE :
4'-5"

4'-5"
S1 R.C.C SLAB AT P.L S R.C.C SLAB AT P.L
S1
A DRG. NO. - DATE -

5'-9"
X S
S1 S1
SHEET NO. - 3 / 9
S.L NO. -
FAHAD NAQUI
ARCH. D'Man SCALE:- NOT TO SCALE
4- #12 Thr. 8- #12 Thr.

# 8 @ 4" # 8 @ 4"
10" to 6"c/c to 6"c/c M. SAHU
12" STR.CONSULTANT.

10" 10"
STIFFENER (S) STIFFENER (S1) ARCHITECT
S. E. CHIEF ENGINEER
3- #10 Thr.
1 2 3 4 5 6 7 8 9 10 11
63'-8" #8@6"c/c

6"
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4"

H 3- #10 Thr.
10"
AT Lintel Level

AT Lintel Level
L7 L6 L7 L6
5'-6"

SECTION AT L1/L6 / L7
LB2
G 2 - #12 Thr.+
2 - #12 extra
6'-10"

R.C.C SLAB

R.C.C SLAB

15"
F #10 @ 5"c/c

5"
L4 L1 L1 LB2 LB2 L1 L1 L4 L5
L5
5'-5"

#8 @ 3Nos
4- #12 Thr.
10"

2'-7"
E SECTION AT -LB1
L3 L3 With Chajjah
Lintel Level

Lintel Level
12'-4"
50'-5"

# 8 @ 4" to 6"c/c
R.C.C SLAB AT

R.C.C SLAB AT
5 - #10 Thr.

9' 5"
D
LB2-10"x12" LB2-10"x12" 5 - #10 Thr.
L7 L7
5'-5"

L5 L5
2'-7"
L4 UP L4
C SECTION OF R.C.C SLAB
L3 L3
AT LINTEL LEVEL.
L6 L6
9'-8"

3 - #12 Thr.+ BIHAR POLICE BUILDING CONSTRUCTION


2 - #12 extra CORPORATION, B.M.P. - 5, PATNA
LB1-10"x15" LB1-10"x15" JOB TITLE :
B

12"
4'-5"

7'
Z
R.C.C SLAB AT Lintel Level LB1-10"x15" R.C.C SLAB AT Lintel Level
A 4- #12 Thr.
SHEET TITLE:
LB1-10"x15" 10"
Z SECTION AT -LB2
LINTEL & LINTEL BEAM PLAN DRG. NO. - DATE -
Bar of Floor Slab
2- #10 Thr. 10'-6" level.
2- #10 Thr. SHEET NO. - 4 / 9
S.L NO. -
FAHAD NAQUI

9"
#8 @ 3Nos ARCH. D'Man SCALE:- NOT TO SCALE
3- #8
6"
6"

Floor Beam
15"
#10@ 5"C/C #10 @ 100c/c
BEAM
2- #10 Thr. 3- #10 Thr. Level 8'-6" M. SAHU
5" 10" 10" STR.CONSULTANT
#8 @ 3Nos
SECTION AT L3 / L4 SECTION AT L5 Details of Chajjah TRIPICAL BEAM SECTION
SECTION AT Z-Z

ARCHITECT S. E. CHIEF ENGINEER


1 2 3 4 5 6 7 8 9 10 11
63'-8" 1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH
DUE RESPONSIBILITY BY ENGINEER IN -CHARGE DURING EXECUTION OF
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4"
THE PROJECT
2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/
STRUCTURAL DRAWINGS OF THE BUILDING BEFORE EXECUTION AND
H AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO S.E./SR.
ARCHITECT/SR. STR.ENGR.FOR NECESSARY ACTION.
5'-6"

3) ALL DIMENSIONS ARE IN mm


4) ALL DESIGN MIX CONCRETE OF GRADE M25 HAVING MINIMUM CEMENT
CONTENT 300 kg/m3, Max W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
G 5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.
7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS,
S3 S5 S5 S3 INCLUDING LINKS) FOR FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND
6'-10"

W1 S5 S5 W1
SLAB = 30.
8) d = DIA OF MAIN BAR.
9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEPTH OF BEAM / SLAB
10) Ds = OVERALL DEPTH OF SLAB.
F 11) T = EDGE THICKNESS OF SLAB.
SUNKEN SUNKEN

10"x10"

10"x10"
12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
6"x18"

6"x18"
FB3

FB3
SLAB FB2 SLAB

FB2
13) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
5'-5"

14) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
S6 S6 15) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 33X BAR
DIA.
E 16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA EQUALLY
FB1-10"x18" FB1-10"x18" DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB > 750 FOR STRAIGHT
BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB THICKNESS, WHICHEVER IS
S1 S1 LESS.
17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING
DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN NOTE (14 ).
12'-4"

S3 S3 18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF ANY,


50'-5"

SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C. PATNA.


19) GRID LINE SHOWS CL OF WALLS.
3 - #16 Thr. 20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS No. 501,
Sl.No.-500, DATED-14-12-2010.

D 2 - #12 extra
SUNKEN SUNKEN 1) TYPE OF STR.- LOAD BEARING

6"x18"
6"x18"

10"x10"
10"x10"

FB3
FB3

SLAB
5'-5"

SLAB

18"
8mm@4"to6"c/c 2) LOAD -G+2

FB2
FB2

S6 UP S6 3) SEISMIC ZONE - V
4) NET ALLOWABLE B.P= 10 T/m AT A DEPTH OF 2.0 M
C
FB1-10"x18" FB1-10"x18"
S4 S4 10"
3- #16 Thr.
9'-8"

S2 S2 SECTION AT -FB1
2 - #10 Thr.+
B 2 - #10 extra
4'-5"

Z S5 7'
S5

10"
W1
A W1
8mm@4"to6"c/c

Z
4- #10 Thr.
10"

SECTION AT -FB2

10'-6" level.
2 - #12 Thr.
9"

0.1L1 0.3L1 0.3L 2 0.3L1 0.3L 2 0.3L1 #8 @ 3Nos

18"
8mm@4"to6"c/c
15"

Floor Beam #10 @ 100c/c


0.15L1 0.25L 1 0.25L2 0.25L 1 0.25L2 0.25L 1
Level 8'-6"
L1 L2 L3 10"
#8 @ 3Nos

2- #12 Thr.
TYPICAL SECTION OF SLAB TRIPICAL BEAM SECTION 6"
SECTION AT Z-Z
SECTION AT -FB3
1 2 3 4 5 6 7 8 9 10 11
63'-8" 1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH
DUE RESPONSIBILITY BY ENGINEER IN -CHARGE DURING EXECUTION OF
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4"
THE PROJECT
2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/
STRUCTURAL DRAWINGS OF THE BUILDING BEFORE EXECUTION AND
H AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO S.E./SR.
ARCHITECT/SR. STR.ENGR.FOR NECESSARY ACTION.
5'-6"

3) ALL DIMENSIONS ARE IN mm


4) ALL DESIGN MIX CONCRETE OF GRADE M25 HAVING MINIMUM CEMENT
CONTENT 300 kg/m3, Max W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
G 5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.
7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS,
S3 S5 S5 S3 INCLUDING LINKS) FOR FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND
6'-10"

W1 S5 S5 W1
SLAB = 30.
8) d = DIA OF MAIN BAR.
9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEPTH OF BEAM / SLAB
10) Ds = OVERALL DEPTH OF SLAB.
F 11) T = EDGE THICKNESS OF SLAB.
SUNKEN SUNKEN

10"x10"

10"x10"
12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
6"x18"

6"x18"
FB3

FB3
SLAB FB2 SLAB

FB2
13) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
5'-5"

14) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
S6 S6 15) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 33X BAR
DIA.
E 16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA EQUALLY
FB1-10"x18" FB1-10"x18" DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB > 750 FOR STRAIGHT
BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB THICKNESS, WHICHEVER IS
S1 S1 LESS.
17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING
DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN NOTE (14 ).
12'-4"

S3 S3 18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF ANY,


50'-5"

SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C. PATNA.


19) GRID LINE SHOWS CL OF WALLS.
3 - #16 Thr. 20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS No. 501,
Sl.No.-500, DATED-14-12-2010.

D 2 - #12 extra
SUNKEN SUNKEN 1) TYPE OF STR.- LOAD BEARING

6"x18"
6"x18"

10"x10"
10"x10"

FB3
FB3

SLAB
5'-5"

SLAB

18"
8mm@4"to6"c/c 2) LOAD -G+2

FB2
FB2

S6 UP S6 3) SEISMIC ZONE - V
4) NET ALLOWABLE B.P= 10 T/m AT A DEPTH OF 2.0 M
C
FB1-10"x18" FB1-10"x18"
S4 S4 10"
3- #16 Thr.
9'-8"

S2 S2 SECTION AT -FB1

2 - #10 Thr.+
B 2 - #10 extra
4'-5"

Z S5 7'
S5
W1
A

10"
W1
8mm@4"to6"c/c

Z
4- #10 Thr.
10"

SECTION AT -FB2

10'-6" level.
2 - #12 Thr.
9"

0.1L1 0.3L1 0.3L 2 0.3L1 0.3L 2 0.3L1 #8 @ 3Nos

18"
8mm@4"to6"c/c
15"

Floor Beam #10 @ 100c/c


0.15L1 0.25L 1 0.25L2 0.25L 1 0.25L2 0.25L 1
Level 8'-6"
L1 L2 L3 10"
#8 @ 3Nos

2- #12 Thr.
TYPICAL SECTION OF SLAB TRIPICAL BEAM SECTION 6"
SECTION AT Z-Z
SECTION AT -FB3
1 2 3 4 5 6 7 8 9 10 11
63'-8" 1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE FOLLOWED WITH
DUE RESPONSIBILITY BY ENGINEER IN -CHARGE DURING EXECUTION OF
13'-4" 2'-3" 8'-4" 3'-7" 3'-11" 3'-11" 3'-7" 8'-4" 2'-3" 13'-4"
THE PROJECT
2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE ARCHITECTURAL/
STRUCTURAL DRAWINGS OF THE BUILDING BEFORE EXECUTION AND
H AMBIGUITY IF ANY NOTICED BY HIM SHALL BE REPORTED TO S.E./SR.
ARCHITECT/SR. STR.ENGR.FOR NECESSARY ACTION.
5'-6"

3) ALL DIMENSIONS ARE IN mm


4) ALL DESIGN MIX CONCRETE OF GRADE M25 HAVING MINIMUM CEMENT
CONTENT 300 kg/m3, Max W/C = 0.5 FOR COARSE AGGREGATE 20 mm SIZE.
G 5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.
7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL REINFORCEMENTS,
S3 S5 S5 S3 INCLUDING LINKS) FOR FOUNDATION = 50, COLUMN = 40, BEAM = 30 AND
6'-10"

W1 S5 S5 W1
SLAB = 30.
8) d = DIA OF MAIN BAR.
9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEPTH OF BEAM / SLAB
10) Ds = OVERALL DEPTH OF SLAB.
F 11) T = EDGE THICKNESS OF SLAB.

10"x10"

10"x10"
12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
FB2

FB2
13) LAP LENGTH > Ld OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
5'-5"

14) Ldt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X BAR DIA.
15) Ldc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION 33X BAR
DIA.
E 16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA EQUALLY
DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB > 750 FOR STRAIGHT
BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB THICKNESS, WHICHEVER IS
S1 S1 LESS.
17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND HAVING
DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN NOTE (14 ).
12'-4"

S1 S1 18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF ANY,


50'-5"

SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C. PATNA.


19) GRID LINE SHOWS CL OF WALLS.
20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS No. 501,
Sl.No.-500, DATED-14-12-2010.

D
3 - #12 Thr. 1) TYPE OF STR.- LOAD BEARING

10"x10"
10"x10"
5'-5"

2) LOAD -G+2

FB2
FB2

FB 3) SEISMIC ZONE - V
4) NET ALLOWABLE B.P= 10 T/m AT A DEPTH OF 2.0 M
C

10"
8mm@4"to6"c/c
S4 S4
3- #12 Thr.
9'-8"

10"
S2 S2
SECTION AT -FB2
B
4'-5"

Z S5 7'
S5
W1
A W1

10'-6" level.

0.1L1 0.3L1 0.3L 2 0.3L1 0.3L 2 0.3L1 9"


15" #8 @ 3Nos

Floor Beam #10 @ 100c/c


0.15L1 0.25L 1 0.25L2 0.25L 1 0.25L2 0.25L 1
Level 8'-6"
L1 L2 L3 10"
#8 @ 3Nos

TYPICAL SECTION OF SLAB TRIPICAL BEAM SECTION


SECTION AT Z-Z
2 - #12 Thr.+
2 - #12 extra at
support

#8-2L @ 4"

12"
#8@200c/c to 6"C/C
Landing Floor Slab 21
2'-
0" 4 -#12 +Thr.
19 10"
6"

FB 17 SECTION OF LB1 & FB/ PB1


#10@4"c/c
(Main) 15

13
2'- 10"
#8@4"c/c
0"

6"
(Dist) #8@8"c/c
11

12"
#8@8"c/c
(Dist) LB2
2'-0"
#10@4"c/c #10@100c/c
(Main) LB1

A
1- #10
#8@12"c/c

10"
#10@4"c/c #8@8"c/c
12

12"
#8@8"c/c 0 "
2'-

5"
2'-0" LB2

eq
#10-1
A LB1
#10@4"c/c
T=as/arch.
R=as/arch eq
#8@8"c/c
eq eq
#10@4"c/c
(Main)
0"
2'-
#8@8"c/c
6"

(Dist)
1

#8@8"c/c 2 - #12 Thr.+


10" 2 - #12 extra at
(Dist)
12"

support
#10@4"c/c
(Main)
12"

#8-2L @ 4"
PB1(10"x12") to 6"C/C

T= 250 4 -#12 +Thr.

R= 150 SECTION OF LB2


Weist slab =150 th.
GRADE OF CONIC -M25
FE-500
JOB
SHEET No:- 8 / 9
BIHAR POLICE BUILDING CONSTRUCTION
TITLE
6 US QUARTER FOR CORPORATION, B.M.P. - 5, PATNA
BIHAR SWAVIMAN SPECIAL ARMS Sl. No:

POLICE FORCE AT - VALMIKINAGAR,BIHAR


DRG. No:
SHEET TITLE :

DETAILS OF STAIR DATE :


FAHAD NAQUI M. SAHU
ARCH. D'MAN A. E. DESIGN A. E. DESIGN STR.CONSULTANT ARCHITECT S.E.( ) CHIEF ENGINEER
1) NOTES AND INSTRUCTIONS INDICATED BELOW SHALL BE
FOLLOWED WITH DUE RESPONSIBILITY BY ENGINEER IN -CHARGE
DURING EXECUTION OF THE PROJECT
0.1L DISTRIBUTION BARS AT TOP
(MINIMUM 2 BARS) 0.3L1 0.3L2 2) THE ENGINEER IN -CHARGE SHALL STUDY IN DEPTH THE
ARCHITECTURAL/ STRUCTURAL DRAWINGS OF THE BUILDING
BEFORE EXECUTION AND AMBIGUITY IF ANY NOTICED BY HIM
SHALL BE REPORTED TO S.E./SR. ARCHITECT/SR. STR.ENGR.FOR
NECESSARY ACTION.
AS1 3) ALL DIMENSIONS ARE IN mm
0.15L 0.25L1 0.25L2 4) ALL DESIGN MIX CONCRETE OF GRADE M20 HAVING MINIMUM
EDGE CEMENT CONTENT 300 kg/m3, Max W/C = 0.55 FOR COARSE
BEAM AGGREGATE 20 mm SIZE.
L1 L2 5) # INDICATES HYSD BARS OF GRADE Fe 500.
6) ALL CONCRETE SHALL BE MACHINE MIXED AND VIBRATED.
TYPICAL SLAB DETAILS 7) NOMINAL COVER (i.e. CLEAR CONCRETE COVER TO ALL
REINFORCEMENTS, INCLUDING LINKS) FOR FOUNDATION = 50,
COLUMN = 40, BEAM = 30 AND SLAB = 30.
8) d = DIA OF MAIN BAR.
9) D = OVERALL DEPTH OF BEAM, d = EFFECTIVE DEFTH OF BEAM /
SLAB

#8-3NOS Thr.
1'-6"

10) Ds = OVERALL DEPTH OF SLAB.


11) T = EDGE THICKNESS OF SLAB.
MB2-10"x12" 12) Ld = EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X

#12-3 Thr. BAR DIA.


13) LAP LENGTH > L d OR 30 TIMES BAR DIA, WHICHEVER IS MORE.
14) L dt= EFFECTIVE DEVELOP. LENGTH CONSIDERING TENSION 49X
BAR DIA.
15) L dc = EFFECTIVE DEVELOP. LENGTH CONSIDERING COMPRESSION
Slab thickness

33X BAR DIA.


16) SIDE FACE REINFORCEMENT IN BEAMS = 0.1% OF WE AREA
125 mm

EQUALLY DISTRIBUTED ON BOTH FACES WHERE DEPTH OF WEB >

12"
750 FOR STRAIGHT BEAMS IN FLEXURE ONLY @ <300S c/c OR WEB

#8@ 4"to6"C/C THICKNESS, WHICHEVER IS LESS.


17) SIDE FACE REINFORCEMENT IN BEAMS RESISTING TORSION AND
HAVING DEPTH OF CROSS SECTION > 450 SHALL BE SAME AS IN
NOTE (14 ).
18) ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. AMBIGUITY, IF
ANY, SHALL BE BROUGHT TO THE NOTICE OF THE SE ( M ) B.P.B.C.C.
#8@4"c/c PATNA.
#12-3 Thr. 19) GRID LINE SHOWS CL OF WALLS.

10" 20) THIS DRAWING SHALL BE READ WITH ARCHITECTURAL DRAWINGS


No. , Sl.No. , DATED-
21)PROVIDE 3" THICK BAND AT SILL LEVEL

1) TYPE OF STR.- LOAD BEARAING


DETAILS BEAM - MB2 2) NET ALLOWABLE B.C.- 10t /SQM AT DEPTH OF 2.0 M AS PER S.I.R.
#8@6"c/c
Alt ckd

3) LOAD -G+1
4) SEISMIC ZONE - V G.F.C
6" BIHAR POLICE BUILDING CONSTRUCTION
CORPORATION, B.M.P. - 5, PATNA
MB2-250x400 #8-3NOS Thr. JOB TITLE
B
in Top Layer
#8@6"c/c

1'-6" #12-3thr.+#12-2extra SHEET TITLE :


DETAILS OF MUMTY SLAB
at support & BEAM
DRG. NO. - S.L NO. -
12"
MB2-10"x12" FAHAD NAQUI

#8@ 4"to6"C/C DATE - SHEET NO. - 9/9 (Draughtman)


1'-6"

#12-3 Thr.
10" A.E. DESIGN A.E. DESIGN
M. SAHU
STR.CONS.

DETAILS BEAM - MB1

ARCHITECT S. E. CHIEF ENGINEER