The document outlines the design specifications for a two-storey dormitory's concrete footing, including material properties, dimensions, and reinforcement details. It includes calculations for stability, soil pressure, shear, and punching shear, confirming that the design is safe under both service and ultimate loads. The footing dimensions are specified as 1.60 m x 1.60 m x 0.30 m with detailed reinforcement requirements for both directions.

Uploaded by

erwinvow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views1 page

F-1

The document outlines the design specifications for a two-storey dormitory's concrete footing, including material properties, dimensions, and reinforcement details. It includes calculations for stability, soil pressure, shear, and punching shear, confirming that the design is safe under both service and ultimate loads. The footing dimensions are specified as 1.60 m x 1.60 m x 0.30 m with detailed reinforcement requirements for both directions.

Uploaded by

erwinvow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project Name: Two Storey Dormitory Design by: ELL

Owner: NSTDC Mark: F1


Location: Cabid-An, Sorsogon City Location:
Check by: Erwin Lipardo Date: 09/21/2024

DESIGN OF CONCRETE FOOTING StrucEx Program

Material Properties Footing Properties Column Properties 2D Section Diagram


Concrete f'c = 21.00 MPa Lenght = 1.60 m Lenght = 0.40 m
Reinforcing fy = 276.0 MPa Width = 1.60 m Width = 0.30 m
Thickness = 0.30 m Location = Center
Soil Properties Depth = 1.20 m Offset, X Dir = 0.00 m
SDA = 120.00 kPa Water Table = 0.00 m Offset, Y Dir = 0.00 m
Soil Density ρs = 18.00 kN/m³ Reinforcement Properties
Friction Coeff μ = 0.45
Cover = 0.075 m Along X = 7 pcs
Friction Angle ϕ = 28.00 Degree
Mainbar = 16.00 m Along Y = 8 pcs
Applied forces:
Location Pu Mx My Fx Fy qa factor
kN kN/m kN/m kN kN Contact to Soil = 100.00 %
Service Load 304.82 0.00 0.00 0.04 33.28 1.33
Remark = Dimension is Safe
Ultimate Load 360.19 0.00 0.00 24.40 5.94 1.00

FOOTING SIZING CALCULATIONS (Service Load)


Check for Stability (Service Load) Service Load 3D Section Diagram
Overturning about x-x Overturning about y-y Sliding Calculation
● Moment = 0.00 kNm ● Moment = 0.00 kNm ● kp = 2.78
● ShearForce = 9.98 kNm ● ShearForce = 0.01 kNm ● Pressure mid d = 67.50 kN
● Total = 9.98 kNm ● Total = 0.01 kNm ● X-Passive Force = 32.40 kN
● Y-Passive Force = 32.40 kN
Resisting about x-x Resisting about y-y
● Friction force = 165.79 kN
● Footing Weight = 14.75 kNm ● Footing Weight = 14.75 kNm ● Safe Factor x-x = 99.90 kN
● Soil Weight = 42.16 kNm ● Soil Weight = 42.16 kNm ● Safe Factor y-y = 5.96 kN
● Bouyancy = -6.03 kNm ● Bouyancy = -6.03 kNm
● Axial = 243.86 kNm ● Axial = 243.86 kNm Remark = Safe
● Total = 294.74 kNm ● Total = 294.74 kNm
● Ratio = 29.52 ● Ratio = 99.90
Remark = Safe Remark = Safe

Check for Soil Pressure (Service Load) Service Load


Soil Pressure
● Overturn Mom x-x = 9.98 kNm ● Pu = 368.42 kN ● Xp = 0.80 m ● Pressure 1 = 158.50 kPa
● Resisting Mom x-x = 294.74 kNm ● Area = 2.56 m² ● Yp = 0.77 m ● Pressure 2 = 158.40 kPa
● Overturn Mom y-y = 0.01 kNm ● Sx = 0.68 m³ ● Xecc = 0.00 m ● Pressure 3 = 129.30 kPa
● Resisting Mom y-y = 294.74 kNm ● Sy = 0.68 m³ ● Yecc = 0.03 m ● Pressure 4 = 129.40 kPa

FOOTING THICKNESS CALCULATIONS (Factored Load) 2D Section Reinforcement

Soil Pressure
Soil Pressure (Factored Load)
● Overturn Mom x-x = 7.32 kNm ● Pu = 438.86 kN ● Xp = 0.80 m ● Pressure 1 = 184.80 kPa
● Resisting Mom x-x = 351.09 kNm ● Area = 2.56 m² ● Yp = 0.78 m ● Pressure 2 = 179.50 kPa
● Overturn Mom y-y = 1.78 kNm ● Sx = 0.68 m³ ● Xecc = 0.00 m ● Pressure 3 = 158.10 kPa
● Resisting Mom y-y = 351.09 kNm ● Sy = 0.68 m³ ● Yecc = 0.02 m ● Pressure 4 = 163.40 kPa
Check for Shear
Wide Beam Shear Punching Shear
Shear Forces calculated as Net Ultimate ● γf = 0.62 x-x ACI 13.5.3.2
the volume of bearing pressures soil pressure at critical point ● γf = 0.58 y-y ACI 13.5.3.2
● Vux (Left) = 108.96 kN ● Point 1 = 139.64 kN ● γv_x = 0.38 x-x ACI 11.11.7.1
● Vux (Right) = 96.76 kN ● Point 2 = 127.88 kN ● γv_y = 0.42 y-y ACI 11.11.7.1
● Vuy (Left) = 118.59 kN ● Point 3 = 148.82 kN ● j/c1 = 0.1000 N/mm² x-x
● Vuy (Right) = 114.61 kN ● Point 4 = 146.39 kN ● j/c1 = 0.1087 N/mm² y-y
● Average = 140.68 kN ● Vu = 0.42 kN ACI 11.11.5.2.a
Ultimate Shear Capacity
Vc = φ0.166λ√f'c - ACI 22.5.5.1 ● φVu= 1.72 kN ACI 11.11.5.2.b
Calculation of unbalanced moment
● Reduction factor φ = 0.75 transferred by eccentricity of shear Calculation of RC punching shear
● λ = 1.00 resistance without shear reinforcement
● β = 1.33 ACI 11.11.2.1.a FOOTING REINFORCEMENT
● Vcx = Vc×(L×d)= 195.38 kN ● αs = 40.00 ACI 11.11.2.1.b ● Vc = 1.95 N/mm² ACI 11.11.2.1.a CALCULATIONS (Factored Load)
● Vcy = Vc×(W×d)= 195.38 kN ● b1 = 0.53 m ● Vc = 2.22 N/mm² ACI 11.11.2.1.b
● Ratio x = Max_Vux / Vcx = 0.56 ● b2 = 0.63 m ● Vc = 1.51 N/mm² ACI 11.11.2.1.c Reinforcement Along X Reinforcement Along Y
● Ratio y = Max_Vuy / Vcy = 0.61 ● bo = 2.34 m ● φVc= 1.13 N/mm² ● Mu = 49.92 kNm ● Mu = 60.65 kNm
Remark = Safe ● Critical Area = 0.34 mm² ● Ratio = 0.37 ● Ru = 0.68 MPa ● Ru = 0.83 MPa
● Resultant = 140.68 kN Remark = Safe for Punching Shear! ● m = 15.46 ● m = 15.46
● req'd p = 0.00253 ● req'd p = 0.00309
FOOTING DETAIL SUMMARY ● min p = 0.00507 ● min p = 0.00507
Footing Dimension = 1.60 m × 1.60 m × 0.30 m ● use p =0.00253 ● use p =0.00309
● As = 910.96 mm² ● As = 1,111.69 mm²
Reinforcement Along X = 7.00 pcs - 16.00 mm bar ⌀ space equally on center to center
● use n1 = 7.00 pcs ● use n2 = 8.00 pcs
Reinforcement Along Y = 8.00 pcs - 16.00 mm bar ⌀ space equally on center to center
● spacing = 214.67 mm ● spacing = 212.00 mm