0% found this document useful (0 votes)
5 views4 pages

Cat6 Futp Cable CC6FBLL3

NEXCONEC® Category 6 F/UTP cables are designed for high-speed network applications, supporting distances up to 100 meters and exceeding performance standards for Category 6 cables. The cables feature a 23AWG copper conductor and are suitable for environments with external interference, complying with various international standards. They are available in different jacket materials and colors, with specific mechanical and electrical properties outlined for optimal performance.

Uploaded by

Crazy Games
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views4 pages

Cat6 Futp Cable CC6FBLL3

NEXCONEC® Category 6 F/UTP cables are designed for high-speed network applications, supporting distances up to 100 meters and exceeding performance standards for Category 6 cables. The cables feature a 23AWG copper conductor and are suitable for environments with external interference, complying with various international standards. They are available in different jacket materials and colors, with specific mechanical and electrical properties outlined for optimal performance.

Uploaded by

Crazy Games
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

COPPER SYSTEMS

Cables

CAT.6 F/UTP CABLE - CC6FBLL3

Browse on Mobile

Browse on Web

NEXCONEC® Category 6 F/UTP cables are specifically designed to deliver robust standards-based performance ensuring
optimum bandwidth for today’s high speed network applications. The cable is designed to support horizontal networking
applications over distances up to 100 meters.

Each Category 6 F/UTP exceed the minimum specified performance for Category 6 F/UTP cables and support all CLASS E
applications.

FEATURES

✓ Conform to IEC, EIA-TIA performance requirements


✓ 23AWG premium grade copper conductor
✓ F/UTP cable structure for better shielding in external interference environments
✓ Cable jacket available in LSZH, CM, PVC
✓ CPR Euro classes certified on demand

APPLICATIONS

✓ Supports category 6 (Class E) networks running up to 250MHz applications


✓ Ideal for environments where external interferences can disrupt signals
✓ Horizontal and backbone in structured cabling installations

Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com


COPPER SYSTEMS
Cables

SPECIFICATIONS

Parameters Value

Electrical Performance Certified performance in a 4-connector configuration up to 100 meters

Conductor/Insulator 23 AWG solid copper insulated with HPDE

Operating Temperature -20°C ~ +75°C

Compliance ANSI/TIA-568-C.2, ISO 11801, IEC 60603-7

RoHS Compliance Compliant

CABLE SPECIFICATION (CONSTRUCTION)

Parameters Units Value

Cable Jacket Type LSZH/PVC/PE LSZH CPR B2ca (s1,d1,a1)

Cable OD mm 7.2mm±0.2mm 7.5mm±0.2mm

F/UTP, An aluminized polyester tape applied with a 15% minimum


Shielding
overlap at 4 twisted pairs, the drain wire is attached to the Al. foil

Insulation HDPE

Pair 1: White/Blue, and Blue


Pair 2: White/Orange, and Orange
Pair Color Codes
Pair 3: White/Green, and Green
Pair 4: White/Brown, and Brown

Blue (RAL 5012)


Sheath Color Grey (RAL 7046)
Black (RAL 9005)

Conductor 23AWG solid copper

Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com


COPPER SYSTEMS
Cables

CABLE SPECIFICATION (MECHANICAL)

Parameters Value

Bulk Cable Weight 50 Kg/km

Max. Pull Tension 100N

Min. Bend Radius (installation) 8x OD.

Min. Bend Radius (installed) 4x OD.

Cold Bend No crack @-20℃ x 4hrs

Storage Temp. -20℃ to +70℃

Operation Temp. -20℃ to +60℃

Installation Temp. 0℃ to +50℃

CABLE SPECIFICATION (ELECTRICAL PROPERTIES AT 20℃)

Parameters Units Value


(1-100MHz) 100 ±15Ω
Characteristic Impedance
(100-250MHz) 100 ±18Ω

DC Resistance Ω/100m ≤ 9.35Ω/100m max.


Resistance Unbalance % ≤ 5%
Capacitance Unbalance to Earth Pf/km ≤ 330 pF/km
Delay Skew ns/100m ≤ 44ns/100m
Nominal Velocity of Propagation % 68%
Propagation Delay (Nominal) ns/100m 533ns/100m at 250MHz
Test Voltage (d.c. for 1 minute)
VDC 1000V
Conductor /Conductor

Insulation Resistance (500V d.c) MΩ ≥ 500MΩ/KM

Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com


COPPER SYSTEMS
Cables

TRANSMISSION LINE PERFORMANCE AT 20℃

Freq. RL ATT NEXT PHASE DELAY PSNEXT ELFEXT PSELFEXT


MHz ≥dB ≤dB ≥dB ≤ns ≥dB ≥dB ≥dB
1 20 2 74.5 570 72.3 68 65
4 23 3.7 65.3 552 63.3 56 53
10 25 5.9 59.3 545 57.3 48 45
20 25 8.3 54.8 541.2 52.8 42 39
62.5 21.5 15.9 47.4 538.5 45.4 32.1 29.1
100 20 19.5 44.3 537.6 42.3 28 25
250 17.3 33.5 38.2 536.1 36.5 19.8 17
300* 16.2 39.4 36.5 - 34.3 16.8 12.5
500* 15.3 48.1 33.7 - 31.7 13.4 10.4
550* 14.5 51.92 33.5 - 31.3 12.9 9.9

* Performance for frequencies beyond TIA and ISO requirements are for information only.

ORDER INFORMATION

CC 1 2 3 4 5

CABLE JACKET JACKET


CC 1 CABLE CATEGORY 2 3 4 5 PACKING
STRUCTURE COLOR MATERIAL

6 CAT 6 F F/UTP BL BLUE L LSZH 3 305MTR/ CARTON

GY GREY LB LSZH CPR B2CA 5 500MTR/ REEL

WH WHITE C PVC CMSS

BK BLACK P PVC

GR GREEN E PE

PR PURPLE

RD RED

Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com

You might also like