COPPER SYSTEMS
Cables
CAT.6 F/UTP CABLE - CC6FBLL3
Browse on Mobile
Browse on Web
NEXCONEC® Category 6 F/UTP cables are specifically designed to deliver robust standards-based performance ensuring
optimum bandwidth for today’s high speed network applications. The cable is designed to support horizontal networking
applications over distances up to 100 meters.
Each Category 6 F/UTP exceed the minimum specified performance for Category 6 F/UTP cables and support all CLASS E
applications.
FEATURES
✓ Conform to IEC, EIA-TIA performance requirements
✓ 23AWG premium grade copper conductor
✓ F/UTP cable structure for better shielding in external interference environments
✓ Cable jacket available in LSZH, CM, PVC
✓ CPR Euro classes certified on demand
APPLICATIONS
✓ Supports category 6 (Class E) networks running up to 250MHz applications
✓ Ideal for environments where external interferences can disrupt signals
✓ Horizontal and backbone in structured cabling installations
Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com
COPPER SYSTEMS
Cables
SPECIFICATIONS
Parameters Value
Electrical Performance Certified performance in a 4-connector configuration up to 100 meters
Conductor/Insulator 23 AWG solid copper insulated with HPDE
Operating Temperature -20°C ~ +75°C
Compliance ANSI/TIA-568-C.2, ISO 11801, IEC 60603-7
RoHS Compliance Compliant
CABLE SPECIFICATION (CONSTRUCTION)
Parameters Units Value
Cable Jacket Type LSZH/PVC/PE LSZH CPR B2ca (s1,d1,a1)
Cable OD mm 7.2mm±0.2mm 7.5mm±0.2mm
F/UTP, An aluminized polyester tape applied with a 15% minimum
Shielding
overlap at 4 twisted pairs, the drain wire is attached to the Al. foil
Insulation HDPE
Pair 1: White/Blue, and Blue
Pair 2: White/Orange, and Orange
Pair Color Codes
Pair 3: White/Green, and Green
Pair 4: White/Brown, and Brown
Blue (RAL 5012)
Sheath Color Grey (RAL 7046)
Black (RAL 9005)
Conductor 23AWG solid copper
Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com
COPPER SYSTEMS
Cables
CABLE SPECIFICATION (MECHANICAL)
Parameters Value
Bulk Cable Weight 50 Kg/km
Max. Pull Tension 100N
Min. Bend Radius (installation) 8x OD.
Min. Bend Radius (installed) 4x OD.
Cold Bend No crack @-20℃ x 4hrs
Storage Temp. -20℃ to +70℃
Operation Temp. -20℃ to +60℃
Installation Temp. 0℃ to +50℃
CABLE SPECIFICATION (ELECTRICAL PROPERTIES AT 20℃)
Parameters Units Value
(1-100MHz) 100 ±15Ω
Characteristic Impedance
(100-250MHz) 100 ±18Ω
DC Resistance Ω/100m ≤ 9.35Ω/100m max.
Resistance Unbalance % ≤ 5%
Capacitance Unbalance to Earth Pf/km ≤ 330 pF/km
Delay Skew ns/100m ≤ 44ns/100m
Nominal Velocity of Propagation % 68%
Propagation Delay (Nominal) ns/100m 533ns/100m at 250MHz
Test Voltage (d.c. for 1 minute)
VDC 1000V
Conductor /Conductor
Insulation Resistance (500V d.c) MΩ ≥ 500MΩ/KM
Copyrights © NEXCONEC - 2024 All Rights Reserved. [email protected] nexconec.com
COPPER SYSTEMS
Cables
TRANSMISSION LINE PERFORMANCE AT 20℃
Freq. RL ATT NEXT PHASE DELAY PSNEXT ELFEXT PSELFEXT
MHz ≥dB ≤dB ≥dB ≤ns ≥dB ≥dB ≥dB
1 20 2 74.5 570 72.3 68 65
4 23 3.7 65.3 552 63.3 56 53
10 25 5.9 59.3 545 57.3 48 45
20 25 8.3 54.8 541.2 52.8 42 39
62.5 21.5 15.9 47.4 538.5 45.4 32.1 29.1
100 20 19.5 44.3 537.6 42.3 28 25
250 17.3 33.5 38.2 536.1 36.5 19.8 17
300* 16.2 39.4 36.5 - 34.3 16.8 12.5
500* 15.3 48.1 33.7 - 31.7 13.4 10.4
550* 14.5 51.92 33.5 - 31.3 12.9 9.9
* Performance for frequencies beyond TIA and ISO requirements are for information only.
ORDER INFORMATION
CC 1 2 3 4 5
CABLE JACKET JACKET
CC 1 CABLE CATEGORY 2 3 4 5 PACKING
STRUCTURE COLOR MATERIAL
6 CAT 6 F F/UTP BL BLUE L LSZH 3 305MTR/ CARTON
GY GREY LB LSZH CPR B2CA 5 500MTR/ REEL
WH WHITE C PVC CMSS
BK BLACK P PVC
GR GREEN E PE
PR PURPLE
RD RED