Product Data Sheet Rosemount 3300 Level Transmitter en 73582
Product Data Sheet Rosemount 3300 Level Transmitter en 73582
00813-0100-4811, Rev JF
September 2024
A. Reference pulse
B. Level
C. Interface level
Contents
Proven, reliable, and easy to use guided wave radar.................................................................................................................... 2
Ordering information.........................................................................................................................................................................5
Specifications.................................................................................................................................................................................... 18
Installation and mounting considerations....................................................................................................................................35
Product certifications....................................................................................................................................................................... 41
Dimensional drawings..................................................................................................................................................................... 42
2 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
www.Emerson.com 3
Rosemount 3300 Level Transmitter September 2024
4 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Ordering information
Online product configurator
Many products are configurable online using our product configurator.
Select the Configure button or visit Emerson.com/global to start. With this tool's built-in logic and continuous validation,
you can configure your products more quickly and accurately.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model
code is shown in Figure 2.
Figure 2: Model Code Example
3302 H S 1 S 1 V 4B E 10 27 RA I7 M5 B2 WR3
1 2
www.Emerson.com 5
Rosemount 3300 Level Transmitter September 2024
Code Description
3301 Guided Wave Radar Level Transmitter (interface available for fully submerged probe) ★
Signal output
Code Description
Related information
4-20 mA HART
Modbus
Housing material
Code Description
A Polyurethane-covered Aluminum ★
Code Description
6 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
S Design and operating temperature: Design and operating pressure: 3301: All ★
-40 to 302 °F -15 to 580 psig 3302: 3B, 4A, 4B, and 4S
(-40 to 150 °C) (-1 to 40 bar)
Related information
Process temperature and pressure rating
2 Alloy C-276 (UNS N10276). With plate design if flanged version. 3301: 3A, 3B, 4A, 4B, 5A, and 5B
3302: 3B, 4A, 4B, 5A, and 5B
3 Alloy 400 (UNS N04400). With plate design if flanged version. 3301: 3A, 3B, 4A, 4B, 5A, and 5B
3302: 3B, 4A, and 4B
7 PTFE covered probe and flange. With plate design. 3301: 4A and 5A, Flanged version
3302: 4A, Flanged version
Code Description
V Fluoroelastomer (FKM) ★
3B Coaxial, perforated. For level and interface Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m) ★
measurement. Max: 19 ft. 8 in. (6 m)
4B(1) Rigid Single Lead 0.5 in. (13 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m) ★
Tri-Clamp® Max: 19 ft. 8 in. (6.0 m)
5A Flexible Single Lead with weight Flange / 1-in., 1½-in., 2-in. Thread / Min.: 3 ft. 4 in. (1 m) ★
Tri-Clamp Max: 77 ft. (23.5 m)
3A Coaxial (for level measurement) Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m)
Max: 19 ft. 8 in. (6 m)
www.Emerson.com 7
Rosemount 3300 Level Transmitter September 2024
4A Rigid Single Lead 0.3 in. (8 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
Tri-Clamp Max: 9 ft. 10 in. (3 m)
4S Segmented Rigid Single Lead 0.5 in. Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
(13 mm) Tri-Clamp Max: 19 ft. 8 in. (6.0 m)
5B Flexible Single Lead with chuck Flange / 1-in., 1½-in., 2-in. Thread / Min.: 3 ft. 4 in. (1 m)
Tri-Clamp Max: 77 ft. (23.5 m)
3B Coaxial, perforated. For level and interface Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m) ★
measurement. Max: 19 ft. 8 in. (6 m)
4B(1) Rigid Single Lead 0.5 in. (13 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m) ★
Tri-Clamp Max: 19 ft. 8 in. (6.0 m)
4A Rigid Single Lead 0.3 in. (8 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
Tri-Clamp Max: 9 ft. 10 in. (3 m)
4S Segmented Rigid Single Lead 0.5 in. Flange / 1-in., 1½-in., 2-in.Thread / Min.: 1 ft. 4 in. (0.4 m)
(13 mm) Tri-Clamp Max: 19 ft. 8 in. (6.0 m)
Code Description
Code Description
XX 0 - 77 ft. or 0-23 m ★
Code Description
XX 0 - 11 in. or 0-99 cm ★
8 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Code Description
EN 1092-1 flanges(1)(4)
JIS flanges(1)(4)
RC 2-in. NPT thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B ★
3302: 3B, 4A, 4B, and 4S
RB 1-in. NPT thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B
3302: 3B, 4A, 4B, and 4S
SB(4) 1-in. BSP (G 1-in.) thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B
3302: 3B, 4A, 4B, and 4S
www.Emerson.com 9
Rosemount 3300 Level Transmitter September 2024
Code Description
Proprietary flanges
TF Fisher™ - proprietary 316/316L (for 249B, 259B chambers) Torque Tube Flange ★
(1) Available in material 316/316L and EN 1.4404. For other materials consult the factory.
(2) Design according to ASME B31.3. No code stamp or ASME certificate available.
(3) Forged one-piece flange provided for Material of construction code 1, 7 or 8, together with Probe type code 3A, 3B, 4A, 4B, 4S, 5A, or
5B. Welded construction provided for other combinations.
(4) Not available with Canadian Registration Number (CRN).
(5) Follows ISO 2852 standard.
Related information
Process temperature and pressure rating
Flange rating
Tri Clamp rating
Code Description
10 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Additional options
Display
Code Description
Hydrostatic testing
Available for tank connection with flange.
Code Description
Materials certification
Available for probe type 3A, 3B, 4A, 4B, and 4S.
Code Description
N2 NACE® material recommendation per NACE MR0175/ISO 15156 and NACE MR0103/ISO 17945 ★
Installation options
Code Description
LS(1) Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle. Standard stud length is ★
3.9 in (100 mm).
Code Description
(1) Only for Material of Construction code 1 and Probe Type 5A.
Related information
Dimensional drawings
www.Emerson.com 11
Rosemount 3300 Level Transmitter September 2024
Centering disc
Available for SST, Alloy C-276, and Alloy 400 probes, types 4A, 4B, 4S, and 5A.
Not available with PTFE covered probes (Material of Construction codes 7 and 8).
Code Description
Related information
Centering disc for pipe installations
Remote housing
Requires software version 10 or higher.
Code Description
Related information
Dimensional drawings
Factory configuration
Code Description
Alarm limits
Code Description
12 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Code Description
Code Description
Code Description
Code Description
Code Description
Overfill prevention
Code Description
Assemble/consolidate to chamber
Selecting the XC option code on the Rosemount 3300 and a Rosemount chamber will result in matching, consolidating,
configuring, and shipping of the two products in one crate. Note that the flange bolts are only hand-tightened. Long
rigid single lead probes (>8 ft./2.5 m) are ship separately in order to reduce transportation risk damage.
Code Description
XC Consolidate to Chamber ★
Specials
Code Description
RXXXX Custom engineered solutions beyond standard model codes. Consult factory for details.
www.Emerson.com 13
Rosemount 3300 Level Transmitter September 2024
Accessories
Weight kit
Item number Description
Centering discs for rigid single lead probe (d=0.3 in./8 mm)
If a centering disc is required for a flanged probe, the centering disc can be ordered with options Sx or Px in the model
code. If a centering disc is required for a threaded connection, or as a spare part, it should be ordered using the item
numbers listed in this table.
For other materials, consult the factory.
03300-1655-0001 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★
03300-1655-0006 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★
03300-1655-0002 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★
03300-1655-0007 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★
03300-1655-0003 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★
03300-1655-0008 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★
03300-1655-0004 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)
03300-1655-0009 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)
03300-1655-0005 Kit, 8-in. Centering disc, SST 7.40 in. (188 mm)
03300-1655-0010 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)
Related information
Centering disc for pipe installations
Centering discs for rigid single lead probe (d=0.5 in./13 mm)
If a centering disc is required for a flanged probe, the centering disc can be ordered with options Sx or Px in the model
code. If a centering disc is required for a threaded connection, or as a spare part, it should be ordered using the item
numbers listed in this table.
For other materials, consult the factory.
03300-1655-0301 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★
03300-1655-0306 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★
03300-1655-0302 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★
03300-1655-0307 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★
03300-1655-0303 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★
03300-1655-0308 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★
03300-1655-0304 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)
03300-1655-0309 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)
14 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
03300-1655-0305 Kit, 8-in. Centering disc, SST 7.40 in. (188 mm)
03300-1655-0310 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)
Related information
Centering disc for pipe installations
03300-1655-1001 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★
03300-1655-1006 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★
03300-1655-1002 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★
03300-1655-1007 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★
03300-1655-1003 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★
03300-1655-1008 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★
03300-1655-1004 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)
03300-1655-1009 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)
03300-1655-1005 Kit, 8-in. Centering disc, SST, 7.40 in. (188 mm)
03300-1655-1010 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)
Related information
Centering disc for pipe installations
03300-1656-1002 2-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 1.8 in. (45 mm)
03300-1656-1003 3-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 2.7 in. (68 mm)
03300-1656-1004 4-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 3.6 in. (92 mm)
03300-1656-1006 6-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 5.55 in. (141 mm)
www.Emerson.com 15
Rosemount 3300 Level Transmitter September 2024
03300-1656-1008 8-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 7.40 in. (188 mm)
03300-1656-3002 2-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 1.8 in. (45 mm)
03300-1656-3003 3-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 2.7 in. (68 mm)
03300-1656-3004 4-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 3.6 in. (92 mm)
03300-1656-3006 6-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 5.55 in. (141 mm)
03300-1656-3008 8-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 7.40 in. (188 mm)
03300-1656-5002 2-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 1.8 in. (45 mm)
03300-1656-5003 3-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 2.7 in. (68 mm)
03300-1656-5004 4-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 3.6 in. (92 mm)
03300-1656-5006 6-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 5.55 in. (141 mm)
03300-1656-5008 8-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 7.40 in. (188 mm)
Vented flanges
1-½ in. NPT threaded connection (RA) is required.
Not available with Canadian Registration Number (CRN).
16 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
03300-7006-0001 1 m / 3.2 ft. Remote Housing Mounting Cable and 316L Bracket
03300-7006-0002 2 m / 6.5 ft. Remote Housing Mounting Cable and 316L Bracket
03300-7006-0003 3 m / 9.8 ft. Remote Housing Mounting Cable and 316L Bracket
www.Emerson.com 17
Rosemount 3300 Level Transmitter September 2024
Specifications
Performance specifications
General
Reference conditions
Twin Lead probe, 77 °F (25 °C) water
Reference accuracy
± 0.2 in. (5 mm) for probes ≤16.4 ft. (5 m)
± 0.1% of measured distance for rigid probes >16.4 ft. (5 m)
± 0.15% of measured distance for flexible probes >16.4 ft. (5 m)
For probes with spacers, the accuracy may deviate close to the spacers. Accuracy may be affected by remote housing.
Repeatability
± 0.04 in. (1 mm)(1)
Ambient temperature effect
Less than 0.01% of measured distance per °C
Update interval
Minimum 1 update per second
Environment
Vibration resistance
■ Polyurethane-covered aluminum housing: IEC 60770-1
■ SST housing: IACS E10
Electromagnetic compatibility
Emission and Immunity: meets EN 61326-1:2013, class A equipment intended for use in industrial locations if installed
in metallic vessels or still-pipes.
When rigid/flexible single probes are installed in non-metallic or open vessels, influence of strong electromagnetic
fields might affect measurements.
Related information
Installation in non-metallic tanks and open-air applications
CE-mark
The 4–20 mA HART version (Output Option Code H) complies with applicable directives (EMC and ATEX).
Built-in lightning protection
Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4
(1) In accordance with IEC 60770-1. See the IEC 60770-1 standard for a definition of radar specific performance parameters and if applicable
corresponding test procedures.
18 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Contamination/product build-up
■ Single lead probes are preferred when there is a risk of contamination (because build-up can result in the product
bridging between the inner lead and outer pipe for the coaxial probe).
■ For viscous or sticky applications, PTFE probes are recommended. Periodic cleaning may also be required.
■ For viscous or sticky applications, it is not recommended to use centering discs mounted along the single lead
probe.
■ Maximum error due to coating is 1 to 10% depending on probe type, dielectric constant, coating thickness, and
coating height above product surface.
Table 1: Maximum Recommended Viscosity and Contamination/Build-up
(1) Consult your local Emerson representative in the case of agitation/turbulence and high viscous products.
Measuring range
Measuring range and minimum dielectric constant
See Table 2 and Table 3 for each probe’s measuring range and minimum dielectric constant. Due to the measuring
range depending on the application and factors described below, the values are a guideline for clean liquids. For more
information, ask your local Emerson representative.
Note
See Table 4 for the measuring range when using the Remote Housing.
Different parameters (factors) affect the echo and therefore the maximum measuring range differs depending on
application according to:
■ Disturbing objects close to the probe.
■ Media with higher dielectric constant (εr) gives better reflection and allows a longer measuring range.
■ Surface foam and particles in the tank atmosphere may affect measuring performance.
■ Heavy product build-up or contamination on the probe should be avoided since it can reduce measuring range and
might cause erroneous level readings.
Table 2: Maximum Measuring Range
Rigid single lead/segmented rigid single lead 9 ft. 10 in. (3 m) for 8 mm probes (code 4A)
19 ft. 8 in. (6 m) for 13 mm probes (code 4B)
19 ft. 8 in. (6 m) for 13 mm probes (code 4S)
www.Emerson.com 19
Rosemount 3300 Level Transmitter September 2024
Coaxial 1.5
Table 4: Measuring Range and Minimum Dielectric Constant when using Remote Housing
Maximum measuring range 9 ft. 10 in. (3 m) for 8 mm 77 ft. 1 in. (23.5 m) 19 ft. 8 in. (6 m)
probes
14 ft. 9 in. (4.5 m) for 13
mm probes
20 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
A
B
D D
Upper Transition Zone(1) 80 4 in. (10 cm) 5.9 in. (15 cm) 4 in. (10 cm)
Lower Transition Zone(2) 80 2 in. (5 cm) 2 in. (5 cm)(3)(4) 1.2 in. (3 cm)
2 4 in. (10 cm) 6.3 in. (16 cm) - long weight, 2 in. (5 cm)
short weight, and chuck(4)(5)
(1) The distance from the upper reference point where measurements have reduced accuracy.
(2) The distance from the lower reference point where measurements have reduced accuracy.
(3) The measuring range for the PTFE covered Flexible Single Lead probe includes the weight when measuring on a high dielectric
media.
(4) Note that the weight length or chuck fastening length adds to non-measurable area and is not included in the diagram.
(5) When using a metallic centering disc, the lower transition zone is 8 in. (20 cm), including weight if applicable. When using a PTFE
centering disc, the lower transition zone is not affected.
Note
The 4–20 mA set points are recommended to be configured between the transition zones, within the measuring range.
www.Emerson.com 21
Rosemount 3300 Level Transmitter September 2024
Functional specifications
General
Field of application
Liquids and semi-liquids level or liquid/liquid interfaces
■ Model 3301, for level or submerged probe interface measurement
■ Model 3302, for level and interface measurements
Measurement principle
Time Domain Reflectometry (TDR)
Microwave output power
Nominal 50 μW, Max. 2 mW
EMC
FCC part 15 subpart B and EMC Directive (2014/30/EU). Considered to be an unintentional radiator under the Part 15
rules.
Humidity
0 to 100% relative humidity
Start-up time
< 10 s
4-20 mA HART®
Output
Two-wire, 4-20 mA. Digital process variable is superimposed on 4-20 mA signal, and available to any host that conforms
to the HART® protocol. The digital HART signal can be used in multidrop mode.
® ™
Rosemount 333 HART Tri-Loop
By sending the digital HART signal to the optional HART Tri-Loop, it is possible to have up to three additional 4–20 mA
analog signals.
Related information
Rosemount 333 Product Data Sheet
™
Emerson Wireless 775 THUM Adapter
The optional Emerson Wireless 775 THUM Adapter can be mounted directly on the transmitter or by using a remote
mounting kit.
IEC 62591 (WirelessHART®) enables access to multivariable data and diagnostics, and adds wireless to almost any
measurement point.
22 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Related information
Emerson Wireless 775 THUM Adapter Product Data Sheet
Power requirements
Terminals in the transmitter housing provide connections for signal cables. The Rosemount 3300 Level Transmitter is
loop-powered and operates with the following power supplies:
Table 6: External Power Supply for HART
None 11 - 42 Vdc
Explosion-proof/Flameproof 16 - 42 Vdc
R
UE
UI
For Flameproof/Explosion-proof installations the Rosemount 3300 Series transmitters have a built-in barrier; no
external barrier needed.
When the Emerson Wireless 775 THUM™ Adapter is fitted, it adds a maximum drop of 2.5 Vdc in the connected loop.
Signal on alarm
High Low
Saturation levels
High Low
www.Emerson.com 23
Rosemount 3300 Level Transmitter September 2024
Load limitations
For HART® communication, a minimum loop resistance of 250 Ω is required. Maximum loop resistance is determined
by the voltage level of the external power supply, as given by the following diagrams:
Figure 5: Non-Hazardous Installations
A C
A
C
Note
For the Explosion-proof/Flameproof installations the diagram is only valid if the HART load resistance is at the + side,
otherwise the load resistance value is limited to 300 Ω.
24 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Modbus®
Output
The RS-485 Modbus version communicates by Modbus RTU, Modbus ASCII, and Levelmaster protocols.
8 data bits, 1 start bit, 1 stop bit, and software selectable parity.
Baud Rate 1200, 2400, 4800, 9600 (default), and 19200 bits/s
Address Range 1 to 255 (default device address is 246)
HART communication is used for configuration via the HART terminals or tunneling via the RS-485.
External power supply
The input voltage Ui for Modbus is 8-30 Vdc (max. rating).
Figure 8: External Power Supply for Modbus
RS485 bus
UI
For Flameproof/Explosion-proof installations the Rosemount 3300 Series transmitters have a built-in barrier; no
external barrier needed.
Power consumption
■ < 0.5 W (with HART address=1)
■ < 1.2 W (incl. four HART slaves)
Remote display
Data can be read remotely by using the Rosemount 751 Field Signal Indicator, see the corresponding Product Data
Sheet for more information.
www.Emerson.com 25
Rosemount 3300 Level Transmitter September 2024
Configuration tools
■ Rosemount Radar Configuration Tool (included in the delivery)
■ Device Descriptor (DD) compliant systems
■ Device Type Manager (DTM™) compliant systems
Output units
■ Level, Interface and Distance: ft., in., m, cm, or mm
■ Volume: ft.3, in.3, US gals, Imp gals, barrels, yd3, m3, or liters
Output variables
Table 7: Output Variables
Level ✓ ✓
Volume ✓ ✓
Internal Temperature ✓ ✓
Peak Amplitudes ✓ ✓
Damping
0-60 s (10 s, default value)
26 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
580 (40)
232 (16)
C
-15 (-1)
B
-40 302
(-40) (150)
Table 8: Temperature and Pressure Ranges for Standard Tank Seals with Different O-ring Material
Note
Always check the chemical compatibility of the O-ring material with your application. If the O-ring material is not
compatible with its chemical environment, the O-ring may eventually malfunction.
www.Emerson.com 27
Rosemount 3300 Level Transmitter September 2024
Temperature limits
Ambient temperature
The maximum and minimum ambient temperature for the electronics depends the approval.
Note
In applications where the ambient temperature exceeds the limits of the electronics, a Remote Mounting connection
can be used. The maximum temperature for the Remote Mounting connection at the vessel connection point is 302 °F
(150 °C).
Without integral display -40 °F to 185 °F (-40 °C to 85 °C) -40 °F to 176 °F (-40 °C to 80 °C)
With integral display -40 °F to 158 °F (-40 °C to 70 °C)(1) -40 °F to 176 °F (-40 °C to 80 °C)
(1) Integral display may not be readable and device display updates will be slower at temperatures below -4 °F (-20 °C).
Related information
Product certifications
Flange rating
ASME flange rating
316 according to ASME B16.5 Table 2-2.2:
■ Maximum 302 °F/580 psig (150 °C/40 bar)
EN flange rating
EN 1.4404 according to EN 1092-1 material group 13E0:
■ Maximum 302 °F/580 psig (150 °C/40 Bar)
28 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Plate design
Certain models of flanged alloy and PTFE covered probes have a tank connection design with a protective flange
plate that prevents the backing flange from being exposed to the tank atmosphere. The protective flange plate is
manufactured in the same material as the probe. The backing flange is made of 316L/EN 1.4404 for alloy probes, and
316/1.4404 for PTFE covered probes.
Figure 10: Protective Plate
$ %
&
www.Emerson.com 29
Rosemount 3300 Level Transmitter September 2024
ASME Stainless steel SA193 Soft (1a) with min. Stainless steel A182 Gr. Stainless steel SA479M
B8M Cl.2 thickness 1.6 mm F316 316
EN, JIS EN 1515-1/-2 group Soft (EN 1514-1) with Stainless steel A182 Stainless steel SA479M
13E0, A4-70 min. thickness 1.6 mm Gr. F316 and EN 316, and EN
10222-5-1.4404 10272-1.4404
ASME Stainless steel SA193 Soft (1a) with min. Stainless steel A182 Gr. SB574 Gr. N10276 or
B8M Cl.2 thickness 1.6 mm F316L/F316 SB164 Gr. N04400
EN, JIS EN 1515-1/-2 group Soft (EN 1514-1) with Stainless steel A182
13E0, A4-70 min. thickness 1.6 mm Gr. F316L/F316 and EN
10222-5-1.4404
ASME UNS N10276 Soft (1a) with min. SB462 Gr. N10276 SB574 Gr. N10276
thickness 1.6 mm (solution annealed
condition) or SB575
EN, JIS Soft (EN 1514-1) with Gr. N10276 (solution
min. thickness 1.6 mm annealed condition)
Interface measurements
The Rosemount 3302 is a good choice for measuring the interface of oil and water, or other liquids with significant
dielectric differences. It is also possible to measure interfaces with a Rosemount 3301 in applications where the probe
is fully submerged in the liquid.
Figure 11: Interface Level Measurement
A B
A. Rosemount 3302
B. Rosemount 3301 (fully submerged)
C. Product level
D. Interface level
30 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
■ The dielectric constant of the upper product should be known and should not vary. The Radar Configuration Tools
software has a built-in dielectric constant calculator to assist the user in determining the dielectric constant of the
upper product.
■ The dielectric constant of the upper product must have a lower dielectric constant than the lower product to have a
distinct reflection.
■ The difference between the dielectric constants for the two products must be larger than 10.
■ Maximum dielectric constant for the upper product is 10 for the coaxial probe.
■ The upper product thickness must be larger than 4 in. (0.1 m) for the coaxial probe in order to distinguish the
echoes of the two liquids.
Emulsion layers
Sometimes there is an emulsion layer (mix of the products) between the two products which can affect interface
measurements. For guidelines on emulsion situations, consult your local Emerson representative.
Physical specifications
Material selection
Emerson provides a variety of Rosemount products with various product options and configurations, including
materials of construction that can be expected to perform well in a wide range of applications.
The product information presented is intended as a guide for the purchaser to make an appropriate selection
for the application. It is the purchaser’s sole responsibility to make a careful analysis of all process parameters
(such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying
product, materials, options, and components for the particular application. Emerson is not in a position to evaluate or
guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration,
or materials of construction selected.
Engineered solutions
When standard model codes are not sufficient to fulfill requirements, please consult the factory to explore possible
Engineered Solutions. This is typically, but not exclusively, related to the choice of wetted materials or the design of a
process connection. These Engineered Solutions are part of the expanded offerings and may be subject to additional
delivery lead time. For ordering, factory will supply a special R-labeled numeric option code that should be added at the
end of the standard model string.
Electrical connection
½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit/cable adapter or PG 13.5 conduit/cable adapter.
Recommended output cabling is twisted shielded pairs, 18-12 AWG.
Housing material
Polyurethane-covered Aluminum or SST Grade CF8M (ASTM A743)
Ingress protection
NEMA® 4X, IP 66, IP 67
www.Emerson.com 31
Rosemount 3300 Level Transmitter September 2024
Factory sealed
Yes
Weight
■ Aluminum transmitter head: 5.5 lb (2.5 kg)
■ SST transmitter head: 11 lb (5 kg)
Tank connection
The tank connection consists of a tank seal, a flange, Tri Clamp, or NPT or BSPP (G) threads.
Flange dimensions
Follows ASME B16.5, JIS B2220, and EN 1092-1 standards for blind flanges.
Related information
Standard flanges
Proprietary flanges
Vented flanges
Available with Masoneilan and Fisher vented flanges. Vented flanges must be ordered as accessories with a 1½-in. NPT
threaded process connection (code RA). As an alternative to a vented flange, it is possible to use a flushing connection
ring on top of the standard nozzle.
32 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Probes
Probe versions
Coaxial, rigid single lead, and flexible single lead.
For interface measurements, rigid single probe is the best choice for chamber mounting. The coaxial probe is the
preferred choice for clean, low dielectric constant liquids.
For guidelines on which probe to select depending on application, see the Rosemount 3300 Reference Manual.
Total probe length
This is defined from the Upper Reference Point to the end of the probe (weight included, if applicable).
Figure 13: Total Probe Length
$ % & '
A. NPT
B. BSPP (G)
C. Flange
D. Tri Clamp
E. Upper reference point
F. Total probe length
Select the probe length according to the required measuring range (the probe must be hung and fully extended
through the entire distance where level readings are desired).
Cut-to-fit probes
All probes can be cut in field except for the PTFE covered probe.
However, there are some restrictions for the coaxial probe: Probes over 4.1 ft. (1.25 m) can be cut up to 2 ft. (0.6 m).
Shorter probes can be cut to the minimum length of 1.3 ft. (0.4 m).
Minimum and maximum probe length
Rigid single lead (0.3 in./8 mm) 1.3 to 9.8 ft. (0.4 to 3 m)
Rigid single lead (0.5 in./13 mm) 1.3 to 19.7 ft. (0.4 to 6 m)
www.Emerson.com 33
Rosemount 3300 Level Transmitter September 2024
Probe angle
0 to 90 degrees from vertical axis
Tensile strength
■ 0.16 in. (4 mm) Flexible single lead SST: 2698 lb (12 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy C-276: 1574 lb (7 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy 400: 1124 lb (5 kN)
Collapse load
■ 0.16 in. (4 mm) Flexible single lead SST: 3597 lb (16 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy C-276: 1798 lb (8 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy 400: 1349 lb (6 kN)
Sideway capacity
■ Rigid single lead/Segmented rigid single lead: 4.4 ft. lbf, 0.44 lb at 9.8 ft. (6 Nm, 0.2 kg at 3 m)
■ Coaxial: 73.7 ft. lbf, 3.7 lb at 19.7 ft. (100 Nm, 1.67 kg at 6 m)
1 316L/316 (EN 1.4404), PTFE, PFA, silicone grease, and O-ring materials
2 Alloy C-276 (UNS N10276), PTFE, PFA, silicone grease, and O-ring materials
3 Alloy 400 (UNS N04400), Alloy K500 (UNS N05500), PTFE, PFA, silicone grease, and
O-ring materials
Weight
Table 15: Flange and Probes
Item Weight
Rigid single lead probe (0.3-in./8 mm) 0.27 lb/ft. (0.4 kg/m)
Rigid single lead probe (0.5-in./13 mm) 0.71 lb/ft. (1.06 kg/m)
Item Weight
Standard weight for flexible single lead probe (0.16-in./4 mm) 0.88 lb (0.40 kg)
Short weight (W2) for flexible single lead probe (0.16-in./4 mm) 0.88 lb (0.40 kg)
Heavy weight (W3) for flexible single lead probe (0.16-in./4 mm) 2.43 lb (1.10 kg)
34 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Rigid single lead/Segmented rigid single lead(1) Smooth metal tank wall 4 in. (100 mm)
(1) Minimum clearance from tank bottom for the coaxial and rigid single probes is 0.2 in. (5 mm).
www.Emerson.com 35
Rosemount 3300 Level Transmitter September 2024
'
The transmitter can be mounted in nozzles by using an appropriate flange. It is recommended that the nozzle size is
within the dimensions given in Table 18.
Table 18: Nozzle Considerations for Optimal Performance
Recommended nozzle diameter (D) 6 in. (150 mm) > probe diameter
Minimum nozzle diameter (D)(1) 2 in. (50 mm) > probe diameter
Recommended nozzle height (H)(2) 4 in. (100 mm) + nozzle diameter(3) N/A
(1) The Trim Near Zone (TNZ) function may be necessary or an Hold Off Distance/Upper Null Zone (UNZ) setup may be required to mask
the nozzle.
(2) Longer nozzles may be used in certain applications. Consult your local Emerson representative for details.
(3) For nozzles taller than 4 in. (100 mm), the long stud version is recommended (option code LS) to prevent the flexible portion from
touching the edge of the nozzle.
Note
The probe must not be in contact with the nozzle (except for the coaxial probe).
36 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Table 19: Recommended and Minimum Chamber/Still Pipe Diameters for Different Probes
Rigid single/segmented rigid single 3 or 4 in. (75 or 100 mm) 2 in. (50 mm)
Flexible single 4 in. (100 mm) Consult your local Emerson representative
Note
Metal pipes are preferred, especially in applications with low dielectric constant, to avoid disturbances from objects
near the pipe.
Rosemount chamber
A Rosemount chamber allows external mounting of process level instrumentation. It supports a variety of process
connections, and optional drain and vent connections. The standard Rosemount chambers are designed according
to ASME B31.3. Rosemount chambers compliant with the Pressure Equipment Directive (PED) are available. Customer
specific engineered solutions for Rosemount chambers are available upon request. Use option code XC to order
together with the Rosemount 3300 Series Transmitters.
Use a centering disc the same diameter as the chamber if the probe length >3.3 ft. (1 m). See Table 22 for which disc to
use.
Existing chamber
A Rosemount 3300 Level Transmitter is the perfect replacement in an existing displacer chamber. Proprietary flanges
are offered, enabling use of existing chambers to make installation easy.
Figure 16: Existing Displacer Chamber
% &
www.Emerson.com 37
Rosemount 3300 Level Transmitter September 2024
Major torque-tube manufacture (249B, 249C, 249K, 249N, 259B) Displacer + 9 in. (229 mm)
(1) If flushing ring is used, add the ring height to the probe length.
(2) For other manufacturers, there are small variations. This is an approximate value; actual length should be verified.
(3) Lengths vary depending on model, SG, and rating, and should be verified.
For additional information, see the Replacing Displacers with Guided Wave Radar Technical Note.
'
38 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Table 22: Centering Disc Size Recommendation for Different Pipe Schedules
www.Emerson.com 39
Rosemount 3300 Level Transmitter September 2024
For clean liquids, use a coaxial probe to reduce effect of potential electrical disturbances.
Figure 19: Coaxial Probe in an Open-Air Application
For optimal single lead probe performance in non-metallic tanks, the probe must be mounted with a metal flange, or
screwed in to a metal sheet (d > 14 in./350 mm) if a threaded version is used.
Figure 20: Mounting in Non-Metallic Tanks
$ %
A. Metal flange
B. Metal sheet (d > 14 in./350 mm)
40 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
■ Probe tie-down is recommended if the probe can move to within 1 ft. (30 cm) of any object during operations
■ In order to stabilize the probe for side forces, it is possible to fix or guide the probe to the tank bottom
See the Rosemount 3300 Reference Manual for more mechanical installation information.
Product certifications
See the Rosemount 3300 Product Certifications document for detailed information on the existing approvals and
certifications.
www.Emerson.com 41
Rosemount 3300 Level Transmitter September 2024
Dimensional drawings
Figure 22: Rigid Single Lead Probe with Flange Connection
6.8 (173)
4.5 (113)
9.5 (241)
42 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
4.5 (113)
E E
F F
A. G 1/1½ inch
B. NPT 1/1½/2 inch
C. ½ - 14 NPT; optional adapters: M20x1.5
D. s52/s60
E. L ≤ 10 ft. (3 m); L ≤ 20 ft. (6 m) for Ø 0.51 (13)
F. Ø 0.31 (8) or Ø 0.51 (13) for SST and Alloy probes; Ø 0.47 (12) for PTFE covered probe
G. s52
Dimensions are in inches (millimeters).
www.Emerson.com 43
Rosemount 3300 Level Transmitter September 2024
Figure 24: Segmented Rigid Single Lead Probe with Flange Connection
6.8 (173)
4.5 (113)
9.5 (241)
0.6 (15)
15.2 (385)
31.5 (800)
Ø 0.51 (13) D
44 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Figure 25: Segmented Rigid Single Lead Probe with Threaded Connection
6.8 (173)
4.5 (113)
9.5 (241)
C F
1.1 (27)
15.2 (385)
31.5 (800)
Ø 0.51 (13)
E
www.Emerson.com 45
Rosemount 3300 Level Transmitter September 2024
4.5 (113)
9.5 (241)
B
A
G
F
C
5.5 (140)
2 (50)
D
Ø 1.5 (37.5) Ø 1.5 (37.5)
A. L ≤ 77 ft. (23.5 m)
B. Ø 0.16 (4) for SST probe; Ø 0.28 (7) for PTFE covered probe
C. 5.5 (140) for SST probe; 17.1 (435) for PTFE covered probe
D. Ø 0.86 (22) for SST probe; Ø 0.88 (22.5) for PTFE covered probe
E. The PTFE covered probe is designed with a protective plate.
F. Short weight (option W2)
G. Heavy weight (option W3)
Dimensions are in inches (millimeters).
46 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
4.5 (113)
2.4 (62)
1.1 (27)
F F
D D K
J
G 5.5 (140)
2 (50)
A. G 1/1½ in.
B. NPT 1/1½/2 in.
C. ½ - 14 NPT; optional adapters: M20x1.5
D. L ≤ 77 ft. (23.5 m)
E. s52/s60
F. Ø 0.16 (4) for SST probe; Ø 0.28 (7) for PTFE covered probe
G. 5.5 (140) for SST probe; 17.1 (435) for PTFE covered probe
H. Ø 0.86 (22) for SST probe; Ø 0.88 (22.5) for PTFE covered probe
I. 1 in./1½ in.: s52; 2 in.: s60
J. Short weight (option W2)
K. Heavy weight (option W3)
Dimensions are in inches (millimeters).
www.Emerson.com 47
Rosemount 3300 Level Transmitter September 2024
4.5 (113)
9.5 (241)
B B C
1.1 (28)
A. L ≤ 20 ft. (6 m)
B. For stainless steel the probe is welded to the flange.
C. The alloy probes are designed with a protective plate.
Dimensions are in inches (millimeters).
48 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
4.5 (113)
9.5 (241) F
9.5 (241)
E
2.4 (62)
1.1 (27)
D D
A. G 1/1½ in.
B. NPT 1/1½/2 in.
C. ½ - 14 NPT; optional adapters: M20x1.5
D. L ≤ 20 ft. (6 m)
E. s52/s60
F. 1 in./1½ in.: s52; 2 in.: s60
Dimensions are in inches (millimeters).
www.Emerson.com 49
Rosemount 3300 Level Transmitter September 2024
E
5. 2 (133)
C D
0.87 (22)
0.35 (9)
2.76
(70)
2.24
(57)
50 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
5.2 (133)
B
C
A. 3, 6, 9 ft. (1, 2, or 3 m)
B. Rmin: 1.4 (35)
C. Hmin: 7.3 (185)
Dimensions are in inches (millimeters).
Standard flanges
Figure 32: Flange Connection
A B C
D F
A. Forged one-piece
B. Welded construction
C. Protective plate design
D. Weld
E. Backing flange
F. Protective plate
www.Emerson.com 51
Rosemount 3300 Level Transmitter September 2024
Proprietary flanges
Figure 33: Proprietary Flanges
% %
* . ' * . '
% %
D: Outside diameter
B1: Flange thickness with gasket surface
B2: Flange thickness without gasket surface
F=B1-B2: Gasket surface thickness
G: Gasket surface diameter
# Bolts: Number of bolts
K: Bolt hole circle diameter
Note
Dimensions may be used to aid in the identification of installed flanges. It is not intended for manufacturing use.
52 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
Fisher 249B/259B(2)
™
9.00 (228.6) 1.50 (38.2) 1.25 (31.8) 0.25 (6.4) 5.23 (132.8) 8 7.25 (184.2)
Fisher 249C(3) 5.69 (144.5) 0.94 (23.8) 1.13 (28.6) -0.19 (-4.8) 3.37 (85.7) 8 4.75 (120.65)
Masoneilan ™(2)
7.51(191.0) 1.54 (39.0) 1.30 (33.0) 0.24 (6.0) 4.02 (102.0) 8 5.87 (149.0)
'+ $
'L
www.Emerson.com 53
Rosemount 3300 Level Transmitter September 2024
54 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter
www.Emerson.com 55
00813-0100-4811
Rev. JF
September 2024