0% found this document useful (0 votes)
8 views56 pages

Product Data Sheet Rosemount 3300 Level Transmitter en 73582

The Rosemount™ 3300 Level Transmitter utilizes guided wave radar technology for accurate level measurement, requiring minimal maintenance due to its lack of moving parts. It offers high application flexibility with various process connections and probe styles, making it suitable for diverse liquid storage applications. The device features easy installation and integration, along with advanced signal processing for reliable performance under changing process conditions.

Uploaded by

Indra SUdirman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views56 pages

Product Data Sheet Rosemount 3300 Level Transmitter en 73582

The Rosemount™ 3300 Level Transmitter utilizes guided wave radar technology for accurate level measurement, requiring minimal maintenance due to its lack of moving parts. It offers high application flexibility with various process connections and probe styles, making it suitable for diverse liquid storage applications. The device features easy installation and integration, along with advanced signal processing for reliable performance under changing process conditions.

Uploaded by

Indra SUdirman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

Product Data Sheet

00813-0100-4811, Rev JF
September 2024

Rosemount™ 3300 Level Transmitter


Guided Wave Radar

■ Accurate, direct level measurement virtually unaffected by process conditions


■ Minimized maintenance with no moving parts and no re-calibration required
■ Fewer process penetrations and reduced installation costs with a MultiVariable™ level and interface transmitter
■ Easy installation and commissioning through two-wire technology and user-friendly configuration
■ Versatile and easy-to-use transmitter with field proven reliability
■ High application flexibility with a wide range of process connections, probe styles, and accessories
Rosemount 3300 Level Transmitter September 2024

Proven, reliable, and easy to use guided wave radar


Measurement principle
Low power, nano-second microwave pulses are guided down a probe submerged in the process media. When a
microwave pulse reaches a medium with a different dielectric constant, part of the energy is reflected back to the
transmitter.
The transmitter uses the residual wave of the first reflection for measuring the interface level. Part of the wave, which
was not reflected at the upper product surface, continues until it is reflected at the lower product surface. The speed of
this wave depends fully on the dielectric constant of the upper product.
The time difference between the transmitted and the reflected pulse is converted into a distance, and the total level or
interface level is then calculated. The reflection intensity depends on the dielectric constant of the product: the higher
dielectric constant value, the stronger reflection.
Figure 1: Measurement Principle

A. Reference pulse
B. Level
C. Interface level

Contents
Proven, reliable, and easy to use guided wave radar.................................................................................................................... 2
Ordering information.........................................................................................................................................................................5
Specifications.................................................................................................................................................................................... 18
Installation and mounting considerations....................................................................................................................................35
Product certifications....................................................................................................................................................................... 41
Dimensional drawings..................................................................................................................................................................... 42

2 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Guided wave radar technology benefits


■ Direct level measurement means no compensation needed for changing process conditions (i.e. density,
conductivity, temperature, and pressure)
■ No moving parts and no re-calibration result in minimized maintenance
■ Handles vapor and turbulence well
■ Suitable for small tanks, difficult tank geometry, internal obstacles, and unaffected by the mechanical design of
chambers
■ Allows for easy upgrade
■ Top down installation minimizes risk for leakages

Special Rosemount 3300 features


Proven high reliability increases uptime
■ First 2-wire level and interface transmitter with field proven reliability
■ More than 120,000 units installed
■ Advanced signal processing for reliable measurement
■ Accurate level unaffected by changing process conditions

High application flexibility


■ Suitable for most liquid storage and monitoring level and interface applications
■ A wide selection of process connections and probe styles
■ Remote mounting, mounting bracket, Emerson Wireless 775 THUM™ Adapter, HART® Tri-Loop™, and probe
centering discs accessories
■ Easy retrofit in existing chambers or available as complete assembly with high quality Rosemount chambers

Robust design reduces costs and increases safety


■ Leakage prevention and reliable performance under challenging conditions
■ Detachable transmitter head allows tank to remain sealed
■ Dual Compartment housing separates cable connections and electronics

www.Emerson.com 3
Rosemount 3300 Level Transmitter September 2024

Easy installation and plant integration


■ Seamless system integration with HART, Modbus®, or IEC 62591 (WirelessHART®) with the THUM adapter
■ Allows for easy swap by matching existing tank connections
■ Cut-to-fit probes
■ Long lengths of rigid probes for robust measurements becomes cost-effective and practical to ship, store and
install with the segmented probe option (code 4S)
■ Pre-configured or user-friendly configuration with wizard, autoconnect, dielectric calculator, and on-line help
■ MultiVariable – measures simultaneously level and interface, resulting in fewer process penetrations and reduces
installation and wiring cost

Minimized maintenance reduces cost


■ No mechanical moving parts that require maintenance
■ User-friendly software provides easy on-line troubleshooting with echo curve tool and logging
■ Adjustments without opening tank
■ No re-calibration or compensation needed due to changing process conditions

Easy replacement of old technology and best fit for chambers


■ Less need for maintenance reduces costs and improves measurement availability
■ Reliable measurement, independent of density, turbulence, and vibrations
■ Unaffected by the mechanical configuration of the chamber
■ Wide range of options to find the best fit in existing chamber or a complete assembly with Rosemount CMB high
quality chambers

Access information when you need it with asset tags


Newly shipped devices include a unique QR code asset tag that enables you to access serialized information directly
from the device. With this capability, you can:
■ Access device drawings, diagrams, technical documentation, and troubleshooting information in your MyEmerson
account
■ Improve mean time to repair and maintain efficiency
■ Ensure confidence that you have located the correct device
■ Eliminate the time-consuming process of locating and transcribing nameplates to view asset information

4 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Ordering information
Online product configurator
Many products are configurable online using our product configurator.
Select the Configure button or visit Emerson.com/global to start. With this tool's built-in logic and continuous validation,
you can configure your products more quickly and accurately.

Specifications and options


Specification and selection of product materials, options, and/or components must be made by the purchaser of the
equipment. See the Material selection section for more information.

Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model
code is shown in Figure 2.
Figure 2: Model Code Example
3302 H S 1 S 1 V 4B E 10 27 RA I7 M5 B2 WR3
1 2

1. Required model components (choices available on most)


2. Additional options (variety of features and functions that may be added to products)

Optimizing lead time


The starred offerings (★) represent the most common options and should be selected for the fastest delivery times.
The non-starred offerings are subject to additional delivery lead time.

www.Emerson.com 5
Rosemount 3300 Level Transmitter September 2024

Rosemount 3300 Level Transmitter


Rosemount 3301 and 3302 Guided Wave Radar Level transmitters are versatile and easy-to-use with field
proven measurement capabilities.
■ High application flexibility with a wide range of probe styles, process connections, and materials
■ HART® 4-20 mA, Modbus®, or IEC 62591 (WirelessHART®) with the THUM adapter
■ Radar Configuration Tool software package included for easy commissioning and troubleshooting

Rosemount 3301 Level Transmitter:


CONFIGURE > VIEW PRODUCT >

Rosemount 3302 Level Transmitter:


CONFIGURE > VIEW PRODUCT >

Required model components


Model

Code Description

3301 Guided Wave Radar Level Transmitter (interface available for fully submerged probe) ★

3302 Guided Wave Radar Level and Interface Transmitter ★

Signal output

Code Description

H 4-20 mA with digital signal based on HART Revision 5 protocol ★

M(1) RS-485 with Modbus communication ★

(1) Requires external 8-30 Vdc power supply.

Related information
4-20 mA HART
Modbus

Housing material

Code Description

A Polyurethane-covered Aluminum ★

S Stainless Steel, Grade CF8M (ASTM A743)

Conduit / cable threads

Code Description

1 ½–14 NPT 1 plug included ★

2 M20 x 1.5 adapter 1 adapter and 1 plug included ★

G(1)(2) Metal cable gland (½ - 14 NPT) 2 glands and 1 plug included ★

(1) Not available with explosion-proof or flameproof approvals.


(2) Minimum temperature is -20 °C (-4 °F).

6 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Operating temperature and pressure


Process seal rating. Final rating depends on flange and O-ring selection.

Code Description Probe type

S Design and operating temperature: Design and operating pressure: 3301: All ★
-40 to 302 °F -15 to 580 psig 3302: 3B, 4A, 4B, and 4S
(-40 to 150 °C) (-1 to 40 bar)

Related information
Process temperature and pressure rating

Material of construction; process connection/probe


For other materials, consult the factory.

Code Description Probe type

1(1) 316/316L/EN 1.4404 3301: All ★


3302: 3B, 4A, 4B, and 4S

2 Alloy C-276 (UNS N10276). With plate design if flanged version. 3301: 3A, 3B, 4A, 4B, 5A, and 5B
3302: 3B, 4A, 4B, 5A, and 5B

3 Alloy 400 (UNS N04400). With plate design if flanged version. 3301: 3A, 3B, 4A, 4B, 5A, and 5B
3302: 3B, 4A, and 4B

7 PTFE covered probe and flange. With plate design. 3301: 4A and 5A, Flanged version
3302: 4A, Flanged version

8 PTFE covered probe 3301: 4A and 5A


3302: 4A

(1) ASME flanges dual certified 316/316L.

Sealing O-ring material


For other materials, consult the factory.

Code Description

V Fluoroelastomer (FKM) ★

E Ethylene Propylene (EPDM) ★

K Kalrez Perfluoroelastomer (FFKM)


®

B Nitrile Butadiene (NBR) ★

Probe type, model 3301

Code Description Process connection Probe lengths

3B Coaxial, perforated. For level and interface Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m) ★
measurement. Max: 19 ft. 8 in. (6 m)

4B(1) Rigid Single Lead 0.5 in. (13 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m) ★
Tri-Clamp® Max: 19 ft. 8 in. (6.0 m)

5A Flexible Single Lead with weight Flange / 1-in., 1½-in., 2-in. Thread / Min.: 3 ft. 4 in. (1 m) ★
Tri-Clamp Max: 77 ft. (23.5 m)

3A Coaxial (for level measurement) Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m)
Max: 19 ft. 8 in. (6 m)

www.Emerson.com 7
Rosemount 3300 Level Transmitter September 2024

Code Description Process connection Probe lengths

4A Rigid Single Lead 0.3 in. (8 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
Tri-Clamp Max: 9 ft. 10 in. (3 m)

4S Segmented Rigid Single Lead 0.5 in. Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
(13 mm) Tri-Clamp Max: 19 ft. 8 in. (6.0 m)

5B Flexible Single Lead with chuck Flange / 1-in., 1½-in., 2-in. Thread / Min.: 3 ft. 4 in. (1 m)
Tri-Clamp Max: 77 ft. (23.5 m)

(1) Available in SST. Consult the factory for other materials.

Probe type, model 3302

Code Description Process connection Probe lengths

3B Coaxial, perforated. For level and interface Flange / 1-in., 1½-in., 2-in. Thread Min.: 1 ft. 4 in. (0.4 m) ★
measurement. Max: 19 ft. 8 in. (6 m)

4B(1) Rigid Single Lead 0.5 in. (13 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m) ★
Tri-Clamp Max: 19 ft. 8 in. (6.0 m)

4A Rigid Single Lead 0.3 in. (8 mm) Flange / 1-in., 1½-in., 2-in. Thread / Min.: 1 ft. 4 in. (0.4 m)
Tri-Clamp Max: 9 ft. 10 in. (3 m)

4S Segmented Rigid Single Lead 0.5 in. Flange / 1-in., 1½-in., 2-in.Thread / Min.: 1 ft. 4 in. (0.4 m)
(13 mm) Tri-Clamp Max: 19 ft. 8 in. (6.0 m)

(1) Available in SST. Consult the factory for other materials.

Probe length units

Code Description

E English (feet, inches) ★

M Metric (meters, centimeters) ★

Total probe length (feet/m)


Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters,
depending on selected probe length unit. If tank height is unknown, please round up to an even length when ordering.
Probes can be cut to exact length in field. Maximum allowable length is determined by process conditions.

Code Description

XX 0 - 77 ft. or 0-23 m ★

Total probe length (inch/cm)


Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters,
depending on selected probe length unit. If tank height is unknown, please round up to an even length when ordering.
Probes can be cut to exact length in field. Maximum allowable length is determined by process conditions.

Code Description

XX 0 - 11 in. or 0-99 cm ★

Process connection - size/type


Consult factory for other process connections.

8 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Code Description

ASME B16.5 flanges(1)(2)

AA(3) 2-in. Class 150, RF (Raised Face Type) ★

AB(3) 2-in. Class 300, RF (Raised Face Type) ★

BA(3) 3-in. Class 150, RF (Raised Face Type) ★

BB(3) 3-in. Class 300, RF (Raised Face Type) ★

CA(3) 4-in. Class 150, RF (Raised Face Type) ★

CB(3) 4-in. Class 300, RF (Raised Face Type) ★

DA 6-in. Class 150, RF (Raised Face Type)

EN 1092-1 flanges(1)(4)

HB DN50, PN40, Type A flat face ★

IA DN80, PN16, Type A flat face ★

IB DN80, PN40, Type A flat face ★

JA DN100, PN16, Type A flat face ★

JB DN100, PN40, Type A flat face ★

KA DN150, PN16, Type A flat face

JIS flanges(1)(4)

UA 50A, 10K, RF (Raised Face Type) ★

VA 80A, 10K, RF (Raised Face Type) ★

XA 100A, 10K, RF (Raised Face Type) ★

UB 50A, 20K, RF (Raised Face Type)

VB 80A, 20K, RF (Raised Face Type)

XB 100A, 20K, RF (Raised Face Type)

YA 150A, 10K, RF (Raised Face Type)

YB 150A, 20K, RF (Raised Face Type)

ZA 200A, 10K, RF (Raised Face Type)

ZB 200A, 20K, RF (Raised Face Type)

Threaded connections(1) Probe type

RA 1½-in. NPT thread 3301: All ★


3302: 3B, 4A, 4B, and 4S

RC 2-in. NPT thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B ★
3302: 3B, 4A, 4B, and 4S

RB 1-in. NPT thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B
3302: 3B, 4A, 4B, and 4S

SA(4) 1½-in. BSP (G 1½-in.) thread 3301: All


3302: 3B, 4A, 4B, and 4S

SB(4) 1-in. BSP (G 1-in.) thread 3301: 3A, 3B, 4A, 4B, 4S, 5A, and 5B
3302: 3B, 4A, 4B, and 4S

Tri-Clamp fittings(1)(5) Probe type

FT 1½-in. Tri-Clamp 3301: 4A, 4B, 4S, 5A, and 5B


3302: 4A, 4B, and 4S

www.Emerson.com 9
Rosemount 3300 Level Transmitter September 2024

Code Description

AT 2-in. Tri-Clamp 3301: 4A, 4B, 4S, 5A, and 5B


3302: 4A, 4B, and 4S

BT 3-in. Tri-Clamp 3301: 4A, 4B, 4S, 5A, and 5B


3302: 4A, 4B, and 4S

CT 4-in. Tri-Clamp 3301: 4A, 4B, 4S, 5A, and 5B


3302: 4A, 4B, and 4S

Proprietary flanges

TF Fisher™ - proprietary 316/316L (for 249B, 259B chambers) Torque Tube Flange ★

TT Fisher - proprietary 316/316L (for 249C chambers) Torque Tube Flange ★

TM Masoneilan - proprietary 316/316L Torque Tube Flange



(1) Available in material 316/316L and EN 1.4404. For other materials consult the factory.
(2) Design according to ASME B31.3. No code stamp or ASME certificate available.
(3) Forged one-piece flange provided for Material of construction code 1, 7 or 8, together with Probe type code 3A, 3B, 4A, 4B, 4S, 5A, or
5B. Welded construction provided for other combinations.
(4) Not available with Canadian Registration Number (CRN).
(5) Follows ISO 2852 standard.

Related information
Process temperature and pressure rating
Flange rating
Tri Clamp rating

Hazardous locations certifications

Code Description

NA No Hazardous Locations Certifications ★

E1(1) ATEX Flameproof ★

E3(1) China Flameproof ★

E5(1) USA Explosion-proof ★

E6(1) Canadian Explosion-proof ★

E7(1) IECEx Flameproof ★

I1 ATEX Intrinsic Safety ★

I3 China Intrinsic Safety ★

I5 USA Intrinsic Safety and Non-Incendive ★

I6 Canadian Intrinsic Safety and Non-Incendive ★

I7 IECEx Intrinsic Safety ★

EW India PESO Flameproof

IW India PESO Intrinsic Safety

KB(1) USA and Canadian Explosion-proof

(1) Probes are intrinsically safe.

10 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Additional options
Display

Code Description

M1 Integral digital display ★

Hydrostatic testing
Available for tank connection with flange.

Code Description

P1 Hydrostatic testing, including certificate ★

Materials certification
Available for probe type 3A, 3B, 4A, 4B, and 4S.

Code Description

N2 NACE® material recommendation per NACE MR0175/ISO 15156 and NACE MR0103/ISO 17945 ★

Installation options

Code Description

LS(1) Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle. Standard stud length is ★
3.9 in (100 mm).

BR 316L Mounting Bracket for 1½-in. NPT Process Connection (RA)

(1) Not available with PTFE covered probes.

Weight and anchoring options for flexible single probes

Code Description

W3 Heavy Weight (for most applications) ★

W2(1) Short Weight (when measuring close to the probe end)

(1) Only for Material of Construction code 1 and Probe Type 5A.

Related information
Dimensional drawings

www.Emerson.com 11
Rosemount 3300 Level Transmitter September 2024

Centering disc
Available for SST, Alloy C-276, and Alloy 400 probes, types 4A, 4B, 4S, and 5A.
Not available with PTFE covered probes (Material of Construction codes 7 and 8).

Code Description

S2(1) 2-in. Centering disc ★

S3(1) 3-in. Centering disc ★

S4(1) 4-in. Centering disc ★

P2 2-in. Centering disc PTFE ★

P3 3-in. Centering disc PTFE ★

P4 4-in. Centering disc PTFE ★

S6(1) 6-in. Centering disc

S8(1) 8-in. Centering disc

P6 6-in. Centering disc PTFE

P8 8-in. Centering disc PTFE

(1) Centering disc in same material as probe material of construction.

Related information
Centering disc for pipe installations

Remote housing
Requires software version 10 or higher.

Code Description

B1 1 m/3.2 ft. Remote housing mounting cable and 316L bracket

B2 2 m/6.5 ft. Remote housing mounting cable and 316L bracket

B3 3 m/9.8 ft. Remote housing mounting cable and 316L bracket

Related information
Dimensional drawings

Factory configuration

Code Description

C1 Factory configuration per Configuration Data Sheet ★

Alarm limits

Code Description

C4 NAMUR alarm and saturation levels, high alarm ★

C5 NAMUR alarm and saturation levels, low alarm ★

C8(1) Standard Rosemount alarm and saturation levels, low alarm ★

(1) The standard alarm setting is high.

12 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Special quality assurance

Code Description

Q4 Calibration data certificate ★

Material traceability certification


Certificate includes all pressure retaining wetted parts.

Code Description

Q8 Material traceability certification consistent with ISO10474-3.1:2013 / EN10204-3.1:2004 ★

Welding procedure qualification record documentation


Only applies to flanged process connections with welded construction or protective plate design.
Weldings in accordance with EN/ISO standards.

Code Description

Q66 Welding Procedure Qualification Record (WPQR) ★

Dye penetration test certificate


Only applies to flanged process connections with welded construction or protective plate design.

Code Description

Q73 Certificate of liquid penetrant inspection ★

Positive material identification certificate

Code Description

Q76 Positive material identification certificate of conformance ★

Overfill prevention

Code Description

U1 Overfill prevention according to WHG/TUV ★

Assemble/consolidate to chamber
Selecting the XC option code on the Rosemount 3300 and a Rosemount chamber will result in matching, consolidating,
configuring, and shipping of the two products in one crate. Note that the flange bolts are only hand-tightened. Long
rigid single lead probes (>8 ft./2.5 m) are ship separately in order to reduce transportation risk damage.

Code Description

XC Consolidate to Chamber ★

Specials

Code Description

RXXXX Custom engineered solutions beyond standard model codes. Consult factory for details.

www.Emerson.com 13
Rosemount 3300 Level Transmitter September 2024

Accessories

Weight kit
Item number Description

03300-7001-0003 Weight kit flexible 4 mm single lead

03300-7001-0004 Weight kit flexible 6 mm single lead

Centering discs for rigid single lead probe (d=0.3 in./8 mm)
If a centering disc is required for a flanged probe, the centering disc can be ordered with options Sx or Px in the model
code. If a centering disc is required for a threaded connection, or as a spare part, it should be ordered using the item
numbers listed in this table.
For other materials, consult the factory.

Item number Description Outer diameter

03300-1655-0001 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★

03300-1655-0006 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★

03300-1655-0002 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★

03300-1655-0007 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★

03300-1655-0003 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★

03300-1655-0008 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★

03300-1655-0004 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)

03300-1655-0009 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)

03300-1655-0005 Kit, 8-in. Centering disc, SST 7.40 in. (188 mm)

03300-1655-0010 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)

Related information
Centering disc for pipe installations

Centering discs for rigid single lead probe (d=0.5 in./13 mm)
If a centering disc is required for a flanged probe, the centering disc can be ordered with options Sx or Px in the model
code. If a centering disc is required for a threaded connection, or as a spare part, it should be ordered using the item
numbers listed in this table.
For other materials, consult the factory.

Item number Description Outer diameter

03300-1655-0301 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★

03300-1655-0306 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★

03300-1655-0302 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★

03300-1655-0307 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★

03300-1655-0303 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★

03300-1655-0308 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★

03300-1655-0304 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)

03300-1655-0309 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)

14 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Item number Description Outer diameter

03300-1655-0305 Kit, 8-in. Centering disc, SST 7.40 in. (188 mm)

03300-1655-0310 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)

Related information
Centering disc for pipe installations

Snap-on centering discs for flexible single lead probes


Maximum temperature for the snap-on centering discs is 392 °F (200 °C).

Item number Description

03300-1658-0001 Kit, 2- to 4-in. snap-on centering disc, PEEK, 1 pc

03300-1658-0002 Kit, 2- to 4-in. snap-on centering disc, PEEK, 3 pcs

03300-1658-0003 Kit, 2- to 4-in. snap-on centering disc, PEEK, 5 pcs

Centering discs for flexible single lead probes


If a centering disc is required for a flanged probe, the centering disc can be ordered with options Sx or Px in the model
code. If a centering disc is required for a threaded connection, or as a spare part, it should be ordered using the item
numbers listed in this table.
For other materials, consult the factory.

Item number Description Outer diameter

03300-1655-1001 Kit, 2-in. Centering disc, SST 1.8 in. (45 mm) ★

03300-1655-1006 Kit, 2-in. Centering disc, PTFE 1.8 in. (45 mm) ★

03300-1655-1002 Kit, 3-in. Centering disc, SST 2.7 in. (68 mm) ★

03300-1655-1007 Kit, 3-in. Centering disc, PTFE 2.7 in. (68 mm) ★

03300-1655-1003 Kit, 4-in. Centering disc, SST 3.6 in. (92 mm) ★

03300-1655-1008 Kit, 4-in. Centering disc, PTFE 3.6 in. (92 mm) ★

03300-1655-1004 Kit, 6-in. Centering disc, SST 5.55 in. (141 mm)

03300-1655-1009 Kit, 6-in. Centering disc, PTFE 5.55 in. (141 mm)

03300-1655-1005 Kit, 8-in. Centering disc, SST, 7.40 in. (188 mm)

03300-1655-1010 Kit, 8-in. Centering disc, PTFE 7.40 in. (188 mm)

Related information
Centering disc for pipe installations

Centering discs for mounting between segments (probe type 4S only)


Item number Description Outer diameter

03300-1656-1002 2-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 1.8 in. (45 mm)

03300-1656-1003 3-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 2.7 in. (68 mm)

03300-1656-1004 4-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 3.6 in. (92 mm)

03300-1656-1006 6-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 5.55 in. (141 mm)

www.Emerson.com 15
Rosemount 3300 Level Transmitter September 2024

Item number Description Outer diameter

03300-1656-1008 8-in. Centering disc (1 pc), PTFE, Segmented rigid single lead 7.40 in. (188 mm)

03300-1656-3002 2-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 1.8 in. (45 mm)

03300-1656-3003 3-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 2.7 in. (68 mm)

03300-1656-3004 4-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 3.6 in. (92 mm)

03300-1656-3006 6-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 5.55 in. (141 mm)

03300-1656-3008 8-in. Centering disc (3 pcs), PTFE, Segmented rigid single lead 7.40 in. (188 mm)

03300-1656-5002 2-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 1.8 in. (45 mm)

03300-1656-5003 3-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 2.7 in. (68 mm)

03300-1656-5004 4-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 3.6 in. (92 mm)

03300-1656-5006 6-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 5.55 in. (141 mm)

03300-1656-5008 8-in. Centering disc (5 pcs), PTFE, Segmented rigid single lead 7.40 in. (188 mm)

Segmented rigid single lead probe spare part kit


Item number Description

03300-0050-0001 15.2 in. / 385 mm Segment for Top connection (1 pc)

03300-0050-0002 31.5 in. / 800 mm Segment (1 pc)

03300-0050-0003 31.5 in. / 800 mm Segment (3 pcs)

03300-0050-0004 31.5 in. / 800 mm Segment (5 pcs)

03300-0050-0005 31.5 in. / 800 mm Segment (12 pcs)

Vented flanges
1-½ in. NPT threaded connection (RA) is required.
Not available with Canadian Registration Number (CRN).

Item number Description

03300-1812-0092 Fisher™ (249B, 259B), one ¼-in. NPT connection, 316/316L

03300-1812-0093 Fisher (249C), one ¼-in. NPT connection, 316/316L

03300-1812-0091 Masoneilan™, one ¼-in. NPT connection, 316/316L

Flushing connection rings


Not available with Canadian Registration Number (CRN).

Item number Description

DP0002-2111-S6 2-in. ANSI, one ¼-in. NPT connection, 316L

DP0002-3111-S6 3-in. ANSI, one ¼-in. NPT connection, 316L

DP0002-4111-S6 4-in. ANSI/DN100, one ¼-in. NPT connection, 316L

DP0002-5111-S6 DN50, one ¼-in. NPT connection, 316L

DP0002-8111-S6 DN80, one ¼-in. NPT connection, 316L

16 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

HART modem and cables


Item number Description

03300-7004-0002 MACTek® VIATOR® HART Modem and cables (USB connection) ★

03300-7004-0001 MACTek VIATOR HART Modem and cables (RS232 connection) ★

Remote housing mounting spare part kit


Item number Description

03300-7006-0001 1 m / 3.2 ft. Remote Housing Mounting Cable and 316L Bracket

03300-7006-0002 2 m / 6.5 ft. Remote Housing Mounting Cable and 316L Bracket

03300-7006-0003 3 m / 9.8 ft. Remote Housing Mounting Cable and 316L Bracket

www.Emerson.com 17
Rosemount 3300 Level Transmitter September 2024

Specifications
Performance specifications

General
Reference conditions
Twin Lead probe, 77 °F (25 °C) water
Reference accuracy
± 0.2 in. (5 mm) for probes ≤16.4 ft. (5 m)
± 0.1% of measured distance for rigid probes >16.4 ft. (5 m)
± 0.15% of measured distance for flexible probes >16.4 ft. (5 m)
For probes with spacers, the accuracy may deviate close to the spacers. Accuracy may be affected by remote housing.
Repeatability
± 0.04 in. (1 mm)(1)
Ambient temperature effect
Less than 0.01% of measured distance per °C
Update interval
Minimum 1 update per second

Environment
Vibration resistance
■ Polyurethane-covered aluminum housing: IEC 60770-1
■ SST housing: IACS E10

Electromagnetic compatibility
Emission and Immunity: meets EN 61326-1:2013, class A equipment intended for use in industrial locations if installed
in metallic vessels or still-pipes.
When rigid/flexible single probes are installed in non-metallic or open vessels, influence of strong electromagnetic
fields might affect measurements.

Related information
Installation in non-metallic tanks and open-air applications

CE-mark
The 4–20 mA HART version (Output Option Code H) complies with applicable directives (EMC and ATEX).
Built-in lightning protection
Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4

(1) In accordance with IEC 60770-1. See the IEC 60770-1 standard for a definition of radar specific performance parameters and if applicable
corresponding test procedures.

18 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Contamination/product build-up
■ Single lead probes are preferred when there is a risk of contamination (because build-up can result in the product
bridging between the inner lead and outer pipe for the coaxial probe).
■ For viscous or sticky applications, PTFE probes are recommended. Periodic cleaning may also be required.
■ For viscous or sticky applications, it is not recommended to use centering discs mounted along the single lead
probe.
■ Maximum error due to coating is 1 to 10% depending on probe type, dielectric constant, coating thickness, and
coating height above product surface.
Table 1: Maximum Recommended Viscosity and Contamination/Build-up

Probe type Maximum viscosity Contamination/build-up

Single lead 8000 cP(1) Build-up allowed

Coaxial 500 cP Not recommended

(1) Consult your local Emerson representative in the case of agitation/turbulence and high viscous products.

Measuring range
Measuring range and minimum dielectric constant
See Table 2 and Table 3 for each probe’s measuring range and minimum dielectric constant. Due to the measuring
range depending on the application and factors described below, the values are a guideline for clean liquids. For more
information, ask your local Emerson representative.
Note
See Table 4 for the measuring range when using the Remote Housing.

Different parameters (factors) affect the echo and therefore the maximum measuring range differs depending on
application according to:
■ Disturbing objects close to the probe.
■ Media with higher dielectric constant (εr) gives better reflection and allows a longer measuring range.
■ Surface foam and particles in the tank atmosphere may affect measuring performance.
■ Heavy product build-up or contamination on the probe should be avoided since it can reduce measuring range and
might cause erroneous level readings.
Table 2: Maximum Measuring Range

Probe type Maximum measuring range

Rigid single lead/segmented rigid single lead 9 ft. 10 in. (3 m) for 8 mm probes (code 4A)
19 ft. 8 in. (6 m) for 13 mm probes (code 4B)
19 ft. 8 in. (6 m) for 13 mm probes (code 4S)

Flexible single lead 77 ft. 1 in. (23.5 m)

Coaxial 19 ft. 8 in. (6 m)

Table 3: Minimum Dielectric Constant

Probe type Minimum dielectric constant

Rigid single lead/segmented rigid single lead 2.5(1)


(1.7 if installed in a metallic bypass or stilling well)

www.Emerson.com 19
Rosemount 3300 Level Transmitter September 2024

Table 3: Minimum Dielectric Constant (continued)


Probe type Minimum dielectric constant

Flexible single lead 2.5 up to 36 ft. (11 m)(2)


5.0 up to 66 ft. (20 m)
7.5 up to 77 ft. 1 in. (23.5 m)

Coaxial 1.5

(1) May be lower depending on installation.


(2) In pipes with a diameter less than 8 in. (20 cm), the minimum dielectric constant is 2.0.

Table 4: Measuring Range and Minimum Dielectric Constant when using Remote Housing

Rigid single lead/ Flexible single lead Coaxial


segmented rigid single
lead

Maximum measuring range 9 ft. 10 in. (3 m) for 8 mm 77 ft. 1 in. (23.5 m) 19 ft. 8 in. (6 m)
probes
14 ft. 9 in. (4.5 m) for 13
mm probes

Minimum dielectric constant with 1 m 2.7(1) 2.7 up to 36 ft. (11 m) 1.5


remote housing (2.0 if installed in a metallic 6 up to 66 ft. (20 m)
bypass or stilling well) 10 up to 72 ft. (22 m)

Minimum dielectric constant with 2 m 3.3(1) 3.2 up to 36 ft. (11 m) 1.6


remote housing (2.2 if installed in a metallic 8 up to 67 ft. (20.5 m)
bypass or stilling well)

Minimum dielectric constant with 3 m 3.8(1) 3.7 up to 36 ft. (11 m) 1.7


remote housing (2.5 if installed in a metallic 11 up to 62 ft. (19 m)
bypass or stilling well)

(1) May be lower depending on installation.

Interface measuring range


The maximum allowable upper product thickness/measuring range is primarily determined by the dielectric constants
of the two liquids.
Typical applications include interfaces between oil/oil-like and water/water-like liquids, with a low (<3) dielectric
constant for the upper product and a high (>20) dielectric constant for the lower product. For such applications, the
maximum measuring range is limited by the length of the coaxial and rigid single lead probes.
Transition zones
These zones are areas where measurements are non-linear or have reduced accuracy. If measurements are desired at
the very top of a tank, it is possible to mechanically extend the nozzle and use a coaxial probe. The upper transition
zone is then moved into the extension. See Table 5.
For a flexible single lead probe with chuck, the lower transition zone is measured upwards from the upper part of the
clamp.

20 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 3: Transition Zones

A
B

D D

A. Upper Reference Point


B. Upper Transition Zone
C. Maximum Recommended Measuring Range
D. Lower Transition Zone
E. Lower Reference Point

Table 5: Transition Zones

Dielectric Rigid single lead/ Flexible single lead Coaxial


Constant segmented rigid single
lead

Upper Transition Zone(1) 80 4 in. (10 cm) 5.9 in. (15 cm) 4 in. (10 cm)

2 4 in. (10 cm) 20 in. (50 cm) 4 in. (10 cm)

Lower Transition Zone(2) 80 2 in. (5 cm) 2 in. (5 cm)(3)(4) 1.2 in. (3 cm)

2 4 in. (10 cm) 6.3 in. (16 cm) - long weight, 2 in. (5 cm)
short weight, and chuck(4)(5)

(1) The distance from the upper reference point where measurements have reduced accuracy.
(2) The distance from the lower reference point where measurements have reduced accuracy.
(3) The measuring range for the PTFE covered Flexible Single Lead probe includes the weight when measuring on a high dielectric
media.
(4) Note that the weight length or chuck fastening length adds to non-measurable area and is not included in the diagram.
(5) When using a metallic centering disc, the lower transition zone is 8 in. (20 cm), including weight if applicable. When using a PTFE
centering disc, the lower transition zone is not affected.

Note
The 4–20 mA set points are recommended to be configured between the transition zones, within the measuring range.

www.Emerson.com 21
Rosemount 3300 Level Transmitter September 2024

Functional specifications

General
Field of application
Liquids and semi-liquids level or liquid/liquid interfaces
■ Model 3301, for level or submerged probe interface measurement
■ Model 3302, for level and interface measurements

Measurement principle
Time Domain Reflectometry (TDR)
Microwave output power
Nominal 50 μW, Max. 2 mW
EMC
FCC part 15 subpart B and EMC Directive (2014/30/EU). Considered to be an unintentional radiator under the Part 15
rules.
Humidity
0 to 100% relative humidity
Start-up time
< 10 s

4-20 mA HART®
Output
Two-wire, 4-20 mA. Digital process variable is superimposed on 4-20 mA signal, and available to any host that conforms
to the HART® protocol. The digital HART signal can be used in multidrop mode.
® ™
Rosemount 333 HART Tri-Loop
By sending the digital HART signal to the optional HART Tri-Loop, it is possible to have up to three additional 4–20 mA
analog signals.

Related information
Rosemount 333 Product Data Sheet

Emerson Wireless 775 THUM Adapter
The optional Emerson Wireless 775 THUM Adapter can be mounted directly on the transmitter or by using a remote
mounting kit.

IEC 62591 (WirelessHART®) enables access to multivariable data and diagnostics, and adds wireless to almost any
measurement point.

22 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Related information
Emerson Wireless 775 THUM Adapter Product Data Sheet

Power requirements
Terminals in the transmitter housing provide connections for signal cables. The Rosemount 3300 Level Transmitter is
loop-powered and operates with the following power supplies:
Table 6: External Power Supply for HART

Approval type Input voltage (Ui)(1)

None 11 - 42 Vdc

Intrinsically Safe 11 - 30 Vdc

Explosion-proof/Flameproof 16 - 42 Vdc

(1) Reverse polarity protection.

Figure 4: External Power Supply for HART

R
UE
UI

R = Load Resistance (Ω)


UE = External Power Supply Voltage (Vdc)
Ui = Input Voltage (Vdc)

For Flameproof/Explosion-proof installations the Rosemount 3300 Series transmitters have a built-in barrier; no
external barrier needed.
When the Emerson Wireless 775 THUM™ Adapter is fitted, it adds a maximum drop of 2.5 Vdc in the connected loop.
Signal on alarm

High Low

Standard 21.75 mA 3.75 mA

Namur NE43 22.50 mA 3.60 mA

Saturation levels

High Low

Standard 20.8 mA 3.9 mA

Namur NE43 20.5 mA 3.8 mA

www.Emerson.com 23
Rosemount 3300 Level Transmitter September 2024

Load limitations
For HART® communication, a minimum loop resistance of 250 Ω is required. Maximum loop resistance is determined
by the voltage level of the external power supply, as given by the following diagrams:
Figure 5: Non-Hazardous Installations

A C

A. Loop Resistance (Ohms)


B. External Power Supply Voltage (Vdc)
C. Operating region

Figure 6: Intrinsically Safe Installations

A. Loop Resistance (Ohms)


B. External Power Supply Voltage (Vdc)
C. Operating region

Figure 7: Explosion-proof/Flameproof Installations

A
C

A. Loop Resistance (Ohms)


B. External Power Supply Voltage (Vdc)
C. Operating region

Note
For the Explosion-proof/Flameproof installations the diagram is only valid if the HART load resistance is at the + side,
otherwise the load resistance value is limited to 300 Ω.

24 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Modbus®
Output
The RS-485 Modbus version communicates by Modbus RTU, Modbus ASCII, and Levelmaster protocols.
8 data bits, 1 start bit, 1 stop bit, and software selectable parity.

Baud Rate 1200, 2400, 4800, 9600 (default), and 19200 bits/s
Address Range 1 to 255 (default device address is 246)

HART communication is used for configuration via the HART terminals or tunneling via the RS-485.
External power supply
The input voltage Ui for Modbus is 8-30 Vdc (max. rating).
Figure 8: External Power Supply for Modbus
RS485 bus

UI

Ui = Input Voltage (Vdc)

For Flameproof/Explosion-proof installations the Rosemount 3300 Series transmitters have a built-in barrier; no
external barrier needed.
Power consumption
■ < 0.5 W (with HART address=1)
■ < 1.2 W (incl. four HART slaves)

Display and configuration


Integral display
The integral digital display can toggle between: level, distance, volume, internal temperature, interface distance,
interface level, peak amplitudes, interface thickness, percentage of range, analog current out.
Note
The display cannot be used for configuration purposes.

Remote display
Data can be read remotely by using the Rosemount 751 Field Signal Indicator, see the corresponding Product Data
Sheet for more information.

www.Emerson.com 25
Rosemount 3300 Level Transmitter September 2024

Configuration tools
■ Rosemount Radar Configuration Tool (included in the delivery)
■ Device Descriptor (DD) compliant systems
■ Device Type Manager (DTM™) compliant systems

Output units
■ Level, Interface and Distance: ft., in., m, cm, or mm
■ Volume: ft.3, in.3, US gals, Imp gals, barrels, yd3, m3, or liters

Output variables
Table 7: Output Variables

Variable 3301 3302

Level ✓ ✓

Distance (to product surface) ✓ ✓

Volume ✓ ✓

Internal Temperature ✓ ✓

Interface Level (✓)(1) ✓

Interface Distance (✓)(1) ✓

Upper Product Thickness N/A ✓

Peak Amplitudes ✓ ✓

(1) Interface measurement only for fully submerged probe.

Damping
0-60 s (10 s, default value)

26 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Process temperature and pressure rating


Figure 9 gives the maximum process temperature (measured at the lower part of the flange or threaded connection)
and pressure rating.

Final rating depends on flange, material of construction, and O-ring selection.


Figure 9: Maximum Rating, Standard Tank Connections

580 (40)

232 (16)

C
-15 (-1)
B
-40 302
(-40) (150)

A. Pressure psig (bar)


B. Temperature °F (°C)
C. Protective plate: PTFE (Material of construction code 7)

Table 8: Temperature and Pressure Ranges for Standard Tank Seals with Different O-ring Material

O-ring material Temperature °F (°C) in air Pressure psig (bar)

Minimum Maximum Maximum

Fluoroelastomer (FKM) -22 (-30) 302 (150) 580 (40)

Ethylene Propylene (EPDM) -40 (-40) 266 (130) 580 (40)

Kalrez Perfluoroelastomer (FFKM)


®
14 (-10) 302 (150) 580 (40)

Nitrile Butadiene (NBR) -31 (-35) 230 (110) 580 (40)

Note
Always check the chemical compatibility of the O-ring material with your application. If the O-ring material is not
compatible with its chemical environment, the O-ring may eventually malfunction.

www.Emerson.com 27
Rosemount 3300 Level Transmitter September 2024

Temperature limits
Ambient temperature
The maximum and minimum ambient temperature for the electronics depends the approval.
Note
In applications where the ambient temperature exceeds the limits of the electronics, a Remote Mounting connection
can be used. The maximum temperature for the Remote Mounting connection at the vessel connection point is 302 °F
(150 °C).

Table 9: Ambient Temperature Limits

Description Operating limit Storage limit

Without integral display -40 °F to 185 °F (-40 °C to 85 °C) -40 °F to 176 °F (-40 °C to 80 °C)

With integral display -40 °F to 158 °F (-40 °C to 70 °C)(1) -40 °F to 176 °F (-40 °C to 80 °C)

(1) Integral display may not be readable and device display updates will be slower at temperatures below -4 °F (-20 °C).

Related information
Product certifications

Flange rating
ASME flange rating
316 according to ASME B16.5 Table 2-2.2:
■ Maximum 302 °F/580 psig (150 °C/40 bar)

Alloy C-276 (UNS N10276) according to ASME B16.5 Table 2-3.8:


■ Maximum 302 °F/580 psig (150 °C/40 Bar)

EN flange rating
EN 1.4404 according to EN 1092-1 material group 13E0:
■ Maximum 302 °F/580 psig (150 °C/40 Bar)

Alloy C-276 (UNS N10276) according to EN 1092-1 material group 12E0:


■ Maximum 302 °F/580 psig (150 °C/40 Bar)

JIS flange rating


316 according to JIS B2220 material group 2.2:
■ Maximum 302 °F/580 psig (150 °C/40 Bar)

Fisher and Masoneilan flange rating


316 according to ASME B16.5 Table 2-2.2:
■ Maximum 302 °F/580 psig (150 °C/40 Bar)

28 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Tri Clamp rating


Table 10: Tri Clamp Rating

Size Maximum pressure(1)

1½-in. (37.5 mm) 232 psig (16 bar)

2-in. (50 mm) 232 psig (16 bar)

3-in. (75 mm) 145 psig (10 bar)

4-in. (100 mm) 145 psig (10 bar)

(1) The final rating depends on the clamp and gasket.

Plate design
Certain models of flanged alloy and PTFE covered probes have a tank connection design with a protective flange
plate that prevents the backing flange from being exposed to the tank atmosphere. The protective flange plate is
manufactured in the same material as the probe. The backing flange is made of 316L/EN 1.4404 for alloy probes, and
316/1.4404 for PTFE covered probes.
Figure 10: Protective Plate
$ %

&

A. Alloy probe and protective plate


B. PTFE covered probe and protective plate
C. Protective plate

PTFE protective plate


Flange rating according to SST backing flange ASME B16.5 Table 2-2.2, EN 1092-1 material group 13E0, and JIS B2220
material group 2.3.
■ Maximum 302 °F/232 psig (150 °C/16 Bar)

Alloy C-276 protective plate


Flange rating according to SST backing flange ASME B16.5 Table 2-2.3, EN 1092-1 material group 13E0, and JIS B2220
material group 2.3.
■ Maximum 302 °F/580 psig (150 °C/40 Bar)

Alloy 400 protective plate


Flange rating according to SST backing flange ASME B16.5 Table 2-2.3, EN 1092-1 material group 13E0, and JIS B2220
material group 2.3.
■ Maximum 302 °F/580 psig (150 °C/40 Bar)

www.Emerson.com 29
Rosemount 3300 Level Transmitter September 2024

Conditions used for flange strength calculations


Table 11: 316/316L Flanges

Standard Bolting material Gasket Flange material Hub material

ASME Stainless steel SA193 Soft (1a) with min. Stainless steel A182 Gr. Stainless steel SA479M
B8M Cl.2 thickness 1.6 mm F316 316

EN, JIS EN 1515-1/-2 group Soft (EN 1514-1) with Stainless steel A182 Stainless steel SA479M
13E0, A4-70 min. thickness 1.6 mm Gr. F316 and EN 316, and EN
10222-5-1.4404 10272-1.4404

Table 12: Process Connection with Plate Design

Standard Bolting material Gasket Flange material Hub material

ASME Stainless steel SA193 Soft (1a) with min. Stainless steel A182 Gr. SB574 Gr. N10276 or
B8M Cl.2 thickness 1.6 mm F316L/F316 SB164 Gr. N04400

EN, JIS EN 1515-1/-2 group Soft (EN 1514-1) with Stainless steel A182
13E0, A4-70 min. thickness 1.6 mm Gr. F316L/F316 and EN
10222-5-1.4404

Table 13: Alloy C-276 Flanges

Standard Bolting material Gasket Flange material Hub material

ASME UNS N10276 Soft (1a) with min. SB462 Gr. N10276 SB574 Gr. N10276
thickness 1.6 mm (solution annealed
condition) or SB575
EN, JIS Soft (EN 1514-1) with Gr. N10276 (solution
min. thickness 1.6 mm annealed condition)

Interface measurements
The Rosemount 3302 is a good choice for measuring the interface of oil and water, or other liquids with significant
dielectric differences. It is also possible to measure interfaces with a Rosemount 3301 in applications where the probe
is fully submerged in the liquid.
Figure 11: Interface Level Measurement
A B

A. Rosemount 3302
B. Rosemount 3301 (fully submerged)
C. Product level
D. Interface level

Interface measurement considerations


If interface is to be measured, follow these criteria:

30 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

■ The dielectric constant of the upper product should be known and should not vary. The Radar Configuration Tools
software has a built-in dielectric constant calculator to assist the user in determining the dielectric constant of the
upper product.
■ The dielectric constant of the upper product must have a lower dielectric constant than the lower product to have a
distinct reflection.
■ The difference between the dielectric constants for the two products must be larger than 10.
■ Maximum dielectric constant for the upper product is 10 for the coaxial probe.
■ The upper product thickness must be larger than 4 in. (0.1 m) for the coaxial probe in order to distinguish the
echoes of the two liquids.
Emulsion layers
Sometimes there is an emulsion layer (mix of the products) between the two products which can affect interface
measurements. For guidelines on emulsion situations, consult your local Emerson representative.

Physical specifications

Material selection
Emerson provides a variety of Rosemount products with various product options and configurations, including
materials of construction that can be expected to perform well in a wide range of applications.
The product information presented is intended as a guide for the purchaser to make an appropriate selection
for the application. It is the purchaser’s sole responsibility to make a careful analysis of all process parameters
(such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying
product, materials, options, and components for the particular application. Emerson is not in a position to evaluate or
guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration,
or materials of construction selected.

Engineered solutions
When standard model codes are not sufficient to fulfill requirements, please consult the factory to explore possible
Engineered Solutions. This is typically, but not exclusively, related to the choice of wetted materials or the design of a
process connection. These Engineered Solutions are part of the expanded offerings and may be subject to additional
delivery lead time. For ordering, factory will supply a special R-labeled numeric option code that should be added at the
end of the standard model string.

Housing and enclosure


Type
Dual compartment (removable without opening the tank). Electronics and cabling are separated. Two entries for
conduit or cable connections. The transmitter housing can be rotated in any direction.

Electrical connection
½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit/cable adapter or PG 13.5 conduit/cable adapter.
Recommended output cabling is twisted shielded pairs, 18-12 AWG.

Housing material
Polyurethane-covered Aluminum or SST Grade CF8M (ASTM A743)

Ingress protection
NEMA® 4X, IP 66, IP 67

www.Emerson.com 31
Rosemount 3300 Level Transmitter September 2024

Factory sealed
Yes

Weight
■ Aluminum transmitter head: 5.5 lb (2.5 kg)
■ SST transmitter head: 11 lb (5 kg)

Remote housing mounting


Kit that includes a flexible armored extension cable and a bracket for wall or pipe mounting.
Figure 12: Remote Housing Mounting

A. Remote Housing Mounting Cable: 3, 6, or 9 ft (1, 2, or 3 m)

Tank connection
The tank connection consists of a tank seal, a flange, Tri Clamp, or NPT or BSPP (G) threads.

Flange dimensions
Follows ASME B16.5, JIS B2220, and EN 1092-1 standards for blind flanges.

Related information
Standard flanges
Proprietary flanges

Vented flanges
Available with Masoneilan and Fisher vented flanges. Vented flanges must be ordered as accessories with a 1½-in. NPT
threaded process connection (code RA). As an alternative to a vented flange, it is possible to use a flushing connection
ring on top of the standard nozzle.

Tri Clamp connection


Follows ISO 2852 standard.

Pressure Equipment Directive (PED)


Complies with 2014/68/EU article 4.3

32 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Probes
Probe versions
Coaxial, rigid single lead, and flexible single lead.
For interface measurements, rigid single probe is the best choice for chamber mounting. The coaxial probe is the
preferred choice for clean, low dielectric constant liquids.
For guidelines on which probe to select depending on application, see the Rosemount 3300 Reference Manual.
Total probe length
This is defined from the Upper Reference Point to the end of the probe (weight included, if applicable).
Figure 13: Total Probe Length
$ % & '

A. NPT
B. BSPP (G)
C. Flange
D. Tri Clamp
E. Upper reference point
F. Total probe length

Select the probe length according to the required measuring range (the probe must be hung and fully extended
through the entire distance where level readings are desired).
Cut-to-fit probes
All probes can be cut in field except for the PTFE covered probe.
However, there are some restrictions for the coaxial probe: Probes over 4.1 ft. (1.25 m) can be cut up to 2 ft. (0.6 m).
Shorter probes can be cut to the minimum length of 1.3 ft. (0.4 m).
Minimum and maximum probe length

Probe type Probe length

Flexible single lead 3.3 to 77.1 ft. (1 to 23.5 m)

Rigid single lead (0.3 in./8 mm) 1.3 to 9.8 ft. (0.4 to 3 m)

Rigid single lead (0.5 in./13 mm) 1.3 to 19.7 ft. (0.4 to 6 m)

Segmented rigid single lead 1.3 to 19.7 ft. (0.4 to 6 m)

Coaxial 1.3 to 19.7 ft. (0.4 to 6 m)

www.Emerson.com 33
Rosemount 3300 Level Transmitter September 2024

Probe angle
0 to 90 degrees from vertical axis
Tensile strength
■ 0.16 in. (4 mm) Flexible single lead SST: 2698 lb (12 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy C-276: 1574 lb (7 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy 400: 1124 lb (5 kN)

Collapse load
■ 0.16 in. (4 mm) Flexible single lead SST: 3597 lb (16 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy C-276: 1798 lb (8 kN)
■ 0.16 in. (4 mm) Flexible single lead Alloy 400: 1349 lb (6 kN)

Sideway capacity
■ Rigid single lead/Segmented rigid single lead: 4.4 ft. lbf, 0.44 lb at 9.8 ft. (6 Nm, 0.2 kg at 3 m)
■ Coaxial: 73.7 ft. lbf, 3.7 lb at 19.7 ft. (100 Nm, 1.67 kg at 6 m)

Material exposed to tank atmosphere


Table 14: Standard Probe (Operating Temperature and Pressure Code S)

Material of construction code Material exposed to tank atmosphere

1 316L/316 (EN 1.4404), PTFE, PFA, silicone grease, and O-ring materials

2 Alloy C-276 (UNS N10276), PTFE, PFA, silicone grease, and O-ring materials

3 Alloy 400 (UNS N04400), Alloy K500 (UNS N05500), PTFE, PFA, silicone grease, and
O-ring materials

7 PTFE (1 mm PTFE cover)

8 316L/316 (EN 1.4404), PTFE, silicone grease, and O-ring materials

Weight
Table 15: Flange and Probes

Item Weight

Flange Depends on flange size

Flexible single lead probe 0.05 lb/ft. (0.08 kg/m)

Rigid single lead probe (0.3-in./8 mm) 0.27 lb/ft. (0.4 kg/m)

Rigid single lead probe (0.5-in./13 mm) 0.71 lb/ft. (1.06 kg/m)

Segmented rigid single lead probe 0.71 lb/ft. (1.06 kg/m)

Coaxial probe 0.67 lb/ft. (1 kg/m)

Table 16: End Weight

Item Weight

Standard weight for flexible single lead probe (0.16-in./4 mm) 0.88 lb (0.40 kg)

Short weight (W2) for flexible single lead probe (0.16-in./4 mm) 0.88 lb (0.40 kg)

Heavy weight (W3) for flexible single lead probe (0.16-in./4 mm) 2.43 lb (1.10 kg)

Weight for PTFE covered flexible single lead 2.2 lb (1 kg)

34 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

End weight options


A short weight is available for the single flexible probe. It is used for measuring close to the probe end and shall be
used where the measuring range must be maximized. The height is 2 in. (50 mm) and the diameter is 1.5 in. (37.5 mm).
The option code is W2.
If a heavier weight is needed, option code W3 can be used. The height is 5.5 in. (140 mm) and the diameter is 1.5 in.
(37.5 mm).

Installation and mounting considerations


Free space requirement
If the probe is mounted close to a wall, nozzle or other tank obstruction, noise might appear in the level signal.
Therefore the following minimum clearance, according to Table 17, must be maintained.
Figure 14: Free Space Requirement

L. Clearance to tank wall

Table 17: Recommended Minimum Free Space for Optimal Performance

Probe type Condition Minimum clearance (L)

Rigid single lead/Segmented rigid single lead(1) Smooth metal tank wall 4 in. (100 mm)

Disturbing objects such as pipes and beams 12 in. (300 mm)


Plastic, concrete or rugged metal tank wall

Flexible single Smooth metal tank wall 4 in. (100 mm)

Disturbing objects such as pipes and beams 12 in. (300 mm)


Plastic, concrete or rugged metal tank wall

Coaxial(1) N/A 0 in. (0 mm)

(1) Minimum clearance from tank bottom for the coaxial and rigid single probes is 0.2 in. (5 mm).

www.Emerson.com 35
Rosemount 3300 Level Transmitter September 2024

Flange connection on nozzles


Figure 15: Mounting in Nozzles
$

'

A. Confirm the nozzle does not extend into the tank.

The transmitter can be mounted in nozzles by using an appropriate flange. It is recommended that the nozzle size is
within the dimensions given in Table 18.
Table 18: Nozzle Considerations for Optimal Performance

Single (rigid/segmented/flexible) Coaxial

Recommended nozzle diameter (D) 6 in. (150 mm) > probe diameter

Minimum nozzle diameter (D)(1) 2 in. (50 mm) > probe diameter

Recommended nozzle height (H)(2) 4 in. (100 mm) + nozzle diameter(3) N/A

(1) The Trim Near Zone (TNZ) function may be necessary or an Hold Off Distance/Upper Null Zone (UNZ) setup may be required to mask
the nozzle.
(2) Longer nozzles may be used in certain applications. Consult your local Emerson representative for details.
(3) For nozzles taller than 4 in. (100 mm), the long stud version is recommended (option code LS) to prevent the flexible portion from
touching the edge of the nozzle.

Note
The probe must not be in contact with the nozzle (except for the coaxial probe).

Installation in still pipe/chamber

General chamber considerations


Dimensioning the chamber/pipe correctly and selecting the appropriate probe is key to the success in these
applications. When selecting a smaller chamber/pipe diameter, such as 2-in., a flexible probe is not suitable due to
the chance of it coming into contact with the walls. Also, relatively large side inlets may interfere with the signal.
When gas lift and/or turbulence may occur (e.g. boiling hydrocarbons), a 3- or 4-in. chamber/pipe diameter is
recommended for maximum measurement reliability. This is especially true in high pressure and high temperature
installations.

36 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Table 19: Recommended and Minimum Chamber/Still Pipe Diameters for Different Probes

Probe type Recommended diameter Minimum diameter

Rigid single/segmented rigid single 3 or 4 in. (75 or 100 mm) 2 in. (50 mm)

Flexible single 4 in. (100 mm) Consult your local Emerson representative

Coaxial 3 or 4 in. (75 or 100 mm) 1.5 in. (37.5 mm)

Note
Metal pipes are preferred, especially in applications with low dielectric constant, to avoid disturbances from objects
near the pipe.

Rosemount chamber
A Rosemount chamber allows external mounting of process level instrumentation. It supports a variety of process
connections, and optional drain and vent connections. The standard Rosemount chambers are designed according
to ASME B31.3. Rosemount chambers compliant with the Pressure Equipment Directive (PED) are available. Customer
specific engineered solutions for Rosemount chambers are available upon request. Use option code XC to order
together with the Rosemount 3300 Series Transmitters.
Use a centering disc the same diameter as the chamber if the probe length >3.3 ft. (1 m). See Table 22 for which disc to
use.

Existing chamber
A Rosemount 3300 Level Transmitter is the perfect replacement in an existing displacer chamber. Proprietary flanges
are offered, enabling use of existing chambers to make installation easy.
Figure 16: Existing Displacer Chamber

% &

A. Replace chamber flange


B. Probe length
C. Displacer length

Considerations when changing to Rosemount 3300:


■ The Rosemount 3300 Level Transmitter flange choice and probe length must be correctly matched to the chamber.
Both standard ASME and EN (DIN), as well as proprietary chamber flanges, are available. See Proprietary flanges to
identify the proprietary flanges.
■ See Table 22 for guidelines on which disc size to use.
■ See Table 20 for guidelines on the required probe length.

www.Emerson.com 37
Rosemount 3300 Level Transmitter September 2024

Table 20: Required Probe Length in Chambers

Chamber manufacturer Probe length(1)

Major torque-tube manufacture (249B, 249C, 249K, 249N, 259B) Displacer + 9 in. (229 mm)

Masoneilan (torque tube operated), proprietary flange



Displacer + 8 in. (203 mm)

Other - torque tube(2) Displacer + 8 in. (203 mm)

Magnetrol (spring operated)(3)


®
Displacer + between 7.8 in. (195 mm) to 15 in. (383 mm)

Others - spring operated(2) Displacer + 19.7 in. (500 mm)

(1) If flushing ring is used, add the ring height to the probe length.
(2) For other manufacturers, there are small variations. This is an approximate value; actual length should be verified.
(3) Lengths vary depending on model, SG, and rating, and should be verified.

For additional information, see the Replacing Displacers with Guided Wave Radar Technical Note.

Probe type in chamber considerations


When installing a Rosemount 3300 in a chamber, the single lead probe is recommended.
The probe must not touch the chamber wall, should extend the full height of the chamber, but not touch the bottom of
the chamber.
The probe length determines if a single rigid or single flexible probe should be used:
■ Less than 19.7 ft. (6.0 m): Rigid single probe is recommended. Use a centering disc for probe > 3.3 ft. (1 m). When
mounting space is limited, use a flexible single probe with a weight and centering disc.
■ More than 19.7 ft. (6.0 m): Use flexible single probe with a weight and centering disc.

Centering disc for pipe installations


To prevent the probe from contacting the chamber or pipe wall, centering discs are available for flexible single and
rigid single probes. The disc is attached to the end of the probe. Discs are made of stainless steel, Alloy C-276, Alloy
400, or PTFE.
For the segmented rigid single lead probe, up to five PTFE centering discs can be mounted along the probe, but
keep a minimum distance of two segments between the discs. Additionally, a disc in SST or PTFE (part number
03300-1655-xxxx) can be attached to the end of the probe.
When mounting a centering disc, it is important that it fits correctly in the chamber/pipe. See Figure 17 for Dimension
D. Table 22 shows which centering disc diameter to choose for a particular pipe.
Figure 17: Dimension D for Centering Discs

'

38 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Table 21: Centering Disc Dimensions

Disc size Actual disc diameter (D)

2-in. 1.8 in. (45 mm)

3-in. 2.7 in. (68 mm)

4-in. 3.6 in. (92 mm)

6-in. 5.55 in. (141 mm)

8-in. 7.40 in. (188 mm)

Table 22: Centering Disc Size Recommendation for Different Pipe Schedules

Pipe size Pipe schedule

5s, 5 and 10s,10 40s, 40 and 80s, 80 120 160

2-in. 2-in. 2-in. N/A(1) N/A(2)

3-in. 3-in. 3-in. N/A(1) 2-in.

4-in. 4-in. 4-in. 3-in. 3-in.

5-in. 4-in. 4-in. 4-in. 4-in.

6-in. 6-in. 6-in. 4-in. 4-in.

7-in. N/A(1) 6-in. N/A(1) N/A(1)

8-in. 8-in. 8-in. 6-in. 6-in.

(1) Schedule is not available for pipe size.


(2) No centering disc is available.

Installation in non-metallic tanks and open-air applications


Avoid major sources of electrical disturbance in proximity of the installation (e.g. electrical motors, stirrers, servo
mechanisms).
Figure 18: Avoid Electromagnetic Disturbances

www.Emerson.com 39
Rosemount 3300 Level Transmitter September 2024

For clean liquids, use a coaxial probe to reduce effect of potential electrical disturbances.
Figure 19: Coaxial Probe in an Open-Air Application

For optimal single lead probe performance in non-metallic tanks, the probe must be mounted with a metal flange, or
screwed in to a metal sheet (d > 14 in./350 mm) if a threaded version is used.
Figure 20: Mounting in Non-Metallic Tanks

$ %

A. Metal flange
B. Metal sheet (d > 14 in./350 mm)

Minimum distance between two single probes


When installing multiple Rosemount 3300 Level Transmitters with single probes in the same tank, ensure to place the
devices at proper distance from each other to avoid the risk of interference caused by cross-talk. Table 23 provides
recommended minimum distance between two probes. A coaxial probe or a probe installed in a still pipe will not cause
any cross-talk.
Table 23: Minimum Distance between Single Probes

Product Minimum distance between probes

Oil (DC = 2.1) 5.2 ft. (1.6 m)

Water (DC = 80) 3.3 ft. (1.0 m)

Other mechanical considerations


To get best possible performance, the following must be considered before installing the transmitter:
■ Inlets should be kept at a distance in order to avoid product filling on the probe
■ Avoid physical contact between probes and agitators, as well as applications with strong fluid movement unless the
probe is anchored

40 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

■ Probe tie-down is recommended if the probe can move to within 1 ft. (30 cm) of any object during operations
■ In order to stabilize the probe for side forces, it is possible to fix or guide the probe to the tank bottom

Figure 21: Stabilize the Probe for Side Forces

A. Flexible single lead probe with chuck.

See the Rosemount 3300 Reference Manual for more mechanical installation information.

Product certifications
See the Rosemount 3300 Product Certifications document for detailed information on the existing approvals and
certifications.

www.Emerson.com 41
Rosemount 3300 Level Transmitter September 2024

Dimensional drawings
Figure 22: Rigid Single Lead Probe with Flange Connection
6.8 (173)

4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241)

A. L ≤ 10 ft. (3 m); L ≤ 20 ft. (6 m) for Ø 0.51 (13)


B. Ø 0.31 (8) or Ø 0.51 (13) for SST and Alloy probes; Ø 0.47 (12) for PTFE covered probe
C. The PTFE and alloy probes are designed with a protective plate.
Dimensions are in inches (millimeters).

42 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 23: Rigid Single Lead Probe with Threaded Connection


A B B

6.8 (173) 6.8 (173)

C 4.3 (110) 4.1 (104)


4.3 (110)

4.5 (113)

9.5 (241) 9.5 (241)


D
G
2.4 (62)
1.1 (27)

E E

F F

A. G 1/1½ inch
B. NPT 1/1½/2 inch
C. ½ - 14 NPT; optional adapters: M20x1.5
D. s52/s60
E. L ≤ 10 ft. (3 m); L ≤ 20 ft. (6 m) for Ø 0.51 (13)
F. Ø 0.31 (8) or Ø 0.51 (13) for SST and Alloy probes; Ø 0.47 (12) for PTFE covered probe
G. s52
Dimensions are in inches (millimeters).

www.Emerson.com 43
Rosemount 3300 Level Transmitter September 2024

Figure 24: Segmented Rigid Single Lead Probe with Flange Connection
6.8 (173)

A 4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241)

0.6 (15)

15.2 (385)

31.5 (800)

Ø 0.51 (13) D

A. ½ - 14 NPT; optional adapters: M20x1.5


B. L ≤ 20 ft. (6 m)
C. Optional: PTFE centering disc
D. Optional: Bottom centering disc (SST or PTFE)
Dimensions are in inches (millimeters).

44 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 25: Segmented Rigid Single Lead Probe with Threaded Connection
6.8 (173)

A 4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241)
C F

0.6 (15) 2.4 (62)


2.4 (62)

1.1 (27)
15.2 (385)

31.5 (800)

Ø 0.51 (13)
E

A. ½ - 14 NPT; optional adapters: M20x1.5, PG 13.5


B. L ≤ 20 ft. (6 m)
C. BSP-G 1 in., s52; BSP-G 1½ in., s60
D. Optional: PTFE centering disc
E. Optional: Bottom centering disc (SST or PTFE)
F. NPT 1 in., s52; NPT 1½ in., s52; NPT 2 in., s60
Dimensions are in inches (millimeters).

www.Emerson.com 45
Rosemount 3300 Level Transmitter September 2024

Figure 26: Flexible Single Lead Probe with Flange Connection


6.8 (173)

4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241)

B
A
G

F
C
5.5 (140)
2 (50)
D
Ø 1.5 (37.5) Ø 1.5 (37.5)

A. L ≤ 77 ft. (23.5 m)
B. Ø 0.16 (4) for SST probe; Ø 0.28 (7) for PTFE covered probe
C. 5.5 (140) for SST probe; 17.1 (435) for PTFE covered probe
D. Ø 0.86 (22) for SST probe; Ø 0.88 (22.5) for PTFE covered probe
E. The PTFE covered probe is designed with a protective plate.
F. Short weight (option W2)
G. Heavy weight (option W3)
Dimensions are in inches (millimeters).

46 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 27: Flexible Single Lead Probe with Threaded Connection


A B B

6.8 (173) 6.8 (173)

C 4.3 (110) 4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241) 9.5 (241)


E I

2.4 (62)
1.1 (27)

F F
D D K

J
G 5.5 (140)
2 (50)

H Ø 1.5 (37.5) Ø 1.5 (37.5)

A. G 1/1½ in.
B. NPT 1/1½/2 in.
C. ½ - 14 NPT; optional adapters: M20x1.5
D. L ≤ 77 ft. (23.5 m)
E. s52/s60
F. Ø 0.16 (4) for SST probe; Ø 0.28 (7) for PTFE covered probe
G. 5.5 (140) for SST probe; 17.1 (435) for PTFE covered probe
H. Ø 0.86 (22) for SST probe; Ø 0.88 (22.5) for PTFE covered probe
I. 1 in./1½ in.: s52; 2 in.: s60
J. Short weight (option W2)
K. Heavy weight (option W3)
Dimensions are in inches (millimeters).

www.Emerson.com 47
Rosemount 3300 Level Transmitter September 2024

Figure 28: Coaxial Probe with Flange Connection


6.8 (173)

4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241)

B B C

1.1 (28)

A. L ≤ 20 ft. (6 m)
B. For stainless steel the probe is welded to the flange.
C. The alloy probes are designed with a protective plate.
Dimensions are in inches (millimeters).

48 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 29: Coaxial Probe with Threaded Connection


A B B

6.8 (173) 6.8 (173)


C 4.3 (110) 4.3 (110) 4.1 (104)

4.5 (113)

9.5 (241) F
9.5 (241)
E

2.4 (62)
1.1 (27)

D D

1.1 (28) 1.1 (28)

A. G 1/1½ in.
B. NPT 1/1½/2 in.
C. ½ - 14 NPT; optional adapters: M20x1.5
D. L ≤ 20 ft. (6 m)
E. s52/s60
F. 1 in./1½ in.: s52; 2 in.: s60
Dimensions are in inches (millimeters).

www.Emerson.com 49
Rosemount 3300 Level Transmitter September 2024

Figure 30: Bracket Mounting


A B

E
5. 2 (133)

C D

0.87 (22)

0.35 (9)

2.76
(70)

2.24
(57)

A. Pipe mounting (vertical pipe)


B. Pipe mounting (horizontal pipe)
C. Wall mounting
D. Hole pattern for wall mounting
E. Pipe diameter: maximum 2.5 in. (64 mm)
Dimensions are in inches (millimeters).

50 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Figure 31: Remote Housing

5.2 (133)

B
C

A. 3, 6, 9 ft. (1, 2, or 3 m)
B. Rmin: 1.4 (35)
C. Hmin: 7.3 (185)
Dimensions are in inches (millimeters).

Standard flanges
Figure 32: Flange Connection
A B C

D F

A. Forged one-piece
B. Welded construction
C. Protective plate design
D. Weld
E. Backing flange
F. Protective plate

www.Emerson.com 51
Rosemount 3300 Level Transmitter September 2024

Table 24: Standard Flanges

Standard Face type(1) Plate surface finish, Ra

ASME B16.5 Raised face 125-250 µin

EN 1092-1 Type A flat face 3.2-12.5 µm

JIS B2220 Raised face 3.2-6.3 µm

(1) Face gasket surface is serrated per mating standard.

Table 25: Standard Flanges, Protective Plate

Standard Face type including protective plate Plate surface finish, Ra

ASME B16.5 Raised face 3.2-6.3 µm

EN 1092-1 Raised face 3.2-6.3 µm

JIS B2220 Raised face 3.2-6.3 µm

Proprietary flanges
Figure 33: Proprietary Flanges
% %

* . ' * . '

% %

D: Outside diameter
B1: Flange thickness with gasket surface
B2: Flange thickness without gasket surface
F=B1-B2: Gasket surface thickness
G: Gasket surface diameter
# Bolts: Number of bolts
K: Bolt hole circle diameter

Dimensions are in inches (millimeters).

Note
Dimensions may be used to aid in the identification of installed flanges. It is not intended for manufacturing use.

52 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

Table 26: Dimensions of Proprietary Flanges

Special flanges(1) D B1 B2 F G # Bolts K

Fisher 249B/259B(2)

9.00 (228.6) 1.50 (38.2) 1.25 (31.8) 0.25 (6.4) 5.23 (132.8) 8 7.25 (184.2)

Fisher 249C(3) 5.69 (144.5) 0.94 (23.8) 1.13 (28.6) -0.19 (-4.8) 3.37 (85.7) 8 4.75 (120.65)

Masoneilan ™(2)
7.51(191.0) 1.54 (39.0) 1.30 (33.0) 0.24 (6.0) 4.02 (102.0) 8 5.87 (149.0)

(1) These flanges are also available in a vented version.


(2) Flange with raised face.
(3) Flange with recessed face.
For information about flange temperature and pressure ratings, see Fisher and Masoneilan flange rating.

Flushing connection rings


Figure 34: Flushing Connection Rings
'R

'+ $

'L

A. Height: 0.97 in. (24.6 mm)

Table 27: Dimensions of Flushing Connection Rings

Flushing connection rings Di Do DH

2-in. ANSI 2.12 (53.8) 3.62 (91.9) ¼-in. NPT

3-in. ANSI 3.60 (91.4) 5.00 (127.0) ¼-in. NPT

4-in. ANSI/DN100 3.60 (91.4) 6.20 (157.5) ¼-in. NPT

DN50 2.40 (61.0) 4.00 (102.0) ¼-in. NPT

DN80 3.60 (91.4) 5.43 (138.0) ¼-in. NPT

www.Emerson.com 53
Rosemount 3300 Level Transmitter September 2024

54 www.Emerson.com
September 2024 Rosemount 3300 Level Transmitter

www.Emerson.com 55
00813-0100-4811
Rev. JF
September 2024

For more information: Emerson.com/global


©2024 Emerson. All rights reserved.

Emerson Terms and Conditions of Sale are available


upon request. The Emerson logo is a trademark and
service mark of Emerson Electric Co. Rosemount is a
mark of one of the Emerson family of companies. All
other marks are the property of their respective owners.