DeviceFollowUpReport Jul 24 2025 13-35-19

The LATITUDE™ Programming System report for Sukendu Das indicates that the ACCOLADE MRI device was interrogated on July 23, 2025, with no alerts present. The device's battery is functional with an estimated explant time of over 11 years, and various lead data and settings are documented, showing stable performance. There have been no recorded ventricular or atrial episodes since the last reset, indicating effective device operation.

Uploaded by

hindupokho108
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views4 pages

DeviceFollowUpReport Jul 24 2025 13-35-19

The LATITUDE™ Programming System report for Sukendu Das indicates that the ACCOLADE MRI device was interrogated on July 23, 2025, with no alerts present. The device's battery is functional with an estimated explant time of over 11 years, and various lead data and settings are documented, showing stable performance. There have been no recorded ventricular or atrial episodes since the last reset, indicating effective device operation.

Uploaded by

hindupokho108
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

LATITUDE™ Programming System Report Created 24 Jul 2025

Device Follow-up Report


, SUKHENDU DAS Last Office Interrogation
Date of Birth N/R N/R N/R 23 Jul 2025
Device ACCOLADE MRI EL L331/ 181754 Implant Date
23 Jul 2025

My Alerts
There are no alerts to display.
Events Since Last Reset (23 Jul 2025)
24 Jul 2025 10:13 RV Auto
24 Jul 2025 10:11 RA Auto
Battery OK
Approximate time to explant: > 11 years
Magnet Rate 100 ppm One Year Remaining

Explant
Leads Data Implant Previous Session Most Recent
23 Jul 2025
Atrial
Intrinsic Amplitude N/R mV 12.4 mV 7.2 mV
Pace Impedance N/R Ω 695 Ω 641 Ω
Pace Threshold N/R V @ N/R ms 0.5 V @ 0.4 ms Auto 0.3 V @ 0.4 ms
Ventricular
Intrinsic Amplitude N/R mV >25.0 mV >25.0 mV@70 bpm
Pace Impedance N/R Ω 810 Ω 749 Ω
Pace Threshold N/R V @ N/R ms 0.6 V @ 0.4 ms Auto 0.6 V @ 0.4 ms
POST completed. Test started at 23 Jul 2025 19:16
Settings
Ventricular Tachy Settings Atrial Tachy Settings
Ventricular Tachy EGM Storage On ATR Mode Switch 170 bpm DDI
Detection Rate 160 bpm
Brady Settings
Mode DDDR Pacing Output
RYTHMIQ™ Off Atrial Trend 2.5 V @ 0.4ms
Lower Rate Limit 60 ppm Ventricular Trend 2.5 V @ 0.4ms
Maximum Tracking Rate 130 ppm Sensitivity
Maximum Sensor Rate 130 ppm Atrial Fixed 0.75 mV
Paced AV Delay 80 - 180 ms Ventricular Fixed 2.5 mV
Sensed AV Delay 65 - 150 ms Leads Configuration (Pace/Sense)
A-Refractory (PVARP) 240 - 280 ms Atrial Bipolar
V-Refractory (VRP) 230 - 250 ms Ventricular Bipolar
Rate Adaptive Pacing
Minute Ventilation On
Accelerometer Passive

3869 Software Version: 1.10 © 2014-2019 Clinician Signature:


L331 Firmware Version: F_v1.00.00(2.01) Boston Scientific Corporation
or its affiliates. All rights reserved.
Page 1 of 4
LATITUDE™ Programming System , SUKHENDU DAS
Device Follow-up Report 24 Jul 2025 13:35

Trends
P-Wave Amplitude

A Pace Impedance

A Pace Threshold

R-Wave (V)
Amplitude

V Pace Impedance

V Pace Threshold

3869 Software Version: 1.10 © 2014-2019 Clinician Signature:


L331 Firmware Version: F_v1.00.00(2.01) Boston Scientific Corporation
or its affiliates. All rights reserved.
Page 2 of 4
LATITUDE™ Programming System , SUKHENDU DAS
Device Follow-up Report 24 Jul 2025 13:35

Ventricular Tachy Counters Since Last Reset Device Totals


23 Jul 2025
Ventricular Episode Counters
Total Episodes 0 0
VT Episodes (V>A) 0 0
SVT Episodes (V<=A) 0 0
Nonsustained Episodes 0 0
Brady Counters Reset Before Last Since Last Reset
N/R day(s) 1 day(s)
N/R to 23 Jul 2025 23 Jul 2025 to Today
Counters
% A Paced 0 18
% V Paced 0 3
Intrinsic Promotion
AV Search +
% Successful 0 100
Rate Hysteresis
% Successful 0 0
Atrial Arrhythmia
% AT/AF N/R N/R
Total Time in AT/AF N/R N/R
Episodes by Duration
< 1 minute 0 0
1 min - < 1 hr 0 0
1 hr - < 24 hr 0 0
24 hr - < 48 hr 0 0
> 48 hr 0 0
Total PACs 0 63
Ventricular Counters
Total PVCs 0 77
Three or More PVCs 0 3

3869 Software Version: 1.10 © 2014-2019 Clinician Signature:


L331 Firmware Version: F_v1.00.00(2.01) Boston Scientific Corporation
or its affiliates. All rights reserved.
Page 3 of 4
LATITUDE™ Programming System , SUKHENDU DAS
Device Follow-up Report 24 Jul 2025 13:35

Histograms Reset Before Last (N/R)

Histograms Since Last Reset (23 Jul 2025)

3869 Software Version: 1.10 © 2014-2019 Clinician Signature:


L331 Firmware Version: F_v1.00.00(2.01) Boston Scientific Corporation
or its affiliates. All rights reserved.
Page 4 of 4