EIB Gateway
EIB Gateway
User Manual
Version v0.9
CTB-KNX/IP
CTB-EIB/NX
Contents
1. Introduction ............................................................................................. 2 2. Configuration of the IP Address.............................................................. 4 3. [Get Info] From 2-Way Driver ................................................................. 6 4. Technical Data...................................................................................... 12
VIVATEQ GmbH
Siemensstrasse 14 D-73066 Uhingen Phone Fax +49 (7161) 50447-0 +49 (7161) 50447-151
1. Introduction
This driver allows RTI integrators and programmers to hook up with the KNX/EIB infrastructure without having deeper knowledge about KNX/EIB or certification. For proper driver configuration a list from the ETS Configuration (KNX/EIB Infrastructure) specifying the group addresses and the data format is sufficient. These parameters have to be transferred to the driver for the Integration Designer (ID) to create the GUI (Graphical User Interface) with the respective data. Every gateway can address up to 250 groups, and each group can be configured for every function. For projects with more than 250 groups further entities of gateways and drivers can be used. Theoretically there are no limits, except physical limits (ports and memory of the RTI XP controller), but it is advisable to monitor load/performance to add further RTI XP controllers, if necessary. Driver Configuration: Connection: Enter IP address and port (default 10002) of gateway. In addition enter the physical KNX gateway address (example: 1.1.254 = area line element). This has not to be considered mandatorily in the ETS configuration but must be unique in the KNX/EIB system. Additionally the correct area and the respective line are to be selected. KNX group 0-249: Enter group description, which is transmitted as system variable to ID, KNX/EIB device group address and/or its properties, gateway data format matching the data format of the KNX/EIB properties and the alternative to analyze feedback or not. KNX event 0-9: Enter event description, which is transmitted as system variable to ID, KNX/EIB device group address and/or its properties relating to the event, select the direction of the threshold, and enter the integer value, which triggers the event multiplied by 1000. Note: For Boolean analysis the value 1000 is expected. System Variables: For debugging on integrator level the variable -Last Received Data- can be used. This also shows the result when accessing the function Check Connection-. In case a group address receives a feedback value all associated variables are updated. Functions: There are the possibilities to set the respective group addresses either with the string / integer / Boolean value and furthermore the group address can be recalled with the Get command. This is necessary if the automatic device feedback or its properties are not configured in the KNX/EIB configuration. The integrator himself must program a polling interval.
The IP gateway must be connected to the same network as the configuration PC. At program start a search for all available gateways on the network is performed via network broadcast, and detected devices are displayed in a list. By pressing the button Liste auffrischen the search is started again and the list is updated. Check the network wiring and / or PC configuration (firewall) if no gateways are displayed. Additionally, in some network environments broadcast telegrams to 255.255.255.255 are suppressed. In this case adjust the local broadcast address above the Broadcast Adr. button, e.g. to 172.16.255.255. Gateway list and current password (if active) can be saved as reference with the Export Liste button to a text file.
Select the gateway that has to be changed from the list. Now it is possible to carry out the desired settings (IP address, communication mode, etc.) in the fields below. Confirm with Konfiguration setzen to transmit the details via the network to the selected device. Afterwards the gateway list is automatically refreshed und displays the current device settings. Communication Modes: TCP Server In TCP server mode the gateway waits for incoming TCP connections on the set network port. The TCP connection is only accepted if the IP address of the TCP client matches the setting for permitted IP addresses / masks. The TCP connection is maintained until the client terminates the connection. Afterwards a new TCP connection (even with other clients) can be established.
Password Protection Activate password protection to prevent unknown users from changing the configuration of the gateways with the configuration program. With activated security only unprotected gateways or the correct password can change the gateway. The password is automatically transmitted to the gateway with Konfiguration setzen. To change or deactivate the password of a protected gateway, you first have to activate the password protection with the current password within the program, and then the list has to be refreshed. All protected gateways are marked in the list with a green key icon. Afterwards the password can be changed or deactivated in the setting window, and the new settings are transmitted to the gateway with Konfiguration setzen.
Permitted IP Addresses Fill out the fields Erlaubte IP-Adressen and Maske erlaubter IP-Adressen to permit access to the gateway only for certain IP addresses. If the address 0.0.0.0 is entered in both fields anyone can connect to the gateway. Otherwise only those network participants whose IP addresses and masks match the set values.
Connection
Communication Interface CTG-KNX/IP gateway via IP or CTG-EIB/NX gateway via RS232 IP address (CTG-KNX/IP) IP address of the COMM-TEC gateway (e.g. 192.168.1.1). IP Port (CTG-KNX/IP) IP port of the COMM-TEC gateway ( default: 10002 ). Serial port (CTG-EIB/NX) RS232 port of the XP controller KNX physical address of gateway Unique KNX address of the COMM-TEC gateway (e.g. 1.1.254), must match KNX area and line segment numbers.
KNX group XX
KNX group Description Description of this KNX group. KNX group address The KNX group address to be used by this driver. ( 0-15/0-7/0-255 or 0-15/0-2047 ) KNX group data format The data format of this KNX group. This format depends on the data formats of the COMM-TEC CTG-KNX/IP gateway: - 1-6 bit decimal - 1 byte ASCII - Percent 0-100% - Angle 0-360 degrees - 1 byte unsigned - 1 byte signed - 2 byte unsigned - 2 byte signed - EIB float value - EIB time - EIB date - 4 byte unsigned - 4 byte signed - IEEE float - Entrance access - Textstring - Textstring NUL terminated - 1 to 14 byte decimal, separated with ; - 1 to 14 byte hexadecimal, separated with ; - 1 to 14 byte hexadecimal 2 hex digits per byte - 1 to 6 bit hexadecimal This value should match the corresponding KNX data format.
KNX group enable / disable reception Select enable or disable of data reception for this KNX group.
Event X
Event Description Description of this Event. KNX group address KNX group address to monitor for this event. negative / positive threshold Fire event if KNX group value is negative or positive in relation to threshold value. threshold value Threshold for this event. This value needs to match the KNX Data Value Integer * 1000 value.
Sysvars:
Last Received Data all data received by the gateway (50 byte fifo buffer for debug purposes).
Knx Description Group XX Description for the KNX group (from driver config). Knx Data Value String Group XX Data value as String. Knx Data Value Integer Group XX Data value as Integer (Fix value). Knx Data Value * 1000 Integer Group XX Data value multipied with 1000 as Integer to use as fixed point value (divide it with 1000 to get the fixed point). Knx Data Value Integer 0-100 Group XX Data value as Integer with min=0 and max=100 for percentage display (higher values ar cropped). Knx Data Value Integer 0-360 Group XX Data value as Integer with min=0 and max=360 for degree display (higher values are cropped). Knx Data Value Boolean Group XX Data value as boolean (True False).
Description Event X Description for the Event. KNX group Event X KNX group address to monitor for this Event. negative / positive threshold Event X Fire event if KNX group value is negative or positive in relation to threshold value. Threshold Event X Threshold for this event. This value needs to match the KNX Data Value Integer *1000 value.
10
System Functions:
Connection
CheckConnection sends "?" to the CTG-KNX/IP Gateway > Answer should be the current settings
KNX group XX
Set KNX value Group XX Set the KNX value as string. Set KNX value integer Group XX Set the KNX value as integer. Set KNX value boolean Group XX Set the KNX value as boolean. Get KNX value Group XX Get the current KNX value and convert it to all possible data formats.
11
4.
Technical Data
Power Supply EIB Current Draw EIB/KNX Power Consumption EIB/KNX External AC 230V, 20mA (terminal clamp) DC 24V DC 30V < 12mA Max. 360mW
Button and Display Button LEDs EIB program button Operation, bus voltage, bus telegram, program mode Signaling of TCP/IP connection and activity (CTB-KNX/IP only)
Connections EIB 2 screw terminals (Phoenix MSTB 2.5/2-ST-5.08) Cable diameter: strand: 0.3 0.5mm; solid: 0.8mm 9-pin SubD female (CTB-EIB/NX only) RJ45 jack (CTB-KNX/IP only)
General Ambient Temperature Design Casing Installation 0C 50C, not condensing Casing for top hat rail mounting Plastic, gray On 35mm top hat rail