Isolated Footing
1 Footing Size Design
Load Pu 510 KN
Design Load P 374 KN
Moment in x dir Mux 30 KN-m
Moment in y dir Muy 30 KN-m
Column size cx 300 mm
cy 230 mm
SBC q 160 KN/sqm
Footing Size required A req 2.34 sqmm
L 1.80 meters
Footing Size Provided
B 1.80 meters
Area Provided A prvd 3.24 meters
Zx 0.97
Zx 0.97
Net upward pressure Nup 157 KNm2
Footing Size OK
2 Slab Design
lx 0.750
ly 0.785
Bending Moment in x dir Mx 66 KN-m
Bending Moment in y dir My 72 KN-m
Concrete fck 20 MPa
Steel fy 415 MPa
Minimum Depth Required dmin 162
Depth Provided D 550 mm
Clear Cover c 50 mm
Effective Cover d' 58 mm
Effective Depth d' 492 mm
Spacing c/c in mm
Area of Steel
12# 16#
590 sqmm 192 c/c 341 c/c
590 sqmm 192 c/c 341 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
Ast across x direction 16 mm dia @ 125 mm c/c
Ast across y direction 16 mm dia @ 125 mm c/c
3 One Way Shear along x direction
Vu1 109 KN
ζv 0.123 MPa
ζc 0.260 MPa
Vc1 230 KN
One Way Shear Check OK
4 One Way Shear along y direction
Vu1 124 KN
ζv 0.140 MPa
ζc 0.260 MPa
Vc1 230 KN
One Way Shear Check OK
5 Two Way Shear
Vu2 627 KN
ζv 0.421 MPa
ks*ζc 1.118 MPa
Vc1 1666 KN
Two Way Shear Check OK
L= 1.80 meters
230 mm
300 mm
B= 1.80 meters
200 mm
16 mm dia @ 125 mm c/c
ng
width 1000 mm
Mulim/bd2 Mulim
2.76 668 KN-m
xumax/d xumax
0.48 236
SRB
a 0.7529
b -3.6105
c 0.2729
-p 0.0768
Ast 378
Min steel % 0.205
/c in mm Ast 378
20#
532 c/c
532 c/c Min Steel 590
Max Steel 19680
Ast 590
1608 sqmm
1608 sqmm Pt provided 0.1200
β 19.352
ks trial 1.266666666667
ks 1
550 mm
16 mm dia @ 125 mm c/c
width 1000 mm
Mulim/bd2 Mulim
2.76 668 KN-m
Rumax Section Check xumax/d xumax Rumax
0.138 7.1 0.48 236 0.138
SRB
a 0.7529
b -3.6105
c 0.2990
-p 0.0843
Ast 415
Min steel % 0.205
Ast 415
Min Steel 590
Max Steel 19680
Ast 590
Pt provided 0.1200
β 19.352
ks trial 1.26666666667
ks 1
Section Check
7.1