0% found this document useful (0 votes)
3 views1 page

S60L Compactsensors Manual ENG

The document is an instruction manual for the S60-PL series sensors, detailing installation, settings, and technical specifications. It provides guidance on positioning the sensors, adjusting sensitivity, and understanding LED indicators for operation status. Additionally, it includes safety warnings and compliance information regarding disposal and electrical standards.

Uploaded by

Muhammad Majar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views1 page

S60L Compactsensors Manual ENG

The document is an instruction manual for the S60-PL series sensors, detailing installation, settings, and technical specifications. It provides guidance on positioning the sensors, adjusting sensitivity, and understanding LED indicators for operation status. Additionally, it includes safety warnings and compliance information regarding disposal and electrical standards.

Uploaded by

Muhammad Majar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DIMENSIONS SETTING

50 Setting of S60-PL…B01
S60-PL...B01/C01/F01/G00 Position the sensor and reflector aligned on opposite sides.
Turn the sensitivity trimmer to the maximum position.
42 15 Moving the sensor both vertically and horizontally, determine the power
on and off points of the yellow LED (OUT) and then mount the sensor in
S60-PL SERIES the middle of the points defined.

2
Reduce sensitivity if very small objects have to be detected. Repeat
procedure reducing progressively the sensitivity in orde to improve
INSTRUCTION MANUAL aligngment.
Setting of S60-PL…F01/G00
Position the sensors aligned on opposite sides.

42
50
Turn the sensitivity trimmer to maximum: moving the sensor both
vertically and horizontally, determine the power on and off points of the

26.5
yellow LED (OUT) and then mount the sensor in the middle of the points

18x45°
CLASS 1 EN 60825-1 (2014)
LASER PRODUCT defined so that the yellow LED remains off.
If necessary, reduce sensitivity using the trimmer, in order to detect very
small targets. In order to improve alignment, repeat the procedure
detailed above whilst progressively reducing the sensitivity.

16
Setting of S60-PL…C01
Adjust the sentivity trimmer to minimum: the yellow A C
LED is off.
CONTROLS Position the target to detect in front of the sensor. B
11 6 14 M12 MAX
Turn the sensitivity trimmer clockwise until the yellow MIN
OUTPUT LED (S60-PL…B01/C01/F01)
LED turns ON (Target detected state, pos.A).
The yellow LED on indicates that the N.O. (normally open) output status
Ø15 Remove the target, the yellow LED turns OFF.
is closed.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON
POWER ON LED (S60-PL…B01/C01/F01/G00)
(Background detected state, pos.B).
The green LED indicates that the sensor is operating and the laser is 23.6 CABLE VERSION The trimmer reaches maximum if the background is not detected.
active. POWER ON LED (S60-PL...B01/C01/F01)
Turn the trimmer to the intermediate position C, between the two
TRIMMER (S60-PL …B01/C01/F01) positions A and B.
The trimmer can be used to adjust sensitivity; the operating distance OUTPUT LED (S60-PL...B01/C01/F01)
increases turning the trimmer clockwise.

Ø4
POWER ON LED (S60-PL...G00)
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
TEST FUNCTION (S60-PL…G00)
TRIMMER mm
Do not apply excessive torque when adjusting (max 40 Nmm). The TEST+ input can be used to inhibit the emitter and verify that the
system is correctly operating.
The receiver output should switch when the test is activated while the
INSTALLATION TECHNICAL DATA beam is uninterrupted.
The inputs activating voltage range is 10 … 30 Vdc, with respect to 0V
The sensor can be positioned by means of input (blue wire pin3).
the three housing’s holes using two screws Power supply: 10 … 30 Vdc limit values Connect the TEST+ input to 0V if not used.
(M4x25 or longer, 1.5 Nm maximum Ripple: 2 Vpp max.
tightening torque) with washers. Consumption
(output current excluded): 35 mA max. The sensors are NOT safety devices, and so MUST NOT be used in the
Various orientable fixing brackets to ease
the sensor positioning are available Outputs: N.O. and N.C.; PNP or NPN; 30 Vdc max. (short-circuit protection) (mod. B01/C01/F01) safety control of the machines where installed.
(please refer to the accessories listed in Ouput current: 100 mA max.
the general catalogue). Output saturation voltage: 2V
The operating distance is measured from
Response time: 250 s (mod. B01/C01); 333 s (F01)
the front surface of the sensor optics.
The M12 connector can be oriented at two Switching frequency: 2 kHz (mod. B01/C01); 1,5 kHz (F01) Datalogic S.r.l.
different positions using the specific fastening spring and rotating the Indicators: OUTPUT LED (YELLOW) (mod. B01/C01/F01) Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
block of 180°. POWER ON LED (GREEN) (mod. B01/C01/F01/G00) Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Setting: senstivity trimmer (mod. B01/C01/F01)
Helpful links at www.datalogic.com: Contact Us, Terms and
CONNECTIONS Operating mode: LIGHT mode on N.O. output / DARK mode on N.C. output (mod.C01)
DARK mode on N.O. output / LIGHT mode on N.C. output (mod.B01/F01) Conditions, Support.
The connections are compliant to the EN 60947-5-2 standard. Operating temperature: -10 … 50 °C
Storage temperature: -25 … 70 °C The warranty period for this product is 36 months. See General Terms
Electrical protection: Class 2 and Conditions of Sales for further details.
S60-PL…B01/C01/F01 S60-PL…G00
Operating distance (typical values): B01: 0.1…20 m on R2
BROWN 1 BROWN 1 Under current Italian and European laws, Datalogic is not obliged
+ 10 … 30 Vdc + 10 … 30 Vdc C01: 0…50 cm
to take care of product disposal at the end of its life. Datalogic
F01/G00: 0…60 m
WHITE 2 WHITE 2
recommends disposing of the product in compliance with local
Emission type: RED LASER: Class 1 EN 60825-1 (2014) (mod.B01/C01/G00)
N.C. OUTPUT TEST + laws or contacting authorised waste collection centres.
Class II CDRH 21 CFR PART 1040.10 (mod.B01/C01/G00)
BLACK 4 BLACK 4 Max. power  1 mW; Pulse = 4.2 S (mod.B01/C01); 5 S (mod.G00);
N.O. OUTPUT NOT USED © 2007 - 2017 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS
 = 630…680 nm; Frequency =33.5 kHz (mod.B01/C01); 10 kHz (mod.G00) RESERVED.  Without limiting the rights under copyright, no part of this
BLUE 3 BLUE 3
0V 0V Ambient light rejection: according to EN 60947-5-2 documentation may be reproduced, stored in or introduced into a
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) retrieval system, or transmitted in any form or by any means, or for any
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) purpose, without the express written permission of Datalogic S.p.A.
Housing material: ABS and/or its affiliates. Datalogic and the Datalogic logo are registered
2 1 Lens material: window in PMMA, lenses in glass and polycarbonate trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and
Mechanical protection: IP67 the E.U. All other trademarks and brands are property of their respective
owners. Datalogic reserves the right to make modifications and
3 4 M12 CONNECTOR Connections: 2 m  4 mm cable / M12 4-pole connector
improvements without prior notification.
Weight: 90 g. max. cable vers. / 40 g. max. connector vers.