Access Control Terminal
User Manual
Access Control Terminal·User Manual
User Manual
©2018 Hangzhou Hikvision Digital Technology Co., Ltd.
This manual is applied for access control terminal.
Product
Model Product Name
Serials
Access Control Terminal
DS-K1T801E
(EM Card)
DS-K1T801
Access Control Terminal
DS-K1T801M
(M1 Card)
It includes instructions on how to use the Product. The software
embodied in the Product is governed by the user license
agreement covering that Product.
About this Manual
This Manual is subject to domestic and international copyright
protection. Hangzhou Hikvision Digital Technology Co., Ltd.
(“Hikvision”) reserves all rights to this manual. This manual cannot
be reproduced, changed, translated, or distributed, partially or
wholly, by any means, without the prior written permission of
Hikvision.
Trademarks
and other Hikvision marks are the property of
Hikvision and are registered trademarks or the subject of
applications for the same by Hikvision and/or its affiliates. Other
trademarks mentioned in this manual are the properties of their
respective owners. No right of license is given to use such
trademarks without express permission.
i
Access Control Terminal·User Manual
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
REGARDING THIS MANUAL. HIKVISION DOES NOT WARRANT,
GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE
USE OF THE MANUAL, OR THE CORRECTNESS, ACCURACY, OR
RELIABILITY OF INFORMATION CONTAINED HEREIN. YOUR USE OF
THIS MANUAL AND ANY RELIANCE ON THIS MANUAL SHALL BE
WHOLLY AT YOUR OWN RISK AND RESPONSIBILITY.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN
NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES,
OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL,
CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,
INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION, SECURITY BREACHES, OR LOSS
OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE
OF OR RELIANCE ON THIS MANUAL, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY OR CERTAIN DAMAGES, SO SOME OR ALL
OF THE ABOVE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO
YOU.
Support
Should you have any questions, please do not hesitate to contact
your local dealer.
Warnings Follow Cautions Follow these
these safeguards to precautions to prevent
ii
Access Control Terminal·User Manual
prevent serious injury potential injury or
or death. material damage.
Warnings
All the electronic operation should be strictly compliance with
the electrical safety regulations, fire prevention regulations and
other related regulations in your local region.
Please use the power adapter, which is provided by normal
company. The power consumption cannot be less than the
required value.
Do not connect several devices to one power adapter as
adapter overload may cause over-heat or fire hazard.
Please make sure that the power has been disconnected before
you wire, install or dismantle the device.
When the product is installed on wall or ceiling, the device shall
be firmly fixed.
If smoke, odors or noise rise from the device, turn off the
power at once and unplug the power cable, and then please
contact the service center.
If the product does not work properly, please contact your
dealer or the nearest service center. Never attempt to
disassemble the device yourself. (We shall not assume any
responsibility for problems caused by unauthorized repair or
maintenance.)
Cautions
Do not drop the device or subject it to physical shock, and do
not expose it to high electromagnetism radiation. Avoid the
iii
Access Control Terminal·User Manual
equipment installation on vibrations surface or places subject to
shock (ignorance can cause equipment damage).
Do not place the device in extremely hot (refer to the
specification of the device for the detailed operating
temperature), cold, dusty or damp locations, and do not expose
it to high electromagnetic radiation. The appropriate operation
temperature is 0℃ to +45℃, and the storage temperature
should be -10℃ to +55℃.
The device cover for indoor use shall be kept from rain and
moisture.
Exposing the equipment to direct sun light, low ventilation or
heat source such as heater or radiator is forbidden (ignorance
can cause fire danger).
Do not aim the device at the sun or extra bright places. A
blooming or smear may occur otherwise (which is not a
malfunction however), and affecting the endurance of sensor at
the same time.
Please use the provided glove when open up the device cover,
avoid direct contact with the device cover, because the acidic
sweat of the fingers may erode the surface coating of the device
cover.
Please use a soft and dry cloth when clean inside and outside
surfaces of the device cover, do not use alkaline detergents.
Please keep all wrappers after unpack them for future use. In
case of any failure occurred, you need to return the device to
the factory with the original wrapper. Transportation without
the original wrapper may result in damage on the device and
lead to additional costs.
Improper use or replacement of the battery may result in
hazard of explosion. Replace with the same or equivalent type
only. Dispose of used batteries according to the instructions
provided by the battery manufacturer.
iv
Access Control Terminal·User Manual
Table of Contents
1 Overview ................................................................................... 1
2 Appearance ............................................................................... 2
2.1 Appearance of the Termianl ................................................. 2
2.2 Description of Keypad Items ................................................. 3
3 Terminal Connection ................................................................. 4
3.1 Terminal Description ............................................................ 4
3.2 External Device Wiring ......................................................... 4
4 Installation ................................................................................ 5
4.1 Mounting with Gang Box ...................................................... 6
4.2 Mounting without Gang Box................................................. 7
5 Keypad Operation ..................................................................... 9
5.1 Working Mode ..................................................................... 9
5.2 Programming Mode ........................................................... 10
v
Access Control Terminal·User Manual
1 Overview
DS-K1T801 Series Standalone Access Control
Terminal
Main Features
Equipped with 32-bit high-speed processor
Supports EM card and M1 card reading
Supports authentication methods of card, card and password,
or password
Doorbell ring design
Supports 3 thousand card No. storage
Unlocking overtime alarm
Data can be permanently saved after power-off
Watchdog program to ensure the basic function of the
terminal.
Supports NFC tag anti-cloning
1
Access Control Terminal·User Manual
2 Appearance
2.1 Appearance of the Termianl
Please refer to the following content for detailed information of
the terminal.
Appearance of Access Control Terminal
Description of Access Control Terminal
No. Name Description
First Line: display date
LCD Second Line: display time
1 Display
Screen Third Line: display authentication information
or swiping status
Slow Flashing Card reader is working
Green properly.
Power
2 Indicator Solid Green for The operation of pressing
a time period keys or swiping card is valid.
2
Access Control Terminal·User Manual
The operation of pressing
Solid Red for a
keys or swiping card is
time period
invalid.
Numeric key 0 to 9, Clearing key *, and
3 Keypad Confirming key #
4 Door Bell Door Bell Ring
Wiring Wire the device with power supply, doorbell,
5
Terminals and door lock.
6 Jumper Control the status of the lock relay.
When rebooting the device, hold the button
Initializati for about 8s to enter the initialization mode.
7
on Button When initializing, the device buzzer will beep
for 3s.
2.2 Description of Keypad Items
Description of Keys
No. Description
0 to 9 Numeric Keys: Enter number in the
textbox.
* Exiting Key: Click the key to exit the
menu.
# Confirming Key: Click the key to
confirm operations.
3
Access Control Terminal·User Manual
3 Terminal Connection
3.1 Terminal Description
The following table shows the terminals description.
Terminal Description
Description Color
12V DC Red
Power Input
GND Black
Bell+ Orange
Bell
Bell- Yellow
BUTTON_IN Purple
DOOR_COM Green
DOOR_NO/NC Blue
Door Lock
SENSOR_IN White
GND Black
12V_LOCK Brown
3.2 External Device Wiring
Power Supply Wiring Doorbell Wiring
Power Supply Doorbell Wiring
Connection Diagram Diagram
4
Access Control Terminal·User Manual
Door Button Wiring Door Lock Wiring
Door Button Wiring Door Lock Wiring
Diagram Diagram
Door Magnetic Wiring
Door Magnetic Wiring Diagram
4 Installation
Before you start
5
Access Control Terminal·User Manual
Please make sure that the device in the package is in good
condition and all the assembly parts are included.
Make sure that all the related equipment is power-off during
the installation.
Check the specification of the products for the installation
environment.
Check whether the power supply is matched with your AC
outlet to avoid damage.
If the product does not function properly, please contact your
dealer or the nearest service center. Do not disassemble the
camera for repair or maintenance by yourself.
Please make sure the wall is strong enough to withstand three
times the weight of the camera and the mounting.
4.1 Mounting with Gang Box
Steps:
1. Route the cables through the cable hole of the mounting base.
2. Align the screw holes on mounting base with the screw holes
on gang box.
3. Fix the mounting base on the gang box with inserting two
KA4*22-SUS screws (supplied) into the two screw holes.
Install the Mounting Attach the Front
6
Access Control Terminal·User Manual
Base Cover
4. Connect the corresponded cables.
5. Align the buckle of the front cover with the slot of the
mounting base, and hang the front cover onto the mounting
base. Make sure the buckle is embedded into the slot.
6. Secure the front cover with inserting and tightening two screws
on the bottom of device.
Secure the Front Cover
4.2 Mounting without Gang Box
Steps:
1. Drill 4 screw holes in the wall according to the holes of the
mounting base, and then insert expansion screws sockets (not
supplied) into the holes.
2. Route the cables through the cable hole of the mounting base.
3. Align the screw holes on the base with the screw sockets on the
wall.
4. Attach the mounting base on the wall with Inserting 4
KA4*22-SUS screws (supplied) into the 4 screw sockets.
7
Access Control Terminal·User Manual
Install the Attach the Front
Mounting Base Cover
5. Connect the corresponded cables.
6. Align the buckle of the front cover with the slot of the
mounting base, and hang the front cover onto the mounting
base. Make sure the buckle is embedded into the slot.
7. Secure the front cover with inserting and tightening two screws
on the bottom of the device.
Secure the Front Cover
8
Access Control Terminal·User Manual
5 Keypad Operation
Access Control Terminal Working Mode
The access controller involves two modes: working mode and
programming mode.
5.1 Working Mode
After the access controller is powered on, its LED status indicator
turns green and blinks for 1 time firstly. Then it turns red and
blinks for 3 times, and the buzzer buzzes a beep sound indicating
the initialization process is completed.
The controller supports swiping card, E series support EM
card, and M series support M1 card.
The controller also supports entering card No. by keypad. For
example, you can enter the card number by ending with #.
Enter the * key to clear the valid data input before, for example,
the valid data of “123456*7890123#” is “7890123”.
Enter [the programming password] + [*] + [0] + [#] to enter the
programming mode. The default programming password is 12345.
When using the access control terminal, it will send out different
sound prompt and the LED indicator on it has different statues.
For the detailed information, refer to the table below.
Sound LED Indicator
Prompt Status Description
Green and The access controller is
Blinking Slowly working normally.
Pressing keys prompt;
One Beep
Swiping card prompt.
Two Rapid Solid Green The operation of pressing
Beeps keys or swiping card is valid.
Three Slow Solid Red The operation of pressing
Beeps keys or swiping card is invalid.
Two Rapid The operation of entering the
9
Access Control Terminal·User Manual
Beeps programming mode is
successful.
Three Slow The operation of entering the
Beeps programming mode is failed.
Delayed door alarm (the door
Beep for 10
is opened over the time
Seconds limitation)
5.2 Programming Mode
After entering the programming mode, LED status indicator turns
green and blinks rapidly.
After entering “*#”, the buzzer buzzes two rapid beeps for
switching the programming mode to the normal mode.
Changing Programming Password:
Command:
[00]+ [5-bit new programming password]+[Enter 5-bit new
programming password again]+[#]
Sound Prompt Description
3 Slow Beeps The operation of changing password is
failed.
2 Rapid Beeps The operation of changing password is
successful.
Adding User
Two ways are allowed to add the user: single adding and
continuous adding.
Steps:
1. Enter the user ID.
2. Swiping the card.
3. Enter the 4-bit to 8-bit card password.
The step 3 can be omitted.
10
Access Control Terminal·User Manual
Single adding:
[01] +[4-bit code]+ [swipe card 1]+ [4-bit to 8-bit card
password]+[#]
Continuous adding:
[01] +[4-bit code]+
[swipe card 1]+ [4-bit to 8-bit card password]+ [#]
[swipe card 2]+ [4-bit to 8-bit card password]+ [#]…
Enter the 4-bit user ID, e.g. “0001” (note: the 4-bit user ID ranges
from 1 to 3000).
Sound Prompt Description
3 Slow Beeps Enter another user ID for the current user
ID has been applied.
2 Rapid Beeps The user ID is valid, wait for swiping.
1 Beep Swipe the card.
When adding cards continuously, different beeps stand for
different meanings.
Sound Prompt Description
1 Beep Swipe the card.
5 Slow Beeps The card is failed to be added for it has been
registered.
3 Slow Beeps The user ID exists.
2 Rapid Beeps The card is successfully added.
Deleting User
Two ways are allowed to delete the user: swiping card, entering
user ID, or entering card password.
Swiping card:
[02] +[swipe the card]+[#]
Entering user ID:
[02] +[4-bit code]+[#]
11
Access Control Terminal·User Manual
Entering card password:
[11]+[4-bit to 8-bit password]+[#]
The user with the input card password will be deleted.
Swipe the card and enter “#” after the buzzer buzzes one beep.
Sound Prompt Description
1 Beep Swipe the card.
3 Slow Beeps The operation of deleting card is failed.
2 Rapid Beeps The operation of deleting card is
successful.
Enter the user ID and enter “#”.
Sound Prompt Description
3 Slow Beeps The operation of deleting card is failed.
2 Rapid Beeps The operation of deleting card is
successful.
Setting Card Password
Add card password:
[10]+[4-bit code]+[4-bit to 8-bit password]+[#]
Change card password:
[10]+[4-bit code]+[4-bit to 8-bit password]+[#]
The password here is the new password.
The card password can contain 0 only.
Supports add card password without adding the card.
Up to 3000 groups of card passwords can be added.
If the authentication mode is Card, opening door by only
entering the card password is available. For details about
setting authentication mode, see Setting Authentication Mode
in this section.
12
Access Control Terminal·User Manual
The card password cannot be the same with the super
password.
Setting Authentication Mode:
Command:
[03] + [data 1] + [#]
The value of data 1 can be 0, 1, or 2.
Value Description
0 Card only
1 Card + Password
Other values Failed
Setting Access Parameters:
Command:
[04] + [data 1]+ [data 2] +[data 3]+ [data 4] +[#]
Data 1 is a 3-bit value, ranging from 001 to 255, and stands
for the door open time;
Data 2 is a 2-bit value, ranging from 00 to 99, and stands for
the door open timeout;
Data 3 is a 1-bit value, and stands for door magnetic type: 0-
normally closed, and 1- normally open.
Data 4 is a 1-bit value, and stands for the button type:
0-normally close, and 1- normally open.
Sound Prompt Description
3 slow beeps The operation of editing the access
parameters is failed.
2 rapid beeps The operation of editing the access
parameters is successful.
13
Access Control Terminal·User Manual
Setting Super Password:
Command:
[05] + [8-bit super password] + [8-bit super password] +[#]
Sound Prompt Description
3 Slow Beeps The operation of editing the super
password is failed.
2 Rapid Beeps The operation of editing the super
password is successful.
If the 8-bit super password is set as 00000000, which means the
super password is disabled.
Enabling Controller:
Command:
[06]+ [data 1] + [data 2] +[#]
Member Length Function Description
Data 1 1 bit Whether to enable the 0-disable;
key sound 1-enable
Data 2 1 bit Whether to enter the 0-no, 1-yes
card No. by keypad
Sound Prompt Description
3 Slow Beeps The operation is failed.
2 Rapid Beeps The operation is successful.
Clearing Card:
Command:
[07]+ [5-bit programming password]+[#]
Sound Description
Prompt
3 Slow Beeps The operation of clearing card is failed.
14
Access Control Terminal·User Manual
2 Rapid Beeps The operation of clearing card is successful.
And after 1 second, the controller starts
deleting all cards.
Restoring Default Settings:
Command:
[08]+ [5-bit programming password]+[#]
Sound Description
Prompt
3 Slow Beeps The operation of restoring default settings is
failed.
2 Rapid Beeps The operation of restoring default settings is
successful. And after 5 seconds, the controller
starts restoring the factory settings.
Rebooting the Device:
Command:
[09]+ [5-bit programming password]+[#]
Sound Prompt Description
3 Slow Beeps The operation of rebooting is failed.
2 Rapid Beeps The operation of rebooting is successful. And
after 1 second, the controller starts rebooting.
In the programming mode, the buzzer buzzes two beeps and the
controller is switched to the normal mode after no operation for
30 seconds.
15
Access Control Terminal·User Manual
16 UD05638B-E