0% found this document useful (0 votes)
267 views4 pages

Hydrins2 0510uk

The HydrINS 2 is an electromagnetic insertion flow meter that provides accurate bi-directional flow measurement for water distribution pipelines. It can be easily installed through a hot tap with no interruption to supply. The probe measures flow velocity based on Faraday's law of induction and includes advanced processing to measure low velocities. It has a long battery life, various output options, and Winfluid software for programming and data retrieval.

Uploaded by

lwarlockl
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
267 views4 pages

Hydrins2 0510uk

The HydrINS 2 is an electromagnetic insertion flow meter that provides accurate bi-directional flow measurement for water distribution pipelines. It can be easily installed through a hot tap with no interruption to supply. The probe measures flow velocity based on Faraday's law of induction and includes advanced processing to measure low velocities. It has a long battery life, various output options, and Winfluid software for programming and data retrieval.

Uploaded by

lwarlockl
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Integrated measuring systems for the whole water cycle

DRINKING

Electromagnetic Insertion Probe with optional Display Panel

HydrINS 2
Display

Velocity up to 2 cm/s Accuracy +/- 2 mm/s Ease of installation with no interruption to supply Long battery life up to 1 years 0 IP 68

HydrINS 2

TE

Application
The HydrINS 2 flowmeter, developped by Hydreka, is an easily deployed and cost effective flow meter providing highly accurate bi-directional measurement for water distribution and raw water pipelines. The highly versatile unit is widely used throughout the world and available in various lengths, equally well deployed for permanent or portable applications. HydrINS 2 can be used throughout the water distribution network: etering at resevoirs, Treatment works M umping stations, water pipes P oning and DMA Z ight flow monitoring and meter testing. N

Principle
In accordance with Faradays law, a voltage is induced in a conductor that is moved through a magnetic field. In the electromagnetic principle of measurement, the flowing and electrically conductive fluid represents the moving conductor. The induced voltage is then proportional to the flow velocity and is fed to the amplifier by a pair of electrodes on the sensor. The methodology is to place the sensor on the centre line of the pipeline and at the 1/8 for particular condition. The velocity profile allows to guarantee the accuracy.

Description:
The HydrINS 2 insertion flowmeter HydrINS is constituted of : high accuracy electromagnetic sensor : A The unit uses stainless steel electrodes to enhance measurement accuracy and avoid drift. The mechanical conception is designed to ensure maximum resistance and protection to the sensor which is mechanically isolated from the stem end. n board micro-controller inside the O probes head : HydrINS 2 uses advanced processing tecnhiques which enables a wide variety of sampling regimes to be set, like signal quality, to suit a wide variety of applications. 2 versions : self contained with or without display (over 10 years life depending on options) or powered version via its display. Large measurement range (from 2 cm/s to 5 m/s) and its accuracy of 2% enables accuracy and minimum night flow monitoring (MNF) Every unit comes with re-enforced stem with an anti-ejection chain, locking nut and insertion point clamp to ensure correct and safe installation on pressurised water network. Communication via watertight military specification connector. The new HydrINS 2 can be supplied with a large LCD display unit giving instant readouts of all measurements. It is powered by long life lithium batteries (up to 10 years), or alternatively via external DC power. It has alarm and pulse outputs with two 4-20 mA outputs available as an option.
Display

Probe head with flow direction

Detachable alignment bars

Installation
The HydrINS 2 is a robust, watertight and compact flowmeter. The integral transmitter enables multiple telemetry options or simple totalizer. Available in different lengths to suit pipe diameter from 100 mm to over 2000 mm.

Insertion reference mark

It is equally well deployed for permanent or portable applications inserted through standard under pressure taping with Mil-Spec no interruption to supply. connector for communication The flowmeter Hydrins is used by and pulse output inserting the electromagnetic sensor at the centre line or 1/8. The insertion Chain stem length is validate by a preliminary measurement of the pipe Internal Clamp ring diameter by using the diameter gauge. to prevent spar dropping through Push fit connector at the tip of the gland probe enable pressure measurement.
Pressure quick fit connector

Gauge
Sensor

Software
The Winfluid software under Pc or Pda enables the programmation, data retrieval and data processing of the HydrINS 2 and any logger connected to. Hydreka has developped, since many years, expertise on flow measurements and in particular on velocity profile for flow analysis.

PDA

Velocity Profile

Deployment Modes

PC / Laptop

Secure Server

Internet Download

Mobile Phone

HydrINS 2 SCADA linked HydrINS 2 with display & data logger

Multilog LX GSM HydrINS 2 transmits pulse data up to 500 m to a SCADA system.

HydrINS 2 transmits data up to 200 m to the display unit for instant flow and alarm data. The logger stores data for transmission and later analysis.

Vista plus

HydrINS 2 with data logger


LoLog Vista+ for local download Multilog for Cellular telemetry

HydrINS 2 with display linked to SCADA


The display unit sends data up to 200 m by pulse or via 4-20 mA for analysis.

Key Benefits

Operational
Bi-directional flow measurement Hot tap installation with no interruption to supply Easily deployed, moved and calibrated Long battery life, 4 to 10 years, depending on options Versatile can be deployed over a large range of pipe diameters from 100 mm to over 2000 mm High quality digital signal processing gives accurate measurement of low velocities (to 2 cm/s at 2 mm/s) Optional display unit which can be deployed up to 200 m away giving flow and alarm readings. Robust and watertight (IP68) with easy maintenance and calibration to ensure long term accuracy Velocity profiling to validate accuracy of measurement point and many measurement options

Economic
Highly cost effective flowmeter Ease of installation compare to traditional electromagnetic magmeter or mechanical flowmeter. Bring under control you unaccounted for water revenue Water meter check campaign to decrease billing issue due to over/undercounting. Durability and trust in the equipment you can easily install or remove for calibration.

Technical specifications
Measurement range Accuracy Units Power Sensor Information Internal logging Bi-directional from 0.02 m/s to 5 m/s, limited only by the stability of the probe in the flow. Fluid conductivity needs to be minimum of 20 s/cm. Point velocity: 2 mm/sec or 2% of value whichever is greater. Selectable: mm, metres, feet, litres, Megalitres, m3, ft3, ImpGal, USGal, MegaImpGal, MegaUSGal, seconds, minutes, hours, days 9-29 VDC. Internal lithium batteries giving 4 years optional Calibration, serial no, date of calibration Negative Totalizer / Positive Totalizer / Net Totalizer RS 232 Programmable point velocity, average velocity, instantaneous flow, totalised volume, signal quality 2 pulse outputs, isolated open collector. Can be 1 channel positive flow and 1 channel negative flow or 1 channel flow and 1 direction. Maximum frequency 50 Hz IP68 Watertight 10 way mil spec connector Electronics -20 to +60C (-4F to 140 F) Insertion element: non frozen water up to +60 C (140F) 20 bar. Integral to BSP quick fit pressure connector IP68/NEMA6 for immersion to 10 m (with connectors secured) Connection on a 1 inch hot tap BSP (25 mm). Safety chain 300 mm (11.81), 500 mm (19.69), 700 mm (27.56) and 1000 mm (39.37) Sensor diameter 22 mm (0.87), stem diameter 19 mm (0.75), head diameter 106 x 80 mm high (4.17 x 3.15) <3.5 kg (<7.7 lb) Insertion components: Stainless Steel 316. PVC No WRAS 0307509. Nitrile joints No 0470NBRFD WRAS approved. External components: Stainless Steel 316. Bronze C2121 24 months Calibrated to reference meters to COFRAC procedures and traceability. Internal pipe measuring gauges available. 1" diameter in either 880/1040 or 1250mm lengths, 1.5" diameter in 1250 mm length or 2" diameter in 1250 mm length
RS 232. 2 PULSE. Internal lithium batteries of 3, 6 V - 19 A/h Power Supply 4 10 years dependent on set up options External batteries option or 20V-28VDC Battery compartment sealed from electronics LCD : Backlit 16 characters, 2 lines Push button control displaying velocity, flow, positive Totalizer, negative Totalizer, net Totalizer, alarm Alarms : 2 dry contacts software programmable via RS232. No water, sensor fault, low battery, low or high flow, power failure Interconnectivity : 10 m display to probe supplied as standard. Maximum availability 200 m Communications : Probe and display programming via RS232. Optional blue tooth available. Ingress Rating : IP68 to 2 m submersion Weight :1 kg (2.2lb) Power Supply 20-28 V DC
HydrIns 2 version 1 - Fvrier 20 0 - UK - DALTON - 324 536 267 00036 - Hydreka se rserve la possibilit de modifier les caractristiques techniques des produits sans pravis. 1

Outputs

Connector Software

Winfluid

HydrINS 2

Temperature Range Max Pressure Ingress Rating Installation Insertion lengths Dimensions Weight Construction Warranty Certification

Gauge

Gauge

Display A

Output

Display C

Output

RS232. 2 Outputs 4.20 mA and 4 outputs PULSE

Products available to rent or buy. Please contact us for more information.

www.hydreka.fr
34, Route de Saint Romain - 69450 - St Cyr au Mont dOr - France Tl. +33 (0)4 72 53 1 53 - Fax +33 (0)4 78 83 44 37 - e-mail : [email protected] 1

You might also like