FiberOpticCable Catalogue
FiberOpticCable Catalogue
ATHENS AIRPORT
PIRAEUS PORT
TUNNEL IN PARIS
www.ramcro.it
THE MEANING OF THE SYMBOLS FOR
FIBRE OPTIC CABLES
SLT SINGLE LOOSE TUBE
MLT MULTI LOOSE TUBE CABLES
SA CORRUGATED STEEL TAPE
NMA NON METALLIC STRENGHT MEMBER
DOUBLE ARMOR TWO LAYERS OF GALVANIZED
DA
STEEL TAPE
SJ SINGLE JACKET (SHEATH)
DJ DOUBLE JACKET (SHEATH)
-A AERIAL CABLE
-P FIBER OPTIC + POWER HYBRID CABLE
LSZH LOW SMOKE ZERO HALOGEN SHEATH
ADSS ALL DIELECTRIC SELF SUPPORTING CABLE
DIN VDE 0888 OPTICAL FIBER CABLES STANDARD
A- OUTDOOR CABLE
B ARMORING
GLASS YARN NON METALLIC ARMORING FOR RO-
(BN)
DENT PROTECTION
LOOSE BUFFER TUBE, FILLED
D GLASS YARN NON METALLIC ARMORING FOR RO-
DENT PROTECTION
2 E SINGLE MODE FIBER
F FILLING COMPOUND IN THE CABLE CORE
G MULTI MODE FIBER
J· INDOOR CABLE
(L) LAMINATED ALUMINIUM TAPE
DRY SWELLABLE MATERIAL IN THE CABLE CORE
Q
(DRY CORE)
ARMORING BY LAMINATED, CORRUGATED, LONGITU-
(SR)
DINAL, OVERLAPPED STEEL TAPE
Y POLYVINYL CHLORIDE JACKET (SHEATH)
2Y POLYETHYLENE JACKET (SHEATH)
NON-METALLIC ANTI-BUCKLING ANG STRENGHT
(ZN)
MEMBERS
www.ramcro.it
SINGLE LOOSE TUBE, SINGLE SHEATH, NON
single loose
SLT-MNA-SJ,(A-DQ(ZN)B2Y)
METALLIC ARMOURED DUCT TYPE
INTERNAL & EXTERNAL FIBER OPTIC CABLE
tube
Applications
• Light weight structure enables easy and fast installation
• Non Metallic / All dielectric structure prevents electromagnetic interference
• Rodent Protection and waterproof
• Preferred for LAN, WAN applications for structural cabling and premise networks
• Optional LSZH sheath enables usage as Indoor cable as well as Outdoor
Construction:
1 - Outer PE Sheath (Optional LSZH sheath)
2 - E-Glass yarn
3 - Loose Tube (PBT)
4 - Water Resistive Tube filling Compound
5 - Optical fibers
6 - Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count: 2 to 24
Cable Weight (kg/Km): 55
www.ramcro.it
SINGLE LOOSE TUBE, SINGLE SHEATH,
single loose
SLT-SA-SJ/(A-DQ(ZN)SR)2Y)
CORRUGATED STEEL TAPE ARMOURED,
DIRECT BURIAL / DUCT TYPE
Applications
tube
• Light weight structure enables easy and fast installation
• Smaller diameter permits easy handling
• Rodent Protection and waterproof
• Application in PE Pipes by blowing / plough technique
• Preferred for LAN, WAN, MAN application for structural cabling and Premise networks
• Possibility of usage as Indoor Cable as well as Outdoor due to light structure
• Optional supporting or galvanized Steel Wire or Power Cable:
SLT-SA-SJ-A (A-DQ(ZN)(SR)2YT)
SLT-NMA-SJ-A (A-DQ(ZN)B2YT)
SLT-NMA-SJ-P (A-DQ(ZN)B2Y+POWER)
Construction:
1 - Outer PE Sheath (Optional LSZH Yarn)
2 - Non Metallic Strenght element
(glass Yarn or Aramid Yarn)
3 - Core Wrapping(s)
4 - PBT Tube
5 - Core Filling Compound
6 - Optical Fibers
7 - Water Resistive Tube Filling Compound
8 - Non Metallic Central Strenght Member
9 - Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count: 2 to 24
Cable Weight (kg/Km): 85
4
Outer Diameter (mm): 7,5
Standards Tensile Strenght (N)
References: (IEC 794-1-E1): 1200
Crush Strength (N/10cm)
- IEC 60793 (IEC 794-1-E3: 2500
- IEC 60794
Min Permissible
Bending Radius (mm)
(IEC 794-1-E 11): 15xo static & 20xo dynamic where o is cable outside
diameter in mm
Temperature Range (°C)
(IEC 794-1-F-1): During Operation: -40 °C to + 70 °C
During Installation: -30 °C to + 60 °C
www.ramcro.it
MULTI LOOSE TUBE, SINGLE SHEATH,
MLT-NMA-SJ(A-DF(ZN)B2Y)
NON METALLIC ARMOURED / DUCT
multi loose
Applications
• Light weight structure enables easy and fast installation
• Possibility of usage as Indoor Cable as well as Outdoor due to light structure
tube
• Non Metallic Construction / All dielectric structure prevents electromagnetic interference
and enables application in power lines side by side with Energy Cables
• Waterproof
• Rodent protection-provided by adequate amount of E glass yarn
• Suitable to be installed with blowing /ploughing method
• Optional LSZH Sheath
• Optional version with external Power Cable: MLT-NMA-SJ-P (A-DF(ZN)B2Y+POWER)
Construction:
1 - Outer PE Sheath (Optional LSZH Yarn)
2 - Non Metallic Strenght element
(glass Yarn or Aramid Yarn)
3 - Core Wrapping(s)
4 - PBT Tube
5 - Core Filling Compound
6 - Optical Fibers
7 - Water Resistive Tube Filling Compound
8 - Non Metallic Central Strenght Member
9 - Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Other type of Multi Loose Tube, Single Sheath, Non Metallic Standards
Armored/Duct References:
www.ramcro.it
MLT-NMA-SJ-DRY(A-DQ(ZN)B2Y) MULTI LOOSE TUBE, SINGLE SHEATH,
NON METALLIC ARMOURED/DUCT,
multi loose TYPE DRY CORE CABLE
Applications
tube
• Light weight structure enables easy and fast installation
• Possibility of usage as Indoor Cable as well as Outdoor due to light structure
• Non Metallic Construction / All dielectric structure prevents electromagnetic interference
and enables application in power lines side by side with Energy Cables
• Waterproof
• Rodent protection-provided by adequate amount of E glass yarn
• Suitable to be installed with blowing /ploughing method
• Optional LSZH Sheat
Construction:
1. Outer PE Sheath (Optional LSZH Yarn)
2. Non Metallic Strength element (glass Yarn or
Aramid Yarn)
3. Water Swelling Tape
4. PBT Tube
5. Water Swelling Yarn
6. Optical fibers
7. Water Resistive Tube filling Compound
8. Non Metallic Central Strength Member (FRP)
9. Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strenght (N)
(IEC 794-1-E1): 1200 (Min.) to. 6000
Crush Strength (N/10cm)
(IEC 794-1-E3): 3000
Min Permissible Bending
Radius (mm) (IEC 794-1-E
6 11): 15xo static & 20xo dynamic where o is cable outside diameter
in mm
Temperature Range (°C)
(IEC 794-1-F-1): During Operation: -40 °C to + 70 °C
Standards During Installation: -30 °C to + 60 °C
References:
Other type of Multi Loose Tube, Single Sheath, Non Metallic Armored/
- IEC 60793 Duct Type Dry Core Cable
- IEC 60794
Cable Diameter Aprx Cable Weight
Fiber Count Buffer Count Filler Count (mm) (Kg/Km)
4 1 5 12 100
6 1 5 12 100
8 1 (2) 5 (4) 12 100
10 5 1 12 100
12 1 (3,2) 5 (3,4) 12 100
16 4 (2) 2 (4) 12 100
24 6 (2,4) 0 (4,2) 12 110
36 6 (3) 0 (3) 12 110
48 6 (4) 0 (2) 13 120
60 5 1 13 130
72 6 0 13 130
96 8 0 15 160
144 12 0 20 260
192 16 0 23 290
www.ramcro.it
MULTI LOOSE TUBE, SINGLE SHEATH,
MLT-SA-SJ(A-DF(ZN)(SR)2Y
CORRUGATED STEEL TYPE ARMORED, DIRECT
multi loose
BURIAL/ DUCT TYPE
Applications
tube
• Light weight but heavy duty direct burial / duct usage
• Single sheath enables easy and fast installations
• Suitable to be installed and used in harsh environments under heavy weather
conditions
• Rodent Protection and waterproof
• Application both as backbone cable for WAN Telecommunication Systems and
as data lines for LAN / Structure Cabling
Construction:
1. Outer PE Sheath (Optional LSZH Yarn)
2. Corrugated Steel Tape Armored
3. Non Metallic Strength element (glass Yarn
or Aramid Yarn)
4. Core Wrapping(s)
5. Core filling Compound
6. PBT Tube
7. Water Resistive Tube filing Compound
8. Optical fibers
9. Non Metallic Central Strength Member
(FRP)
10. Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
www.ramcro.it
MULTI LOOSE TUBE
Multiloose tube, double sheath, double layer swa and spa galva-
multi loose
nized steel type armored, direct burial/duct type
Applications
• Heavy duty cable for direct burial / duct usage
• Suitable to be installed and used in hard environments under heavy weather
MLT-DA-DJ
tube
conditions
• Galvanized Steel Armor and Second Jacket provides protection against Rodents,
moisture and all external effects. Waterproof
• Aluminum foil provides extra protection against moisture
• Suitable to be used for all type of underground application
• To be used as backbone cable for WAN telecommunication systems
• Two layers of galvanized steel tapes helically overlapped around the inner jacket
to improve the mechanical strength of the cable
Construction:
1. Outer PE Sheath
2. Crepe Paper
3. Helically Applied Double layer of Galvanized
Steel Tape by overlapping method
4. Crepe Paper
5. Inner PE Sheath
6. Aluminum Foil
7. Aramid Yarn for tensile strength
8. Core Wrapping(s)
9. Core filling Compound
10. Ripcord
11. PBT Tube
12. Water Resistive Tube filling Compound
13. Optical fibers
14. Non Metallic Central Strength Member
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strenght (N)
(IEC 794-1-E1): 3000 (Min.) to. 10000
www.ramcro.it
MULTI LOOSE TUBE
MLT-SA-DJ(A-DF(ZN)2Y(SR)2Y
Multiloose tube, double sheath, corrugated steel tape armored,
multi loose
direct burial / duct type
Applications
• Heavy duty cable for direct burial /duct usage
• Suitable to be installed and used in harsh environments under heavy weather conditions
tube
• Corrugated Steel Armor and Second Jacket provides protection against Rodents,
moisture and all external effects
• To be used as backbone cable for MAN, WAN, LAN applications and GSM, CATV,
SMATV networks
• Rodent protection and waterproof
• Possibly of installation with blowing / plough technique into PE pipes or applied
directly underground
Construction:
1. Outer PE Sheath
2. Corrugated Steel Tape Armored
3. Inner PE Sheath
4. Aramid yarn for tensile strength (or Glass
Yarn)
5. Core Wrapping(s)
6. Core filling Compound
7. Ripcord
8. PBT Tube
9. Water Resistive Tube filling Compound
10. Optical fibers
11. Non Metallic Central Strength
Member(FRP)
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
www.ramcro.it
MLT-NMA-DJ/(A-DF(ZN)2YB2Y) MULTI LOOSE TUBE
Multiloose tube, double sheath, non metallic armored, direct
multi loose
burial / duct type
Applications
• Heavy duty cable for direct burial / duct usage
• Suitable to be installed and used in hard environments under heavy weather conditions
• Galvanized Steel Armor and Second Jacket provides protection against Rodents, moisture
tube
and all external effects. Waterproof
• Aluminum foil provides extra protection against moisture
• Suitable to be used for all type of underground application
• To be used as backbone cable for WAN telecommunication systems
• Two layers of galvanized steel tapes helically overlapped around the inner jacket to improve
the mechanical strength of the cable
Construction:
1. Outer PE Sheath
2. Non metallic strength member (Aramid Yarn or
Glass Yarn)
3. Inner PE Sheath
4. Core Wrapping(s)
5. Core filling Compound
6. PBT Tube
7. Optical fibers
8. Water Resistive Tube filling Compound
9. Non Metallic Central Strength Member(FRP)
10. Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strenght (N)
(IEC 794-1-E1): 2000 (Min.) to. 5000
www.ramcro.it
MULTI LOOSE TUBE
MLT-SA-DJ(A-DF(ZN)2Y(SR)2Y
Multiloose tube, double sheath, adss aerial type
multi loose
Applications
• Aerial cable type without Steel Messenger Wire
• Aerial installation between the poles with the help of special installation / suspension
tube
equipment
• All dielectric construction enables application in power lines side by side with Energy
Cables
• Very light and easy to install
• Special High Density Black PE provides excellent resistance during installation and
protection against external effects like tough weather conditions and UV Ray during
operation
• Generally preferred as Aerial backbone cable for Wide Area Telecom Networks
• Optional armored steel wire supported version:
MLT-SA-SJ -A (A-DF(SR)2YT)
Construction:
1. Outer Black special HDPE Sheath
2. High modulus Aramid Yarns
3. Optional Inner PE Sheath
4. Core Wrapping(s)
5. PBT tube
6. Core filling Compound
7. Optical fibers
8. Water Resistive Tube filling Compound
9. Non Metallic Central Strength Member
10. Ripcord
Technical Data
Optic Fiber Type: SM: 652-B, G 652-D, G 655
MM: 62,5/125 OM1, 50/125 OM2, 50/125 OM3
www.ramcro.it
SIMPLE PATCH CABLE (zipcord)
ZIPCORD Applications
• Indoor interconnected and Patch-cord installations. All dielectric non-metallic construction,
J-VH 1x1 LSZH
Construction:
1. Optical fiber
2. Tight buffered fibre of 900 µm diameter (Easy
to strip)
3. Non-metallic strenght members (Aramide or
glass yarn)
4. Flame Retardant Non-Corrosive/Low Smoke
Zero Halogen Outer Jacket
Technical Data
Number of Fibers: 1
Optic Fiber Type: ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656
(NZDS Fiber)
- IEC 60793
- IEC 60794
www.ramcro.it
DOUBLE PATCH CABLE (Dublex Zipcord)
Applications
zipcord
• Indoor interconnected and Patch-cord installations. All dielectric non-metallic construction,
dublex
J-VH 2x1 LSZH
hence no ground loop problems
Construction:
1. Optical fiber
2. Tight buffered fibre of 900 µm diameter (Easy
to strip)
3. Non-metallic strenght members (Aramide or
glass yarn)
4. Flame Retardant Non-Corrosive/Low Smoke
Zero Halogen Outer Jacket
Technical Data
Number of Fibers: 2
Optic Fiber Type: ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656
(NZDS Fiber)
- IEC 60793
- IEC 60794
www.ramcro.it
BREAKOUT CABLES INDOOR
Applications
breakout • Indoor and duct installations; Halogen Free Flame Retardant / Flame Retardant Non-Corrosive
J-V2H nx1 LSZH
cables
/ Low Smoke Zero Halogen design. All dielectric non-metallic construction, hence no ground loop
problems; Ready for direct connectorization in field; suitable for backbone and horizontal sub
systems such as FTTH and FTTD.
Construction:
1. Optical fiber
2. Tight buffered fibre of 900 µm diameter (Easy
to strip)
3. Non-metallic strenght members (Aramide or
glass yarn)
4. Flame Retardant Non-Corrosive/Low Smoke
Zero Halogen Outer Jacket
Technical Data
Number of Fibers: 2-12
Optic Fiber Type: ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656
(NZDS Fiber)
- IEC 60793
- IEC 60794
www.ramcro.it
BREAKOUT CABLES OUTDOOR
breakout
Applications
A-V2H(SR)2Y nx1
• Outdoor and duct installations; ready for direct connectorization in field; suitable for
cables
backbone and horizontal sub systems such as FTTH and FTTD.
Construction:
1. Optical fiber
2. Tight buffered fibre of 900 µm diameter (Easy
to strip)
3. Non-metallic strenght members (Aramide or
glass yarn)
4. Flame Retardant Non-Corrosive/Low Smoke
Zero Halogen Outer Jacket
5. Corrugated Steel Tape armored
6. Outer Black PE Sheath
Technical Data
Number of Fibers: 2-12
Optic Fiber Type: ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656
(NZDS Fiber)
- IEC 60793
- IEC 60794
www.ramcro.it
AERIAL TYPE BREAKOUT CABLES WITH
MESSENGER
aerial type
breakout
Applications
A-V2H(SR)T2Y nx1
• Outdoor and Aerial installations; ready for direct connectorization in field; suitable for
backbone and horizontal sub systems such as FTTH and FTTD.
Construction:
1. Optical fiber
2. Tight buffered fibre of 900 µm diameter (Easy
to strip)
3. Non-metallic strenght members (Aramide or
glass yarn)
4. Flame Retardant Non-Corrosive/Low Smoke
Zero Halogen Outer Jacket
5. Corrugated Steel Tape armored
6. Outer Black PE Sheath
7. Supporting Steel Wire
Technical Data
Number of Fibers: 2-12
Optic Fiber Type: ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T g.655 & G.656
(NZDS Fiber)
- IEC 60793
- IEC 60794
www.ramcro.it
PROJECT
COUNTRY PROJECT CONTRACTOR TYPE OF CABLE
POLSKIE LNG REGASIFICATION TERMI-
POLAND NAL PROJECT SIRTI FIBER HYBRID CABLE
SWEET CONDENSATE STABILIZER UNIT
LIST
PROJECT – AT MARSA EL BREGA GAS
LYBIA PLANT SIRTE OIL COMPANY FIBER HYBRID CABLE
DUBAI NATIONAL PETROLEUM CONST. CO NPCC & ADCO FIBER OPTICAL CABLES
17
www.ramcro.it
RAMCRO
18
www.ramcro.it