YDY 450/750

Building wires

Standard: PN-E-90068

Design

1. Copper conductor - round, solid class 1


2. PVC insulation
3. PVC outer sheath

Application

Cables are designed for fixed installation, indoors, in air, in and under plaster.
Installation of the product should only be carried out by personnel trained and qualified for electrical works. The product is
designed according to recognized standards. Applicable rules of installation must be applied at all times.

Properties

Rated voltage Uo/U 0,45/0,75 kV Self-extinguishing of one cable IEC 60332-1-2


Test voltage 2,5 (AC) kV CPR-Classification Eca
Maximal short-circuit conductor 160 °C UV stability no
temperature
Packaging drum, coil
Maximal operating conductor 70 °C
Certificate BBJ
temperature
RoHS yes
Temperature range from -30 up to 70 °C
REACH yes
Minimal temperature for laying 5 °C
and manipulation Declaration of Conformity EU yes
(CE)
Minimal storage temperature -30 °C
Colour of insulation HD 308 S2
Colour of sheath white

CTL00218 rev. 1
Page 1 of 2
YDY 450/750

Technical data

No. of cores and Diameter of Thickness - Thickness - Diameter Weight Minimal radius Max. effective Maximum
cross-section conductor nominal nominal sheath informative informative of bend resistance pulling force *1
insulation conductor at 20°C
mm² mm mm mm mm kg/km mm Ω/km N

2x1 1,1 0,8 1,2 7,6 83 31 18,1 100

2x1,5 1,3 0,8 1,2 8,1 99 32 12,1 150

2x2,5 1,7 0,8 1,2 8,9 127 36 7,41 250

2x10 3,5 1,1 1,3 13,8 363 55 1,83 1000

3x1 1,1 0,8 1,2 8,0 148 32 18,1 150

3x1,5 1,3 0,8 1,2 8,7 127 35 12,1 225

3x2,5 1,7 0,8 1,2 9,6 166 38 7,41 375

3x4 2,2 0,9 1,2 10,8 219 43 4,61 600

3x6 2,7 0,9 1,3 12,0 294 48 3,08 900

3x10 3,5 1,1 1,3 14,6 459 58 1,83 1500

4x1 1,1 0,8 1,2 8,7 119 35 18,1 200

4x1,5 1,3 0,8 1,2 9,3 144 37 12,1 300

4x2,5 1,7 0,8 1,2 10,2 192 41 7,41 500

4x4 2,2 0,9 1,3 12,4 296 50 4,61 800

4x6 2,7 0,9 1,3 13,6 389 54 3,08 1200

4x10 3,5 1,1 1,3 16,7 618 67 1,83 2000

5x1 1,1 0,8 1,2 9,5 144 38 18,1 250

5x1,5 1,3 0,8 1,2 10,5 183 42 12,1 375

5x2,5 1,7 0,8 1,2 11,2 239 45 7,41 625

5x4 2,2 0,9 1,3 13,6 360 54 4,61 1000

5x6 2,7 0,9 1,3 14,9 476 59 3,08 1500

5x10 3,5 1,1 1,3 17,7 725 71 1,83 2500

*1 Force is distributed over all cable conductors; Force for the pulling head or conductor grip

This data was prepared with due diligence and in good faith for informational purposes only and does not contain any representations, legally binding declarations or guarantees unless
otherwise agreed in writing by NKT. NKT® is a registered trademark of NKT. © The copyright of this document is vested in NKT. All rights reserved at the time of issuance.
CTL00218 rev. 1