System302 Components
2008 - 2010 Copyright Smar
System302 Architecture
System302 Architecture
Distributed Architecture
Horizontal Comunication
4-20 mA
MODBUS
System302 DFI302
A Multi Protocol Controller Totally Redundant!
System302 Processor DF62 Processor Handles:
256 Conventional Points 4 FF H1 Networks (Up to 64 Foundation Fieldbus Field Devices) 4 LAS
1 FF HSE Port
1 Modbus Gateway Network 100 Fieldbus Foundation Function Blocks Ladder Logic FFB (1024 I/O) Embedded Web Server High Memory for Data Logger
MODBUS
DF62 Redundancy
LAS Redundancy Interface Redundancy Controller Redundancy Two ways communication to the field Two ways communication to the control room
System302 Processor DF63 Processor Handles:
MODBUS
256 Conventional Points 4 FF H1 Networks (Up to 64 Foundation Fieldbus Field Devices) 4 LAS 2 FF HSE Port 1 Modbus Gateway Network 100 Fieldbus Foundation Function Blocks Ladder Logic with LogicView
Embedded Web Server
DF63 Redundancy
LAS Redundancy Interface Redundancy Controller Redundancy Media Redundancy Two communication ways to the field
Two ways communication to the control room
System302 Processor
DF73 Processor Handles:
MODBUS
256 Conventional Points 1 Profibus DP Network 2 FF HSE Port
1 Modbus Gateway Network
100 Fieldbus Foundation Function Blocks Ladder IEC611151-3 Embedded Web Server
System302 Processor
DF75 Processor Handles:
1024 Discrete Points 512 Analogue Points 1 Modbus Port TCP/IP
2 FF HSE Ports
1 Modbus 232 Port Ladder IEC 61151-3 Functional Blocks
System302 Processor
DF79 Processor Handles:
MODBUS
256 Conventional Points 1 DeviceNet Network 2 FF HSE Port 1 Modbus Gateway Network 100 Fieldbus Foundation Function Blocks
Ladder IEC611151-3
Embedded Web Server
System302 Processor
DF81 Processor Handles:
MODBUS
256 Conventional Points 1 ASi Network 2 FF HSE Port 1 Modbus Gateway Network 100 Fieldbus Foundation Function Blocks
Ladder IEC61151-3 Embedded Web Server
DF73, DF75, DF79 & DF81 Redundancy
Interface Redundancy Controller Redundancy High Memory for Data Logger
DF95
This CPU do not need Coupler ou gateway DP/PA.
2 ETH ports 1 Serial port 2 Profibus PA port 1 Profibus DP port DF95
DF97
This CPU do not need Coupler ou gateway DP/PA.
2 ETH ports 1 Serial port 4 Profibus PA ports 1 Profibus DP port
DF97
Arquitecture with DF95/97 (only PA communication)
HSE -Eth1 HSE-Eth2
DF73
DF97
IMB I/O
IMB I/O
Profibus DP
Remote I/O
Drivers
Profibus DP/DP Coupler Profibus DP Profibus PA x 4
Arquitecture with DF95/97 (PA and DPcommunication)
HSE -Eth1 HSE-Eth2
DF95/97
IMB I/O
Profibus DP
Remote I/O
Drivers
Profibus DP/DP Coupler Profibus DP Profibus PA x 4
System302 Architecture
System302 Architecture Field Devices
What we have!
4-20 mA
What we can integrate!
MODBUS
Field Devices Accessories for Pressure Transmitter
21
Field Devices
Fieldbus Converters
IF302 / IF303 Three current inputs
4-20 mA, 0-20 mA
FI302 / FI303 Three current outputs
4-20 mA Fail-safe modes
FP302 -FF to Pressure Converter FP303 - Profibus to Pressure Converter
3 - 15 PSI Fail-safe modes
22
Field Accessories
Stand alone operation with high reliability.
LAS (Link Active Scheduler)
DFI302 Distributed Field Interface
Bridge
Gateway capability (H1 to Ethernet or HSE). Advanced process control ( complex function blocks). Digital / Analog IO. Modular concept unlimited expandability.
23
DFI302 - I/O Modules List
DFI302 - I/O Modules List
DFI302 - I/O Modules List
DFI302 - I/O Modules List
Field Accessories HI302
The HI302 is a hardware component integral to System 302 which main function is to interface HART devices to Foundation Fieldbus Systems, allowing the user to perform maintenance, calibration, sensor status monitoring, device status, among others information.
Field Accessories HI302
HI302 (Hart to FF H1):
8 Hart channels Up to 4 Devices Per Channel