Fast Ethernet
and
Gigabit Ethernet
Networks: Fast Ethernet
Fast Ethernet (100BASE-T)
How to achieve 100 Mbps capacity?
LLC
MAC
Data Link
Layer
Convergence Sublayer
MII
Media Independent Interface
Physical
Layer
Media Dependent Sublayer
Media Independent Interface provides three choices.
Networks: Fast Ethernet
Fast Ethernet [IEEE 802.3u]
Three Choices
Figure 4-21.The original fast Ethernet cabling.
* Concept facilitated by 10Mbps/100Mbps Adapter Cards
Networks: Fast Ethernet
100 BASE T
Networks: Fast Ethernet
Fast Ethernet Details
UTP Cable has a 30 MHz limit
Not feasible to use clock encoding (i.e., NO
Manchester encoding)
Instead use bit encoding schemes with
sufficient transitions for receiver to
maintain clock synchronization.
Networks: Fast Ethernet
100 BASE T4
Can use four separate twisted pairs of Cat 3 UTP
Utilize three pair in both directions (at 33 1/3
Mbps) with other pair for carrier sense/collision
detection.
Three-level ternary code is used 8B/6T.
Prior to transmission each set of 8 bits is
converted into 6 ternary symbols.
Networks: Fast Ethernet
100 BASE T4
The signaling rate becomes
100 x 6/8
------------ = 25 MHz
3
Three signal levels : +V, 0, -V
Codewords are selected such that line is d.c. balanced.
All codewords have a combined weight of 0 or 1.
Networks: Fast Ethernet
100 BASE T4
36 = 729 possible codewords.
Only 256 codewords are requires, hence they are
selected:
To achieve d.c. balance
Assuming all codewords have at least two signal
transitions within them (for receiver clock
synchronization).
To solve d.c. wander, whenever a string of
codewords with +1 are sent, alternate codewords
(inverted before transmission) are used.
To reduce latency, ternary symbols are sent
staggered on the three lines.
Networks: Fast Ethernet
100 BASE T4
Ethernet Interframe gap of 9.6
microseconds becomes 960 nanoseconds in
Fast Ethernet.
100 m. max distance to hub; 200 meters
between stations.
Maximum of two Class II repeaters.
Networks: Fast Ethernet
100 Base TX
Uses two pair of twisted pair, one pair for
transmission and one pair for reception.
Uses either STP or Cat 5 UTP.
Uses MTL-3 signaling scheme that involves
three voltages.
Uses 4B/5B encoding.
There is a guaranteed signal transition at
least every two bits.
Networks: Fast Ethernet
10
100 BASE FX
Uses two optical fibers, one for
transmission and one for reception.
Uses FDDI technology of converting 4B/5B
to NRZI code group streams into optical
signals.
Networks: Fast Ethernet
11
Fast Ethernet Repeaters
and Switches
Class I Repeater supports unlike physical media
segments (only one per collision domain)
Class II Repeater limited to single physical media
type (there may be two repeaters per collision
domain)
Switches to improve performance can add fullduplex and have autonegotiation for speed
mismatches.
Networks: Fast Ethernet
12
Collision Domains
Networks: Fast Ethernet
13
Networks: Fast Ethernet
14
Networks: Fast Ethernet
15
Gigabit Ethernet History
In February 1997 the Gigabit Ethernet Alliance
announced that IEEE802.3z Task Force met to review
the first draft of the Gigabit Ethernet Standard
According to IDC by the end of 1997 85% of all
network connections used Ethernet.
Higher capacity Ethernet was appealing because
network managers can leverage their investment in staff
skills and training.
1000 BASE X (IEEE802.3z) was ratified in June 1998.
Networks: Fast Ethernet
16
Gigabit Ethernet (1000 BASE X)
Provides speeds of 1000 Mbps (i.e., one billion bits per
second capacity) for half-duplex and full-duplex
operation.
Uses Ethernet frame format and MAC technology
CSMA/CD access method with support for one repeater per
collision domain.
Backward compatible with 10 BASE-T and 100 BASE-T.
Uses 802.3 full-duplex Ethernet technology.
Uses 802.3x flow control.
All Gigabit Ethernet configurations are point-topoint!
Networks: Fast Ethernet
17
Gigabit Ethernet Architecture Standard
Media Access Control (MAC)
full duplex and/or half duplex
Gigabit Media Independent Interface (GMII)
(optional)
1000 Base X PHY
8B/10B auto-negotiation
1000 Base-LX
1000 Base T
PCS
1000 Base-SX 1000 Base-CX
Fiber optic
transceiver
Fiber optic
transceiver
Copper
transceiver
Single Mode or
Multimode Fiber
Multimode
Fiber
Shieled
Copper Cable
1000 Base T
PMA
transceiver
Unshielded twisted pair
IEEE 802.3ab
IEEE 802.3z
Networks: Fast Ethernet
Source - IEEE
18
Gigabit Ethernet Technology
Figure 4-23.Gigabit Ethernet cabling.
1000 BASE SX
fiber - short wavelength
1000 BASE LX
fiber - long wavelength
1000 BASE CX
copper - shielded twisted pair
1000 BASE T
copper - unshielded twisted pair
* Based on Fiber Channel physical signaling technology.
Networks: Fast Ethernet
19
Gigabit Ethernet (1000 BASE-T)
LLC
MAC
GMII
Data Link
Layer
Gigabit Media Independent Interface
Physical Layer
Media Dependent Interface
Medium
Networks: Fast Ethernet
20
Gigabit Media Independent
Interface (GMII)
Allows any physical layer to be used with a
given MAC.
Namely, Fiber Channel physical layer can
be used with CSMA/CD.
Permits both full-duplex and half-duplex.
Networks: Fast Ethernet
21
1000 BASE SX
Short wavelength
Supports duplex links up to 275 meters.
770-860 nm range; 850 nm laser wavelength
(FC) Fiber Channel technology
PCS (Physical Code Sublayer) includes
8B/10B encoding with 1.25 Gbps line.
Only multimode fiber
Cheaper than LX.
Networks: Fast Ethernet
22
8B/10B Encoder
Networks: Fast Ethernet
23
8B/10B Encoding Issues
When the encoder has a choice for codewords, it always
chooses the codeword that moves in the direction of
balancing the number of 0s and 1s. This keeps the DC
component of the signal as low as possible.
Networks: Fast Ethernet
24
1000 BASE LX
Long wavelength
Supports duplex links up to 550 meters.
1270-1355 nm range; 1300 nm wavelength
using lasers.
Fiber Channel technology
PCS (Physical Code Sublayer) includes
8B/10B encoding with 1.25 Gbps line.
Either single mode or multimode fiber.
Networks: Fast Ethernet
25
1000 BASE CX
Short haul copper jumpers
Shielded twisted pair.
25 meters or less typically within wiring
closet.
PCS (Physical Code Sublayer) includes
8B/10B encoding with 1.25 Gbps line.
Each link is composed of a separate
shielded twisted pair running in each
direction.
Networks: Fast Ethernet
26
1000 BASE T
Twisted Pair
Four pairs of Category 5 UTP.
IEEE 802.3ab ratified in June 1999.
Category 5, 6 and 7 copper up to 100 meters.
This requires extensive signal processing.
Networks: Fast Ethernet
27
Gigabit Ethernet compared
to Fiber Channel
Since Fiber Channel (FC) already existed,
the idea was to immediately leverage physical
layer of FC into Gigabit Ethernet.
The difference is that fiber channel was
viewed as specialized for high-speed I/O
lines. Gigabit Ethernet is general purpose
and can be used as a high-capacity switch.
Networks: Fast Ethernet
28
Gigabit Ethernet
Viewed as LAN solution while ATM is WAN
solution.
Gigabit Ethernet can be shared (hub) or switched.
Shared Hub
Half duplex: CSMA/CD with MAC changes:
Carrier Extension
Frame Bursting
Switch
Full duplex: Buffered repeater called {Buffered
Distributor}
Networks: Fast Ethernet
29
Gigabit Ethernet
Figure 4-22. (a) A two-station Ethernet. (b) A multistation Ethernet.
Networks: Fast Ethernet
30
Carrier Extension
Frame
RRRRRRRRRRRRR
Carrier Extension
512 bytes
For 10BaseT : 2.5 km max; slot time = 64 bytes
For 1000BaseT: 200 m max; slot time = 512 bytes
Carrier Extension :: continue transmitting control
This permits minimum 64-byte frame to be handled.
Control characters discarded at destination.
For small frames, LAN throughput is only slightly
better than Fast Ethernet.
Networks: Fast Ethernet
31
Based on Raj Jains slide
Frame Bursting
Frame Extension
Frame
Frame
Frame
512 bytes
Frame burst
Source sends out burst of frames without relinquishing
control of the network.
Uses Ethernet Interframe gap filled with extension bits
(96 bits)
Maximum frame burst is 8192 bytes
Three times more throughput for small frames.
Networks: Fast Ethernet
32
Based on Raj Jains slide
Buffered Distributor
Hub
A buffered distributor is a new type of 802.3 hub
where incoming frames are buffered in FIFO queues.
Each port has an input FIFO queue and an output FIFO queue.
A frame arriving at an input queue is forwarded to all output queues,
except the one on the incoming port.
CSMA/CD arbitration is done inside the distributor
to forward the frames to the output FIFOs.
Based on
Raj Jain slide and
Vijay Moorthy discussion
Networks: Fast Ethernet
33
Buffered Distributor
Hub
Since collisions can no longer occur external to the
distributor on the links, the distance restrictions no
longer apply.
Since the sender can flood an input FIFO, 802.3x
frame-based flow control is used to handle congestion
between the sending station and the input port.
Based on
All links are full-duplex.
Raj Jain slide and
Vijay Moorthy discussion
Networks: Fast Ethernet
34
Buffered Distributor
White Paper
By
McIntyre and Arora
Networks: Fast Ethernet
35