1
MEMBRANE
TECHNOLOGY
1. MEMBRANE RO
2. SYSTEM DESIGN
3. SYSTEM MANAGEMENT
4. TROUBLESHOOTING
MEMBRANE RO
OSMOTIC PROCESSES
Concentrated
Solution
Pure
Water
OSMOTIC PROCESSES
Concentrated
Solution
Osmosis
Pure
Water
OSMOTIC PROCESSES
Concentrated
Solution
Purified
Water
OSMOTIC PROCESSES
Pressure
Concentrated
Solution
Purified
Water
Reverse Osmosis
REVERSE OSMOSIS PERFORMANCE
REVERSE OSMOSIS PERFORMANCE
Feed
REVERSE OSMOSIS PERFORMANCE
Feed
Permeate
REVERSE OSMOSIS PERFORMANCE
Feed
Permeate
Reject
(Brine)
WATER RECOVERY
SOLUTE REJECTION
Water Recovery =
Permeate Flow
Water Recovery =
x 100%
Feedwater Flow
REVERSE OSMOSIS PERFORMANCE
Feed
Permeate
Reject
(Brine)
REVERSE OSMOSIS PERFORMANCE
75% Recovery
Feed
Permeate
100 m3/hr
75 m3/hr
25 m3/hr
Reject
(Brine)
Rejection =
Rejection =
CF - C P
CF
x 100%
SALT PASSAGE
% Salt Passage = 100 - % Rejection
90% Rejection = 10% Salt Passage
Water Contaminants
Class
Typical Example
Suspended solids
Dirt, clay, colloidal materials
Dissolved organics
Trihalomethanes, synthetic organic
chemicals, humic acids, fulvic acids
Dissolved ionics (salts)
Heavy metals, silica, arsenic,
nitrate
Microorganisms
Bacteria, viruses, protozoan cysts,
fungi, algae
Gases
Hydrogen sulfide, methane, radon
Filtration Range
MEMBRANE TECHNOLOGIES
APPLICATION
Particle Size
Yeast Cell = 3.00
microns
Bacteria = 0.45
microns
Ferric Iron
Molecule = 0.001
microns
Human Hair ~ 75
microns
REVERSE OSMOSIS PERFORMANCE
75% Recovery
Feed
Permeate
100 m3/hr
75 m3/hr
Reject
25 m3/hr
REVERSE OSMOSIS PERFORMANCE
75% Recovery
90% Rejection
Feed
Permeate
100 m3/hr
75 m3/hr
Reject
25 m3/hr
REVERSE OSMOSIS PERFORMANCE
75% Recovery
90% Rejection
Feed
Permeate
100 m3/hr
75 m3/hr
100 mg/L Ca
10 mg/L Ca
Reject
25 m3/hr
370 mg/L Ca
REVERSE OSMOSIS PERFORMANCE
75% Recovery
90% Rejection
Feed
Permeate
100 m3/hr
75 m3/hr
100 mg/L Ca
10 mg/L Ca
Concentration
Factor
Feed Flow
Reject Flow
Reject
25 m3/hr
370 mg/L Ca
REVERSE OSMOSIS PERFORMANCE
75% Recovery
90% Rejection
Feed
Permeate
100 m3/hr
75 m3/hr
100 mg/L Ca
10 mg/L Ca
Concentration
Factor
Feed Flow
Reject Flow
Reject
25 m3/hr
370 mg/L Ca
400 mg/L Ca
SEMI-PERMEABLE
MEMBRANE
SEMI-PERMEABLE
MEMBRANE
Water
SEMI-PERMEABLE
MEMBRANE
Macromolecules
Water
SEMI-PERMEABLE
MEMBRANE
Dissolved
Solids
Water
Macromolecules
MEMBRANE MATERIALS
Cellulose Acetate (CA)
Polyamide (PA)
CA MEMBRANE
Non-Porous Region
Micro-Porous Region
FEED
REJECT
REJECT
FEED
PERMEATE
CROSS-FLOW FILTRATION
REJECT
FEED
PERMEATE
PA MEMBRANE
Non-Porous Layer (Polyamide)
Micro-Porous Support Layer (Polysulfone)
PA MEMBRANE
REJECT
FEED
PERMEATE
PA MEMBRANE
REJECT
FEED
Intl
PERMEATE
RO MEMBRANE PERFORMANCE
RO MEMBRANE
PERFORMANCE
Solute
Sodium
Chloride
Calcium
Magnesium
Sulfate
Carbonate
Conductivity
Silica
GASES
CA Membrane
85 - 99
85 - 99
90 - 99+
90 - 99+
90 - 99+
90 - 99+
85 - 99
80 - 90
0
PA Membrane
96 - 99
96 - 99
98 - 99+
98 - 99+
98 - 99+
98 - 99+
97 - 99
98
0
COMPARATIVE PROPERTIES COMMERCIAL RO MEMBRANES
Property
CA Membrane
PA Membrane
Surface Charge
Neutral
Negative
Pressure
(300 - 600 psi )
21 - 42 kgm/cm2
(150 - 400 psi)
10.5 - 28 kgm/cm2
Temperature
35oC (95F)
45oC (113F)
pH (operating)
4-6
Chlorine, free
up to 1.0 mg/L
None
Typical Lifetime
2 - 3 years
2 - 5 years
Cost (per module)
3 - 11
1.5X
COMPARATIVE PROPERTIES COMMERCIAL RO MEMBRANES
CA Membrane
PA Membrane
ADVANTAGE
Forgiving
High Rejection
DISADVANTAGE
High Pressure
pH Sensitive
Chlorine Sensitive
Fouling Prone
TYPICAL USE
Surface Water
Ground Water
SPIRAL WOUND MODULE
Permeate Spacer
Membrane
Feed Spacer
Membrane
SPIRAL WOUND MODULE
Concentrate Out
Feed Flow
Concentrate Out
Feed in
Feed Flow
Feed in
Permeate Spacer
Membrane
Feed Spacer
Membrane
SPIRAL WOUND MODULE
Concentrate Out
Feed Flow
Permeate
Concentrate Out
Feed in
Feed Flow
Feed in
Permeate Spacer
Membrane
Feed Spacer
Membrane
HOLLOW FIBER MODULE
REJECT
FEED
PERMEATE
Comparisons of RO System Types
System Costs :
Spiral equal to hollow fiber
Flexibility in Design :
Spiral >> hollow fiber
Cleaning Behaviour :
Spiral > hollow fiber
System Space Requirements :
Spiral > hollow fiber
Susceptibility to Fouling :
hollow fiber >> spiral
Energy Requirement :
Hollow fiber > spiral
2
RO SYSTEM DESIGN
RO SYSTEM DESIGN
Module (Element): Contains Membrane
Tube:
Modules in Series (4 - 6)
Stage:
Set of Tubes in Parallel
Array:
Arrangement of tubes; # Tubes/Stage
Train:
Set of all of the Above
RO SYSTEM FLOW DIAGRAM
1st stage
4 tubes
2nd stage
2 tubes
RO SYSTEM FLOW DIAGRAM
1st stage
4 tubes
4 X 2 ARRAY
2nd stage
2 tubes
RO SYSTEM FLOW DIAGRAM
4 X 2 ARRAY
2 STAGES
1 TRAIN
RO SYSTEM FLOW DIAGRAM
FEED
1st stage
RO SYSTEM FLOW DIAGRAM
FEED
1st stage
2nd stage
RO SYSTEM FLOW DIAGRAM
PERMEATE
FEED
1st stage
2nd stage
RO SYSTEM FLOW DIAGRAM
PERMEATE
FEED
CONCENTRATE
1st stage
2nd stage
RO SYSTEM FLOW DIAGRAM
50% MAXIMUM RECOVERY per STAGE
PERMEATE
FEED
CONCENTRATE
1st stage
2nd stage
RO SYSTEM FLOW DIAGRAM
50% MAXIMUM RECOVERY per STAGE
75 m3/hr
50 m /hr
3
75% RECOVERY
PERMEATE
25 m3/hr
50
m3/hr
FEED
100 m3/hr
1st stage
2nd stage
CONCENTRATE
25 m3/hr
RO SYSTEM FLOW DIAGRAM
50% MAXIMUM RECOVERY per STAGE
90% REJECTION
75 m3/hr
50 m /hr
3
75% RECOVERY
PERMEATE
25 m3/hr
50
m3/hr
FEED
100 m3/hr
100 mg/L
CONCENTRATE
1st stage
2nd stage
RO SYSTEM FLOW DIAGRAM
50% MAXIMUM RECOVERY per STAGE
90% REJECTION
50 m /hr
75 m3/hr
10 mg/L
13 mg/L
75% RECOVERY
PERMEATE
25 m3/hr
19mg/L
50
m3/hr
FEED
100 m3/hr
100 mg/L
190 mg/L
1st stage
2nd stage
CONCENTRATE
25 m3/hr
361 mg/L
3
MEMBRANE SYSTEM
MANAGEMENT
Pretreatment
Monitoring
PRETREATMENT
PREVENT
SUSPENDED SOLIDS FOULING
ORGANIC / MB FOULING
DISSOLVED SOLIDS SCALE FORMATION
MEMBRANE DEGRADATION
Membrane Productivity as a
Function of Operating Time
Product
Flow
Rate
Operating Time
Properly Pretreated Feed
Membrane Productivity as a
Function of Operating Time
Product
Flow
Rate
Operating Time
Properly Pretreated Feed
Marginal Pretreatment, Periodic Cleaning
Membrane Productivity as a
Function of Operating Time
Product
Flow
Rate
Operating Time
Properly Pretreated Feed
Marginal Pretreatment, Periodic Cleaning
Inadequate Pretreatment, Frequent Cleaning
RO MEMBRANE FEEDWATER
QUALITY REQUIREMENTS
ITEM
Suspended
Solids
PARAMETER
VALUE
SDI
<5
Turbidity
< 1 NTU
Iron
<0.05 mg/L
Manganese
< 0.5 mg/L
____________________________________________________
Organics
TOC
10 -15 mg/L
____________________________________________________
Dissolved
Solids
* In Concentrate
LSI
Barium
Strontium
<1*
< 0.05 mg/L
<0.1 mg/L
SDI = Silt Density Index
The Standard Test Method has been described in ASTM Test D 4189-82
Calculation :
SDI = [ 1 to / t1 ] * 100 / 15
to = measured initial time, necessary to filter 500 ml of sample water
t1 = measured time, after 15 minutes feed pressure to be kept constant,
necessary to filter 500 ml sample water
t1 is four times as long as to SDI = 5
A water sample that totally blocks the membrane filter has an SDI = 6.7
Influent Iron Limits
Oxygen
(ppm)
pH
<0.50
<6.00
0.50-5.00
5.00-10.00
Maximum
Iron Level
(ppm)
4.00
6.00-7.00 0.50
>7.00
0.05
RO MEMBRANE - SPECIFIC
FEEDWATER QUALITY
REQUIREMENTS
PARAMETER
CA membrane
PA membrane
Chlorine, free, mg/L
<1.0
pH
4-6
3 - 11
Temperature
35C (95F)
45C (113F)
RO PRETREATMENT TECHNIQUES
PARAMETER
SDI, Turbidity
Iron, Manganese
PRETREATMENT
Clarification, Filtration, Filter Aids
Oxidation (KMnO4, H2O2, Cl2)
Aeration, pH, Greensand Filtration
___________________________________________________
Organics
Cl2, Nanofiltration, Activated Carbon
MB
Cl2, Biocides, Filtration
___________________________________________________
Hardness, Barium
Strontium
Softening, Sequestrants, pH
Reactive Silica
Lime Softening
___________________________________________________
Free Chlorine
Sodium Metabisulfite
SYSTEM MONITORING
Data Collection
Normalization
Routine Cleaning
DATA COLLECTION
Temperature
SDI
pH
LSI
Pressure
Chlorine, Free
Flow Rate
Turbidity
TDS
MB Plate Counts
Data Collection
Inter
Inlet
Stage
Pressure
X
Flow Rate X
Conductivity
Temperature
pH
X
SDI X
Cl2, free
X
X
X
X
X
Turbidity
MB Plates
X
X
X
X
Brine
X
X
X
X
X
X
X
Permeate
X
X
X
RAW DATA
TIME
RAW DATA
PRODUCT FLOW
TIME
INCREASED FEED PRESSURE
RAW DATA
PRODUCT FLOW
TIME
INCREASED FEED PRESSURE
RAW DATA
Cooler Water Temp.
Higher Feed Conc.
PRODUCT FLOW
TIME
INCREASED FEED PRESSURE
RAW DATA
Cooler Water Temp.
Higher Feed Conc.
Fouling / Scaling
PRODUCT FLOW
TIME
NORMALIZED DATA
RAW DATA
INCREASED FEED PRESSURE
Cooler Water Temp.
Higher Feed Conc.
Fouling / Scaling
PRODUCT FLOW
NORMALIZED FLOW
TIME
NORMALIZED DATA
RAW DATA
INCREASED FEED PRESSURE
Cooler Water Temp.
Higher Feed Conc.
Fouling / Scaling
PRODUCT FLOW
NORMALIZED FLOW
SALT PASSAGE
TIME
4
TROUBLESHOOTING
TROUBLESHOOTING
Mechanical Problems
Performance Problems
Water Analysis
Profile/Probe
Autopsy
WATER ANALYSIS
Cations - Ba, Sr
Anions
Alkalinity
SiO2
Fe
TOC
MB
Temperature
pH
Water Source
RO Troubleshooting Guide
Problem
Product Flow
Salt Passage
Pressure Drop
Location
Scaling
Decreased
Increased
Increased
Last Stage
MB
Decreased
Normal/
Increased
Normal/
Increased
Any Stage
Colloidal
Decreased
Normal/
Increased
Normal/
Increased
First Stage
Degeneration
Increased
Increased
Decreased
First Stage
Abrasion
Increased
Increased
Decreased
First Stage
PROFILE / PROBE
Profiling
Conductivity of Permeate Measured at the End of Individual Tubes:
First Stage - Rows 2 & 3
Second Stage - Row 1
A
1
2
3
Profiling
Conductivity of Permeate Measured at the End of Individual Tubes:
First Stage - Rows 2 & 3
Second Stage - Row 1
A
1
2
15
18
16
150
16
12
14
13
14
12
15
95
14
13
12
Probing
Tube Identified by Profiling as High Conductivity Tube
Conductivity
Probing
15
16
111
105
98
Tube Identified by Profiling as High Conductivity Tube
Conductivity
AUTOPSY
Destructive Analysis of Membrane
Identification of Foulants and Scaling Agents
Identification of Microbiological Activity
Tools Used for Autopsy
MB Count
Photomicroscopy
APPLICATIONS OF REVERSE
OSMOSIS
Boiler Feedwater
Process Water
Potable Water
Ultrapure Water
Cooling Tower Blowdown
Water Reuse / Zero Discharge
When to Consider RO
DEMINERALIZED WATER SYSTEMS
High Cost Acid or Caustic
Regenerant Discharge Restrictions
Water with TDS greater than 150 mg/L
Treatment
Cost
Economics of Reverse Osmosis
and Ion Exchange
50
100
150
200
Feedwater TDS (mg/L as CaCO3 )
250
300
Economics of Reverse Osmosis
and Ion Exchange
Reverse Osmosis
Treatment
Cost
Ion Exchange
50
100
150
200
Feedwater TDS (mg/L as CaCO3 )
250
300
Economics of Reverse Osmosis
and Ion Exchange
Reverse Osmosis
Treatment
Cost
Ion Exchange
50
100
150
200
Feedwater TDS (mg/L as CaCO3 )
250
300
Questions & Answers !
- ???
Thank You !
Wish those will be useful to you !