0% found this document useful (0 votes)
117 views16 pages

Ricapito-1 PbLi-T Database

The document discusses the status of knowledge regarding the PbLi/T database. It outlines topics such as the solubility and Sieverts' constant of tritium in PbLi, the bulk diffusivity of hydrogen isotopes in PbLi, mass transfer between PbLi and gas, helium in PbLi, and possible future developments. Graphs and data from various studies are presented showing differences in measured values of quantities like the Sieverts' constant and diffusion coefficient, highlighting remaining uncertainties.

Uploaded by

Sasa Djordjevic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views16 pages

Ricapito-1 PbLi-T Database

The document discusses the status of knowledge regarding the PbLi/T database. It outlines topics such as the solubility and Sieverts' constant of tritium in PbLi, the bulk diffusivity of hydrogen isotopes in PbLi, mass transfer between PbLi and gas, helium in PbLi, and possible future developments. Graphs and data from various studies are presented showing differences in measured values of quantities like the Sieverts' constant and diffusion coefficient, highlighting remaining uncertainties.

Uploaded by

Sasa Djordjevic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 16

PbLi/T database:

status of the knowledge

I. Ricapito, ENEA CR Brasimone, FPN-FISING

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
OUTLINE

- Solubility and Sieverts constant in PbLi

- Bulk diffusivity in PbLi

- Mass transfer PbLi-gas

- He in PbLi

- Possible developments

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant

The knowledge of the function linking the tritium concentration


solubilized in LLE with the corresponding tritium partial
pressure at equilibrium, CT=f(PT), is of basic importance for the
LLE breeder blanket concept because of the strong impact on:

tritium permeation rate from the blanket into HCS;

requested capacity of the Coolant Purification System for a


given value of allowed T partial pressure in HCS

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant
Impact of Sieverts constant on the tritium permeation rate for
PPCS-HCLL
700
REITER SOLE
650 TES= 80%
-2
PHT, max= 1.5x10 Pa
T permeation rate into HCS (g/d)

600
LM flow-rate= 615 kg/s
550

500

450

400

350 PRF=1
300

250

200

150

100 PRF=10

50

0
1,0E-03 6,0E-03 1,1E-02 1,6E-02 2,1E-02 2,6E-02 3,1E-02 3,6E-02 4,1E-02 4,6E-02

Sieverts's constant (mol m-3 Pa-0,5)

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant

Sieverts law validity range /1

No deviation from Sieversts


law (Reiter) Deviation from Sieverts law (Wu)

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant
Sieverts law validity range /2

From Polcaro (1983)

Absorbed hydrogen weight (sample weight = 172 mg) as a function of time of absorption
(in min.) is shown at various hydrogen pressures: 1. PH2=20.87 kPa. 2. PH2=30.80 kPa.
3. PH2=47.01 kPa. 4. PH2=53.30 kPa. 5. PH2=77.41 kPa. 6. PH2=86.63 kPa. 7.
PH2=100.11 kPa.
One can see that the 5 fold increase in pressure (from plot 1 to 7) gives rise to about 7
fold increase of solubility (reviewed by A. Pisarev).

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant

Different values of Sieverts constant from different


authors (and different techniques)

-5
Absorption 10
technique

-6
10

Aiello
-1/2

-7
10 Pierini et al
S, at.fr. Pa

Katsuta et al
-8 Wu Desorption
10 technique
Wu & Blair
Chan & Veleckis
-9 Fauvet & Sannier
10 Reiter
Feuerstein et al
-10
10
0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0
-1
1000/T, K

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Solubility and Sievertsconstant

Sieverts constant: last results from SOLE campaign (2005),


absorption technique
T (C)
350 400 450 500 550 600 650
-1
10

Literature data (absorption technique)


Ks (mol m Pa )
-1/2

-2
10
-3

This experiment
Linear fit of experimental data
_._._. Reiter data

-3
10

1,6 1,5 1,4 1,3 1,2 1,1


-1
1000/T (K )

12844

K s 0,237 e RT
mol m-3 Pa-0.5 SOLE (A. Aiello)

1350

K s 1,310 e RT mol m-3 Pa-0.5 (Reiter)

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Bulk Diffusivity
Typical H2 pressure rise P(t) after saturation of the sample from gas
phase and fast evacuation of the hydrogen atmosphere (desorption
technique)

From Reiter, 1991

Curve (a) is desorption from the sample, container and vacuum walls. Curve (b) is a control run
without the sample. Curve (c) is the difference giving desorption from the sample.

Parameters of the experiment: T=591K, P=1.01 105Pa, tL=72h, m=250 g

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Bulk Diffusivity

Diffusion coefficient of hydrogen isotopes in LLE vs temperature

Reiter, 1991

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Bulk Diffusivity
Comparison of the bulk diffusion coefficients obtained by Terai (1), Reiter (2),
Shibuya (3), Fauvet (4)

(1) D=2.5 10-7exp(-27000/RT) m2s-1

(2) D=4.03 10-8 exp(-19500/RT) m2s-1

(3) D=2.62 10-9 exp(-6630/RT) m2s-1

(4) D(450C)= 1.510-9 m2s-1

Terais values are the highest, probably


because determined in high hydrogen
partial pressure, with reduced residual
surface effects

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Mass transfer PbLi-gas
Hydrogen transfer from LLE to gas phase: mechanisms
related coefficients /1

CT,l CT* PT2,i PT2

liquid bulk liquid boundary gas boundary gas bulk


layer interface layer

JT ,l hl (cT ,l cT* )

JT , r kr cT*2 ka PT 2,i

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Mass transfer PbLi-gas
Hydrogen transfer from LLE to gas phase: mechanisms
related coefficients /2

mass transfer in the metal boundary layer hl


adsorption coefficient Ka 0.5
k
recombination coefficient Kr, with k S a
kr

Results from A. Viola* (1991)

T,K hl, m s-1 Kr, m4mol-1s-1 Ka, mol m-2Pa-1 s-1


723 6.51 10-5 2.14 10-4 2.31 10-10
673 5.74 10-5 2.04 10-4 2.17 10-10
633 5.12 10-5 3.45 10-4 3.61 10-10

*Results have been achieved assuming valid the D diffusivity and Sieverts constant values as
measured by Reiter

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Mass transfer PbLi-gas
Effective mass transfer coefficient: simplified description of the
tritium desorption from LLE into a gas phase: J=KD(Cbulk - Cinterface)

TERAIs experiments (1991) on Tritium release from Pb16Li and influence


of H2 partial pressure on it

PH= 1E3 Pa

KD[ms-1]=2.510-3 exp(-30.7kJmol-1/RT); T=600-1100K, PH2=1000 Pa

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
He in PbLi
Formation of He bubbles and tritium trapping could have an important
impact on the blanket operation

Henryconstant (from L. Sedano) Diffusivity (from L.Sedano)

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007
Possible developments
Uncertainty remains about the range of validity of the Sieverts law.
On the other hand, there isnt consensus on the Sieverts constant
values. Taking into account the big impact of such issues on the LLE
based blanket, there is the urgent need to find reliable and agreed data.
A new task is presently open in EU for a further experimental activity.
Anyway, an international collaborations should be of outstanding
importance in this field.

Reference Tritium diffusivity values in bulk LLE (Terai and Reiter) are
spread in less than one order of magnitude. A sensitivity analysis should
be done in order to evaluate the impact of the different diffusivity
values on the tritium permeation rate into HCS: need of modelling
implementation.

Only few data on T/LLE-gas mass transfer coefficients are available. A


new set of data should be extracted from TRIEX experimental
campaigns, planned in the next two years. To do it, the implementation
and validation of mathematical models in this ambit appears as a
priority.

Fusione, Tecnologie e Presidio Nucleare IEA Workshop on PbLi-T


Sezione Ingegneria Sperimentale Idaho Falls, 11-12/06/2007