ILS (Glide Path) - System Part Training Book

This document provides specifications and configuration details for a dual frequency navigation system. It is organized into two main parts: Part 1 describes the general specifications including operating frequencies, output power levels, modulation parameters, monitoring capabilities, power supply details, and how the subsystems are configured within equipment racks. Part 2 will cover the technical details, including explanations of each subsystem, a system block diagram, signal flow, and descriptions of test points and outputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
279 views25 pages

ILS (Glide Path) - System Part Training Book

This document provides specifications and configuration details for a dual frequency navigation system. It is organized into two main parts: Part 1 describes the general specifications including operating frequencies, output power levels, modulation parameters, monitoring capabilities, power supply details, and how the subsystems are configured within equipment racks. Part 2 will cover the technical details, including explanations of each subsystem, a system block diagram, signal flow, and descriptions of test points and outputs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 25

- Table of Contents -

PART. 1 GENERAL PART. 2 TECHNICAL

1. Specification 1-1 1. Unit Explanation 2-1

2. Composition 1-4 2. System Block Diagram 2-6

3. Configuration 1-5 3. Signal Flow 2-7

4. Test Point & Output 2-8


1. Specification

Type Dual Frequency System


Range 328.6 to 335.4MHz, 50kHz Spacing
Frequency
Stability ±0.001%
DDS Synthesizer Controlled Difference between Course and Clearance is 5~14K
For CSB Course Max 5W, Normal 3W (control step:100mW)
For SBO Course Max 200mW, Normal 60mW (control step:1mW)
Output Power For CSB Clearance Max 600mW, Normal 300mW (control step:1mW)
Harmonic radiation & Spurious 0.25㎼(-36dBm) Max.
Stability ±0.2dB(At the operating frequency)
Type DDS syn.
Frequency 90Hz(±1%), 150Hz(±1%)
Depth of modulation(90Hz/150Hz) 40%(for each tone)
Adjustable Range Full Range / 0.1% step
Modulator
Mod Stability ±0.1% at the operating system
SDM Stability ±0.8% at the operating system
DDM Stability ±0.2% at the operating system
Tolerance ±0.01% at the operating system

1-1
1. Specification

Operating Mode AND, OR (selectable)

System change Time 1sec Max. (refer to ICAO Annex 10 CAT Ⅲ-c)

Configuration of Monitor System Integral(BITE), Near Field and Far Field

DDM (COU:0±0.009DDM, Width:±0.025 at 0.175DDM)


SDM(±4% at 80%)
Monitoring MOD(±2% at 40%)
Frequency Difference
Monitoring ITEM
DC voltage and Main power
(hot & cool standby monitoring)
RF level(±20% at setting value)
Center Line Alarm
Displacement Sensitivity Alarm
Each Monitor Ant. Operation Alarm

Alarm Time Delay 0.5sec to 10sec, Adjustable step is 0.1sec.

-5dBm to -35dBm, In here output power is fixed by AGC circuit in MON


Receiver Dynamic Range
unit that It is processed by DSP device.

1-2
1. Specification

OS : Base on Windows XP
PC LMMS
CPU : Core 2 duo
(Desk Top)
RAM: 2G, HDD: 250GB or higher

OS : Base on Windows XP
Control Function PC RMMS
CPU : Core 2 duo
(Note Book)
RAM : 2G, HDD: 120GB or higher

GUI Program Base on Windows XP


Communication Line RS-232, RS-485, Ethernet, ADSL/SDSL
Input AC 110V to 220V±10%, 50Hz±5% single phase, SMPS type
Output Power 28V, DC
Max. handling current 40A Max
Type Dual redundant power(refer to system block diagram)

Power Supply Input DC +28V from AC/DC


Output Power +6V, ±15, +28V
Battery capacity 5 hour(When the full system turn on)
Battery type dry type and not need any maintenance
EMC/EMI Compliant to MIL Std-461C

1-3
2. Composition

GP system consists of 6 subsystems.,

UIS SCS SAS PSS ADS ANS


User Signal Signal Power Antenna Antenna
Interface Generation Modulation Supply Distribution Subsystem
Subsystem & Control & Amplifier Subsystem & Combine
Subsystem Subsystem Subsystem

CSP SYN MPA PSU ADU M-Array


ANT
RCMU AGU SPU PDU CMU (3EA)

RMU DETs

Interlock MON

LIU

1-4
3. Configuration : Rack

UIS
(user interface subsystem)

SCS
(signal generation & control
subsystem)

SAS
(signal modulation & amplifier
subsystem)

PSS
(power supply subsystem)

1-5
3. Configuration : UIS(user interface subsystem)

UIS
ANS

ADS SCS

PSS SAS

1-6
3. Configuration : SCS(signal generation & control subsystem)

ANS UIS

ADS SCS

PSS SAS

1-7
3. Configuration : SAS(signal modulation & amplifier subsystem)

ANS UIS

ADS SCS

PSS
SAS

1-8
3. Configuration : PSS(power supply subsystem) – Front Panel

ANS UIS

ADS SCS

SAS
PSS

1-9
3. Configuration : PSS(power supply subsystem) – Rear Panel

+28V +15V -15V +6V


COMM POWER 2 POWER 1 +28V +15V -15V +6V
1 4 1 4 1 4

2 3 2 3 2 3

INPUT 2 INPUT 1

1 1 +6V 1 1 +28V 1 1 +28V


GND GND GND GND 2 2 N.C 2 2 +6V 2 2 +6V GND GND GND GND
GND GND GND
3 3 +15V 3 3 +15V 3 3 +15V
4 4 -15V 4 4 -15V 4 4 -15V

DC 28+ GND +6V GND +15V GND -15V GND DC 28+ GND +6V GND +15V GND -15V GND

BATTERY BATTERY
DC+ GND DC+ GND
RS232 RS232
D-SUB D-SUB

V-Adj V-Adj

V-Adj V-Adj

AC INPUT AC INPUT
AC 110V/230V/, 50/60Hz AC 110V/230V/, 50/60Hz

AC L AC N FG AC L AC N FG

1-10
3. Configuration : ADS(antenna distribution & combine subsystem)

ANS UIS

ADS SCS

PSS SAS

1-11
3. Configuration : ANS(antenna subsystem)

ANS
UIS
Upper Antenna
ADS SCS

PSS SAS
Middle Antenna

Lower Antenna

1-12
1. Unit Explanation

Unit Explanation

• Control of ILS full system


• Control through interface of external, user and internal modules
CSP
• Control and supervision of output by AGU & SPU
• Management of each alarm and alert by MON & SIU

• RF signal generation and provide to MPA


SYN • Local signal generation and provide to CMU detector
• Provide of RF(COS, CLR) signal monitor port in rear panel

• Audio signal(90/150Hz) generation and provide to MPA


AGU
• Provide of audio signal(COS CSB/SBO, CLR CSB) monitor port in front panel

• Converting analog signal from each detector to digital signal


MON
• Digital signal analysis by FPGA and transmit to CSP

• LIU play a Hub for ethernet communication between modules


LIU
• All internal ethernet communication is connected through LIU

• Control and monitor of MPA through CSP


SPU
• Control factor are output and phase and monitor factor are phase, output, temperature and so on

2-1
1. Unit Explanation

Unit Explanation

• Provide of CL/CS/CLR RF test port


• Envelope detection of CL & CS signal
STBY DET
• Can set up same condition with ground by control of SBO gain and phase
• Inserted 100W term and directional coupler because of directly receive of MPA output

• Provide of COU CSB/SBO and CLR CSB test port


FWD DET • Envelope detect at DET diode after amplifying of signal from output divider port
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz/1020 signal detection

• Provide of COU CSB/SBO and CLR CSB test port


RVS DET • Envelope detect at DET diode after amplifying of signal from output directional coupler port
• Detect signal is sent to MON Board > A/D conversion > DC level detection

• Provide of CL, CS and CLR test port


CMU DET
• Detect signal is sent to MON Board

• Provide of NFM test port


NFM DET • Envelope detect at DET diode after amplifying of signal from near field monitor antenna
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz signal detection

2-2
1. Unit Explanation

Unit Explanation

• Amplifier after receive RF signal(from SYN) and audio signal(from AGU)


Fucntion
• Amplitude and phase locking

• CSB : receive 0dBm(from SNN)  amplify 37dBm(5W)


COS_RF
• SBO : receive 0dBm(from SYN)  amplify 23dBm(200mW)
MPA

CLR_RF • CSB : receive 0dBm(from SNN)  amplify 28dBm(600mW)

• CSB, SBO modulation signal generate after composite RF signal and audio signal
Modulation
• Control of gain and phase change

• Receiving of equipment signal and output to ANT


ADU • Input port : 3 port > COS CSB, COS SBO and CLR CSB
• Output port : 3port > Upper ANT, Middle ANT and Low ANT
ADS
• Receiving of ANT signal and output to equipment
CMU • Input port : 3port > Upper ANT, Middle ANT and Low ANT
• Output port : 3 port > CL, CS and CLR

2-3
1. Unit Explanation

ADU
(Antenna Distribution Unit)

Gain & Phase Relationship

2-4
1. Unit Explanation

CMU
(Combining & Monitoring Unit)

Adjustment Range

Phase
MIN Standard MAX
Error

Low & Upper


CL Adj. -1.5dB 0dB 1.5dB +/- 1°
Ant

CL & Middle
CS Adj. -2.5dB 0dB 2.5dB +/- 1°
Ant

Upper Ant
Clearance - - - -
Output

2-5
2. System Block Diagram

2-6
3. Signal Flow

2-7
4. Test Point & Output

2-8