0% found this document useful (0 votes)
139 views82 pages

LLZ Practice

This document provides specifications and configuration details for an LLZ radar system comprised of six subsystems: User Interface, Signal Generation and Control, Signal Modulation and Amplification, Power Supply, Antenna Distribution and Combining, and Antenna. It describes the components, layout, and functions of each subsystem and their interfaces. Tables provide detailed technical specifications for frequency, modulation, monitoring, alarms, power requirements and more. Diagrams and pictures illustrate the rack layout and front/rear configuration of the individual subsystems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views82 pages

LLZ Practice

This document provides specifications and configuration details for an LLZ radar system comprised of six subsystems: User Interface, Signal Generation and Control, Signal Modulation and Amplification, Power Supply, Antenna Distribution and Combining, and Antenna. It describes the components, layout, and functions of each subsystem and their interfaces. Tables provide detailed technical specifications for frequency, modulation, monitoring, alarms, power requirements and more. Diagrams and pictures illustrate the rack layout and front/rear configuration of the individual subsystems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 82

- Table of Contents -

PART. 1 GENERAL PART. 2 TECHNICAL PART. 3 GUI (management program)

1. Specification 1-1 1. Block Diagram 2-1 1. Log In 3-1


2. Composition 1-4 2. Signal Flow 2-2 2. Main Screen 3-2
3. Configuration 1-5 3. Test Point & Output 2-3 3. Icon 3-3
4. Unit Explanation 1-13 4. Ethernet Line Connection 2-15 4. Menu 3-18
5. IP Network Diagram 2-16

PART. 4 GROUND CHECK PART. 5 COMPETITIVE

1. Course Line 4-1 1. Comparison 5-1


2. Course Sector 4-2 2. Main Up-Grade 5-4
3. Course Shift alarm 4-3 3. Strong Point 5-7
4. Course width alarm 4-4
1. Specification

Type Two Frequency


Range 108 to 112MHz, 50KHz Spacing
Frequency
Stability ±0.001%
DDS Synthesizer Controlled Difference between Course and Clearance is 5~14K
For CSB Course Max 20W, Normal 15W (control step:100mW)
For SBO Course Max 400mW, Normal 80mw (control step:1mW)
For CSB Clearance Max 20W, Normal 7.5W (control step:100mW)
Output Power
For SBO Clearance Max 400mw, Normal 200mW (control step:1mW)
Harmonic radiation & Spurious 0.25㎼(-36dBm) Max.
Stability ±0.2dB(At the operating frequency)
Type DDS syn.
Frequency 90Hz(±1%), 150Hz(±1%)
Depth of modulation(90Hz/150Hz) 20%(for each tone)
Adjustable Range Full Range / 0.1% step
Modulator
Mod Stability ±0.1% at the operating system
SDM Stability ±0.25% at the operating system
DDM Stability ±0.1% at the operating system
Tolerance ±0.01% at the operating system

1-1
1. Specification

Frequency 1,020Hz±50Hz
Modulation Depth 15% Max. 10% Normal. Full range adjustable by CSP or LMMS, RMMS
Identification
Morse Code Comply international morse code.
Number of letter 5 letters Max.
Operating Mode AND, OR (selectable)
System change Time 1sec Max. (refer to ICAO Annex 10 CAT Ⅲ-c)
Configuration of Monitor System Integral(BITE), Near Field and Far Field

DDM (COU:0±0.009DDM, Width:±0.025 at 0.155DDM)


SDM(±4% at 40%) / MOD(±2% at 20%)
Frequency Difference
Identification(±2% at 8% MOD)
Monitoring Monitoring ITEM DC voltage and Main power
(hot & cool standby monitoring) RF level(±20% at setting value)
Center Line Alarm
Displacement Sensitivity Alarm
Each Monitor Ant. Operation Alarm
Cable Fault, Threshold(±5mV at 10mV, ±75mV at 150mV)

Alarm Time Delay 0.5sec to 10sec, Adjustable step is 0.1sec.


-5dBm to -35dBm, In here output power is fixed by AGC circuit in MON
Receiver Dynamic Range
unit that It is processed by DSP device.

1-2
1. Specification

OS : Base on Windows XP
PC LMMS
CPU : Core 2 duo
(Desk Top)
RAM: 2G, HDD: 250GB or higher

OS : Base on Windows XP
Control Function PC RMMS
CPU : Core 2 duo
(Note Book)
RAM : 2G, HDD: 120GB or higher

GUI Program Base on Windows XP


Communication Line RS-232, RS-485, Ethernet, ADSL/SDSL
Input AC 110V to 220V±10%, 50Hz±5% single phase, SMPS type
Output Power 28V, DC
Max. handling current 40A Max
Type Dual redundant power(refer to system block diagram)

Power Supply Input DC +28V from AC/DC


Output Power +6V, ±15, +28V
Battery capacity 5 hour(When the full system turn on)
Battery type dry type and not need any maintenance
EMC/EMI Compliant to MIL Std-461C

1-3
2. Composition

LLZ system consists of 6 subsystems.,

UIS SCS SAS PSS ADS ANS


User Signal Signal Power Antenna Antenna
Interface Generation Modulation Supply Distribution Subsystem
Subsystem & Control & Amplifier Subsystem & Combine
Subsystem Subsystem Subsystem

CSP SYN MPA PSU ADU


LPDA
(14/20/24EA)
RCMU AGU SPU PDU CMU

RMU DETs

Interlock MON

LIU

1-4
3. Configuration : Rack

UIS
(user interface subsystem)

SCS
(signal generation & control
subsystem)

SAS
(signal modulation & amplifier
subsystem)

PSS
(power supply subsystem)

1-5
3. Configuration : UIS(user interface subsystem)

UIS
ANS

ADS SCS

PSS SAS

1-6
3. Configuration : SCS(signal generation & control subsystem)

ANS UIS

ADS SCS

PSS SAS

1-7
3. Configuration : SAS(signal modulation & amplifier subsystem)

ANS UIS

ADS SCS

PSS
SAS

1-8
3. Configuration : PSS(power supply subsystem) – Front Panel

ANS UIS

ADS SCS

SAS
PSS

1-9
3. Configuration : PSS(power supply subsystem) – Rear Panel

+28V +15V -15V +6V


COMM POWER 2 POWER 1 +28V +15V -15V +6V
1 4 1 4 1 4

2 3 2 3 2 3

INPUT 2 INPUT 1

1 1 +6V 1 1 +28V 1 1 +28V


GND GND GND GND 2 2 N.C 2 2 +6V 2 2 +6V GND GND GND GND
GND GND GND
3 3 +15V 3 3 +15V 3 3 +15V
4 4 -15V 4 4 -15V 4 4 -15V

DC 28+ GND +6V GND +15V GND -15V GND DC 28+ GND +6V GND +15V GND -15V GND

BATTERY BATTERY
DC+ GND DC+ GND
RS232 RS232
D-SUB D-SUB

V-Adj V-Adj

V-Adj V-Adj

AC INPUT AC INPUT
AC 110V/230V/, 50/60Hz AC 110V/230V/, 50/60Hz

AC L AC N FG AC L AC N FG
3. Configuration : ADS(antenna distribution & combine subsystem)

ANS UIS

ADS SCS

PSS SAS

1-11
3. Configuration : ANS(antenna subsystem)

ANS
UIS

ADS SCS

PSS SAS

1-12
4. Unit Explanation

Unit Explanation

• Control of ILS full system


• Control through interface of external, user and internal modules
CSP
• Control and supervision of output by AGU & SPU
• Management of each alarm and alert by MON & SIU

• RF signal generation and provide to MPA


SYN • Local signal generation and provide to CMU detector
• Provide of RF(COS, CLR) signal monitor port in rear panel

• Audio signal(90/150Hz) generation and provide to MPA


AGU
• Provide of audio signal(COS CSB/SBO, CLR CSB/SBO) monitor port in front panel

• Converting analog signal from each detector to digital signal


MON
• Digital signal analysis by FPGA and transmit to CSP

• LIU play a Hub for ethernet communication between modules


LIU
• All internal ethernet communication is connected through LIU

• Control and monitor of MPA through CSP


SPU
• Control factor are output and phase and monitor factor are phase, output, temperature and so on

1-13
4. Unit Explanation

Unit Explanation

• Provide of CL/CS/CLR RF test port


• Envelope detection of CL & CS signal
STBY DET
• Can set up same condition with ground by control of SBO gain and phase
• Inserted 100W term and directional coupler because of directly receive of MPA output

• Provide of COU CSB/SBO and CLR CSB/SBO test port


FWD DET • Envelope detect at DET diode after amplifying of signal from output divider port
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz/1020 signal detection

• Provide of COU CSB/SBO and CLR CSB/SBO test port


RVS DET • Envelope detect at DET diode after amplifying of signal from output directional coupler port
• Detect signal is sent to MON Board > A/D conversion > DC level detection

• Provide of CL, CS and CLR test port


CMU DET
• Detect signal is sent to MON Board

• Provide of NFM test port


NFM DET • Envelope detect at DET diode after amplifying of signal from near field monitor antenna
• Detect signal is sent to MON Board > A/D conversion > 90Hz/150Hz signal detection

1-14
4. Unit Explanation

Unit Explanation

• Amplifier after receive RF signal(from SYN) and audio signal(from AGU)


Fucntion
• Amplitude and phase locking

• CSB : receive 0dBm(from SNN)  amplify 43dBm(20W)


COS_RF
• SBO : receive 0dBm(from SYN)  amplify 25dBm(300mW)
MPA
• CSB : receive 0dBm(from SNN)  amplify 43dBm(20W)
CLR_RF
• SBO : receive 0dBm(from SYN)  amplify 26dBm(40mW)

• CSB, SBO modulation signal generate after composite RF signal and audio signal
Modulation
• Control of gain and phase change

• Receiving of equipment signal and output to ANT


ADU • Input port : 4 port > COS CSB, COS SBO, CLR CSB and CLR SBO
• Output port : 20port > right ANT(10ea), left ANT(L1~L10, 10ea)
ADS
• Receiving of ANT signal and output to equipment
CMU • Input port : 20port > right ANT(10ea), left ANT(L1~L10, 10ea)
• Output port : 3 port > CL, CS and CLR

1-15
1. System Block-diagram

2-1
2. Signal Flow

2-2
3. Test Point & Output

2-3
3. Test Point & Output : SYN Output Signal

@ rear panel
monitor port
SYN Output (COS) SYN Output (CLR)

Spectrum
waveform

Center Frequency : 108.146MHz Center Frequency : 108.154MHz

Difference : 8KHz

2-4
3. Test Point & Output : AGU Output Signal


2-5
3. Test Point & Output : CSB MPA Output Signal

Spectrum Analyzer Oscilloscope

CSB(Carrier+Audio Signal) Channel Power(in general)


 COS : 13W
 CLR : 7W

2-6
3. Test Point & Output : SBO MPA Output Signal

Spectrum Analyzer Oscilloscope

SBO(only Audio Signal) Channel Power(in general)


 COS : 60mW
 CLR : 180mW

2-7
3. Test Point & Output : DETs Output Signal - FWD


2-8
3. Test Point & Output : DETs Output Signal - RVS




2-9
3. Test Point & Output : DETs Output Signal - CMU



2-10
3. Test Point & Output : DETs Output Signal - NFM

2-11
3. Test Point & Output : ID Signal

28dBc(mod. 8%)

1020Hz

2-12
3. Test Point & Output : SYSTEM(FTS)

2-13
3. Test Point & Output : CSP MONITOR

2-14
4. Ethernet Line Connection
Top Panel SIU
▼ ▼
① ②
① ②

COM 1 COM 2 COM3 Ethernet1 Ethernet2 PSU 1 PSU 2 SIU PW

LMMS (Local Monitoring & Maintenance System)


RMMS (Remote Monitoring & Maintenance System)
RF_OUT RF _ OUT RF_ OUT RF_ OUT
RCMU (Remote Control & Maintenance Unit)
RVS_OUT RVS _ OUT RVS_ OUT RVS_ OUT

◄ Rear Panel
FWD _OUT FWD_OUT FWD_OUT FWD_ OUT
DIVIDER DIVIDER DIVIDER DIVIDER
RF_IN RF _IN RF_IN RF_IN

MON OUTPUT MON OUTPUT MON OUTPUT MON OUTPUT

External Network
(10.10.10.X)

① ⓞ
Internal Network (192.169.0.X)

① ②

2-15
5. IP Network Diagram : LLZ Single Type

RMMS CSP AGU #1


192.169.0.100
10.10.10.xxx 192.169.0.1
10.10.10.109

LMMS SIU SIU AGU #2


10.10.10.xxx External HUB 192.169.0.5 192.169.0.2

LIU
RCMU SPU #1 MON #1
10.10.10.119 192.169.0.6 192.169.0.3

SPU #2 MON #2
RMU
192.169.0.7 192.169.0.4

2-16
5. IP Network Diagram : GP Single Type

RMMS CSP AGU #1


192.169.0.100
10.10.10.xxx 192.169.0.1
10.10.10.106

LMMS SIU SIU AGU #2


10.10.10.xxx External HUB 192.169.0.5 192.169.0.2

LIU
RCMU SPU #1 MON #1
10.10.10.116 192.169.0.6 192.169.0.3

SPU #2 MON #2
RMU
192.169.0.7 192.169.0.4

2-17
5. IP Network Diagram : LLZ Multi Type

LMMS RCMU
10.10.10.119
10.10.10.xxx SIU
LLZ #1
External HUB
CSP
10.10.10.109

RCMU
External 10.10.10.139
HUB or Switch SIU
LLZ #2
External HUB
CSP
10.10.10.129

RMMS RCMU
10.10.10.159
SIU
10.10.10.xxx
LLZ #3
External HUB
CSP
10.10.10.149

2-18
5. IP Network Diagram : GP Multi Type

LMMS RCMU
10.10.10.116
10.10.10.xxx SIU
GP #1
External HUB
CSP
10.10.10.106

RCMU
External 10.10.10.136
HUB or Switch SIU
GP #2
External HUB
CSP
10.10.10.126

RMMS RCMU
10.10.10.156
SIU
10.10.10.xxx
GP #3
External HUB
CSP
10.10.10.146

2-19
5. IP Network Diagram : LLZ/GP Multi Type

LMMS RCMU
10.10.10.119
10.10.10.xxx SIU
LLZ #1
External HUB
CSP
10.10.10.109

RCMU
External 10.10.10.116
HUB or Switch SIU
GP #1
External HUB
CSP
10.10.10.106

RMMS RCMU
10.10.10.139
SIU
10.10.10.xxx
LLZ #2
External HUB
CSP
10.10.10.129

2-20
1. Log In

3-1
2. Main Screen

3-2
3. Icon : Diagram

3-3
3. Icon : TX1 Set

3-4
3. Icon : TX2 Set

3-5
3. Icon : Active Path Change

3-6
3. Icon : ACT MON1

3-7
3. Icon : ACT MON2

3-8
3. Icon : STBY MON1

3-9
3. Icon : STBY MON2

3-10
3. Icon : Bypass (Monitor1/2, NFM, FFM)

3-11
3. Icon : System Config

3-12
3. Icon : Main Alert

3-13
3. Icon : PSU Monitor

3-14
3. Icon : ANT Monitor

3-15
3. Icon : Event Message

3-16
3. Icon : Log History

3-17
4. Menu : File

-. Login
-. Print Setup
-. Exit

3-18
4. Menu : Configuration

-. Changeover
-. TX1 Set
-. TX2 Set
-. Monitor 1
-. Monitor 2
-. Standby Monitor 1
-. Standby Monitor 2

3-19
4. Menu : Information

-. System Configuration
-. Version
-. Sensor Reset Setup
-. Realtime Log Monitor
-. View Log
-. TTY Setup
-. Network Setup
-. Power Status Monitor
-. AMP Status Monitor
-. SD Backup Restore
-. System Time Setting
-. Temperature Threshold Setting
-. Antenna Monitor
-. Main Alert Monitor
-. Changeover Test Setting
-. User Management Setting

3-20
4. Menu : Reset

-. Reset Unit

3-21
4. Menu : Help

-. LMMS Information

3-22
1. COURSE LINE(CERTERLINE)

4-1
2. COURSE SECTOR(COURSE WIDTH)

4-2
3. COURSE SHIFT ALARM ADJUSTMENT

4-3
4. COURSE WIDTH ALARM ADJUSTMENT

4-4
1. Comparison (Old & New version)

Efficient
Thermal
Management

Maximize
Maintenance
Efficiency

5-1
1. Comparison (Old & New version)

“SPU”

“DET. Units”
STBY/FWD/CMU/RVS/FWD

“SPU”

Reducing
Data
Error Range

5-2
1. Comparison (Old & New version)

“CSP”

“CSP”

“LIU”
“LCSU”

Improving
Data
Processes
Speed

5-3
1. Comparison (Old & New version)

“AGU & SYN”

“AGU”

Improving
RF
Signal

5-4
1. Comparison (Old & New version)

Item Old Version New Version


CSB Output Level (LLZ) max. 25W / normal 15W max. 30W / normal 20W

CSB Output Level (GP) max. 10W / normal 3W max. 5W / normal 3W

MON Stability 0.1% within 0.1% within

Standby MON Function Output & Phase of CSB/SBO


.
Addition Measurement

Transfer & Shutdown Hot : 1 second within Hot : 1 second within


Time Cold : 3 second within Cold : 3 second within

GUI Display Addition . BITE & MON Test Display

FFM Structure Single Type Dual Type

ADU Electric Phaser Mechanical Phaser

5-5
2. Main Up-grade

MAXIMIZE
CUSTOMER
SATISFACTION

5-6
2. Main Up-grade

Item Contents

 Efficient Thermal Management


Structure
 System Structure and Reconfiguration
Improvement
 Ground Stability and Noise Shielding Rate of Increase

 288MHz~336MHz Full-band Available


 High-precision Control (0.02dB & 0.1 degree step)
ADU Control
 Mechanical Method Manufacture  “First Time in Korea”
Method
 High Frequency Integration Circuit by 4floor Multi-Layer  “First Time in World”
Improvement
 Military Specification Isolator Applied to the Equipment for provide the Noise &
Vibration of Aircraft

MON Stability  Prevention of Monitoring Deterioration


& Signal Quality  IF frequency(75MHz) Using Restrain
Improvement  Synthesizer Configuration Method Improvement

5-7
2. Main Up-grade

Item Contents

Quality Ensuring  Output Ratio Control of CSB & SBO Signal


of  Restriction of CSB&SBO Power Control
CSB/SBO Signal  Operation Routine Improvement for Output Level Correction

 Circuit Redesign
Power Amplifier
 Original Output Level Maintain in spite of Gain Change, Controller Fault
Improvement
 Spurious Prevent flowing through the External Interface

Switching Method
 Temporarily Blocked the Signal Flow When Power Amp. Switch
Improvement
 Prevention of SPU Deterioration When Power Amp. Switch
of Power Amplifier

5-8
2. Main Up-grade

Item Contents

 Real-time Watching Function Strengthen


MON Signal Measuring
 Interface Path Shortening
& Watching Path
 Improvement of Matching Function with CMU and ADU
Improvement
 Improvement of Fault Detector of ADU

Prevention  Improvement of SPU Switching Method


of  Improvement of MPA Feedback Method
Deterioration  Using Restriction of Degradation Device (Diode.,)

 Improve the Reliability of Equipment by Extension of Monitor Port


FFM/NFM Interface
 Additional Interworking of the “NFM”, “FFM” Support through Built-in
Extension
3 Interlocking Port

5-9
3. Strong Point

1) Function block/module simplify Maintenance


2) Interface integration of block/module Efficiency
Maximize
3) Operating power simplify
4) Block arrangement & equipment design change

Spurious Source
1) Base band signal  Direct conversion Removal &
2) Modulator & RF synthesizer  Integration Noise Decrease

1) Adjust the cumulative value can not exceed 10% of the initial value Operation
2) If the output monitoring value is not meet, does not power control Errors & Risk
3) Output calibration work at the night time in the without aircraft’s flight Minimize
4) If the monitoring signal fault occurs after calibration, return to before state

5-10
3. Strong Point

Prevention of
Monitoring
Deterioration

 “removal”

Addition :
Level
Detector

5-11
3. Strong Point

1) RF board input signal increase (14)


2) Detect point improvement Complementary
of
Detect Weak Point

ACT_CL
RF-RX ACT_CS
ACT_CLR
S
STBY_CL
P
M STBY_CS U
U STBY_CLR
X TEST

5-12
3. Strong Point

1) SBO signal tracking (reference : CSB signal) Maintain


2) DDM/SDM ratio not changed Stable & Optimal
Output Signal

Phase Variable Gain Drive Power Isolator


2Way To
From Shifter Attenuator Amplifier Amplifier Amplifier Directional
Divider SPU
Mod Coupler (-30dB)

2Way
50Ohm Divider
Term

RF detector Fixed Fixed


“Amplitude” & Integral Reference Variable Attenuator
Control Circuit
Attenuator

Fixed From Phase


“Phase” Integrated
Reference SPU Detector
Control Circuit

Delay Line Phase Shifter

From
SPU

5-13

You might also like