20 April 2017
Stator slots and coils
Dr. Irfan Ullah
Assistant Professor
Electrical Engineering Department
University of Management and technology
Electrical Machine Design EE424
Contents
1. Example
2. Name plate of induction motor
Example 10.1
Determine the main dimensions, number of radial ventilating ducts, number of
stator slots and the number of turns per phase of a 3.7 kW, 400 volts, 3 phase, 4
pole, 5 Hz squirrel cage induction motor to be started by a star delta stator.
Work out the winding details.
Assume:
Average flux density in the gap = 0.45 Wb/m2
Ampere conductor per meter = 23000
Efficiency = 0.85
Power factor = 0.84
Machines rated at 3.7 kW =, 4 poles are sold at competitive price and therefore
choose the main-dimensions to give a cheap design.
Assume:
Winding factor = 0.955, stacking factor = 0.9
Example 10.1 cont’d
• Main dimensions
(i)
For a cheap design ratio, L/τ = 1.5 to 2 taking L/τ = 1.5
or
Example 10.1 cont’d
•
The length of core is 0.13 m; therefore, one radial duct 10 mm wide is provided
Example 10.1 cont’d
• Turns per phase
(ii)
(iii) Number of stator slots
“Slot pitch should not be
below 10 mm”
Example 10.1 cont’d
• Winding details
(iv)
• 3 slots per pole phase
• 9 slots per pole
• Coil span is 9 slots
https://en.wikipedia.org/wiki/Three-
Example: The coil span should be odd
Example 6.24
• a winding diagram for a 4 pole, 24 slots, 3 phase mush connected armature.
Draw
Solution:
(Even number)
Consider, coil span = 5 slots
3 phase, 24 slots, 4 pole single layer mush
winding (Phase R)
“Coil span should be odd
number in mush winding”
Name plate
Discussion
Thanks
?