The document provides instructions for configuring an MSAG switch including: 1) Configuring the MSAG involves plugging out the slave control board, using a serial port to transfer version files, and setting the host and MSAG IP addresses to be in the same network. 2) Additional steps include configuring the WFTP server, transferring version files via telnet, adding racks, shelves, control cards and configuring VOIP, management IP addresses and routes. 3) Configuring ADSL involves deleting and adding VLANs, tagging ports, enabling PPPOE service, setting the uplink port and enabling port logging. Configuration is saved after completion.

Uploaded by

Abdu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views

Commissioning and Configuration

The document provides instructions for configuring an MSAG switch including: 1) Configuring the MSAG involves plugging out the slave control board, using a serial port to transfer version files, and setting the host and MSAG IP addresses to be in the same network. 2) Additional steps include configuring the WFTP server, transferring version files via telnet, adding racks, shelves, control cards and configuring VOIP, management IP addresses and routes. 3) Configuring ADSL involves deleting and adding VLANs, tagging ports, enabling PPPOE service, setting the uplink port and enabling port logging. Configuration is saved after completion.

Uploaded by

Abdu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 28

Commissioning and Configuration

Configuring the MSAG


Configuring ADSL data
Configuring EPON data
Configuring The MSAG
 We have to plug out the control board(GIS) the one which is not
connected to the PC(slave control board)
 We have to use a serial port to transfer the version files. The Serial
port is connected on one side to the MSAG’s back plane side and
on the other side to the Host.
 We have to also use an IP address for the host (debugging
PC)which is in same IP to the MSAG
i.e. AG IP = 192.168.1.11
Host IP = 192.168.1.15
 Set WFTP
Step 1: Open the WFTP
Step 2: Go to <Security> Then <Users/Rights>
Step 3: New window will be opened. Click <New User>To Create a
new user Enter (username and password)
Step 4: Set the path from which folder the files will be transferred to
the MSAG. Go to <Home Directory> write the path
Step 5: go to <logging> then <Log Options>
Step 6: Check all the check boxes on the new window.
 Restart the MSAG, on the FTP side there is a log file. Press ‘S’ to stop the log file enter
to ICS boot and start transferring the version file from the HOST to the MSAG.
 Some helpful commands
p //show out-band ip, and ftp server ip
c //modify ip (out-band) and username,password
inet on ethernet(e) : 168.10.1.1 9 SLOT GIS OUT-BAND IP
: 168.10.1.2 10 SLOT GIS IP
host inet(h) : 168.10.1.100 PC IP
username/password su3/su3
M //modify the MAC for the out band you can check from GIS card
q //modify the MAC for the CNIC and INBAND you can check from GIS card

 Format all the disks


E C:
E D:
E E:
 Transfer Version file
T icsVer.z
T icsFpga.bin
T icsSlav.bin
T icsSlav1.bin
 Save and restart the MSAG
CTRL+X or L
 TELNET:- We use this mode for configuration, troubleshooting maintaining the
MSAG. We use 2 ports for this purpose
 8888 Port
 1123 Port

First, connect a network cable to the MSAG’s master GIS card front side In band
port and your PC . The MSAGs IP address is already set to (168.10.0.1) by default,
Set your PC IP address (168.10.0.100)
 Go to telnet 8888 mode to transfer the version files
 telnet 168.1.0.1 8888
 Pass: zxmg
 r07_pc2mp <Host IP> <Filename>
i.e. r07_pc2mp 168.10.1.100 agcmd.cfg
Card File names

Main shelf icsFpga.bin, icsSlav.bin, icsSlav1.bin, icsver.z, bootSlav.bin, bootIcs.bin

MP_Config File agcmd.cfg,ntimer.cfg,license.dat

Slave shelf icsfpga_sf.bin ,icsSlav.bin,icsSlav1.bin,icsver_sf.z,


bootSlav.bin,bootics_sf.bin
CNIC bootcnic.bin, pp5.img

MPRB pp53.img, bootMPRB.bin

MPRB Firewall pp53fw1.img,pp53fw2.img,pp53fw3.img,


pp53fw4.img,pp53fw5.img,pp53fw6.img

GILCA gilcaVer.z
 You can check that weather all the versions are transferred to the MSAG or not
r07_fileshow 0 // for the master GIS card
r07_fileshow 1 // for the slave GIS card
r07_vershow 1 0 9 // to see the version files for rack 1 shelf 0 slot 9
 After the file transfer is finished you can restart the MSAG
<msagreset>
 Go to telnet 1123 mode to configure the MSAG.
telnet 168.10.0.1 1123
user: root
pass: root
MSAG#config
MSAG(config)# hostname ETC-BOLE-MSAG-TEST //setting equipment address name
ETC-BOLE-MSAG-TEST(config)#ag

 Add rack
ETC-BOLE-MSAG-TEST(config-ag)# add-rack rack 1 type 1 //you must select the right rack type
1 - STANDARD
2 - STANDARD_EX
3 - ONU100
5 - OUT50C
6 - OUT50D
7 - 23INCH_EX

 
 Add shelf (master and slave)

ETC-BOLE-MSAG-TEST(config-ag)#add-shelf rack 1 physhf 0 type 6 //shelf type must be checked from


equipment site
5 - MICS_EX
6 - MICS_CTL
8 - ONU100
9 - OUT50C
10 - OUT50D
11 - MBSL_CTL
12 - MBSL_EX
13 - TPU_EX
14 - PP_EX
15 - DOUBLEPP_EX 15 - DOUBLEPP_EX
ETC-BOLE-MSAG-TEST(config-ag)# add-shelf rack 1 physhf 1 type 5
ETC-BOLE-MSAG-TEST(config-ag)# add-shelf rack 1 physhf 2 type 5
ETC-BOLE-MSAG-TEST(config-ag)# add-shelf rack 1 physhf 3 type 5
ETC-BOLE-MSAG-TEST(config-ag)# add-shelf rack 1 physhf 4 type 5
 Add Control Card (master and slave shelfs)

Add GIS card:


ETC-BOLE-MSAG-TEST(config-ag)# add-board-mics slot 9 type 3
ETC-BOLE-MSAG-TEST(config-ag)# add-board-sics rack 1 shelf 1 slot 9 type 2 hw1 8
ETC-BOLE-MSAG-TEST(config-ag)# add-board-sics rack 1 shelf 2 slot 9 type 2 hw1 9
ETC-BOLE-MSAG-TEST(config-ag)# add-board-sics rack 1 shelf 3 slot 9 type 2 hw1 10
ETC-BOLE-MSAG-TEST(config-ag)# add-board-sics rack 1 shelf 4 slot 9 type 2 hw1 11
 

 Add Softswitch SS (MGC)

ETC-BOLE-MSAG-TEST(config-ag)#add-mgc mgcid 1 mgctype 1 mgcip 10.208.0.4 mgcport 2944


ETC-BOLE-MSAG-TEST(config-ag)#add-mgc mgcid 2 mgctype 1 mgcip 10.209.0.4 mgcport 2944
 
 Config Voip and Manage ip:

in-band management:
ETC-BOLE-MSAG-TEST(config)#vlan add 300 //VOIP vlan
ETC-BOLE-MSAG-TEST(config)#vlan add-port 300 port 0/9/0 untagged // 0/9/0 is uplink port,tagged or
untagged must be confirm.
ETC-BOLE-MSAG-TEST(config)#route interface ipaddress 7.7.7.7 mask 255.255.255.0 vid 300
ETC-BOLE-MSAG-TEST(config)# route static ipaddress 10.0.0.0 mask 255.0.0.0 nexthop 7.7.7.99
 
voip:
ETC-BOLE-MSAG-TEST(config-ag)#add-mg protype 1 mgport 2944 mgcid1 1 mgcid2 2
ETC-BOLE-MSAG-TEST(config-ag)#add-voip-interface type 1 ipaddr 10.208.2.26 submask 255.255.252.240
ETC-BOLE-MSAG-TEST(config-ag)#add-voip-route nexthop 10.208.2.17
ETC-BOLE-MSAG-TEST(config)#vlan add 2102
ETC-BOLE-MSAG-TEST(config)#vlan add-port 2102 port 0/9/0 untagged //0/9/0 is uplink port,tagged or
untagged must be confirm.
ETC-BOLE-MSAG-TEST(config)#vlan voipmed add 2102
 
 
 Add the user card,test card and subscribers to the user card
ETC-BOLE-MSAG-TEST(config-ag)#add-board-slc slot 3 type 27 //add ralc board
ETC-BOLE-MSAG-TEST(config-ag)#add-board-slc slot 4 type 47 //add GILCA board
ETC-BOLE-MSAG-TEST(config-ag)#add-board-tslc rack 1 shelf 0 slot 17 //add TSLC board
ETC-BOLE-MSAG-TEST(config-ag)#add-slctermid rack 1 shelf 0 beginslot 3 beginindex 0 num 32 tmidfix USER type 1
ETC-BOLE-MSAG-TEST(config-ag)#add-slctermid rack 1 shelf 0 beginslot 4 beginindex 16 num 16 tmidfix USER type 1
 
 Add mpr/b card, circuits media net for the mpr/b cards
ETC-BOLE-MSAG-TEST(config-ag)#add-board-mprb slot 11
ETC-BOLE-MSAG-TEST(config-ag)#add-board-mprb slot 12
ETC-BOLE-MSAG-TEST(config-ag)#add-ipstermid slot 11 subcard 1 tmidfix RTP
ETC-BOLE-MSAG-TEST(config-ag)#add-ipstermid slot 12 subcard 1 tmidfix RTP
ETC-BOLE-MSAG-TEST(config-ag)# add-mednat slot 11 subcard 1 nicslot 9 inphyport 5 exphyport 5 exipaddr
10.208.2.26 udpport 8000
ETC-BOLE-MSAG-TEST(config-ag)#add-mednat slot 12 subcard 1 nicslot 9 inphyport 5 exphyport 5 exipaddr
10.208.2.26 udpport 10000
 
 Enable the Uplink port
ETC-BOLE-MSAG-TEST(config)#port enable 0/9/0 // 0/9/0 is uplink port

 Save what you have done


ETC-BOLE-MSAG-TEST(config)#save
 

 
ADSL Configuration
The configuration is as follows:-
MSAG-TEST(config)#show vlan num *to see the vlans data*
MSAG-TEST(config)# vlan del 2999 *to delete vlan *
MSAG-TEST(config)#vlan del 1001-1210 *to delete vlan *
MSAG-TEST(config)#vlan add 1001-1600 *to add vlan *
MSAG-TEST(config)#vlan add-port 1001-1600 port 0/9/2 tagged *to tag the uplink
port to the vlans *
MSAG-TEST(config)#vlan add-port 1001-1144 port 0/5/0-0/16/15 untagged one-to-
one *to tag the subscriber port to the vlans *
MSAG-TEST(config)#vlan add-port 1211-1258 port 1/3/0-1/5/15 untagged one-to-one
*to tag the subscriber port to the vlans *
MSAG-TEST(config)#port-location format china-telecom *to set the port location*
MSAG-TEST(config)#pppoe vendortag enable *to enable the pppoe service*
MSAG-TEST(config)#pppoe uplink port 0/9/2 *to set the pppoe’s uplink port*
MSAG-TEST(config)#dsl port-log enable *to enable log*
MSAG-TEST(config)#save *to save data*
MSAG-TEST(config)#are you sure you want to save configure data ?[y/n] y
Many Thanks !!!