PowerEdge MX IO Guide
PowerEdge MX IO Guide
The content in this guide applies to all versions of PowerEdge MX up to and including 1.40.00
Example Topologies
Additional Resources
EO EO
NIC Type CNA NIC NIC NIC NIC • UEFI iSCSI iBFT Boot
Dell PN 51G0W HJ3FX H9NTY WCHFY DCWFP • UEFI PXE Boot
SKU 543-BBDI 543-BBDJ 543-BBDH 543-BBDK 555-BGGB • Legacy PXE Boot
General • NVGRE
NPAR (# Partitions) Yes (8/port - 16 total) Yes (8/port – 16 total) No No Yes (4/port – 16 total) • VxLAN
Secure Firmware Updates Yes Yes Yes Yes Yes • IP, TCP, UDP checksum offloads
PTP: IEEE 1588 Yes Yes Yes Yes Yes • Large Send Offload (LSO)
DPDK Yes Yes Yes Yes Yes • Receive-Side Scaling (RSS)
Network Boot • Giant Send Offload (GSO)
UEFI iSCSI Offload Boot Yes No No Yes (boot, no offload) No
UEFI FCoE Boot Yes No No No No
Legacy iSCSI iBFT Boot No No Yes Yes Yes (UEFI & PXE only)
RDMA
RoCE v1 Yes Yes No Yes Yes
RoCE v2 Yes Yes No Yes Yes
iWarp Yes Yes No No No
Offloads
iSCSI HW Offload Yes No No No No
FCoE HW Offload Yes (1 FCoE partition/port) No No No No
Large Receive Offload (LRO) Yes Yes No Yes Yes
TCP Segmentation Offload (TSO) Yes Yes No Yes Yes
Transmit-Side Scaling (TSS) Yes Yes No Yes Yes
Network Virtualization Overlay
GENEVE Yes Yes Yes Yes Yes
VxLAN-GPE No No Yes Yes Yes
MPLS Yes Yes Yes Yes Yes
NVMe-oF
NVMe-oF: TCP Yes Yes Yes Yes Yes
NVMe-oF: RDMA (RoCE v2) Yes Yes No Yes Yes
EO EO
NIC Type HBA HBA HBA HBA
Dell PN 17N63 31KFT G620Y PD8ND
SKU 544-BBCM 544-BBCN 544-BBCO 544-BBCP
General
Configuration through F10 and F2 consoles Yes Yes Yes Yes
Out-of-band Firmware Updates Yes Yes Yes Yes
Inventory and Configuration through iDRAC Yes Yes Yes Yes
Secure Firmware Updates Yes Yes No No
NVMe-oF: FC Yes Yes Yes Yes
A B
A B
E Fabric Slot A1
E F
Fabric Slot A2
Scalable Networking Storage Networking
• Two redundant • Redundant, highly
general-purpose available
fabrics • 32G Fibre Channel or
12G SAS storage
• MX Scalable Fabric fabric
Architecture for multi- E Fabric Slot B1
chassis networking
Fabric Slot B2
• Future forward design
F Fabric Slot C1 Fabric Slot C2
High-performance, scalable 25G fabric switch 16 x 25GbE internal ports 2 x 100GbE/32Gb FC QSFP28 Uplink Ports
1GbE and 10G-BaseT are DAC-Q28DD-2Q28-100G-xM DAC-Q28DD-8S28-25G-xM DAC-Q28-4S28-25G-xM Q28-128GFC-SW4 (4x32GFC Optic)*
supported via the QSA28 OR OR OR AND
adapter AOC-Q28DD-2Q-40G-7M AOC-Q28DD-8S28-25G-xM AOC-Q28-4S28-25G-xM CBL-MPO12-4LC-OM4-xM
OR OR OR
Q28DD-80G/200G-2SR4 (Optic) Q28DD-80G/200G-2SR4 (Optic) Q28-100G-SR4-NOF (Optic)
AND AND AND
CBL-MPO12DD-2MPO12-OM4-xM Corning Edge8 Cabling CBL-MPO12-4LC-OM4-xM
NOTE: Not every option is presented on this page. Please contact your account team for additional options
15 © Copyright 2021 Dell Inc.
Connecting to Non-Dell EMC 10GbE or 25GbE uplink ports
For example: Cisco, Arista, Juniper
A port group is a logical descriptor given to one or more physical ports that
supports one or more logical configurations.
Port
Group 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 19 21 23 25 27 29 31 33 35 37 39
Physical Ports 18 20 22 24 26 28 30 32 34 36 38 40
41 42 43 44
NOTE: The MX5108n does not support the Broadcom 57504 Quad Port Ethernet adapter
NOTE: The MX5108n does not support the Broadcom 57504 Quad Port Ethernet adapter
210-ANZJ 210-ANZI Dell EMC MX5108n 25GbE Ethernet Switch, 4x10G-BaseT, 1x40GbE QSFP+, 2x100GbE QSFP28
470-ABOG 470-ABPE Dell Networking Cable, MPO to 4xLC, Fiber Breakout Cable, MMF, OM4, Optics Required, 3M
470-ABOH 470-ABPG Dell Networking Cable, MPO to 4xLC, Fiber Breakout Cable, MMF, OM4, Optics Required, 5M
470-ABOI 470-ABPK Dell Networking Cable, MPO to 4xLC, Fiber Breakout Cable, MMF, OM4, Optics Required, 7M
NOTE: These optics & cables are NOT supported in QSFP28 or QSFP+ ports
*OS10.5.0.1 or higher is required to use optics & passive fiber for FSE/FEM connections
24 © Copyright 2021 Dell Inc.
Speed Compatibility for Cables/Optics
• When configuring a port for a specific speed or breakout, a compatible cable/optic must be used
• DAC cables are generally multi-speed
– For example, a QSFP28 DAC cable can run at 100G, 4x25G, 40G, 4x10G
• Use the table below to ensure that the correct cable/optic is being used
Description Type Primary Speed Port Type 2x100G 100G 2x40G 40G 8x25G 4x25G 8x10G 4X10G
40G DAC DAC 40G QSFP+ X X
100G DAC DAC 100G QSFP28 X X X X
4x25G breakout DAC DAC 100G QSFP28 X X
8x25G breakout DAC DAC 100G QSFP28-DD X X
2x100G QSFP28-DD DAC DAC 100G QSFP28-DD X X X X X X X X
40G AOC or Transceiver Optical 40G QSFP+ X X
100G AOC or Transceiver Optical 100G QSFP28 X X
2x100G/2x40G QSFP28-DD Transceiver Optical 100G QSFP28-DD X X X X X X X X
2x100G QSFP28-DD AOC or Transceiver Optical 100G QSFP28-DD X X X X
2x40G QSFP-DD AOC or Transceiver Optical 40G QSFP28-DD X X X X
The QSA28 Adapter is a QSFP form factor carrier that allows a SFP, SFP+,
or SFP28 optic/cable to be inserted into a QSFP+, QSFP28, or QSFP28-DD
port. This provides the ability to support a single 1G, 10G, or 25G
cable/optic 25 © Copyright 2021 Dell Inc.
PowerEdge MX Ethernet Pass-through Modules
25GbE Pass-through Module 10G-BaseT Pass-though Module
16 x 25GbE internal ports 16 x 25GbE internal ports
DAC-SFP28-25G-xM DAC-SFP-10G-xM
OR OR
AOC-SFP28-25G-xM DAC-SFP28-25G-xM*
OR OR
SFP28-25G-SR-NOF AOC-SFP-10G-xM
AND OR
CBL-LC-OM4-xM SFP-10G-SR
AND
CBL-LC-OM4-xM
16/32GFC (LWL)
• Additional 16G FC and 32G FC optics can be purchased for – Flow Vision enables host to LUN flow monitoring, application flow mirroring for
offline capture and deeper analysis, and test traffic flow generation function for
activated ports SAN infrastructure validation
– IO Insight automatically detects degraded storage IO performance with integrated
device latency and IOPS monitoring embedded in the hardware
• NOTE: A port license is consumed when that port is – ClearLink (D_Port) to non-Brocade devices allows extensive diagnostic testing of
activated, regardless if port is internal or external (QSFP links to devices other than Brocade switches and adapters. (Functionality requires
support by attached device, availability to be checked by the user)
ports count as 4 licenses)
• Extended Fabric: Provides greater than 10km of switched fabric
connectivity at full bandwidth over long distances
• NOTE: While 32 licensed ports is technically possible, 24
ports is the maximum number of ports that are usable. Don’t • NOTE: These features are only available in the Enterprise Bundle -
individual feature licenses are not available
purchase more than 24 port licenses
8 ports licensed = 6 servers & 2 external uplinks, 7 servers & 1 external uplink, or any combination that = 8
16 ports licensed = 8 servers & up to 8 external uplinks (any combination of SFP+ & QSFP ports)*
24 ports licensed = 8 servers & all 16 external uplinks
NOTE: If you need the enterprise bundle, purchase the SKU with the license included (210-AOCM). Do not
purchase a different SKU and then add the stand-alone ENT license bundle
NOTE: As of Dec 6th, 2021, Brocade software licenses are delivered digitally/electronically
32 © Copyright 2021 Dell Inc.
Fibre Channel Optics & Cables for MXG610s
Factory SKU After Sale SKU Description
407-BBCF 407-BBBB Brocade 16G SFP SWL Fibre Channel, 1 pack, requires port license (Supports 8G/16G)
407-BBXJ 407-BBXM Brocade 32G SFP SWL Fibre Channel, 1 pack, requires port license (Supports 8G/16G/32G)
407-BBXK 407-BBXL Brocade 32G SFP SWL Fibre Channel, 8 pack, requires port license (Supports 8G/16G/32G)
407-BBXH 407-BBXO Brocade 32G SFP LWL, 10Km SMF, 1 pack, requires port license
407-BBXI 407-BBXN Brocade 32G SFP LWL, 10Km SMF, 8 pack, requires port license
Brocade 32G QSFP SWL Fibre Channel QSFP (4 x 32G),1 pack, requires 4 port licenses
407-BCBB 407-BCBC
(Supports 16G/32G)
NOTE: These optics are NOT supported in the MX9116n Fabric Switching Engine
MMF LC/LC cables for SFP+ SWL optics
Factory SKU After Sale SKU Description
470-ACMB 470-ACLV OM4 LC/LC Fiber Patch Cable 1 Meter
470-ACLS 470-ACLT OM4 LC/LC Fiber Patch Cable 2 Meter
470-ACMF 470-ACMO OM4 LC/LC Fiber Patch Cable 3 Meter
470-ACLK 470-ACLY OM4 LC/LC Fiber Patch Cable 5 Meter
470-ACMH 470-ACMN OM4 LC/LC Fiber Patch Cable 10 Meter
• Mixing MX9116n and MX7116n within the same fabric *IS* allowed
• No mixing of Ethernet switch and Pass-Through Modules within the same fabric on
MX7000
– For example, MX9116n in A1 and 25G PTM in A2 is not allowed
Chassis 3:
Slot A1: MX7116n
Slot A2: MX7116n
…
Chassis 10:
Slot A1: MX7116n
NOTE: If a Scalable Fabric has some chassis with
Slot A2: MX7116n Quad Port NICs and some with only Dual Port
NICs, only the chassis with Quad Port NICs
require the second FEM port to be connected
…
with Quad Port NICs
require the second FEM
port to be connected
Chassis 10:
Slot A1: MX7116n
Slot A2: MX7116n
Slot B1: MX7116n
Slot B2: MX7116n
38 © Copyright 2021 Dell Inc.
Supported Scalable Fabric Topologies*
Dual Port NICs
These topologies are for scenarios where two physical NICs per server are required but only one pair of
MX9116n FSEs are desired
3-5 Chassis
3 Chassis
Chassis Connection Order support QSFP28 and QSFP+ Optics and cables
In order to provide optimal performance through the MX9116n FSE, it is recommended to connect
the FEMs to the FSE in the following order:
Port
Group 1 2 3 4 5 6 7 8 9 10 11 12
1&2 4 6 8 10 3 5 7 9
Connect FEM
from Chassis 6 to QSFP28-DD ports not used for FEM connections can be
Port-Group 3 utilized for additional uplinks, connections to rack servers, or
VLT connections (VLT is required for SmartFabric Services)
in both Full Switch and SmartFabric mode.
44 © Copyright 2021 Dell Inc.
PowerEdge MX networking with Embedded Top of Rack switching
Additionally, the cable/optic type used will vary depending on the length required
Cable DAC AOC Optic2 Fiber
Description Connector
Option (very short) (short-medium) (medium-long) (Requires Optic)
CBL-MPO12DD-OM4-xM or
1 FSE/FEM Connection QSFP28-DD DAC-Q28DD-200G-xM AOC-Q28DD-200G-xM Q28DD-80G/200G-2SR4
Corning Edge8 Structured Cabling
5 Breakout 8x25GbE QSFP28-DD DAC-Q28DD-8S28-25G-xM AOC-Q28DD-8S28-25G-xM Q28DD-80G/200G-2SR4 Corning Edge8 Structured Cabling
6 Breakout 8x10GbE QSFP28-DD DAC-Q28DD-8S28-25G-xM AOC-QDD-8SFP-10G-xM Q28DD-80G/200G-2SR4 Corning Edge8 Structured Cabling
1 – The QSFP-64GFC-SW4 (4x16GFC Optic) is EoL as of 15 October 2020. Use Q28-128GFC-SW4 (4x32GFC Optic) instead.
2 – SR4 transceivers support distances up to 150M over OM4 fiber. The MX7000 management modules use 1G BASE-T cables with a distance limit of 100M, therefore the effective useable length for a SR4 optic is
100M over OM4 fiber
Cable Option 1
Fabric A Populated
Cable Option 1
Fabric A & B Populated
Chassis 1 & 2
Cable Option 1
Cable Option 1
Chassis 3-10
Upstream Switches
FC Switches
FC Array
ToR Switches
ToR Switches
Cat 6A Copper
Cable Option 3
ToR Switches
*Pass-Through to Dell EMC networking switches only. Non-Dell switches are not supported
57 © Copyright 2021 Dell Inc.
Example Topologies
Scalable Fabric Wiring Diagram – 2 Chassis with Quad Port NICs
Cable Option 1
Fabric A Populated
Cable Option 1
Fabric A & B Populated
Chassis 1 & 2
Cable Option 1
Cable Option 1
Chassis 3-5
SMF (Optical) Single-Mode fiber “QSFP-DD” Quad Small FormFactor Pluggable – Double Density
9-um Tiny core fiber • QSFP28-DD = 2x100G 8 Channels
2/10Km reach • QSFP56-DD = 2x200G 16 Fibers or wires
Hard to attach components • QSFP112-DD = 2x400G 10W
Transceivers are expensive
MPO12DD 16 fiber parallel optical connector
SMF cost less than dental floss!
For more information, see the Optic and Cable FAQ: https://www.dell.com/support/kbdoc/000134129/faq-optics-and-cables
Structured Cabling
• Dell EMC has partnered with Corning Structured Cabling Solutions to provide an easy to customize
structured cabling solution
– Standard Dell ProDeploy and ProDeploy+ services do not include installation for Corning Structured Cabling Solutions.
Contact your account team for options for a custom installation contract if needed
• This solution provides rack housings from 1U to 4U allowing for multiple cassette types in each enclosure.
The system has cassettes to do the following:
– QSFP breakout to 4xLC (MPO12 to 4xLC)
– QSFP to QSFP extension (MPO12 to MPO12)
– QSFP-DD to 2xQSFP28 (MPO12-DD to 2xMPO12)
– QSFP-DD to 8xLC (MPO12-DD to two 4xLC cartridges)
– QSFP-DD to QSFP-DD extension (MPO12-DD to MPO12-DD)
68 © Copyright 2021 Dell Inc.
EDGE8® HD Housings
• EDGE8® HD housings include
– Mountings for standard 19” racks and cabinets
– Sliding drawers, enabling module or panel installation from the
front or rear of the housing.
– Integrated cable routing elements to make real structured
patch cord management possible while providing finger
access without the need for tools or any other accessories.
– Side-routing guides for patch cord integration to the cabinet
which provide flexible installation options for back-to-back or
flush-mounting requirements
– Quick-mount capability making it quick and easy for one
person to install the housing with little effort.
– Easy labeling with a full-size mounting area on the inside of the
front door
– An easily installable trunk mounting plate providing flexibility
depending on your design (e.g., back-to-back) or application
(e.g., reduced depth) concept.
– 1U, 2U, and 4U housing options
69 © Copyright 2021 Dell Inc.
EDGE8® Modules & Adapter Panels
• EDGE8® Modules
– The EDGE8® modules have an MPO interface on one side and four LC interfaces
on the other
– All EDGE8® modules can be installed without tools from the front or the rear of
any EDGE8® housing.
– LC duplex adapters feature hinged shutters that move up and out of the way
when the connector is inserted. Specially designed indents in the shutters ensure
that the end faces of the connectors are never touched.
– In addition, the shutters are visual fault locator (VFL) compatible to allow easy
port identification while diffusing the VFL light to ensure adequate eye safety.
Q28DD-200G-2SR4
3 3 Q28DD-200G-2SR4
1 2 1
Rack 1 Rack 2
1 2
4
Rack 1 Rack 2
Rack 1 Rack 2
4 5
Dell EMC Networking MX9116n Spec Sheet Dell EMC Networking MX9116n Spec Sheet https://www.dell.com/learn/product_docs/dellemcnetworkingmx9116nspecsheet.pdf
Dell EMC Networking MX7116n Spec Sheet Dell EMC Networking MX7116n Spec Sheet https://www.dell.com/learn/product_docs/dellemcnetworkingmx7116nspecsheet.pdf
Dell EMC Networking MX5108n Spec Sheet Dell EMC Networking MX5108n Spec Sheet https://www.dell.com/learn/product_docs/dellemcnetworkingmx5108nspecsheet.pdf
Dell EMC Networking MXG610s Spec Sheet Dell EMC Networking MXG610s Spec Sheet https://www.dell.com/learn/product_docs/dellemcnetworkingmxg610sspecsheet.pdf
Dell Networking Optics Spec Sheet Dell Networking Optics Spec Sheet https://www.dell.com/learn/shared-content~data-sheets~en/documents~dell-networking
-optics-spec-sheet.pdf
Dell EMC eLabs Networking Switch Support Current support matrix of Dell EMC Networking
https://elabnavigator.emc.com/vault/pdf/Dell_EMC_Networking_Switch.pdf?key=15234
Matrix for Storage Ethernet switches and Dell EMC Storage platforms 28507371
MX9116n Support Page https://www.dell.com/support/home/product-support/product/networking-mx9116n
Sept 26, 2018 1.1.2 Corrected FC Gateway Topology, Fixed headers, updated cable images, corrected NPAR support for Intel NICs
Updated PTM image, Added additional cables & optics to 25G PTM, Scalable Fabric design for Dual Fabrics, Clarified supported 40G optics, updated
October 25, 2018 1.2 Mellanox NIC information, added Additional Resources section, information on connecting to Cisco switches, unsupported topologies for Scalable Fabric
and SmartFabric services
Clarified items on the switch Quick Reference page, added IOM slot matrix, corrected SKU numbers, updated Dell EMC 4x32G FC optic to reflect support
January, 2019 1.3
for 4x 8G FC, corrected description of MXG610s on QRG page, updated list of white papers
Clarified cables/optics for VLTi on MX5108, updated NPAR support on NIC QRG, corrected SKU numbers, updated resources and whitepaper links,
May, 2019 1.4
updated MX7116n QRG, Updated Layout/Template
Updated multiple slides to add new cables/optics supported with OS10.5.0, Added Slide for MX7116n FEM as Pass-Through Module, Updated & Added
September, 2019 1.5
whitepaper links, Added information about Corning Edge8 Structured Cabling
March, 2020 1.6 Updated Brocade SKUs, Minor other corrections, updated broken links
Clarified MXG610s QRG, Updated Edge8 ProDeploy policy, clarified number of NPAR partitions for Marvell NICs, updated max supported VLANs for
June 2020 1.7
switches, updated MX7116n breakout options for 10G Support
Added content for Broadcom 57504 quad port NICs, Added content for new Scalable Fabric topologies, Added example topology for direct attached FC,
August 2020 1.8
corrected broken links, additional information on QSFP28-DD cables, minor updates and corrections
October 2020 1.9 Updated FC Mezz QRG, Adjusted to account for EOL of QSFP-64GFC-SW4
Added cable configuration for QSFP to QSFP FC optic connection, updated multiple Scalable Fabric and example topology slides, added cable/speed
April 2021 1.10 compatibility slide, added C&O FAQ and C&O spec sheet link to resources section, Updated DD optic references to Q28DD-80G/200G-2SR4 Dual-Rate
optic
December 2021 1.11 Added new MSA types, updated brocade license SKUs, updated switch P*V limits, Updated Topologies, minor updates and corrections