TURBOMACHINES

Chapter 7
STEAM TURBINES
05/17/2024 1
Steam turbines may be of two kinds, namely
(i)

impulse turbine
In Impulse turbine, the enthalpy drop (pressure drop) completely
occurs in the nozzle itself and when the fluid pass over the moving
blades it will not suffer pressure drop again.
Hence pressure remain constant when the fluid pass over the rotor
blades. Fig. shows the schematic diagram of Impulse turbine.

05/17/2024 2
(ii) Reaction turbine.
• In Reaction turbines, addition to the pressure drop occurs in the
nozzle there will also be pressure drop occur when the fluid passes
` over the rotor blades. Fig. shows the Reaction turbine.
• Most of the steam turbine are of axial flow type devices except
Ljungstrom turbine which is a radial type.

05/17/2024 3
Velocity Compounding (Curtis Stage) of Impulse Turbine:

05/17/2024 4
Pressure Compounded (Rateau Stage) Impulse Turbine:

05/17/2024 5
Pressure-Velocity Compounding:

05/17/2024 6
Impulse Reaction turbine:

05/17/2024 7
Analysis on single stage turbine:
1. General velocity diagram of Impulse turbine:
If there is no frictional loss, then the axial thrust is zero as Vf1
= Vf2 and Vr1 = Vr2

05/17/2024 8
Velocity vector diagrams:

05/17/2024 9
5. Condition for Maximum Utilization Factor or Blade
efficiency with equiangular Blades for Impulse Turbine:
Consider the velocity diagram shown in fig (a).

Due to the effect of blade friction loss, the relative velocity at


outlet is reduced than the relative velocity at inlet. Therefore
Vr2 = Cb Vr1. Corresponding velocity triangle shown if fig (b)
05/17/2024 10
Analysis on two stages:
1. Condition for maximum efficiency for velocity compounded
Impulse turbine (Curtis Turbine)

05/17/2024 11
Then the maximum blade efficiency is,

Maximum total work done per kg of steam,

05/17/2024 12
Reaction turbines:
These are of axial type. But pure reaction turbine are not in
general use, only impulse-reaction turbines are used.
1. The velocity triangle for general case:

In reaction turbine steam continuously expands as it flows over


the blades thereby increases the relative velocity of steam,
i.e., Vr2 > Vr1
05/17/2024 13
2. Degree of reaction (R):
The degree of reaction for reaction turbine stage is defined as
the ratio of enthalpy drop in the moving blades to the total
enthalpy drop in fixed and moving blades (i.e., static
enthalpy drop to total enthalpy drop), as shown in fig.

05/17/2024 14
The variation ηb with blade speed ratio Φ for the reaction stage
is shown in fig.

05/17/2024 15
Effect of Reheat Factor and Stage Efficiency:
Consider a turbine with n number of stages, say n = 4 as shown
in fig.

05/17/2024 16