LSB LIEBHERR System Bus
DWB
LSB LIEBHERR System Bus
DWB
LSB LIEBHERR System Bus
DWB
LSB LIEBHERR System Bus
DWB
LSB LIEBHERR System Bus
Above 2.5 Volts = 1
DWB
LSB LIEBHERR System Bus
Below 2.5 Volts = 0
DWB
LSB LIEBHERR System Bus and Can Bus
LSB 24 Volt System
24 Volts
Ground
Signal 13-17
Volts
>2.5V = 1 37,000 Bits Per Second
<2.5V = 0 Up to 8 LSBs and will function up to 800 Feet
Can Bus
2.7 V Can High 5 Volt System
Ground
2.3 V Can Low
>2.5V = 1 450,000 Bits Per Second
<2.5V = 0 Will function up to 40 Feet
DWB
Can Bus System
DWB
LSB LIEBHERR System Bus
LSB LIEBHERR Data Bus
24 V
1
13-17
V
1111111 11 11
2.5 V
0 00000 000 0000
0V
TIME
DWB
Normal
Operating LSB
2.5 Amp Fuse
in Sensor Green LED On
Red LED Flickering
DWB
Short to Ground LSB in
a sensor. LSB Off Line
2.5 Amp Fuse
in Sensor Green LED On
Sensor holds a
Constant Ground
Red LED Off
DWB
Short to ground Short to Ground LSB in Wiring Harness.
wiring LSB Off Line
2.5 Amp Fuse
in Sensor Green LED On
Ground in
the wiring
Short to
ground
Red LED Off
DWB
Pin 4
Breakout Box 2.5 Amp Fuse
that comes in Sensor
with the crane
Sensor holds a
Constant Ground
Red LED Off
DWB
5 Amp fuse Pulling the Jumper on Pin 4 and the
Red LED comes back it is a short to
Pull the Jumper on Pin ground in a Sensor or in the wiring
4
24 Volts
Breakout Box 2.5 Amp Fuse
that comes in Sensor
with the crane
Red LED On
DWB
5 Amp fuse Send 24 Volts through a 5 Amp
fuse only into the sensor side of
the LSB system
Pin 4 Jumper Removed
24 Volts
Breakout Box 2.5 Amp Fuse
that comes in Sensor
with the crane
Sensor holds a
Constant Ground
Red LED On
DWB
5 Amp fuse If a Bus Participant is grounded
the internally the 2.5 Amp fuse
blows
24 Volts
Breakout Box 2.5 Amp Fuse
that comes in Sensor
with the crane Blows
Sensor holds a
Constant Ground
Red LED On
DWB
5 Amp fuse When the Jumper is put back in the Red
LED stays on because the short is now
Jumper on Pin 4 gone. The Sensor shows up in LSB as
missing from Bus
24 Volts
Breakout Box 2.5 Amp Fuse
that comes in Sensor
with the crane Blown
Sensor holds a
Constant Ground
Red LED On
DWB
5 Amp fuse Blows If the LSB is grounded in the
wiring harness the 5 Amp fuse
blows
Pull the Jumper on Pin
4
24 Volts
2.5 Amp Fuse
in Sensor
Ground in
the wiring
Short to
ground
Red LED On
DWB
Normal
Operating LSB
2.5 Amp Fuse
in Sensor Green LED On
Red LED Flickering
DWB
The Signal wire is Normal
shorted to 24 V power Operating LSB
2.5 Amp Fuse
in Sensor Green LED On
Red LED Flickering
DWB
The Signal wire is Short to Power
shorted to 24 V power LSB
2.5 Amp Fuse
in Sensor Green LED On
Red LED Goes Out
DWB
Unplug all LSB
Connectors
2.5 Amp Fuse
in Sensor Green LED On
Red LED stays Off
DWB
Unplug all LSB
Connectors
2.5 Amp Fuse
in Sensor Green LED On
Cycle the Ignition
Switch
Red LED ON
DWB
Plug Connectors one at a time until the
The Signal wire is Red LED goes out
shorted to 24 V power
2.5 Amp Fuse
in Sensor Green LED On
Red LED Goes Out
DWB