RASNAL VKP
Rasnal VKP will provide ideal protection with
integrated Surge & Spike Protection For the Digital
Electronics. In the Protection Zone, Common low
impedance Grounding , equi-Potential Function, Surge
& Static elimination Via Energy conversion function
and does not require separate grounding & creates a
Lowest Low impedance path for leakage, Surge /
Spike to convert into very low heat.
Digital Grounding Device VKP-1-AC/ 03-AC
For installation at LPZ 1-2 (Lightening protection Zone),
protecting low voltage equipment from surge damage.
Applied in modular SPD Class (Class C).
Key Advantages
Total Protection of Digital equipment’s from Grid disturbances.
Total Protection of Digital Equipment’s from Lightning & Switching
Surges.
Provides Lowest Impedance Grounding.
Static Charge Eliminator.
Provides Low impedance path to Leakage Current.
Reduces 2% harmonics
Provides Equi-Potential common Grounding
Maintain Earth to Neutral voltage less than 01Volt
Enhance Battery Life
Environments for Lightning & Surge Protection is changed as
below some adopt difficult Concept of Protection.
Today most of electronic, communication, data systems or connected under
network
IC Chips become high integrated level with very thin internal Circuit which is very
weak from Surge intrusion
Global Warming occurs more frequent lightning, multi-stage lightning (not
simple single lightning) which normal surge protective device could not care.
Nearby Direct Lightning affects your systems under GPR effect (Ground Potential
Rise) which is shown very frequently at out-door or isolate buildings or isolate
facilities.
Prefect Protection Solutions for following environment
1. Integrated lightning surge protection for Data
Communication Systems, EPABX & Intercom,
Network, Automated.
2. Such areas which have low grounding resistance are
unable to get proper grounding resistance Like
rocky, mountain area.
3. Mobile tactical vehicles for good Earthling.
4. Frequently surge damaged sites.
5. Under bad weather & frequent – lightning
environment, system facilities should be operated
24x7.
6. This solution has been installed at numerous
problematic areas, and has solved all the lightning
surge problems for military communications. CCTV
surveillance systems, support under bad weather
conditions.
This is specially designed for perfect lightning protection
under above environment:
Ideal perfect lightning protection with integrated surge protection for
systems in the protection zone, Common grounding , equip-potential
function , surge elimination via energy conversion function , No
secondary Grounding rod required for low earthing resistance, targeting
perfect lightning surge protection for advanced networked systems.
Technical Features
• Works on Energy Conversion principle it is known as Digital Grounding
Apparatus.
• Detect Surges Convert them into the heat energy and dissipate through low
impedance Ground. These Surges enters via electrical & communication lines
through conductive structure (Like communication cable, IF cables, RF cables,
Water pipe, Gas pipeline, steel structure etc.)
• Provide Equi-Potential bonding to all the equipment and improve the earth
resistance.
• Provides low impedance Ground to eliminate static charges & leakage current.
• Integrated protection system to protect equipment depending upon the
electrical wiring layout
Technical Specification VKP-01
TECHNICAL SPECIFICATIONS FOR DIGITAL GROUNDING DEVICE VKP-01 (SINGLE PHASE)
Sr No. Essential QRs Acceptable range
1 Rated input voltage 100VAC--275VAC-1 Phase
2 Frequency 50 - 60 Hz
3 Maximum Continuous operating voltage (Uc) 275 Volts (L-N), 255 Volts (N-G)
4 Maximum Surge Handling capacity 120 kA (8/20 micro seconds)
5 Mode of protection 3Modes (1 Phase, 3 wire) L-N,L-E & E-N
6 Maximum surge current (8/20µS) 40 Ka each mode
7 Nominal discharge current (8/20µS) 10 kA each mode
8 Short circuit withstand current 10 kA
9 Residual current 0.001 amps
10 Residual voltage 1.59 kV (L-N) & 1.06 (N-G) with 8/20 micro sec.
11 Spark over voltage (8/20µS) 1.5kV
12 Standby power consumption 3.87 W/hrs.
13 Impulse Response Time <25 Nano Second
14 Max. Leakage Current at 75% V₁mA , IL(µᴀ) 20µᴀ
15 Status indication LED indications
16 Reference Capacitance @1KhHz 1700 pF
17 Surge Conter 6 Digit, 7 Segment LCD counter
18 Communication Port RJ45 or 8 Pin Connector
19 Operating temperature (-40 degree(s)C ~ +90 degree(s)C)
20 Weight 3.7 Kgs
21 Dimensions (WxHxD/mm) 185mm x 297mm x 90mm
22 Enclosure Pre-wired metal enclosure
23 Certification CE, ISO 9001 & ISO 14001
IEC 61643-11: 2011
IEC 62301: 2011
Standards & testing: IEC 61000-6-1:2016 (Protocol Fallowed as per IEC 61000-4-2: 2008, IEC 61000-4-4:2012, IEC
24 (All testes in Indian Govt. IEC/ NABL Accredited Laboratory) 61000-4-5:2014+A1:2017, IEC 61000-4-11:2020)
EC 61000-6-3:2020 & IEC 61000-6-1:2016 (Protocol followed as per, CISPR 16,IEC 61000-4-
3:2020, IEC 61000-4-6:2013 & IEC 61000-4-8:2009)
Technical Specification VKP-03
TECHNICAL SPECIFICATIONS FOR DIGITAL GROUNDING DEVICE VKP-03 STANDARD (THREE PHASE)
Sr No. Essential QRs Acceptable range
1 Rated input voltage 380-415 Volts, 3 Phase
2 Frequency 50 - 60 Hz
3 Maximum Continuous operating voltage (Uc) 275 Volts (L1-N, L2-N, L3-N), 255 Volts (N-G)
4 Maximum Surge Handling capacity 240 kA (8/20 micro seconds)
(3 Phase, 4 wire)
5 Mode of protection
(L1-N, L2-N, L3-N, L1-G, L2-G, L3-G & G-N
6 Maximum surge current (8/20µS) 40 kA each mode
7 Nominal discharge current (8/20µS) 10 kA each mode
8 Short circiut withstand current 10 kA
9 Residual current 0.001 amps
10 Residual voltage 1.59 kV (L-N) & 1.06 (N-G) with 8/20 micro sec.
11 Spark over voltage (8/20µS) 1.15 kV
12 Standby power consumption 3.87 W/hrs.
13 Impulse Response Time <25 Nano Second
14 Max. Leakage Current at 75% V₁mA , IL(µᴀ) 20µᴀ
15 Status indication LED indications
16 Reference Capacitance @1KhHz 1700 pF
17 Surge Conter 6 Digit, 7 Segment LCD counter
18 Communication Port RJ45 or 8 Pin Connector
19 Operating temperature (-40 degree(s)C ~ +90 degree(s)C)
20 Weight 3.7 Kgs
21 Dimensions (WxHxD/mm) 185mm x 297mm x 90mm
22 Enclosure Pre-wired metal enclosure
23 Certifications CE, ISO 9001 & ISO 14001
IEC 61643-11: 2011
IEC 62301: 2011
IEC 61000-6-1:2016 (Protocol Fallowed as per IEC 61000-4-2: 2008, IEC 61000-4-4:2012, IEC 61000-4-5:2014+A1:2017, IEC 61000-4-11:2020)
Standards & testing:
24 (All testes in Indian Govt. IEC/ NABL Accredited Laboratory)
EC 61000-6-3:2020 & IEC 61000-6-1:2016 (Protocol followed as per, CISPR 16,IEC 61000-4-3:2020, IEC 61000-4-6:2013 & IEC 61000-4-8:2009)
25 Testing and approvals (Indian Military Standard) MIL- STD: JSS 55555 - 2012 (Vibration, Shock, dry heat, dry cold, low temperature, High temperature, Sand & Dust)
Types of Lighting Surge Damages which clients want to
solve with Rasnal VKP
Equipment damage: component degradation
A. Accumulated shock of repeated surges cause a system to shut down
suddenly.
B. Cards frequently changed (damaged)
C. Faulty channel
D. Loss of circuit insulation
E. Shortening of component life span
F. Burn-out: system down / system failure
Electronic Equipment:
A. PCB damage
B. Data transmission error
C. Memory damage-Random system halt
D. Hard Disc damage
E. SCR ( Thyristor ) faulty
F. Process faulty
G. Program error (88.3% of unknown damages of electronic equipment are from
surges)
Communication Line / Signal Line:
A. Input / Output unit damage
B. Arc occurs at signal track
C. Unknown communication error, signal error
Operation Error:
A. Frequent ELCB/RCCB nuisance trip
B. System operation error
C. Unexpected output, reset, mode changes
Power Supply Unit Damage
A. Semiconductor component (SMPS) is easily damaged.
B. Surge pass through linear power supply unit, damage inner components.
C. DC power system trip (rectifier trip)
D. Power trip, power supply unit faulty
Difference between Digital Grounding System(DGS) &
Earthing
Sr. No. Parameter Rasnal VKP 01 / VKP 03 Chemical Earthing
(Digital Grounding System)
1 Function Analyses the quality of power and identify abnormal electrical characteristics and It is used to protect you from an electric shock. It does this by providing a path (a protective
eliminate the electric characteristics of surges by energy conversion such as heat & conductor) for a fault current to flow to earth. It also causes the protective device (either a
arc, neutralization there by neutralizing Surge & Noise from power supply. Not circuit-breaker or fuse) to switch off the electric current to the circuit that has the fault.
required to connect to a low impedance earthing.
2 Reverse Surge from Ground Since the surges and noise is eliminated using energy conversion technique protect Reverse flow of surge & lightning current through other connected grounding line may make
reverse attack by discharged current through earth wire. secondary damages
3 Earthing No need of Earthing Low impedance Earthing rod is required
4 Affect to other system No secondary affect, or affect to other system Discharged surge current from Earthing rod may make secondary damages to other systems
connected in that area.
5 Life Long life of up to 15 years Short life, due to corrosion and other damages
6 Installation Simple plug & play device Needs proper installation & digging work too
7 Application Sites with Needs a good soil with less resistivity to work properly
Earthing can not be done
Weak earthing conditions
Mobile equipment shelters
High earth to neutral voltage sites and high lightning prone areas
Total protection for connected equipment
8 Advantage Economic, scientific, protection from various external surges and lightning current No
without earthing.
9 Repeat use / Location Change Yes, can be relocated or reuse the device No repeat use of chemicals.
10 Use as a Mobile earth Yes, can be used in truck / vehicles No static use only
11 IEC Standards & Testing YES , IEC Tested Products No
IEC 61643-11: 2011, IEC 62301: 2011, IEC 61000-6-1:2016, EC 61000-6-3:2020
12
Testing and approvals as per Indian MIL- STD: JSS 55555 - 2012 (Vibration, Shock, dry heat, dry cold, low temperature,
No
Military Standard High temperature, Sand & Dust)
13 Size & Weight Compact size, light weight and easy to move Big Size, Heavy weight
14 Status indication LED indications No
15 Surge Counter 6 Digit, 7 Segment LCD counter Not available