SlideShare a Scribd company logo
LIQUID CHROMATOGRAPHY – MASS SPECTROMETRY
PRESENTED BY:
Bhavya K B
2nd Sem M pharma
Dept. of Pharm. Analysis
SAC College of pharmacy ,
B G Nagara .
PRESENTED TO:
Dr . T. Yunus pasha
Head of the department,
Dept. Of Pharm. Analysis
SAC College of pharmacy,
B G Nagara .
1
LIQUID CHROMATOGRAPHY –
MASS SPECTROMETRY.
(LC-MS)
2
CONTENT:
 Introduction
 Principle
 Instrumentation
 Applications
 Reference
3
INTRODUCTION:
LIQUID CHROMATOGROPHY – MASS SPECTROMETRY
 Liquid chromatography–mass spectrometry (LC-MS, or alternatively HPLC-MS)
is an ADVANCED ANALYTICAL INSTRUMNTAL technique that combines
the physical separation capabilities of LIQUID CHROMATOGRAPHY (or HPLC)
with the mass analysis capabilities of MASS SPECTROMETER
 Liquid chromatography tandem mass spectrometry (LC–MS), has led to major
breakthroughs in the field of quantitative bioanalysis since 1990s due to its
inherent specificity, sensitivity, and speed.
 It is now generally accepted as the preferred technique for quantitation of small
molecule drugs, metabolites in biological matrices (plasma, blood, serum, urine,
and tissue).
 In the most of the cases the interface used in LC-MS are ionization source. Which
provide structural information on the separated sample component.
4
Principle of LC-MS
 LC/MS combines the separating power of High Pressure liquid
chromatography (HPLC), with the detection power of mass spectrometry.
 It is combining the liquid chromatography with the mass spectrometry using
several types of interfaces in between,(which remove the solvent from the
column effluent and then bring the non- volatile and even thermally liable
analytes in gaseous form).
 In LC-MS we are removing the detector from the column of LC and fitting
the column to interface of MS.
 In the most of the cases the interface used in LC-MS are ionization source.
Which provide structural information on the separated sample component.
5
INSTRUMENTATION OF LC-MS
6
Neutral
samples
Inlet
INLET Form ion charged
molecules
Solid
Liquid
vapor
DATA
SYSTEM
Ionization
Source
Mass
Analyzer
Detector
Sort or separates
ions by M/Z
When ions strike
Detector it Detect ions
7
ION INTERFACE SOURCE:
The various interfaces differ among themselves in the means of
separating the analytes from the mobile phase and the method are
used for ionization of the analyte. The commonly used interfaces are :
(I ) Thermo spray ionization interfaces (TSI);
(ii) Particle beam ionization interface (PBI);
(ii) Atmospheric pressure chemical ionizations interface (APCI);
(iv) Electrospray ionization interface (ESI).
8
THERMOSPRAY IONIZATION INTERFACE:
 The effluent from the column [(usually containing an ammonium acetate buffer is
passed through a heated tube (300-400°C)] and rapidly expands as a jet spray into a
heated vacuum chamber where it forms supersonically a mist of electrically
charged droplets.
 The solvent is rapidly pumped away from the droplets to leave molecular ions such
as MH+ and MNH4+ by an ammonia chemical ionization process.
 The analyte ions with a static charge enter through a skimmer into the mass
spectrometer.
 Thermospray provides soft ionization with very small or no fragmentation.
 Thus the nonvolatile thermally labile organic compounds undergo gentle ionization
and the spectrum produced usually exhibits the protonated molecular ions.
9
Thermospray ionization interface:
1. Chromatographic effluent comes in
at - a,
2.The transfer line is suddenly heated
at -b
3.And the spray is formed under
vacuum at- c.
4.At - d the spray goes between a
pusher with a positive potential and a
negative cone for positive ions.
5. The ions are thus extracted from the
spray droplets and accelerated
towards the spectrometer.
6. At - e, a high-capacity pump
maintains the vacuum in HPLC-MS.
10
THERMOSPRAY IONIZATION
INTERFACE:
11
PARTICLE BEAM INTERFACE
 The mobile phase from the columns nebulized with helium gas to produce an aerosol in
a reduced pressure compartment at 70°C.
 A cone is provided with a small orifice at the end of the chamber and this leads the
mixture of He, solvent vapors, and analyte molecules after being accelerated into a low
pressure area (a two stage momentum separator)
 where it expands supersonically the He and solvent molecules are lighter than the solute
molecules and these diffuse out of the stream and are readily pumped away .
12
 now the relatively heavier solute molecules (having much greater momentum)
through a second cone are passed into a yet lower pressure area and then pass
straight through two skimmer plates along a narrow tube into the heated ionization
compartment.
 The particle beam interface provides electron ionization (EI) spectra and hence a
wide knowledge of such spectra is required for the compound identification.
 At present the TSI pressure and PBI have largely been replaced by systems usable
at atmospheric pressure.
13
PARTICLE BEAM INTERFACE
14
ATMOSPHERIC PRESSURE CHEMICAL
IONIZATION (APCI)
 In APCI, the LC eluent is sprayed through a heated [250-400] vaporizes at
atmospheric pressure.
 The heat vaporizes liquid which results gas solvent are ionized by corona needle
by which electrons are discharged.
 Thereby chemical reactions takes place and ions passes through a capillary orifice
into mass analyzer.
15
ATMOSPHERIC PRESSURE CHEMICAL
IONIZATION (APCI)
16
ELECTRO SPRAY IONIZATION INTERFACE
 This is most popular one and operates at the atmospheric pressure. This is also a
soft ionization technique.
 The sample solution is sprayed across a 3-6 KV potential from a metal capillary
tube into an orifice in the interface.
 They charged and appears in the form of the highly charged droplets.
 When the solvent evaporates, the drop shrinks, charge density is increased giving
rise to their explosive break up into the still smaller charged droplets.
 The process is repeated many times so as to produce a spray of ever smaller
droplets.
17
 As a consequence multiply-charged analyte species are produced. Such species
are passed through skimmers into the mass spectrometer and the uncharged
solvent molecules are pumped away.
 The characteristic and stability of such an spray depends upon the flow rate and
applied potential.
 Multiple charged sites are created on proteins and peptides and hence this permits
determination of a relatively large molecular weights > 3000 Dalton m/z ratio
limit of quadruple mass spectrometer ,
 as the m/z ratio decreases by a factor of 5, proteins of 50,000 Dalton or larger can
be monitored.
18
ELECTRO SPRAY IONIZATION
INTERFACE
19
MASS ANALYZER
 They deflects ions down a curved tubes in a magnetic fields based
on their kinetic energy determined by the mass, charge and velocity.
The magnetic field is scanned to measure different ions.
Its task is to separate ions in terms of their mass-to- charge
ratio and to direct the beam of focused ions to the detector.
The key performance parameters of an analyzer
include;
(a) separation efficiency
(b) m/z measurement precision
(c) range of the m/z valuesmeasured
20
Mass analyzers
Quadrupole Ion trap Time of flight
Fourier transformion
cyclotron resonance
21
QUADRUPOLE
 In a quadrupole mass analyzer a set of four
rods are arranged parallel to the direction.
Here a DC current and radio frequency RF
is applied to generate oscillating
electrostatic field in between the rods.
Based on this only m/z is been determined
and stable oscillation takes place. And ion
travels in quadrupole axis with cork screw
type of trajectory
22
TIME OF FLIGHT
 TOF mass analyzer is based on simple idea that the velocities of two ions are created by
uniform electromagnetic force applied to all the ions at same time, causing them to
accelerate down a flight tube.
 Lighter ions travels faster and strike the detector first so that the m/z ratio of ions is detected.
 The time-of-flight mass analyzer (TOF) consists of an ion accelerating grid and a flight tube
(about 1 m long), through which the ions travel to the detector.
 The analyzer separates ions accelerated by an electric field according to their velocity which
Depends on their mass and charges
23
ION TRAP MASS ANALYZER
The ion trap mass analyzer operates by similar principles
where it consists of circular ring electrode
Plus two end caps that form a chamber. Here AC or DC
power along RF potential is applied between the cups and
the ring electrode.
 There the ions entering into the chamber are trapped by
electromagnetic fields and they oscillates in concentric
trajectories. This process is called resonant ejection
 One of the most popular ion trap analyzers (IT) is the
quadrupole ion trap consisting of a ring-shaped electrode and
two electrodes with a spherical cross-section, with the space
between them forming a trap. The ion trap analyzer traps
ions with a specific mass-to-charge ratio by means of an
electricfield.
24
DETECTORS
 The detector is used to count the ions emergent from the mass analyzer, and may
also amplify the signal generatedfromeachion.Followingarethreedifferent kinds
of detectors are used in Mass Spectrometry
 Photographic plates
 Faraday cup
 Electron multiplier
 Channel electron multipliers
 Scintillation multiplier
25
Photo graphic plates
It is used as it is capable of higher resolution and speeder than
electronic devices. i.e. it can detect ions of all the masses and
providea reverse geometry analyzer.
26
FARADAY CUP
It is a metal cup into which all the ions are directed and
the signal produced is very stable and reproducible. It is
used on spectrometers where quantitative data is very
important
27
Electron multiplier
 In this the current can be measured so accurately by just one ion strikes the
detector can be measured i.e. when an ion strikes the surface of electron multiplier
two electron are ejected. This process continues until the end of electro multiplier
end is reached and electric current is analyzed and recordedwith electron
multiplier surface.
 Equation describe is 2n
 Where n= no of collisions with electron multiplier surface.
28
DATA HANDLING
 All the mass spectrometers now employ computer control of same functions
and also use a computerised display and output.
 The amount of data generated even by a fairly modest mass spectrometer is
very large indeed, a single run may store data for up to 100 fragments from each
type of molecule and if, LCMS analyses is being performed, a complete mass
spectrum is generated and stored every sec for up to 90 min
29
30
APPLICATION:
 Determination of impurities in insulin-like growth factor with
electrospray-
 mass spectrometry (ES-MS)ES-MS provides an excellent means
for quality control of recombinant proteins, some of which are now
used as drugs,
 e g. human insulin, interferons, erythropoietin and tissue
plasminogen activating factor.
 variations in protein structure, such as degree of glycosylation, or
in the terminal amino acids of the protein can be seen quite clearly
 An example of how ES-MS can be used to determine minor
impurities in a recombinant protein is shown in Figure 9.38, where
some small additional ions in the mass spectrum of recombinant
insulin-like growth factor (IGF) can be seen.
31
32
Characterization of a degradant of famotidine
 Tablets of famotidine, an anti-ulcer compound, were subjected to stress
conditioning pack.
 ' Figure 9.41 indicates the profile obtained from analysis of an extract from the
stressed tablets by LC atmospheric pressure chemical ionization mass
spectrometry (APCIMS).
 The structure of famotidine is shown in Figure 942.The mass spectra obtained for
famotidine and its degradant by APCIMS and APCIMS-MS are shown in Figures
9.43 and 9.44
 The degradant had a MW 12 amu higher than that of famotidine. The fragment at
m/z 189 was common to both spectra, indicating that the two molecules were
similar in structure.
33
34
35
36
Profiling impurities and degradants in
butorphanol tartrate
HPLC coupled to an ES-MS was used to elucidate the structure of a number of
degradants in butorphanol following its storage in aqueous solution Figure 9.45shows
the LC-MS profile of the degradants which were detected in butorphanol.
37
IDENTIFICATION OF BILE ACID METABOLITES:
 The use of in-vitro incubation of bile acid deoxycholic with rat liver microsomes to
stimulate metabolism of drug candidate. These precursor ions are were automatically
fragmented and full scan ion spectra is collected.
 The first graph shows the base peak chromatogram.(A)
 The second shows minor metabolite which is eluted at 9.41min.(B)
 Third graph show product spectrum from the ion at m/z 407 which confirms identity.(C)
38
39
4. Drug Development
Determinationof drugs and metabolites in plasma or other
biological fluids.
5.FOOD SCIENCE-melanin dosing. pesticide residues.
6. Life science.
7. Clinical science.
8. Forensic science.
40
REFERENCE
 David G. Watson, Pharmaceutical analysis, second edition, page no -207
 P. C. Kamboj. Pharmaceutical analysis, page no –212
 Beckett –Practical pharmaceutical chemistry, fourth edition. Part two
 Vogel’s - text book of quantitative chemical analysis. J. Mendham,
R, C, Denney.
41
42

More Related Content

PPTX
LIQUID CHROMATOGRAPHY-MASS SPECTROSCOPY (LC-MS)
PDF
GC -MS/MS and LC MS/MS
PPTX
PPTX
Capillary Electrophoresis-Mass Spectrometry
PPTX
GC MASS SPECTROMETERY
PPTX
LIQUID CHROMATOGRAPHY- MASS SPECTROSCOPY[LC-MS]
LIQUID CHROMATOGRAPHY-MASS SPECTROSCOPY (LC-MS)
GC -MS/MS and LC MS/MS
Capillary Electrophoresis-Mass Spectrometry
GC MASS SPECTROMETERY
LIQUID CHROMATOGRAPHY- MASS SPECTROSCOPY[LC-MS]

What's hot (20)

PPTX
Mass fragmentation & rules
PPTX
ria on digitalis
PPTX
C-13 NMR Spectroscopy
PPTX
Fragmentation rules mass spectroscopy
PPTX
CE-MS Hyphenation
PPTX
McLafferty Rearrangement.pptx
PPTX
Mass spectrometry and ionization techniques
PPT
PDF
Ionization Techniques In Mass Spectroscopy
PPTX
Spin spin coupling and decoupling
PPTX
Mass spectroscopy & it's instrumentations
PPTX
Mass spectroscopy
PPTX
NMR spcetroscopy
PPTX
Fragmentation of different functional groups
PPTX
Liquid chromatography nuclear magnetic resonance spectroscopy
PDF
Interpretation of organic compounds by IR, NMR and Mass Spectrometry
PPTX
Factors and applications of IR Spectroscopy
PPTX
LC NMR HYPHENATED TECHNIQUES
Mass fragmentation & rules
ria on digitalis
C-13 NMR Spectroscopy
Fragmentation rules mass spectroscopy
CE-MS Hyphenation
McLafferty Rearrangement.pptx
Mass spectrometry and ionization techniques
Ionization Techniques In Mass Spectroscopy
Spin spin coupling and decoupling
Mass spectroscopy & it's instrumentations
Mass spectroscopy
NMR spcetroscopy
Fragmentation of different functional groups
Liquid chromatography nuclear magnetic resonance spectroscopy
Interpretation of organic compounds by IR, NMR and Mass Spectrometry
Factors and applications of IR Spectroscopy
LC NMR HYPHENATED TECHNIQUES
Ad

Similar to LC- MS (20)

PPTX
Liquid Chromatography-Mass Spectrometry (LC-MS).pptx
PPTX
LC-MS, NMR, FTIR.pptx
PPTX
DOCX
liquid chromatography-mass spectrometry
PPTX
Lc -ms seminar
PPT
GC-MS.ppt
PPTX
PPTX
Methodology of targeted mass spectrometry
PPTX
Mass spectrometry
PPTX
Gas chromatography mass spectrometry
PDF
LCMS Final.pdf liquid chromatography and mass spectrometry
PPTX
Liquid chromatography–mass spectrometry (LC-MS) BY P. RAVISANKAR
PPTX
liquid chromatography - mass spectroscopy (LC-MS)
PDF
The principle and performance of liquid chromatography–mass spectrometry (LC-MS)
PPTX
Mass spectroscopy
PPTX
Mass spectrometry
PPT
PDF
05-BAT-Mass-Spec-Heena-1.pdf
PPTX
Liquid Chromatography-Mass Spectroscopy .pptx
PPTX
Liquid Chromatography-Mass Spectrometry (LC-MS).pptx
LC-MS, NMR, FTIR.pptx
liquid chromatography-mass spectrometry
Lc -ms seminar
GC-MS.ppt
Methodology of targeted mass spectrometry
Mass spectrometry
Gas chromatography mass spectrometry
LCMS Final.pdf liquid chromatography and mass spectrometry
Liquid chromatography–mass spectrometry (LC-MS) BY P. RAVISANKAR
liquid chromatography - mass spectroscopy (LC-MS)
The principle and performance of liquid chromatography–mass spectrometry (LC-MS)
Mass spectroscopy
Mass spectrometry
05-BAT-Mass-Spec-Heena-1.pdf
Liquid Chromatography-Mass Spectroscopy .pptx
Ad

More from Sri Adichunchanagiri College of Pharmacy (15)

PPTX
Journal Club Presentation.
PPTX
journal club presentation.pptx
PPTX
industrial production of vitamins
PPTX
SUPER CRITICAL FLUID CHROMATOGRAPHY
PPTX
Introduction to Fermentation, and production of penicillin and penicillin G
PPTX
McLaffertey rearrangement.
PPTX
Industrial production of statins
PPTX
REACTION PROGRESS KINETIC ANALYSIS
PPTX
GC-AAS Hyphenated Technique.
Journal Club Presentation.
journal club presentation.pptx
industrial production of vitamins
SUPER CRITICAL FLUID CHROMATOGRAPHY
Introduction to Fermentation, and production of penicillin and penicillin G
McLaffertey rearrangement.
Industrial production of statins
REACTION PROGRESS KINETIC ANALYSIS
GC-AAS Hyphenated Technique.

Recently uploaded (20)

PPTX
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
PDF
RTP_AR_KS1_Tutor's Guide_English [FOR REPRODUCTION].pdf
PDF
Classroom Observation Tools for Teachers
PPTX
Introduction-to-Literarature-and-Literary-Studies-week-Prelim-coverage.pptx
PDF
Computing-Curriculum for Schools in Ghana
PDF
RMMM.pdf make it easy to upload and study
PPTX
202450812 BayCHI UCSC-SV 20250812 v17.pptx
PDF
2.FourierTransform-ShortQuestionswithAnswers.pdf
PDF
Microbial disease of the cardiovascular and lymphatic systems
PDF
Trump Administration's workforce development strategy
PPTX
Lesson notes of climatology university.
PPTX
Cell Structure & Organelles in detailed.
PDF
O5-L3 Freight Transport Ops (International) V1.pdf
PDF
Chapter 2 Heredity, Prenatal Development, and Birth.pdf
PDF
STATICS OF THE RIGID BODIES Hibbelers.pdf
DOC
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PDF
Module 4: Burden of Disease Tutorial Slides S2 2025
PPTX
Pharma ospi slides which help in ospi learning
PDF
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
RTP_AR_KS1_Tutor's Guide_English [FOR REPRODUCTION].pdf
Classroom Observation Tools for Teachers
Introduction-to-Literarature-and-Literary-Studies-week-Prelim-coverage.pptx
Computing-Curriculum for Schools in Ghana
RMMM.pdf make it easy to upload and study
202450812 BayCHI UCSC-SV 20250812 v17.pptx
2.FourierTransform-ShortQuestionswithAnswers.pdf
Microbial disease of the cardiovascular and lymphatic systems
Trump Administration's workforce development strategy
Lesson notes of climatology university.
Cell Structure & Organelles in detailed.
O5-L3 Freight Transport Ops (International) V1.pdf
Chapter 2 Heredity, Prenatal Development, and Birth.pdf
STATICS OF THE RIGID BODIES Hibbelers.pdf
Soft-furnishing-By-Architect-A.F.M.Mohiuddin-Akhand.doc
Supply Chain Operations Speaking Notes -ICLT Program
Module 4: Burden of Disease Tutorial Slides S2 2025
Pharma ospi slides which help in ospi learning
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf

LC- MS

  • 1. LIQUID CHROMATOGRAPHY – MASS SPECTROMETRY PRESENTED BY: Bhavya K B 2nd Sem M pharma Dept. of Pharm. Analysis SAC College of pharmacy , B G Nagara . PRESENTED TO: Dr . T. Yunus pasha Head of the department, Dept. Of Pharm. Analysis SAC College of pharmacy, B G Nagara . 1
  • 2. LIQUID CHROMATOGRAPHY – MASS SPECTROMETRY. (LC-MS) 2
  • 3. CONTENT:  Introduction  Principle  Instrumentation  Applications  Reference 3
  • 4. INTRODUCTION: LIQUID CHROMATOGROPHY – MASS SPECTROMETRY  Liquid chromatography–mass spectrometry (LC-MS, or alternatively HPLC-MS) is an ADVANCED ANALYTICAL INSTRUMNTAL technique that combines the physical separation capabilities of LIQUID CHROMATOGRAPHY (or HPLC) with the mass analysis capabilities of MASS SPECTROMETER  Liquid chromatography tandem mass spectrometry (LC–MS), has led to major breakthroughs in the field of quantitative bioanalysis since 1990s due to its inherent specificity, sensitivity, and speed.  It is now generally accepted as the preferred technique for quantitation of small molecule drugs, metabolites in biological matrices (plasma, blood, serum, urine, and tissue).  In the most of the cases the interface used in LC-MS are ionization source. Which provide structural information on the separated sample component. 4
  • 5. Principle of LC-MS  LC/MS combines the separating power of High Pressure liquid chromatography (HPLC), with the detection power of mass spectrometry.  It is combining the liquid chromatography with the mass spectrometry using several types of interfaces in between,(which remove the solvent from the column effluent and then bring the non- volatile and even thermally liable analytes in gaseous form).  In LC-MS we are removing the detector from the column of LC and fitting the column to interface of MS.  In the most of the cases the interface used in LC-MS are ionization source. Which provide structural information on the separated sample component. 5
  • 7. Neutral samples Inlet INLET Form ion charged molecules Solid Liquid vapor DATA SYSTEM Ionization Source Mass Analyzer Detector Sort or separates ions by M/Z When ions strike Detector it Detect ions 7
  • 8. ION INTERFACE SOURCE: The various interfaces differ among themselves in the means of separating the analytes from the mobile phase and the method are used for ionization of the analyte. The commonly used interfaces are : (I ) Thermo spray ionization interfaces (TSI); (ii) Particle beam ionization interface (PBI); (ii) Atmospheric pressure chemical ionizations interface (APCI); (iv) Electrospray ionization interface (ESI). 8
  • 9. THERMOSPRAY IONIZATION INTERFACE:  The effluent from the column [(usually containing an ammonium acetate buffer is passed through a heated tube (300-400°C)] and rapidly expands as a jet spray into a heated vacuum chamber where it forms supersonically a mist of electrically charged droplets.  The solvent is rapidly pumped away from the droplets to leave molecular ions such as MH+ and MNH4+ by an ammonia chemical ionization process.  The analyte ions with a static charge enter through a skimmer into the mass spectrometer.  Thermospray provides soft ionization with very small or no fragmentation.  Thus the nonvolatile thermally labile organic compounds undergo gentle ionization and the spectrum produced usually exhibits the protonated molecular ions. 9
  • 10. Thermospray ionization interface: 1. Chromatographic effluent comes in at - a, 2.The transfer line is suddenly heated at -b 3.And the spray is formed under vacuum at- c. 4.At - d the spray goes between a pusher with a positive potential and a negative cone for positive ions. 5. The ions are thus extracted from the spray droplets and accelerated towards the spectrometer. 6. At - e, a high-capacity pump maintains the vacuum in HPLC-MS. 10
  • 12. PARTICLE BEAM INTERFACE  The mobile phase from the columns nebulized with helium gas to produce an aerosol in a reduced pressure compartment at 70°C.  A cone is provided with a small orifice at the end of the chamber and this leads the mixture of He, solvent vapors, and analyte molecules after being accelerated into a low pressure area (a two stage momentum separator)  where it expands supersonically the He and solvent molecules are lighter than the solute molecules and these diffuse out of the stream and are readily pumped away . 12
  • 13.  now the relatively heavier solute molecules (having much greater momentum) through a second cone are passed into a yet lower pressure area and then pass straight through two skimmer plates along a narrow tube into the heated ionization compartment.  The particle beam interface provides electron ionization (EI) spectra and hence a wide knowledge of such spectra is required for the compound identification.  At present the TSI pressure and PBI have largely been replaced by systems usable at atmospheric pressure. 13
  • 15. ATMOSPHERIC PRESSURE CHEMICAL IONIZATION (APCI)  In APCI, the LC eluent is sprayed through a heated [250-400] vaporizes at atmospheric pressure.  The heat vaporizes liquid which results gas solvent are ionized by corona needle by which electrons are discharged.  Thereby chemical reactions takes place and ions passes through a capillary orifice into mass analyzer. 15
  • 17. ELECTRO SPRAY IONIZATION INTERFACE  This is most popular one and operates at the atmospheric pressure. This is also a soft ionization technique.  The sample solution is sprayed across a 3-6 KV potential from a metal capillary tube into an orifice in the interface.  They charged and appears in the form of the highly charged droplets.  When the solvent evaporates, the drop shrinks, charge density is increased giving rise to their explosive break up into the still smaller charged droplets.  The process is repeated many times so as to produce a spray of ever smaller droplets. 17
  • 18.  As a consequence multiply-charged analyte species are produced. Such species are passed through skimmers into the mass spectrometer and the uncharged solvent molecules are pumped away.  The characteristic and stability of such an spray depends upon the flow rate and applied potential.  Multiple charged sites are created on proteins and peptides and hence this permits determination of a relatively large molecular weights > 3000 Dalton m/z ratio limit of quadruple mass spectrometer ,  as the m/z ratio decreases by a factor of 5, proteins of 50,000 Dalton or larger can be monitored. 18
  • 20. MASS ANALYZER  They deflects ions down a curved tubes in a magnetic fields based on their kinetic energy determined by the mass, charge and velocity. The magnetic field is scanned to measure different ions. Its task is to separate ions in terms of their mass-to- charge ratio and to direct the beam of focused ions to the detector. The key performance parameters of an analyzer include; (a) separation efficiency (b) m/z measurement precision (c) range of the m/z valuesmeasured 20
  • 21. Mass analyzers Quadrupole Ion trap Time of flight Fourier transformion cyclotron resonance 21
  • 22. QUADRUPOLE  In a quadrupole mass analyzer a set of four rods are arranged parallel to the direction. Here a DC current and radio frequency RF is applied to generate oscillating electrostatic field in between the rods. Based on this only m/z is been determined and stable oscillation takes place. And ion travels in quadrupole axis with cork screw type of trajectory 22
  • 23. TIME OF FLIGHT  TOF mass analyzer is based on simple idea that the velocities of two ions are created by uniform electromagnetic force applied to all the ions at same time, causing them to accelerate down a flight tube.  Lighter ions travels faster and strike the detector first so that the m/z ratio of ions is detected.  The time-of-flight mass analyzer (TOF) consists of an ion accelerating grid and a flight tube (about 1 m long), through which the ions travel to the detector.  The analyzer separates ions accelerated by an electric field according to their velocity which Depends on their mass and charges 23
  • 24. ION TRAP MASS ANALYZER The ion trap mass analyzer operates by similar principles where it consists of circular ring electrode Plus two end caps that form a chamber. Here AC or DC power along RF potential is applied between the cups and the ring electrode.  There the ions entering into the chamber are trapped by electromagnetic fields and they oscillates in concentric trajectories. This process is called resonant ejection  One of the most popular ion trap analyzers (IT) is the quadrupole ion trap consisting of a ring-shaped electrode and two electrodes with a spherical cross-section, with the space between them forming a trap. The ion trap analyzer traps ions with a specific mass-to-charge ratio by means of an electricfield. 24
  • 25. DETECTORS  The detector is used to count the ions emergent from the mass analyzer, and may also amplify the signal generatedfromeachion.Followingarethreedifferent kinds of detectors are used in Mass Spectrometry  Photographic plates  Faraday cup  Electron multiplier  Channel electron multipliers  Scintillation multiplier 25
  • 26. Photo graphic plates It is used as it is capable of higher resolution and speeder than electronic devices. i.e. it can detect ions of all the masses and providea reverse geometry analyzer. 26
  • 27. FARADAY CUP It is a metal cup into which all the ions are directed and the signal produced is very stable and reproducible. It is used on spectrometers where quantitative data is very important 27
  • 28. Electron multiplier  In this the current can be measured so accurately by just one ion strikes the detector can be measured i.e. when an ion strikes the surface of electron multiplier two electron are ejected. This process continues until the end of electro multiplier end is reached and electric current is analyzed and recordedwith electron multiplier surface.  Equation describe is 2n  Where n= no of collisions with electron multiplier surface. 28
  • 29. DATA HANDLING  All the mass spectrometers now employ computer control of same functions and also use a computerised display and output.  The amount of data generated even by a fairly modest mass spectrometer is very large indeed, a single run may store data for up to 100 fragments from each type of molecule and if, LCMS analyses is being performed, a complete mass spectrum is generated and stored every sec for up to 90 min 29
  • 30. 30
  • 31. APPLICATION:  Determination of impurities in insulin-like growth factor with electrospray-  mass spectrometry (ES-MS)ES-MS provides an excellent means for quality control of recombinant proteins, some of which are now used as drugs,  e g. human insulin, interferons, erythropoietin and tissue plasminogen activating factor.  variations in protein structure, such as degree of glycosylation, or in the terminal amino acids of the protein can be seen quite clearly  An example of how ES-MS can be used to determine minor impurities in a recombinant protein is shown in Figure 9.38, where some small additional ions in the mass spectrum of recombinant insulin-like growth factor (IGF) can be seen. 31
  • 32. 32
  • 33. Characterization of a degradant of famotidine  Tablets of famotidine, an anti-ulcer compound, were subjected to stress conditioning pack.  ' Figure 9.41 indicates the profile obtained from analysis of an extract from the stressed tablets by LC atmospheric pressure chemical ionization mass spectrometry (APCIMS).  The structure of famotidine is shown in Figure 942.The mass spectra obtained for famotidine and its degradant by APCIMS and APCIMS-MS are shown in Figures 9.43 and 9.44  The degradant had a MW 12 amu higher than that of famotidine. The fragment at m/z 189 was common to both spectra, indicating that the two molecules were similar in structure. 33
  • 34. 34
  • 35. 35
  • 36. 36
  • 37. Profiling impurities and degradants in butorphanol tartrate HPLC coupled to an ES-MS was used to elucidate the structure of a number of degradants in butorphanol following its storage in aqueous solution Figure 9.45shows the LC-MS profile of the degradants which were detected in butorphanol. 37
  • 38. IDENTIFICATION OF BILE ACID METABOLITES:  The use of in-vitro incubation of bile acid deoxycholic with rat liver microsomes to stimulate metabolism of drug candidate. These precursor ions are were automatically fragmented and full scan ion spectra is collected.  The first graph shows the base peak chromatogram.(A)  The second shows minor metabolite which is eluted at 9.41min.(B)  Third graph show product spectrum from the ion at m/z 407 which confirms identity.(C) 38
  • 39. 39
  • 40. 4. Drug Development Determinationof drugs and metabolites in plasma or other biological fluids. 5.FOOD SCIENCE-melanin dosing. pesticide residues. 6. Life science. 7. Clinical science. 8. Forensic science. 40
  • 41. REFERENCE  David G. Watson, Pharmaceutical analysis, second edition, page no -207  P. C. Kamboj. Pharmaceutical analysis, page no –212  Beckett –Practical pharmaceutical chemistry, fourth edition. Part two  Vogel’s - text book of quantitative chemical analysis. J. Mendham, R, C, Denney. 41
  • 42. 42