3
Most read
5
Most read
12
Most read
MKS Instruments
MultiGas 2030 FTIR




                MKS Instruments
           On-Line Product Group

                        Presented by:
                        Jim Belanger
            jim_belanger@mksinst.com
MultiGas 2030 Features
 Resolves & analyzes more compounds
   – 0.5 cm-1 high resolution FTIR

 Analysis in 1 second
   – (0.2 sec for HS version)
   – High speed FTIR

 Fastest response
   – Long path length, small
     volume gas cell
   – 5.11 m, 200 mL gas cell

 High speed detectors for all applications
   – TE or LN2 cooled MCT detectors
 No field adjustments required          Provides correction for
   – Permanently aligned spectrometer     pressure fluctuations
                                           – 0 – 1000 Torr cap.
                                             manometer
                                                        MKS Confidential   2
MultiGas Features, continued
 Maintains permanent calibration
   – Calibration supplied with instrument
                                          Instrument to Instrument Precision
   – Reduces need for gas cylinders
   – All instruments maintain same              Calibration - fixed
     calibration                                Sample
 Detection limits ppb to ppm
   – All with a single gas cell
 State-of-the-art spectral analysis
   – More than 30 compounds
     simultaneously
 Full instrument diagnostics
   – Quickly pinpoint instrument failure
   – Demonstrates instrument compliance       Carbon Monoxide Spectrum



                                                               MKS Confidential   3
MultiGas 2030
Hardware Overview
MultiGas 2030 - Top View
               Heated Cell        Electronics




Detector Box       Baratron pressure        Heated Gas inlet
                     measurement
                                                  MKS Confidential   5
MultiGas Cell Advantage
                                      20/20 Gas Cell
                                        – 5.11 m, 200 mL volume
                                        – 32 passes through cell
                                        – Long path - small volume
                                          -->provides fast response
                                        – Versions
                                             Ni-coated Al cell
                                             Ni-coated Stainless Steel
20/20TM Long Path (5.11m) Gas Cell           Nickeless Stainless Steel
                                        – Alignment indexing pads
                                      Mirrors
                                        – O-ring “face” seal
                                             Kalrez, Viton, Metal
                                        – Corrosive resistant coating
                                        – High light throughput
                                      Windows
                                       – KBr, MgF2-KBr, BaF2, CaF2


                                                           MKS Confidential   6
2 cm Gas Cell




 Used for %-level analysis in particular for SynGas Reactions
 255 times less sensitive then 5m gas cell
                                                                MKS Confidential   7
MG2030 MCT Detectors
 LN2 Cooled Detectors
   – Larger Range:
       Greater number of detectable species
       500 cm-1 cut off (16μ)
   – High Sensitivity: Lower minimum level of detection
   – Maintenance
       12 hour coolant refill require
       3-5 days coolant refill with 5L extended dewar



 TE Cooled Detectors
   – Narrow Range:
       Smaller number of detectable species
       2000 cm-1 (5μ), 1350 cm-1 (7.4μ) or 1100 cm-1 (9.2μ)
   – Highest Sensitivity - 2000 cm-1 (5μ),
       Lowest minimum level of detection
       Unable to detect species such as NH3
   – Maintenance - None
                                                               MKS Confidential   8
MG2030 Detectors

 MG2030 offers MCT Detectors
  – 5 micron – 16 micron detector ranges
  – Selection depends on gas/sensitivity/range
    required


              Detector Sensitivity Comparison
                             Cooling                    Sensitivity    Comparison to
 DETECTOR        Range                   Coolant
                              Temp                         (D*)          16u LN2
               5000 - 2000             Piezo electric
  5 micron                    -80° C                     77.1 e9      1.8x more sensitive
                  cm-1                 element (TE)
               5000 - 1350             Piezo electric
 7.4 micron                   -80° C                      6.9 e9       6x less sensitive
                  cm-1                 element (TE)
               5000 - 1100             Piezo electric
  9 micron                    -80° C                      2.3 e9      18x less sensitive
                  cm-1                 element (TE)
               5000 - 500                Liquid N2
  16 micron                  -196° C                     42.8 e9          Base value
                  cm-1

                                                                           MKS Confidential   9
Instrument Spectral Accuracy

 Instrument Accuracy Optimization
   – Spectra linearity
           Accurate absorbance in the whole range of
            absorbance level
    – Resolution
           Instrument has same resolution (i.e., line width) as
            the calibration spectra
    – Line position
           Instrument spectra are “lining up” exactly with the
            calibration spectra
 Validation
   – Use transferrable calibration and verify cal cylinder
   – Still need H2O Calibration on each instrument for CEM
   – Remove influences from components like CO2 and H2O



                                                             MKS Confidential   10
Field Analysis Using FTIR
 Monitoring VOCs
   –   CH4 ranges from 500 up to 3000 ppm
   –   C2H6 in the hundreds of ppm
   –   Propane on the order of 50 ppm and below
   –   Need to speciate to remove Methane and Ethane
   –   Unburned Propane largest VOC contribution after catalyst

 Monitoring HAPs
   – Formaldehyde easy to measure by FTIR

 Conventional Total Hydrocarbon (THC) analyzers
   – Can not separate Propane from Methane or Ethane
   – Use Methane Analyzer then subtracts the rest – Not sensitive
   – Unable to detect all HCs (e.g. formaldehyde)


                                                         MKS Confidential   11
Field Deployable FTIR

 Advantages
  – Multiple species – one instrument
         SO2, NH3, NO, HCl, HF, CO, CO2, H2O, and VOCs
   – Analyze components in high CO2 and H2O
   – Direct analysis – no chemical conversion or “fudge
     factors”
   – Analysis method minimizes interferents
   – Flexibility in Changing in Method
         Customer can easily modify
         Transferable calibrations



                                                MKS Confidential   12
How Can MKS OLT Support You?
 MKS On-Line Products
   – Dedicated to your gas analysis success
 Numerous Applications
   – Compliance
   – Engineering
   – Ambient air
 Support Resources
   – MKS Applications Team
   – MKS Field Services Team
   – Outside Applications Team
 Industry Standard Technology
   – Field proven rugged FTIR analyzer
   – Industry leading software and analysis algorithms
 Financing Assistance Available
   – Capital partners


                                                         MKS Confidential   13
Thank You!

More Related Content

DOCX
Days of elijah lyrics
PDF
Energy sources jb
PPTX
UNFCCC
PDF
Method for HCL Monitoring by FTIR Analysis
PPTX
Metformin & glipizide microspheres
PDF
X-Max brochure v2 (current)
PPTX
Low-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 Monitoring
PDF
2015_Mead_Patrick_Design_Portfolio_PCB
Days of elijah lyrics
Energy sources jb
UNFCCC
Method for HCL Monitoring by FTIR Analysis
Metformin & glipizide microspheres
X-Max brochure v2 (current)
Low-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 Monitoring
2015_Mead_Patrick_Design_Portfolio_PCB

Similar to MultiGas 2030 General Overview (20)

PDF
Cylinder Sensor Brochure
PDF
Rgs8000 datasheet
PDF
App139 en measurement-carbon-brush-wear-electric-motors
PPTX
Ultrasonic level
PDF
Catalog thiết bị báo mức Kansai Automation
PDF
FTIR Spectrometer
PPTX
Zigbee based intelligent helemet for coal miners ppt
PPTX
MCE 2016 - M. Roncoroni - INFICON
PPT
6020Lpresentaaaaaaaaaaaaaaaaaddaation.ppt
PDF
App025 en diameter-radial-axial-runout-measurement-disk-motors
PDF
Introduction of 7200 Q-TOF.pdf
PPT
Laser Science Services (I) Pvt. Ltd
PDF
Product_overview_2014_150
PDF
Narda news 25 2017_11_e
PPTX
Tc klinger magnetic level gauge principles and application rev 2 c
PDF
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
PDF
App074 en deformation-brake-disc-under-stress
PDF
Track 1 session 7 - st dev con 2016 - smart cities
PPTX
HPLC Detectors
PPTX
Pulp and Paper industry-sensors
Cylinder Sensor Brochure
Rgs8000 datasheet
App139 en measurement-carbon-brush-wear-electric-motors
Ultrasonic level
Catalog thiết bị báo mức Kansai Automation
FTIR Spectrometer
Zigbee based intelligent helemet for coal miners ppt
MCE 2016 - M. Roncoroni - INFICON
6020Lpresentaaaaaaaaaaaaaaaaaddaation.ppt
App025 en diameter-radial-axial-runout-measurement-disk-motors
Introduction of 7200 Q-TOF.pdf
Laser Science Services (I) Pvt. Ltd
Product_overview_2014_150
Narda news 25 2017_11_e
Tc klinger magnetic level gauge principles and application rev 2 c
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
App074 en deformation-brake-disc-under-stress
Track 1 session 7 - st dev con 2016 - smart cities
HPLC Detectors
Pulp and Paper industry-sensors
Ad

MultiGas 2030 General Overview

  • 1. MKS Instruments MultiGas 2030 FTIR MKS Instruments On-Line Product Group Presented by: Jim Belanger [email protected]
  • 2. MultiGas 2030 Features  Resolves & analyzes more compounds – 0.5 cm-1 high resolution FTIR  Analysis in 1 second – (0.2 sec for HS version) – High speed FTIR  Fastest response – Long path length, small volume gas cell – 5.11 m, 200 mL gas cell  High speed detectors for all applications – TE or LN2 cooled MCT detectors  No field adjustments required  Provides correction for – Permanently aligned spectrometer pressure fluctuations – 0 – 1000 Torr cap. manometer MKS Confidential 2
  • 3. MultiGas Features, continued  Maintains permanent calibration – Calibration supplied with instrument Instrument to Instrument Precision – Reduces need for gas cylinders – All instruments maintain same Calibration - fixed calibration Sample  Detection limits ppb to ppm – All with a single gas cell  State-of-the-art spectral analysis – More than 30 compounds simultaneously  Full instrument diagnostics – Quickly pinpoint instrument failure – Demonstrates instrument compliance Carbon Monoxide Spectrum MKS Confidential 3
  • 5. MultiGas 2030 - Top View Heated Cell Electronics Detector Box Baratron pressure Heated Gas inlet measurement MKS Confidential 5
  • 6. MultiGas Cell Advantage  20/20 Gas Cell – 5.11 m, 200 mL volume – 32 passes through cell – Long path - small volume -->provides fast response – Versions  Ni-coated Al cell  Ni-coated Stainless Steel 20/20TM Long Path (5.11m) Gas Cell  Nickeless Stainless Steel – Alignment indexing pads  Mirrors – O-ring “face” seal  Kalrez, Viton, Metal – Corrosive resistant coating – High light throughput  Windows – KBr, MgF2-KBr, BaF2, CaF2 MKS Confidential 6
  • 7. 2 cm Gas Cell Used for %-level analysis in particular for SynGas Reactions 255 times less sensitive then 5m gas cell MKS Confidential 7
  • 8. MG2030 MCT Detectors  LN2 Cooled Detectors – Larger Range:  Greater number of detectable species  500 cm-1 cut off (16μ) – High Sensitivity: Lower minimum level of detection – Maintenance  12 hour coolant refill require  3-5 days coolant refill with 5L extended dewar  TE Cooled Detectors – Narrow Range:  Smaller number of detectable species  2000 cm-1 (5μ), 1350 cm-1 (7.4μ) or 1100 cm-1 (9.2μ) – Highest Sensitivity - 2000 cm-1 (5μ),  Lowest minimum level of detection  Unable to detect species such as NH3 – Maintenance - None MKS Confidential 8
  • 9. MG2030 Detectors  MG2030 offers MCT Detectors – 5 micron – 16 micron detector ranges – Selection depends on gas/sensitivity/range required Detector Sensitivity Comparison Cooling Sensitivity Comparison to DETECTOR Range Coolant Temp (D*) 16u LN2 5000 - 2000 Piezo electric 5 micron -80° C 77.1 e9 1.8x more sensitive cm-1 element (TE) 5000 - 1350 Piezo electric 7.4 micron -80° C 6.9 e9 6x less sensitive cm-1 element (TE) 5000 - 1100 Piezo electric 9 micron -80° C 2.3 e9 18x less sensitive cm-1 element (TE) 5000 - 500 Liquid N2 16 micron -196° C 42.8 e9 Base value cm-1 MKS Confidential 9
  • 10. Instrument Spectral Accuracy  Instrument Accuracy Optimization – Spectra linearity  Accurate absorbance in the whole range of absorbance level – Resolution  Instrument has same resolution (i.e., line width) as the calibration spectra – Line position  Instrument spectra are “lining up” exactly with the calibration spectra  Validation – Use transferrable calibration and verify cal cylinder – Still need H2O Calibration on each instrument for CEM – Remove influences from components like CO2 and H2O MKS Confidential 10
  • 11. Field Analysis Using FTIR  Monitoring VOCs – CH4 ranges from 500 up to 3000 ppm – C2H6 in the hundreds of ppm – Propane on the order of 50 ppm and below – Need to speciate to remove Methane and Ethane – Unburned Propane largest VOC contribution after catalyst  Monitoring HAPs – Formaldehyde easy to measure by FTIR  Conventional Total Hydrocarbon (THC) analyzers – Can not separate Propane from Methane or Ethane – Use Methane Analyzer then subtracts the rest – Not sensitive – Unable to detect all HCs (e.g. formaldehyde) MKS Confidential 11
  • 12. Field Deployable FTIR  Advantages – Multiple species – one instrument  SO2, NH3, NO, HCl, HF, CO, CO2, H2O, and VOCs – Analyze components in high CO2 and H2O – Direct analysis – no chemical conversion or “fudge factors” – Analysis method minimizes interferents – Flexibility in Changing in Method  Customer can easily modify  Transferable calibrations MKS Confidential 12
  • 13. How Can MKS OLT Support You?  MKS On-Line Products – Dedicated to your gas analysis success  Numerous Applications – Compliance – Engineering – Ambient air  Support Resources – MKS Applications Team – MKS Field Services Team – Outside Applications Team  Industry Standard Technology – Field proven rugged FTIR analyzer – Industry leading software and analysis algorithms  Financing Assistance Available – Capital partners MKS Confidential 13