L A B O R A T O R Y S O L U T I O N S
Fully automated sample preparation
The ThinPrep® 5000 is capable of processing up to 20
gynaecological, general cytology or UroCyte™ samples per batch.
Processes slides
utilising Controlled
Membrane Transfer™
(CMT) for a randomised,
representative thin-layer
presentation
Ref: INT-08-003 Rev. B
© 2008 Hologic Inc. All rights reserved.
Specifications subject to change without notice.
References:
1. Cytyc Corporation, The ThinPrep® Pap Test
package insert.
Lab Workflow
Patient Name
1234
1234
1234
ThinPrep®
Slide
1234
ThinPrep®
Slide
Patient Name Patient Name
1234
1234
1234
Specifications
For full product details and purchasing
enquiries please contact:
ThinPrep® 5000 Processor
Instrument Dimensions Width: 86 cm/34”, Height: 56 cm/22”,
Depth: 66 cm/26”
Weight 80 kg/175 lb (approx.)
Waste container Width: 15 cm/6”, Height: 43 cm/17”,
Depth: 15 cm/6”
Operating Temperature 16 – 32°C / 60 - 90°F
Operating Humidity 20% – 80% RH non-condensing
Electrical Voltage 100/130 VAC at 2 amps
220/240 VAC at 1 amp
Frequency 47 – 63 Hz
Power Maximum 240 watts
Clearances Width: 94 cm/37”, Height: 109 cm/43”,
Depth: 74 cm/29”
56 cm
(22”)
66 cm
(26”)
86 cm
(34”)
I
The ThinPrep Pap
Test Sample Vial and
Request Form arrive
at the laboratory
I
Corresponding labels
containing unique ID
numbers are placed
on the Sample Vial,
the slide and the Test
Request Form
I
The Sample Vials
and matching slides
are loaded into the
input carousel for
processing
I
Case report form and
slide are paired by the
sample ID numbers
and forwarded to the
cytotechnologist
I
The ThinPrep 5000
Processor reads the
barcode from the
Sample Vial and
matches this with
the ID number on the
slide. Once a match
is confirmed, the
sample is processed
The ThinPrep® 5000 Processor utilises
proven ThinPrep technology for cell
dispersion, collection and transfer.
• The ThinPrep vial is spun
creating currents that are:
- Strong enough to separate
debris and mucus, and
randomise cells
- Gentle enough to have no
adverse effect on cell
appearance
• The ThinPrep Pap Test Filter is
inserted into the sample vial
• A gentle vacuum is created
within the ThinPrep Pap Test
Filter
• Cells are collected on the
exterior surface of the
membrane
• Cell collection is controlled by
the ThinPrep 5000 Processor
software that monitors the rate
of flow through the ThinPrep
Pap Test Filter
• Following cell collection on the
membrane, the ThinPrep Pap
Test Filter is inverted then gently
pressed against the ThinPrep
Microscope slide to create a
20 mm defined circular area
• Natural attraction with computer
controlled mechanical positioning
and positive air pressure causes
the cells to adhere to the
ThinPrep Microscope slide
resulting in an even distribution
of cells in a defined circular area
Dispersion: Cell Collection: Cell Transfer:
1 2 3
Features
• Chain-of-custody verification eliminates possibility
for sample mix-up
- Instrument matches the barcode on vial with
the label on slide to ensure sample is placed
on correct slide
• User friendly, easy to operate
• Walk away automation
• Able to process between 1 and 20 samples per
batch allowing flexible walk away automation
• Supports processing of multiple slides per vial
• Automated vial handling enables operator to
simply load and leave
• Batch processing may be interrupted in order
to run an urgent sample
Throughput:
• Batch of 20 samples processed
in approximately 35 minutes
– Up to 35 slides per hour
– 280 slides per day
– 60,000 slides per year
* with a single 8 hour shift

14804874665T5_brochure.pdf

  • 1.
    L A BO R A T O R Y S O L U T I O N S Fully automated sample preparation The ThinPrep® 5000 is capable of processing up to 20 gynaecological, general cytology or UroCyte™ samples per batch. Processes slides utilising Controlled Membrane Transfer™ (CMT) for a randomised, representative thin-layer presentation Ref: INT-08-003 Rev. B © 2008 Hologic Inc. All rights reserved. Specifications subject to change without notice. References: 1. Cytyc Corporation, The ThinPrep® Pap Test package insert. Lab Workflow Patient Name 1234 1234 1234 ThinPrep® Slide 1234 ThinPrep® Slide Patient Name Patient Name 1234 1234 1234 Specifications For full product details and purchasing enquiries please contact: ThinPrep® 5000 Processor Instrument Dimensions Width: 86 cm/34”, Height: 56 cm/22”, Depth: 66 cm/26” Weight 80 kg/175 lb (approx.) Waste container Width: 15 cm/6”, Height: 43 cm/17”, Depth: 15 cm/6” Operating Temperature 16 – 32°C / 60 - 90°F Operating Humidity 20% – 80% RH non-condensing Electrical Voltage 100/130 VAC at 2 amps 220/240 VAC at 1 amp Frequency 47 – 63 Hz Power Maximum 240 watts Clearances Width: 94 cm/37”, Height: 109 cm/43”, Depth: 74 cm/29” 56 cm (22”) 66 cm (26”) 86 cm (34”) I The ThinPrep Pap Test Sample Vial and Request Form arrive at the laboratory I Corresponding labels containing unique ID numbers are placed on the Sample Vial, the slide and the Test Request Form I The Sample Vials and matching slides are loaded into the input carousel for processing I Case report form and slide are paired by the sample ID numbers and forwarded to the cytotechnologist I The ThinPrep 5000 Processor reads the barcode from the Sample Vial and matches this with the ID number on the slide. Once a match is confirmed, the sample is processed
  • 2.
    The ThinPrep® 5000Processor utilises proven ThinPrep technology for cell dispersion, collection and transfer. • The ThinPrep vial is spun creating currents that are: - Strong enough to separate debris and mucus, and randomise cells - Gentle enough to have no adverse effect on cell appearance • The ThinPrep Pap Test Filter is inserted into the sample vial • A gentle vacuum is created within the ThinPrep Pap Test Filter • Cells are collected on the exterior surface of the membrane • Cell collection is controlled by the ThinPrep 5000 Processor software that monitors the rate of flow through the ThinPrep Pap Test Filter • Following cell collection on the membrane, the ThinPrep Pap Test Filter is inverted then gently pressed against the ThinPrep Microscope slide to create a 20 mm defined circular area • Natural attraction with computer controlled mechanical positioning and positive air pressure causes the cells to adhere to the ThinPrep Microscope slide resulting in an even distribution of cells in a defined circular area Dispersion: Cell Collection: Cell Transfer: 1 2 3 Features • Chain-of-custody verification eliminates possibility for sample mix-up - Instrument matches the barcode on vial with the label on slide to ensure sample is placed on correct slide • User friendly, easy to operate • Walk away automation • Able to process between 1 and 20 samples per batch allowing flexible walk away automation • Supports processing of multiple slides per vial • Automated vial handling enables operator to simply load and leave • Batch processing may be interrupted in order to run an urgent sample Throughput: • Batch of 20 samples processed in approximately 35 minutes – Up to 35 slides per hour – 280 slides per day – 60,000 slides per year * with a single 8 hour shift