AIR HANDLING UNIT
PRASANTH M
THERMAL(R AND AC)
1
AIR HANDLING UNIT
An AHU used to
Circulate
Distribute and
Regulate the conditioned air for HVAC
buildings
2
AIR HANDLING UNIT
3
1 – Supply duct
2 – Fan compartment
3 – Vibration isolator ('flex joint')
4 – Heating and/or cooling coil
5 – Filter compartment
6 – Mixed (recirculated + outside) air duct
COMPONENTS OF AHU
Supply duct
Supply conditioned air for various heat loads
Fan compartment
Pressurize air to compensate pressure drop in
duct
Vibration isolater
Dampens the vibration in the unit caused by
dynamic equipments
4
Heating/cooling coil
Controls the temperature and humidity to the
required level
Filter compartment
Filters the particulate matters to the required
standards
Mixing air duct
Mixes return air with required amount of
fresh air
5
AHU FOR INDOOR APPLICATIONS
39MN UNIT SIZE
UNIT CASING
H (in.) W (in.)
03 37 33
06 37 46
08 40 54
10 40 67
12 47 67
14 47 72
17 50 79
21 60 79
25 60 86
30 60 104
36 71 109
40 77 109
50 87 117
61 102 117
72 113 120
85 113 139
96 126 139
110 126 157
6
AHU FOR OUTDOOR UNIT
39MW UNIT SIZE
UNIT CASING
H (in.) W (in.)
03 41 36
06 41 49
08 44 57
10 44 70
12 51 70
14 51 75
17 54 82
21 64 82
25 64 89
30 64 107
36 75 112
40 81 112
50 91 120
61 106 120
72 117 123
85 117 142
96 130 142
110 130 160
7
ENERGY EFFICIENT MOTOR
Motors that gives same output by consuming
lesser energy compared to standard motors
8
NEED
When there is a new installation or
modification to your plant
Old motors are damaged and need rewinding
Existing motors are underloaded or
overloaded
Protecting other devices
9
EFFICIENCY
10
ENERGY EFFICIENT MOTORS USED IN
AHU
Brushless dc motor
11
ADVANTAGES
12
Operate more satisfactorily under abnormal
voltage
Electric power saving
Operating temperature is less
Noise level is lower

Air handling unit

  • 1.
    AIR HANDLING UNIT PRASANTHM THERMAL(R AND AC) 1
  • 2.
    AIR HANDLING UNIT AnAHU used to Circulate Distribute and Regulate the conditioned air for HVAC buildings 2
  • 3.
    AIR HANDLING UNIT 3 1– Supply duct 2 – Fan compartment 3 – Vibration isolator ('flex joint') 4 – Heating and/or cooling coil 5 – Filter compartment 6 – Mixed (recirculated + outside) air duct
  • 4.
    COMPONENTS OF AHU Supplyduct Supply conditioned air for various heat loads Fan compartment Pressurize air to compensate pressure drop in duct Vibration isolater Dampens the vibration in the unit caused by dynamic equipments 4
  • 5.
    Heating/cooling coil Controls thetemperature and humidity to the required level Filter compartment Filters the particulate matters to the required standards Mixing air duct Mixes return air with required amount of fresh air 5
  • 6.
    AHU FOR INDOORAPPLICATIONS 39MN UNIT SIZE UNIT CASING H (in.) W (in.) 03 37 33 06 37 46 08 40 54 10 40 67 12 47 67 14 47 72 17 50 79 21 60 79 25 60 86 30 60 104 36 71 109 40 77 109 50 87 117 61 102 117 72 113 120 85 113 139 96 126 139 110 126 157 6
  • 7.
    AHU FOR OUTDOORUNIT 39MW UNIT SIZE UNIT CASING H (in.) W (in.) 03 41 36 06 41 49 08 44 57 10 44 70 12 51 70 14 51 75 17 54 82 21 64 82 25 64 89 30 64 107 36 75 112 40 81 112 50 91 120 61 106 120 72 117 123 85 117 142 96 130 142 110 130 160 7
  • 8.
    ENERGY EFFICIENT MOTOR Motorsthat gives same output by consuming lesser energy compared to standard motors 8
  • 9.
    NEED When there isa new installation or modification to your plant Old motors are damaged and need rewinding Existing motors are underloaded or overloaded Protecting other devices 9
  • 10.
  • 11.
    ENERGY EFFICIENT MOTORSUSED IN AHU Brushless dc motor 11
  • 12.
    ADVANTAGES 12 Operate more satisfactorilyunder abnormal voltage Electric power saving Operating temperature is less Noise level is lower