Simulation of HRSG stack exhaust gas and its influence on nearby
structure under varying wind conditions
For this case, R&R Consult assisted Aalborg Engineering with a plant
for Siemens in Malta. We simulated the flow behaviour of hot exhaust
gas from a heat recovery steam generator (HRSG) as it was ejected
from a by-pass exhaust stack. The CFD simulation investigated the
flow and temperature field of ejected exhaust gas — specifically,
whether it could compromise the nearby main exhaust duct during
worst-case wind conditions. This could pose a problem for the
electronic equipment installed at the main exhaust duct. The main
objective was to evaluate the heating of the main exhaust duct in
case strong winds carried the by-pass exhaust gas towards it. During
the simulation, we recreated the behaviour of hot exhaust gas ejected
10 m/s wind speed
15 m/s wind speed 20 m/s wind speed
The setup was evaluated at
various wind speeds, HRSG
operating loads, and exhaust gas
temperatures. The results
mapped the height at which by-
pass exhaust gas might come into
contact with the main exhaust
duct, and determined peak
temperatures on the outer surface
of the main exhaust duct. With
this information, we quantified the
potential risk of damaging
equipment, given a worst-case
scenario combination of
operating- and ambient
conditions.
at high altitude and the influence of buoyancy
forces, temperature-dependent density and
external wind conditions.
Front Side Back Side
Gasværksvej 26, DK 9000 Aalborg www.R-R-Consult.com www.LinkedIn.com/company/R&R-consult Info@R-R-consult.com
Simulation of HRSG stack exhaust gas and its influence on nearby
structure under varying wind conditions

CFD simulation of hrsg stack exhaust gas and its influence on nearby structure under varying wind conditions

  • 1.
    Gasværksvej 26, DK9000 Aalborg www.R-R-Consult.com www.LinkedIn.com/company/R&R-consult [email protected] Simulation of HRSG stack exhaust gas and its influence on nearby structure under varying wind conditions
  • 2.
    For this case,R&R Consult assisted Aalborg Engineering with a plant for Siemens in Malta. We simulated the flow behaviour of hot exhaust gas from a heat recovery steam generator (HRSG) as it was ejected from a by-pass exhaust stack. The CFD simulation investigated the flow and temperature field of ejected exhaust gas — specifically, whether it could compromise the nearby main exhaust duct during worst-case wind conditions. This could pose a problem for the electronic equipment installed at the main exhaust duct. The main objective was to evaluate the heating of the main exhaust duct in case strong winds carried the by-pass exhaust gas towards it. During the simulation, we recreated the behaviour of hot exhaust gas ejected 10 m/s wind speed 15 m/s wind speed 20 m/s wind speed The setup was evaluated at various wind speeds, HRSG operating loads, and exhaust gas temperatures. The results mapped the height at which by- pass exhaust gas might come into contact with the main exhaust duct, and determined peak temperatures on the outer surface of the main exhaust duct. With this information, we quantified the potential risk of damaging equipment, given a worst-case scenario combination of operating- and ambient conditions. at high altitude and the influence of buoyancy forces, temperature-dependent density and external wind conditions. Front Side Back Side Gasværksvej 26, DK 9000 Aalborg www.R-R-Consult.com www.LinkedIn.com/company/R&R-consult [email protected] Simulation of HRSG stack exhaust gas and its influence on nearby structure under varying wind conditions