The document summarizes the design of a concrete foundation column to support a steel column for a new fire testing facility. Key aspects of the design include:
1) The pedestal will be 500x500 to adequately support the 450x450 steel base plate.
2) The pedestal is designed as a small column with 8-25mm diameter reinforcing bars spaced at 28mm on each face and 10mm diameter ties spaced at 400mm.
3) The 1200mm square spread footing is sized to permit the 900mm development length of the vertical bars and have a minimum 150mm cover over the footing.
4) The factored ultimate bearing resistance of the soil is 480kPa based on the