                     FlexGuard 5853 Wireless Glassbreak Detector Installation Instructions
                          Refer to Supplemental Information (next page) for complete descriptions of these installation steps
5853 Glassbreak Detector Internal Parts                                                                                                                                                                    Test Detector Installation
                                                                                                                                                                                                           Enter Test Mode using a FlexGuard FG-701
                                                                                                                                                                                                           Glassbreak Simulator (see Testing the Detector on the
                                                                                                                                                                                                           next page). To enter Test Mode manually, short the
                          Latch                                                                                                                                                                            Test Mode pads (as shown below).
                  Mounting Hole
   Front Tamper Switch
            Microphone
 Wall Tamper (behind battery)                          2
                                                           1
                                                               OFF


                                                               ON




    Sensitivity Switches                   CR-123A
                                             CR-123A




                                                                                                                                                                                                                                                             SENS1
                                                                                                                                                                                                                                                             SENS2
                                                                                                                                  Ceiling Mount: (Side View)
                    Batteries                                                                                                                                                    CeilingMnt-001-V0




                                                                                                                                                                                                                  CR-123A

                                                                                                                                                                                                                            CR-123A
                                                                                                                                                                                                                                      SENS1
                                                                                                                                                                                                                                      SENS2
   Test Mode pads (on PCB)
                                                                                      NOTE: If the device is ceiling mounted, the end with the
                  Mounting Hole                                                                                                                                                                                                       TEST




                                                                                      hole (Microphone end) should face the protected glass.
                  LED Indicators                                                                                                                                                                                                                            TEST




                                                                                                                                                                                                                                              5853_005-v0
                                                                                      Set Sensitivity (Range)                                                                                              Install Cover Screw (optional)


                    Front Cover                                                                                                                                                       ON                                                                     2.9
                                                                                                                                                                                                                                                                 m
                                                                                                                                                                                                                                                             6 m m (#4)
                                                                                                                                                                                                                                                                 m (1      s
                                                                                                                                                                                                                                                                      /4-in crew,
                                                                                                                                                                                                                                                                           .) lo
                                                                                                                                                                                                                                                                                 ng
                                                                                                                                                                                      OFF
                                                                                                          CR-123A

                                                                                                                            CR-123A
                                                                                                                                      SENS1
                                                                                                                                      SENS2
    5853_001-v0




                      Break out flash




                                                                                                                                                                                         SENS1
                                                                                                                                                                                         SENS2
                      for cover screw
                                                                                       5853_004-v0




Connect Batteries
Remove pull tab to connect batteries
                                                                                      SENS1 & SENS2 configure sensitivity
                                                                                          SENSITIVITY                                   APPROXIMATE                   SENS1                   SENS2
                                                                                                                                           RANGE
                                                                                                         MAX                                   7.6m (25 ft)              OFF                   OFF
                                                                                                     MEDIUM                                    4.6m (15 ft)               ON                   OFF
                                                                                                         LOW                                     3m (10 ft)              OFF                    ON
                                                                                                     LOWEST                                     1.5m (5 ft)               ON                    ON


                                                                                      NOTE: Ranges are approximate and vary with each
                                                                                      room’s acoustic properties. Always verify range with a
                                                                                      FlexGuard FG-701 Glassbreak Simulator.


                                                                                      Enroll Detector                                                                                                                                                                5853_006-V1


                                                                                      Refer to text and control panel's installation
                                                                                      instructions.
                                                                                      When programming the transmitter, specify:
                                                                                                     •    Input Type = 3 (Supervised RF)
                                                                                                     •    Loop Number = 1


Select Mounting Location                                                              Mount Detector
For the best detector performance, select a mounting                                                 •    Use mounting holes as a template to mark
location that is:                                                                                         mounting locations on ceiling or wall.
   • within 7.6 m (25 feet) of the protected glass;                                                  •    If using the optional back tamper, remove the
   • within clear view of the protected glass;                                                            batteries, then mark the wall tamper location
                                                                                                          through its mounting hole.
   • at least 2 m (6.5 feet) from the floor;
                                                                                                     •    Mount detector using appropriate hardware.
   • at least 1 m (3.3 feet) from forced air ducts;
                                                                                                          NOTE: A screw capture feature designed to
   • at least 1 m (3.3 feet) from sirens or bells greater                                                 make ceiling mounting easier will cause some
   • than 5 cm (2 inches) in diameter.                                                                    resistance when inserting the screw into the
   • between the protected glass and any heavy                                                            plastic.
       window coverings that may be present.                                                         •    Close detector cover when finished.
Alternatively, when heavy window coverings are
present, the detector can be mounted on the frame
of the window.
Avoid mounting the detector on the same wall as the
                                                                                                                                                                                    CR-123A




                                                                                      3.5 mm x 38 mm
                                                                                        (#6 x 1-1/2")
protected glass, on free-standing posts or pillars, or in
rooms with noisy equipment (air compressors, bells,                                      *3.5 mm (#6)
                                                                                      screws works best
power tools, etc.), if this equipment is operated when                                  with the screw
                                                                                                                                              CR-123A


                                                                                                                                                              SENS1
                                                                                                                                                              SENS2




                                                                                       retention feature.                                                               #6 (3.5 mm) screw for
the detector is armed.                                                                                                                                                  Optional Rear Tamper




                                                                                                                                                                           (Screw not supplied.)
                                                                                                                                                                      To work properly, the back tamper
                                                                                       3.5 mm x 38 mm
                                                                                         (#6 x 1-1/2")                                                                screw must be screwed into a
                                        Wall Mount                                                                                                                    framing stud or a heavy-duty
                                         (Top View)                                                                                                                   hollow-wall anchor, such as a
                                                                                                                                                                      #8 self-tapping anchor. This type
                                                                                                                    5853_003-v2




                                                                                                                                                                      of back tamper is not suitable for
                                                                                                                                                                      use on acoustic ceiling tile.



                                                                                      *The screw retention feature simplifies installation: A
                                                                                      rib in the screw cavity lightly holds the screw in place
                                                                                      when installing the detector.
                                                                     WallMnt-001-V0




5-051-735-00G                                                                                                                                           Page 1
®
            FlexGuard 5853 Wireless Glassbreak Detector Supplemental Information
                              Refer to Installation Instructions and diagrams (next page) when installing this product
1. General Information                                               6. Mounting the Detector                                                8. LED Indicators
The 5853 Wireless Glassbreak detector with                           NOTE: If using wall tamper and installing on dry wall                   The detector is equipped with two LEDs: a green Event
Transmitter senses the sound of breaking plate,                      (sheet rock), position the detector so that the wall                    LED and a red Alarm LED. When the LEDs are
tempered, laminated, wired, coated and sealed                        tamper is over a wall stud or ceiling joist, or use a                   enabled during testing, they light in a variety of patterns
insulating glass. The self-contained detector includes               drywall anchor so the tamper screw will not pull out.                   to convey the detector’s operational status. The
a transmitter that can send alarms, tamper signals, and                                                                                      following table summarizes the LED messages.
low battery messages to the control panel. The                       NOTE: If the device is ceiling mounted, the end with                    (Please note that the LEDs are only enabled during
sensor is compatible with 5800-series wireless                       the hole (Microphone end) should face the protected                     Test Mode, and are inactive during normal operation.)
hardware*, and is designed for continuous operation                  glass.
                                                                                                                                         CONDITION                              GREEN LED                      RED LED
using two 3V lithium batteries (CR-123A or equivalent;               To mount the detector:
included).                                                                                                                               Power up                               ON 1 second                    ON 1 second
                                                                         1. Using the 5853 mounting holes as a template,
                                                                                                                                         Test Mode                              Flash once per sec             OFF
Prior to installation, you must:                                            mark mounting locations on the ceiling or wall.
                                                                                                                                         Test Mode, event detected              Flicker                        OFF
     •    Connect its batteries by removing the tab,                     2. If using the optional wall tamper, remove
                                                                            the batteries, then mark the wall tamper                     Test Mode, alarm                       Flash once per sec             ON 5 seconds
     •    Adjust the detector’s sensitivity, and
                                                                            location through its mounting hole. The                      Low Battery *                          Flash once per sec             Flash once per sec
     •    “Enroll” the detector’s serial number.                            tamper screw must be securely mounted. See                       * If battery voltage drops too low, LEDs are no longer visible.
Refer to the following sections to install the 5853.                        details on page 1.
                                                                         3. If required by the mounting location, install                    9. Cover Screw
This detector is both UL and ULC listed.
                                                                            wall anchors for the mounting screws.
                                                                                                                                             The front cover can be secured after installation. To do
*Compatible control units for use in Canada require the use of           4. Secure the 5853 to the wall or ceiling,
listed RF receivers that have been subjected to compatibility
                                                                                                                                             so, remove the cover breakout flash (illustration on next
                                                                            oriented so the microphone has the best line-                    page) and secure the front cover with a 6 mm (¼-in.), 2.9
analyses by Underwriters’ Laboratories of Canada. Refer to the              of-sight to the protected glass.
Installation Instructions for the control unit before installing                                                                             mm (#4) screw (supplied).
burglar alarm components.                                                5. Reinstall the batteries if previously removed.
                                                                         6. Close and secure the detector front cover.                       10. Maintaining Proper Operation
2. Connecting Batteries/Initial Power Up                                                                                                     To maintain the 5853 Glassbreak Detector in proper
To connect the batteries, remove the tab from the end                7. Testing the Detector                                                 working order, please observe the following:
of the battery holder. The detector will start its power             The detector should be tested at least once each year.                  Replace the batteries when the system indicates a low
up sequence, in which both the LED indicators will                   Test the detector with the FlexGuard FG-701 Glassbreak                  battery condition (refer to the control panel’s operating
illuminate for one second. (The LED indicators are                   Simulator. Other simulators will not give accurate                      instructions.) Be sure to replace the batteries with the
described later in these instructions.)                              indication of range.                                                    proper type and voltage, and ALWAYS replace both
                                                                     To enter the Test Mode with the FG-701:                                 batteries at the same time.
3. Adjusting Detector Sensitivity (Range)                                                                                                    The installer should inform the end user that fans, air
                                                                         1. Stand within 4.6 m (15 feet) of the detector.
The 5853 has four sensitivity settings, which are set                                                                                        conditioners, blowers, loudspeakers, or other sources
                                                                         2. Switch the FG-701 to ACTIVATE and MANual                         of vibration and sound should not be introduced into
using the SENS1 and SENS2 DIP switches. The
                                                                             modes.                                                          the protected area after installation of glassbreak
settings are: 1) maximum; 2) medium; 3) low; and 4)
lowest. By default, sensitivity is set to MAXIMUM.                       3. Point the front [speaker] of the glassbreak                      detectors. If unavoidable, the end user must contact
                                                                             simulator towards the detector and press the                    the alarm service company to re-adjust/re-test the
To change the detector’s sensitivity, use a small                            red START button. The simulator buzzes a                        equipment as needed. Additionally, this device should
screwdriver to adjust the SENS1 and SENS2 switches,                          short activation code.                                          not be relocated without the advice or assistance of the
as shown in the table below:
                                                                     When the detector enters Test Mode, the green LED                       alarm service company.
 SENSITIVITY           APPROX.           SENS1       SENS2
                                                                     on the detector flashes about once per second. If the
                        RANGE
                                                                     green LED does not flash, move closer to the detector                   11. Protected Glass Types Chart
     MAX              7.6m (25 ft)        OFF          OFF           and repeat the procedure.                                               NOTE: The 5853 is NOT recommended for protection of glass areas
   MEDIUM             4.6m (15 ft)         ON          OFF                                                                                   smaller than 27.6 cm x 27.6 cm (10-7/8 inches x 10-7/8 inches).
                                                                     To enter Test Mode manually:                                                                               Nominal Thickness
     LOW               3m (10 ft)         OFF          ON
                                                                         1. Open the front cover.                                               Glass Type*           Minimum                 Maximum
   LOWEST              1.5m (5 ft)         ON          ON                2. Use a screwdriver to short the Test Mode                          Plate                         2mm (3/32 in.)                10mm (3/8 in.)
                                                                             pads on the PC board (see diagram on next                        Tempered                      3mm (1/8 in.)                 10mm (3/8 in.)
                                                                             page).
4. Enrolling Detector Into 5800-Series Receiver                                                                                               Laminated1, 3                 3mm (1/8 in.)                 14mm (9/16 in.)
                                                                         3. Close the front cover.                                            Wired                         6mm (1/4 in.)                 6mm (1/4 in.)
Before the control panel will recognize the 5853, you
must program the device's serial number into the                     The detector’s green LED blinks approximately once per                   Coated 2, 3                   3mm (1/8 in.)                 6mm (1/4 in.)
control panel. This process, ("enrolling") is described              second to indicate that it has entered the test mode.
                                                                                                                                              Sealed Insulating1, 3         3mm (1/8 in.) [13mm           6mm (1/4 in.) [19mm
in detail in the control panel's installation instructions.                                                                                                                 (1/2 in.) overall]            (3/4 in.) overall]
                                                                     Testing the Detector (flex and audio signals):
When programming the transmitter, specify:                           To test the 5853, do the following:                                 * Minimum size for all types is 28cm (11 in.) square; glass must be
    •     Input Type = 3 (Supervised RF)                                   1. Place the detector in Test Mode.                           1
                                                                                                                                           framed in the wall or mounted in a barrier at least 0.9m (36 in.) wide.
                                                                                                                                           Protected only if both plates in the unit are broken
    •     Loop Number = 1                                                  2. Set the FG-701 switches to the TEST and                    2
                                                                                                                                           Coated glass with security films up to 0.35mm (14 mils) thick (including films
You can transmit the device’s serial number                                    FLEX positions.                                             for solar protection) may be used. Evaluated with the these products: 3M
                                                                                                                                                                                                                        ®

                                                                                                                                                               ®
automatically or enter it manually. To transmit the                                                                                        SCOTCHSHIELD SH14CLARL – 0.35mm (14 mils), 4 ply film; Film
                                                                           3. Position the FG-701 near the farthest point of               Technologies International, Inc.’s GLASS-GARD GGLL 1200 has been
number automatically, momentarily activate the front                           the protected glass, and point the speaker                  evaluated with this product by Underwriters Laboratories, Inc.
tamper switch. To enter the serial number manually,                            directly at the detector. If window coverings             3
                                                                                                                                           In compliance with Underwriters Laboratories of Canada’s Standard for
refer to the control panel’s instructions to enroll the                        are present, close them fully and hold the                  Intrusion Detection Units (CAN/ULC-S306-M89):
serial ID number which appears on the product.                                 FG-701 between the coverings and the                        a. Plate glass 3mm (1/8-in.) to 10mm (3/8-in.) can be used.
                                                                                                                                           b. ULC recognizes a maximum range for protecting sealed insulating glass,
                                                                               protected glass.                                               1/8” laminated and coated glass of 3.8m (12.5 ft.); sensitivity should be set
5. Selecting Installation Location                                         4. Press the red START button. The simulator                        to Max.

The 5853 can be mounted on the ceiling or the wall.                            clicks on and starts an eight-second armed
Choose a mounting location that is at least 2.1m (7                            period.                                                       12. Specifications
feet) from floor and no more than 7.6m (25 feet) from                      5. Generate a flex signal by carefully striking the               Power: Two 3 V Batteries (included). Replace only with
the farthest protected glass. Be sure the detector has                         glass with a cushioned tool. The FG-701                       ADEMCO #466, Panasonic CR123A, Sanyo CR123A, Duracell
                                                                               responds with a burst of glassbreak audio.                    DL123A, or Varta CR123A (Lithium Manganese Dioxide)
an unobstructed line-of-sight to the protected glass!
                                                                     If the detector receives both the flex and audio signals                Ranges: Maximum range is 7.6m (25 ft) from farthest
Before mounting the detector permanently, test it to                                                                                         protected glass. No minimum range.
ensure that it functions satisfactorily in the chosen                properly, its red Alarm LED lights for 5 seconds. (Red
                                                                     Alarm LED does not latch.)                                              Operating Temperature: -10° to 50° C (14° to 122° F)
mounting location. Verify that the detector can detect                                                                                       For indoor use environment
glassbreak sounds, following the directions in the                   Testing the Detector (audio signals only):
“Testing the Detector” section. Ensure that the 5853 is                                                                                      Dimensions: 12.5cm (4.95") x 7.8cm (3.09") x 2.8cm (1.1")
within range of the receiver, following the instructions             The FG-701 can also be used to test the detector’s
                                                                                                                                             Weight: 146g (5.12 oz.)
for the signal-strength test found in the control panel’s            ability to receive audio signals only. See the FG-701
                                                                     Operating Instructions for additional information. When                 Accessories: FlexGuard FG-701 Glassbreak Simulator
installation instructions. (To send the signal required
by the test, activate the detector's front tamper switch.)           it receives the audio signal, the detector flickers its                 Compliance: FCC and IC Verified, UL Listed, ULC Listed, C-Tick
If the detector fails, relocate it and repeat both tests.            green Event LED.

                                                                     Exiting Test Mode:
                                                                                                                                             13. NOTICES
                                                                                                                                             FCC NOTICE This device complies with Part 15 of the FCC rules and RSS 210
                                                                     When you have finished testing, exit Test Mode by                       of Industry Canada. Operation is subject to the following two conditions: (1) This
                                                                     following the same procedure used to enter Test Mode.                   device may not cause harmful interference, and (2) this device must accept any
                                                                                                                                             interference received, including interference that may cause undesired operation.
                                                                     The detector automatically exits Test Mode five minutes                 Unauthorized changes or modifications could void the user's authority to operate the
                                                                     after the last event is detected.                                       equipment.
                                                                                                                                             TO THE INSTALLER
                                                                                                                                             Regular maintenance and inspection (at least annually) by the installer and frequent
                                                                                                                                             testing by the user are vital to continuous satisfactory operation of any alarm system.
                                                                                                                                             The installer should assume the responsibility of developing and offering a regular
                                                                                                                                             maintenance program to the user as well as acquainting the user with the proper
                                                                                                                                             operation and limitations of the alarm system and its component parts.
                                                                                                                                             Recommendations must be included for a specific program of testing (at least
                                                                                                                                             weekly) to ensure the system’s proper operation at all times.
                                                                                                                                             REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/ CONTROL
                                                                                                                                             WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING WARRANTY
                                                                                                                                             INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.




                                                                   ©2002 Honeywell International Inc. All Rights Reserved                                                                                     Made in China
                                                                   Honeywell, FlexGuard and IntelliSense are registered trademarks of Honeywell
                                                                   International Inc. - All other brands mentioned are the trademarks or registered trademarks
                                                                   of their respective owners. Specifications subject to change without prior notice.                                          P/N 5-051-735-00 Rev G

Honeywell 5853-install-guide

  • 1.
    ® FlexGuard 5853 Wireless Glassbreak Detector Installation Instructions Refer to Supplemental Information (next page) for complete descriptions of these installation steps 5853 Glassbreak Detector Internal Parts Test Detector Installation Enter Test Mode using a FlexGuard FG-701 Glassbreak Simulator (see Testing the Detector on the next page). To enter Test Mode manually, short the Latch Test Mode pads (as shown below). Mounting Hole Front Tamper Switch Microphone Wall Tamper (behind battery) 2 1 OFF ON Sensitivity Switches CR-123A CR-123A SENS1 SENS2 Ceiling Mount: (Side View) Batteries CeilingMnt-001-V0 CR-123A CR-123A SENS1 SENS2 Test Mode pads (on PCB) NOTE: If the device is ceiling mounted, the end with the Mounting Hole TEST hole (Microphone end) should face the protected glass. LED Indicators TEST 5853_005-v0 Set Sensitivity (Range) Install Cover Screw (optional) Front Cover ON 2.9 m 6 m m (#4) m (1 s /4-in crew, .) lo ng OFF CR-123A CR-123A SENS1 SENS2 5853_001-v0 Break out flash SENS1 SENS2 for cover screw 5853_004-v0 Connect Batteries Remove pull tab to connect batteries SENS1 & SENS2 configure sensitivity SENSITIVITY APPROXIMATE SENS1 SENS2 RANGE MAX 7.6m (25 ft) OFF OFF MEDIUM 4.6m (15 ft) ON OFF LOW 3m (10 ft) OFF ON LOWEST 1.5m (5 ft) ON ON NOTE: Ranges are approximate and vary with each room’s acoustic properties. Always verify range with a FlexGuard FG-701 Glassbreak Simulator. Enroll Detector 5853_006-V1 Refer to text and control panel's installation instructions. When programming the transmitter, specify: • Input Type = 3 (Supervised RF) • Loop Number = 1 Select Mounting Location Mount Detector For the best detector performance, select a mounting • Use mounting holes as a template to mark location that is: mounting locations on ceiling or wall. • within 7.6 m (25 feet) of the protected glass; • If using the optional back tamper, remove the • within clear view of the protected glass; batteries, then mark the wall tamper location through its mounting hole. • at least 2 m (6.5 feet) from the floor; • Mount detector using appropriate hardware. • at least 1 m (3.3 feet) from forced air ducts; NOTE: A screw capture feature designed to • at least 1 m (3.3 feet) from sirens or bells greater make ceiling mounting easier will cause some • than 5 cm (2 inches) in diameter. resistance when inserting the screw into the • between the protected glass and any heavy plastic. window coverings that may be present. • Close detector cover when finished. Alternatively, when heavy window coverings are present, the detector can be mounted on the frame of the window. Avoid mounting the detector on the same wall as the CR-123A 3.5 mm x 38 mm (#6 x 1-1/2") protected glass, on free-standing posts or pillars, or in rooms with noisy equipment (air compressors, bells, *3.5 mm (#6) screws works best power tools, etc.), if this equipment is operated when with the screw CR-123A SENS1 SENS2 retention feature. #6 (3.5 mm) screw for the detector is armed. Optional Rear Tamper (Screw not supplied.) To work properly, the back tamper 3.5 mm x 38 mm (#6 x 1-1/2") screw must be screwed into a Wall Mount framing stud or a heavy-duty (Top View) hollow-wall anchor, such as a #8 self-tapping anchor. This type 5853_003-v2 of back tamper is not suitable for use on acoustic ceiling tile. *The screw retention feature simplifies installation: A rib in the screw cavity lightly holds the screw in place when installing the detector. WallMnt-001-V0 5-051-735-00G Page 1
  • 2.
    ® FlexGuard 5853 Wireless Glassbreak Detector Supplemental Information Refer to Installation Instructions and diagrams (next page) when installing this product 1. General Information 6. Mounting the Detector 8. LED Indicators The 5853 Wireless Glassbreak detector with NOTE: If using wall tamper and installing on dry wall The detector is equipped with two LEDs: a green Event Transmitter senses the sound of breaking plate, (sheet rock), position the detector so that the wall LED and a red Alarm LED. When the LEDs are tempered, laminated, wired, coated and sealed tamper is over a wall stud or ceiling joist, or use a enabled during testing, they light in a variety of patterns insulating glass. The self-contained detector includes drywall anchor so the tamper screw will not pull out. to convey the detector’s operational status. The a transmitter that can send alarms, tamper signals, and following table summarizes the LED messages. low battery messages to the control panel. The NOTE: If the device is ceiling mounted, the end with (Please note that the LEDs are only enabled during sensor is compatible with 5800-series wireless the hole (Microphone end) should face the protected Test Mode, and are inactive during normal operation.) hardware*, and is designed for continuous operation glass. CONDITION GREEN LED RED LED using two 3V lithium batteries (CR-123A or equivalent; To mount the detector: included). Power up ON 1 second ON 1 second 1. Using the 5853 mounting holes as a template, Test Mode Flash once per sec OFF Prior to installation, you must: mark mounting locations on the ceiling or wall. Test Mode, event detected Flicker OFF • Connect its batteries by removing the tab, 2. If using the optional wall tamper, remove the batteries, then mark the wall tamper Test Mode, alarm Flash once per sec ON 5 seconds • Adjust the detector’s sensitivity, and location through its mounting hole. The Low Battery * Flash once per sec Flash once per sec • “Enroll” the detector’s serial number. tamper screw must be securely mounted. See * If battery voltage drops too low, LEDs are no longer visible. Refer to the following sections to install the 5853. details on page 1. 3. If required by the mounting location, install 9. Cover Screw This detector is both UL and ULC listed. wall anchors for the mounting screws. The front cover can be secured after installation. To do *Compatible control units for use in Canada require the use of 4. Secure the 5853 to the wall or ceiling, listed RF receivers that have been subjected to compatibility so, remove the cover breakout flash (illustration on next oriented so the microphone has the best line- page) and secure the front cover with a 6 mm (¼-in.), 2.9 analyses by Underwriters’ Laboratories of Canada. Refer to the of-sight to the protected glass. Installation Instructions for the control unit before installing mm (#4) screw (supplied). burglar alarm components. 5. Reinstall the batteries if previously removed. 6. Close and secure the detector front cover. 10. Maintaining Proper Operation 2. Connecting Batteries/Initial Power Up To maintain the 5853 Glassbreak Detector in proper To connect the batteries, remove the tab from the end 7. Testing the Detector working order, please observe the following: of the battery holder. The detector will start its power The detector should be tested at least once each year. Replace the batteries when the system indicates a low up sequence, in which both the LED indicators will Test the detector with the FlexGuard FG-701 Glassbreak battery condition (refer to the control panel’s operating illuminate for one second. (The LED indicators are Simulator. Other simulators will not give accurate instructions.) Be sure to replace the batteries with the described later in these instructions.) indication of range. proper type and voltage, and ALWAYS replace both To enter the Test Mode with the FG-701: batteries at the same time. 3. Adjusting Detector Sensitivity (Range) The installer should inform the end user that fans, air 1. Stand within 4.6 m (15 feet) of the detector. The 5853 has four sensitivity settings, which are set conditioners, blowers, loudspeakers, or other sources 2. Switch the FG-701 to ACTIVATE and MANual of vibration and sound should not be introduced into using the SENS1 and SENS2 DIP switches. The modes. the protected area after installation of glassbreak settings are: 1) maximum; 2) medium; 3) low; and 4) lowest. By default, sensitivity is set to MAXIMUM. 3. Point the front [speaker] of the glassbreak detectors. If unavoidable, the end user must contact simulator towards the detector and press the the alarm service company to re-adjust/re-test the To change the detector’s sensitivity, use a small red START button. The simulator buzzes a equipment as needed. Additionally, this device should screwdriver to adjust the SENS1 and SENS2 switches, short activation code. not be relocated without the advice or assistance of the as shown in the table below: When the detector enters Test Mode, the green LED alarm service company. SENSITIVITY APPROX. SENS1 SENS2 on the detector flashes about once per second. If the RANGE green LED does not flash, move closer to the detector 11. Protected Glass Types Chart MAX 7.6m (25 ft) OFF OFF and repeat the procedure. NOTE: The 5853 is NOT recommended for protection of glass areas MEDIUM 4.6m (15 ft) ON OFF smaller than 27.6 cm x 27.6 cm (10-7/8 inches x 10-7/8 inches). To enter Test Mode manually: Nominal Thickness LOW 3m (10 ft) OFF ON 1. Open the front cover. Glass Type* Minimum Maximum LOWEST 1.5m (5 ft) ON ON 2. Use a screwdriver to short the Test Mode Plate 2mm (3/32 in.) 10mm (3/8 in.) pads on the PC board (see diagram on next Tempered 3mm (1/8 in.) 10mm (3/8 in.) page). 4. Enrolling Detector Into 5800-Series Receiver Laminated1, 3 3mm (1/8 in.) 14mm (9/16 in.) 3. Close the front cover. Wired 6mm (1/4 in.) 6mm (1/4 in.) Before the control panel will recognize the 5853, you must program the device's serial number into the The detector’s green LED blinks approximately once per Coated 2, 3 3mm (1/8 in.) 6mm (1/4 in.) control panel. This process, ("enrolling") is described second to indicate that it has entered the test mode. Sealed Insulating1, 3 3mm (1/8 in.) [13mm 6mm (1/4 in.) [19mm in detail in the control panel's installation instructions. (1/2 in.) overall] (3/4 in.) overall] Testing the Detector (flex and audio signals): When programming the transmitter, specify: To test the 5853, do the following: * Minimum size for all types is 28cm (11 in.) square; glass must be • Input Type = 3 (Supervised RF) 1. Place the detector in Test Mode. 1 framed in the wall or mounted in a barrier at least 0.9m (36 in.) wide. Protected only if both plates in the unit are broken • Loop Number = 1 2. Set the FG-701 switches to the TEST and 2 Coated glass with security films up to 0.35mm (14 mils) thick (including films You can transmit the device’s serial number FLEX positions. for solar protection) may be used. Evaluated with the these products: 3M ® ® automatically or enter it manually. To transmit the SCOTCHSHIELD SH14CLARL – 0.35mm (14 mils), 4 ply film; Film 3. Position the FG-701 near the farthest point of Technologies International, Inc.’s GLASS-GARD GGLL 1200 has been number automatically, momentarily activate the front the protected glass, and point the speaker evaluated with this product by Underwriters Laboratories, Inc. tamper switch. To enter the serial number manually, directly at the detector. If window coverings 3 In compliance with Underwriters Laboratories of Canada’s Standard for refer to the control panel’s instructions to enroll the are present, close them fully and hold the Intrusion Detection Units (CAN/ULC-S306-M89): serial ID number which appears on the product. FG-701 between the coverings and the a. Plate glass 3mm (1/8-in.) to 10mm (3/8-in.) can be used. b. ULC recognizes a maximum range for protecting sealed insulating glass, protected glass. 1/8” laminated and coated glass of 3.8m (12.5 ft.); sensitivity should be set 5. Selecting Installation Location 4. Press the red START button. The simulator to Max. The 5853 can be mounted on the ceiling or the wall. clicks on and starts an eight-second armed Choose a mounting location that is at least 2.1m (7 period. 12. Specifications feet) from floor and no more than 7.6m (25 feet) from 5. Generate a flex signal by carefully striking the Power: Two 3 V Batteries (included). Replace only with the farthest protected glass. Be sure the detector has glass with a cushioned tool. The FG-701 ADEMCO #466, Panasonic CR123A, Sanyo CR123A, Duracell responds with a burst of glassbreak audio. DL123A, or Varta CR123A (Lithium Manganese Dioxide) an unobstructed line-of-sight to the protected glass! If the detector receives both the flex and audio signals Ranges: Maximum range is 7.6m (25 ft) from farthest Before mounting the detector permanently, test it to protected glass. No minimum range. ensure that it functions satisfactorily in the chosen properly, its red Alarm LED lights for 5 seconds. (Red Alarm LED does not latch.) Operating Temperature: -10° to 50° C (14° to 122° F) mounting location. Verify that the detector can detect For indoor use environment glassbreak sounds, following the directions in the Testing the Detector (audio signals only): “Testing the Detector” section. Ensure that the 5853 is Dimensions: 12.5cm (4.95") x 7.8cm (3.09") x 2.8cm (1.1") within range of the receiver, following the instructions The FG-701 can also be used to test the detector’s Weight: 146g (5.12 oz.) for the signal-strength test found in the control panel’s ability to receive audio signals only. See the FG-701 Operating Instructions for additional information. When Accessories: FlexGuard FG-701 Glassbreak Simulator installation instructions. (To send the signal required by the test, activate the detector's front tamper switch.) it receives the audio signal, the detector flickers its Compliance: FCC and IC Verified, UL Listed, ULC Listed, C-Tick If the detector fails, relocate it and repeat both tests. green Event LED. Exiting Test Mode: 13. NOTICES FCC NOTICE This device complies with Part 15 of the FCC rules and RSS 210 When you have finished testing, exit Test Mode by of Industry Canada. Operation is subject to the following two conditions: (1) This following the same procedure used to enter Test Mode. device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The detector automatically exits Test Mode five minutes Unauthorized changes or modifications could void the user's authority to operate the after the last event is detected. equipment. TO THE INSTALLER Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of testing (at least weekly) to ensure the system’s proper operation at all times. REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/ CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. ©2002 Honeywell International Inc. All Rights Reserved Made in China Honeywell, FlexGuard and IntelliSense are registered trademarks of Honeywell International Inc. - All other brands mentioned are the trademarks or registered trademarks of their respective owners. Specifications subject to change without prior notice. P/N 5-051-735-00 Rev G