POWEROPTIMIZER
SolarEdge Power Optimizer
Module Add-On For North America
P300 / P320 / P400 / P405
	 Up to 25% more energy
	 Superior efficiency (99.5%)
	 Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
	 Flexible system design for maximum space utilization
	 Fast installation with a single bolt
	 Next generation maintenance with module-level monitoring
	 Module-level voltage shutdown for installer and firefighter safety
PV power optimization at the module-level
www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 01/2017 V.01. Subject to change without notice.
(2)
It is not allowed to mix P405 with P300/P400/P600/P700 in one string.
P300
(for 60-cell modules)
P320
(for high-power
60-cell modules)
P400
(for 72 & 96-cell
modules)
P405
(for thin film
modules)
INPUT
Rated Input DC Power(1)
300 320 400 405 W
Absolute Maximum Input Voltage
(Voc at lowest temperature)
48 80 125 Vdc
MPPT Operating Range 8 - 48 8 - 80 12.5 - 105 Vdc
Maximum Short Circuit Current (Isc) 10 11 10.1 Adc
Maximum DC Input Current 12.5 13.75 12.63 Adc
Maximum Efficiency   99.5 %
Weighted Efficiency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15 Adc
Maximum Output Voltage 60 85 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power
Optimizer
1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
RoHS Yes 
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage 1000 Vdc
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
Dimensions (W x L x H)
128 x 152 x 27.5 /
5 x 5.97 x 1.08
128 x 152 x 35 /
5 x 5.97 x 1.37
128 x 152 x 50 /
5 x 5.97 x 1.96
mm / in
Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 gr / lb
Input Connector MC4 Compatible
Output Wire Type / Connector Double Insulated; MC4 Compatible
Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft
Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(1)
Rated STC power of the module. Module of up to +5% power tolerance allowed.
SolarEdge Power Optimizer
Module Add-On for North America
P300 / P320 / P400 / P405
PV SYSTEM DESIGN USING
A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
Minimum String Length
(Power Optimizers)
8 10 18
Maximum String Length
(Power Optimizers)
25 25 50
Maximum Power per String 5250 6000 12750 W
Parallel Strings of Different Lengths
or Orientations
Yes  

Power optimiser

  • 1.
    POWEROPTIMIZER SolarEdge Power Optimizer ModuleAdd-On For North America P300 / P320 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA
  • 2.
    © SolarEdge Technologies,Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2017 V.01. Subject to change without notice. (2) It is not allowed to mix P405 with P300/P400/P600/P700 in one string. P300 (for 60-cell modules) P320 (for high-power 60-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1) 300 320 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 80 125 Vdc MPPT Operating Range 8 - 48 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes  INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatible Output Wire Type / Connector Double Insulated; MC4 Compatible Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes