Square D® Powerlink® G3
            Lighting Control Systems
            Lighting control solutions that save
            energy, time, and space.




POWERLINK
Square D® Powerlink® G3 systems feature the robust,
               proven Powerlink remotely operated circuit breaker. This proven
               design provides long lasting rugged performance, rated to handle
               the rigors of today’s harsh high-efficiency lighting loads.




BIG SAVINGS IN A SMALL PACKAGE
               REDUCE ENERGY COST

               Square D Powerlink G3 lighting control systems provide an immediate
               return on your energy savings investment by automatically switching
               lights Off during unoccupied periods. This means big savings and a
               quick payback. Compared with other energy savings technologies,
               a Powerlink control system can provide both a lower initial
               capital outlay and greater energy savings.

               NO ADDITIONAL INSTALLATION COST

               Powerlink G3 lighting control systems are housed in the lighting
               panelboard. No extra boxes to mount, relays to wire, or complex panel
               schedules to decipher. Each Powerlink panel comes from the factory fully
               assembled and tested. Installing a Powerlink panel takes no more time
               than mounting a standard lighting panelboard.

               DESIGN SIMPLICITY

               Powerlink G3 simplifies a designer’s life by eliminating the need
               to create special lighting schedules or to negotiate with the architect
               over limited space constraints.

               Powerlink G3 systems are also fully code compliant. Meeting today’s
               energy codes, such as ASHRAE 90.1, requires a system that can be
               easily adapted to meet many different requirements. Powerlink systems
               have been designed to offer the utmost flexibility in meeting today’s
               requirements regarding automatic shut-off, space controls,
               and daylighting.

               DESIGN INTEGRITY

               A Powerlink G3 system is the only lighting control offering that is
               Underwriters Laboratory (UL) Listed for use on today’s high fault
               current systems. UL short circuit current ratings are available through
               200,000 Amps providing the designer with the only choice in meeting
               the requirements specified in the National Electrical Code® (NEC)
               110-10. By specifying Powerlink G3, designers can comfortably rest
               knowing that the product is fully code compliant.
Up to eight
                              panels can
                              be controlled
                              from a single
                              controller.

A self-contained power                        The intelligence of the
supply furnishes the power                    Powerlink G3 system
for remote circuit breaker                    comes from its micro-
switching and for the                         processor-based controller.
system's electronics.                         It processes many signals
                                              that originate externally
                                              from control devices, such
                                              as switches or sensors,
                                              or from its powerful
                                              internal time scheduler
                                              that switches breakers
                                              according to predefined
                                              daily schedules.




Innovative Square D                           Plug-on control bus strips
remote-operated circuit                       act as the bridge between
breakers combine the                          the circuit breakers and
protective features of                        the electronic control com-
conventional circuit break-                   ponents of a Powerlink G3
ers with the switching                        system. There's no compli-
functions of a contactor.                     cated, bulky control wiring
This eliminates the need                      or connectors to worry
for separate relays or                        about. The bus strips easi-
contactors and the                            ly attach to the panelboard
associated enclosures                         interior without any special
and wiring. With series                       fasteners or modifications.
connected ratings up to
200,000 RMS amperes,
Powerlink G3 circuit
breakers are designed
to handle today's and
tomorrow's high short
circuit current require-
ments. They're proven
to perform for 200,000
On/Off/On operations,
which far surpasses UL
requirements. The circuit
breakers are rated for
HACR, HID, and SWD
loads. Single-, two- and
three-pole versions
are available in ratings
up to 30A.
One size does not fit all. Your lighting control
                                                         needs are not the same as your neighbor’s;
                                                         your lighting solutions don’t have to be either.
                                                         Schneider Electric recognizes that requirements
                                                         vary among our customers. That is why we
                                                         have created four systems that can be
                                                         custom-tailored for you.



LIGHTING CONTROLS
FOR EVERY NEED
500 LEVEL SYSTEM                                         1000 LEVEL SYSTEM
Basic control for low-voltage                            Time-of-day control for meeting
switching applications                                   today’s energy code requirements
Ideal for use in facilities where time-of-day control    The low cost choice of designers looking
is being managed from a time clock or centralized        to provide a code compliant installation.
building management system.
                                                         • Same basic features of a 500 level system
• Soft mapping for grouping branch circuits into
  zones that can be operated as a common group.          • Seven-day repeating electronic clock, temperature
  Up to 64 independent zones can be configured             compensated to minimize clock drift. Includes
  for a single controller                                  automatic daylight savings setbacks, leap year
                                                           correction, 32 special holiday periods,
• Eight input terminations for connecting local            and automatic computation of sunrise/sunset times
  control devices to operate individual lighting zones
                                                         • Sixteen independently configurable time
• Input timers to provide a timed override                 schedules, each having 24 separate on/off periods
  capability to local control devices
                                                         • Sixteen input terminations for connecting local
• Blink notification to alert occupants                    control devices to operate individual lighting zones
  of an impending ‘lights out’ command
                                                         • On-board event log (viewable through
• RS232/485 port for serial communications                 PCS software)
  with other systems using industry recognized
  Modbus protocol                                        • Breaker run-time counters for tracking
                                                           burn-time on lighting fixtures.




                                                                Power supply mounts onto interior and occupies only three pole spaces.
Breaker status screen.




                 2000 LEVEL SYSTEM                                        3000 LEVEL SYSTEM
                 Fast Ethernet-based control for                          Web-enabled control for controlling and
                 managing a large lighting system                         managing the cost of the lighting system
                 Take advantage of your building’s existing Ethernet      The 3000 level system forms the foundation for
                 backbone and its open architecture and share data        a completely Web-enabled lighting control system.
                 between controllers at blistering speed. 2000 level      From the convenience of a standard Web browser,
                 systems are ideal for larger commercial and industrial   users can easily access information about the lighting
                 buildings where the information from a local             control system, initiate overrides, or make a schedule
                 control device such as a photo sensor or switch          change without having to modify the schedule in
                 is used to control branch breakers located in several    each panel.
                 different panels scattered throughout the facility.
                                                                          • Includes the same powerful features of
                 Enhances the capabilities of a 1000 level system           a 2000 level system
                 by adding:
                                                                          • Integral Web server to provide ready access
                 • 10BaseT port for peer-to-peer Ethernet                   to panel status and configuration screens
                   communications using Modbus TCP protocol
                                                                          • Email alarm notification service for automatically
                 • Ability to share remote status (input commands,          notifying assigned users of an alarm condition
                   time schedules, or zone states) with up to 255           through their computer e-mail program, pager,
                   other controllers                                        or cell phone
                 • Remote source capability for mapping up to             • Seamless coordination with Powerlink® network area
                   four local or remotely located sources (input            controllers (NACs) to provide a host of special
                   commands, time schedules, or zone states)                control capabilities including automatic load
                   with a single zone                                       shed/restore, stepped dimming, demand control,
                                                                            and integration with other equipment
                 • Network time synchronization service
                   for coordinating controller time reference             • Extends functionality of Powerlink G3 system to
                   with a centralized timeserver                            communicate with Square D® Clipsal® devices
                 • Configurable alarm generator for tagging
                   non-responding breakers and other operational
                   parameters (viewable through PCS software)




NF300OG3 Controllers support 1OBaseT Ethernet communications.
Easily connect to your existing building network.
REMOTE MONITORING AND
CONTROL AT YOUR FINGERTIPS
               Connectivity is the key to managing a lighting system. With Square D
               Powerlink G3 critical information about the lighting system is always
               available at your finger tips. With the click of a mouse, users can quickly
               observe breaker status, the operation of the system, or make
               configuration changes.

               PCS software provides users with the convenience of configuring
               a Powerlink system from a personal computer. PCS software further
               provides an added level of comfort by providing an archive backup
               of panel and system configurations. With PCS software, users have
               immediate access to their lighting control system, whether their
               computer is connected locally within the building, connected directly
               to the system controllers front panel, remotely via modem, or via an
               Ethernet connection.

               For non-technical users, Web-enabled graphics provide information
               in an easy to understand format. From the convenience of a standard
               Web browser, users can switch lighting in their area or make schedule
               changes without any technical knowledge of the lighting control system.
LIGHTING CONTROL ANYTIME … ANYWHERE.
LIGHTING CONTROL TO MEET YOUR NEEDS
                                          Powerlink is the logical choice for …
                                                       Greater space savings
                                            Lower equipment installation costs
                                                             Easier startup
                                                           Remote access
                                                providing a customized system
                                              to accommodate your application




                                                                                                                                                                       © 2006 Schneider Electric All rights reserved.




                                                         For more information call: 1-888-SQUARED
                                                         Or, visit our web site: www.squaredlightingcontrol.com
Schneider Electric - North America
                      295 Tech Park Drive
                      LaVergne, TN 37086
                      Tel: 1-888-SQUARED                 Square D, the      logo, and Powerlink are trademarks or registered trademarks of Schneider Electric and/or
                      www.squaredlightingcontrol.com     its affiliates in the United States and/or other countries.
1210BR0401R6/06

Powerlink® G3 Lighting Control Systems

  • 1.
    Square D® Powerlink®G3 Lighting Control Systems Lighting control solutions that save energy, time, and space. POWERLINK
  • 2.
    Square D® Powerlink®G3 systems feature the robust, proven Powerlink remotely operated circuit breaker. This proven design provides long lasting rugged performance, rated to handle the rigors of today’s harsh high-efficiency lighting loads. BIG SAVINGS IN A SMALL PACKAGE REDUCE ENERGY COST Square D Powerlink G3 lighting control systems provide an immediate return on your energy savings investment by automatically switching lights Off during unoccupied periods. This means big savings and a quick payback. Compared with other energy savings technologies, a Powerlink control system can provide both a lower initial capital outlay and greater energy savings. NO ADDITIONAL INSTALLATION COST Powerlink G3 lighting control systems are housed in the lighting panelboard. No extra boxes to mount, relays to wire, or complex panel schedules to decipher. Each Powerlink panel comes from the factory fully assembled and tested. Installing a Powerlink panel takes no more time than mounting a standard lighting panelboard. DESIGN SIMPLICITY Powerlink G3 simplifies a designer’s life by eliminating the need to create special lighting schedules or to negotiate with the architect over limited space constraints. Powerlink G3 systems are also fully code compliant. Meeting today’s energy codes, such as ASHRAE 90.1, requires a system that can be easily adapted to meet many different requirements. Powerlink systems have been designed to offer the utmost flexibility in meeting today’s requirements regarding automatic shut-off, space controls, and daylighting. DESIGN INTEGRITY A Powerlink G3 system is the only lighting control offering that is Underwriters Laboratory (UL) Listed for use on today’s high fault current systems. UL short circuit current ratings are available through 200,000 Amps providing the designer with the only choice in meeting the requirements specified in the National Electrical Code® (NEC) 110-10. By specifying Powerlink G3, designers can comfortably rest knowing that the product is fully code compliant.
  • 3.
    Up to eight panels can be controlled from a single controller. A self-contained power The intelligence of the supply furnishes the power Powerlink G3 system for remote circuit breaker comes from its micro- switching and for the processor-based controller. system's electronics. It processes many signals that originate externally from control devices, such as switches or sensors, or from its powerful internal time scheduler that switches breakers according to predefined daily schedules. Innovative Square D Plug-on control bus strips remote-operated circuit act as the bridge between breakers combine the the circuit breakers and protective features of the electronic control com- conventional circuit break- ponents of a Powerlink G3 ers with the switching system. There's no compli- functions of a contactor. cated, bulky control wiring This eliminates the need or connectors to worry for separate relays or about. The bus strips easi- contactors and the ly attach to the panelboard associated enclosures interior without any special and wiring. With series fasteners or modifications. connected ratings up to 200,000 RMS amperes, Powerlink G3 circuit breakers are designed to handle today's and tomorrow's high short circuit current require- ments. They're proven to perform for 200,000 On/Off/On operations, which far surpasses UL requirements. The circuit breakers are rated for HACR, HID, and SWD loads. Single-, two- and three-pole versions are available in ratings up to 30A.
  • 4.
    One size doesnot fit all. Your lighting control needs are not the same as your neighbor’s; your lighting solutions don’t have to be either. Schneider Electric recognizes that requirements vary among our customers. That is why we have created four systems that can be custom-tailored for you. LIGHTING CONTROLS FOR EVERY NEED 500 LEVEL SYSTEM 1000 LEVEL SYSTEM Basic control for low-voltage Time-of-day control for meeting switching applications today’s energy code requirements Ideal for use in facilities where time-of-day control The low cost choice of designers looking is being managed from a time clock or centralized to provide a code compliant installation. building management system. • Same basic features of a 500 level system • Soft mapping for grouping branch circuits into zones that can be operated as a common group. • Seven-day repeating electronic clock, temperature Up to 64 independent zones can be configured compensated to minimize clock drift. Includes for a single controller automatic daylight savings setbacks, leap year correction, 32 special holiday periods, • Eight input terminations for connecting local and automatic computation of sunrise/sunset times control devices to operate individual lighting zones • Sixteen independently configurable time • Input timers to provide a timed override schedules, each having 24 separate on/off periods capability to local control devices • Sixteen input terminations for connecting local • Blink notification to alert occupants control devices to operate individual lighting zones of an impending ‘lights out’ command • On-board event log (viewable through • RS232/485 port for serial communications PCS software) with other systems using industry recognized Modbus protocol • Breaker run-time counters for tracking burn-time on lighting fixtures. Power supply mounts onto interior and occupies only three pole spaces.
  • 5.
    Breaker status screen. 2000 LEVEL SYSTEM 3000 LEVEL SYSTEM Fast Ethernet-based control for Web-enabled control for controlling and managing a large lighting system managing the cost of the lighting system Take advantage of your building’s existing Ethernet The 3000 level system forms the foundation for backbone and its open architecture and share data a completely Web-enabled lighting control system. between controllers at blistering speed. 2000 level From the convenience of a standard Web browser, systems are ideal for larger commercial and industrial users can easily access information about the lighting buildings where the information from a local control system, initiate overrides, or make a schedule control device such as a photo sensor or switch change without having to modify the schedule in is used to control branch breakers located in several each panel. different panels scattered throughout the facility. • Includes the same powerful features of Enhances the capabilities of a 1000 level system a 2000 level system by adding: • Integral Web server to provide ready access • 10BaseT port for peer-to-peer Ethernet to panel status and configuration screens communications using Modbus TCP protocol • Email alarm notification service for automatically • Ability to share remote status (input commands, notifying assigned users of an alarm condition time schedules, or zone states) with up to 255 through their computer e-mail program, pager, other controllers or cell phone • Remote source capability for mapping up to • Seamless coordination with Powerlink® network area four local or remotely located sources (input controllers (NACs) to provide a host of special commands, time schedules, or zone states) control capabilities including automatic load with a single zone shed/restore, stepped dimming, demand control, and integration with other equipment • Network time synchronization service for coordinating controller time reference • Extends functionality of Powerlink G3 system to with a centralized timeserver communicate with Square D® Clipsal® devices • Configurable alarm generator for tagging non-responding breakers and other operational parameters (viewable through PCS software) NF300OG3 Controllers support 1OBaseT Ethernet communications. Easily connect to your existing building network.
  • 6.
    REMOTE MONITORING AND CONTROLAT YOUR FINGERTIPS Connectivity is the key to managing a lighting system. With Square D Powerlink G3 critical information about the lighting system is always available at your finger tips. With the click of a mouse, users can quickly observe breaker status, the operation of the system, or make configuration changes. PCS software provides users with the convenience of configuring a Powerlink system from a personal computer. PCS software further provides an added level of comfort by providing an archive backup of panel and system configurations. With PCS software, users have immediate access to their lighting control system, whether their computer is connected locally within the building, connected directly to the system controllers front panel, remotely via modem, or via an Ethernet connection. For non-technical users, Web-enabled graphics provide information in an easy to understand format. From the convenience of a standard Web browser, users can switch lighting in their area or make schedule changes without any technical knowledge of the lighting control system.
  • 7.
  • 8.
    LIGHTING CONTROL TOMEET YOUR NEEDS Powerlink is the logical choice for … Greater space savings Lower equipment installation costs Easier startup Remote access providing a customized system to accommodate your application © 2006 Schneider Electric All rights reserved. For more information call: 1-888-SQUARED Or, visit our web site: www.squaredlightingcontrol.com Schneider Electric - North America 295 Tech Park Drive LaVergne, TN 37086 Tel: 1-888-SQUARED Square D, the logo, and Powerlink are trademarks or registered trademarks of Schneider Electric and/or www.squaredlightingcontrol.com its affiliates in the United States and/or other countries. 1210BR0401R6/06