1
CATALOGUE of Ultrasonic Flow Meters
We are specialized in the manufacture of ultrasonic flow meter,ultrasonic water meter,ultrasonic heat
meter.through years of hard work,with cutting-edge technology,we have grow up to the NO. 1 company in the
field of ultrasonic measuring instruments in China.that is why our products have obtained more than 60% of
the market share in China.at the same time ,it is our goal to develop our market all over the world.
1)Hand-held / handhold flow meter----Z ERO100HU
2)Portable ultrasonic flow meter( (printing or SD card data logger, Built-in Printeroptional)---Z ERO100PU
3)Fixed type ultrasonic flow meter(SD card data logger optional)-----Z ERO100FU
I: Z ERO100FU -FM----Modular type ultrasonic flow meter/heat meter II:
Z ERO100FU-F1---Clamp-on Wall-mount Ultrasonic Flow/heat meter
Z ERO100FU -F2----Ex-proof Wall-mount Ultrasonic Flow/heat meter
Z ERO100FU -F2 A--No Ex-proof Wall-mount Ultrasonic Flowmeter
Z ERO100FU -F3----Panel-mount Ultrasonic Flow meter
Z ERO100FU-F4----Separated type (yellow shell) ultrasonic flow meter
III: Z ERO100FU-Y-----Integrated type (yellow shell) ultrasonic flow meter
4) In line Water Meter Z ERO100W (with separated or integratedsensors)
5) Flow Sensor for measuring flow rate:
I: Clamp on type
II: Insertion type
III: Inline pipe type
6) Temperature Sensor for measuring heat or energy
I: Clamp on temperature sensor
II: Insertion temperature sensor
Separated with sensor
Integrated with sensor
2
1) HANDHELD ULTRASONIC FLOWMETER
Repeatability Better than 0.2%
Accuracy ±1% of reading at rates>0.2 mps
Response Time 0-999 seconds, user-configurable
Velocity ±32 m/s
Totalizer 7-digit totals for net, positive and negative flow respectively
Liquid Types Virtually all liquids
Security Setup values Modification Lockout. Access code needs unlocking
Display 4x8 Chinese characters or 4x16 English letters,display instant flow,velocity,total
flow,signal status
Signal output Non-isolation RS232(FUJI extention protocol) ,one channel isolation OCT
output
Transducers Clamp on type transducers
Transducer Cord Length Standard 2x10 meters, optional 2x 500 meters
Power Supply
3 AAA Ni-H built-in batteries. When fully recharged it will last over 12 hours of
operation.
100V-240VAC for the charger
Data Logger Built-in data logger can store over 2000 lines of data
Housing Material ABS
Case Size 100x66x20mm
Handset Weight 514g (1.2 lbs) with batteries
3
The ZERO100HU ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed
conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling
operation and easy installation.
The ZERO100HU transit time flow meter utilizes two transducers that function as both ultrasonic transmitters
and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each
other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method
where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on
opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method
depends on pipe and liquid characteristics.
The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound
energy between the two transducers and measuring the transit time that it takes for sound to travel between
the two transducers. The difference in the transit time measured is directly and exactly related to the
velocity of the liquid in the pipe.
Transducer
model
S2 H
(H-temperature
with small size)
M2 H
(H-temperature
with medium size)
L2H
(H-temperature
with large size)
HS
(small Sensor
in track with
handle)
HM
(medium Sensor
in track without
handle)
C11
(insertion
sensor)
pipe diameter
range
(mm)
DN15-DN100 DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700 DN80--DN6000
Fluid
temperature
(℃)
-30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃
Outer size
(mm)
45×30×30mm 60×45×45 80×70×55 200*25*25 280*40*40
Weight
(g)
75 259 535 250 1080 1500
photos
4
2) PORTABLE ULTRASONIC FLOW METER
(printing or SD card data logger optional )
ZERO100PU portable ultrasonic flow meter/heat meter is suitable for any industry application of fluid
flow/heat online calibration and measurement.good at easy operation,high accuracy,good consistency,online
printing, longer battery powered time,heat measurement,and so on.
Specifications:
Accuracy: better than 1%
Repeatability:better than 0.2%
Power:220VAC(standard),110VAC(optional)
Battery:built-in ni-mh charged battery work for 24 hours continually
Sensors: clamp on type
Display: two lines displaying(instant flow,total flow,signal status)
Signal output: isolation RS485
Communication protocol:MODBUS protocol,FUJI extension protocol.
Printing output: built-in one body thermal printer.
(optional choice:if not use printer,you can choose SD card data logger to store datas,and read them on the
computer)
Heat measurement function;clamp on type platinum resistors(PT100) to measure heat quantity
Other function :self-diagnose ,indicate the working status is normal or not.
Saving function : Additional SD for large data saving, could optional(4G)
5
Transducer
model
S2 H
(H-temperature
with small size)
M2 H
(H-temperature
with medium size)
L2H
(H-temperature
with large size)
HS
(small Sensor
in track with
handle)
HM
(medium Sensor
in Tracks with no
handle)
pipe
diameter
range
(mm)
DN15-DN100 DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700
Fluid
temperature
(℃)
-30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃
Outer size
(mm)
45×30×30mm 60×45×45 80×70×55 200*25*25 280*40*40
Weight
(g)
75 259 535 250 1080
photos
3) Fixed ultrasonic flow meter (SD card data logger and BTU energy optional)
I: Modular type - ZERO100FM:
ZERO100FM style flow/heat module(18 version),added 4 keys based on previous version,realized to set parameters on
spot,especially suitable to use in the mating project of system integrators,it is the first choice of flow rate and heat
measuring meters for network monitor items of water conservancy and heat supplying system etc.
6
Technology features:
1:operating power:isolation 8-36VDC
2:current: 50mA(under the condition of connection without keyboard display and sound of buzzer)
3: signal output: one channel standard isolation RS485 output
One channel isolation 4-20mA or 0-20mA passive output.
Two channel OCT output(programmed between the pulse width(6-1000ms),default before
leaving factory (200ms))
4: signal input: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the
function of displaying heat quantity.
Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of
pressure, liquid level, temperature and so on.
5:display:2*10 backlit LCD,displaying instant flow rate,velocity,positive,negative,net totaliser flow rate.
6:operating: 4 keypad tactile keyboard operating
7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the
last 512 days,128 months,10years
Automatic memory the time of power on/off and flow rate of the last 30 times, realize to
replenish by hand or automatically,read the datas through Modbus communication protocol.
8:protection level:IP57
9:transducer:clamp-on type,insertion type,in-line type.
Optional accessory:
1:clamp-on transducer(standard S1 type,standard M1 type,high temperature S1H,high temperature M1H)
2:insertion transducer(standard insertion B,cement insertion B)
3:in-line type transducer(hygienic type,л type,standard type)
4:remote second times operation meter(wall-mounted type,panel-mounted type)
5:PT100 there wire platinum resistor(used for heat meter)
6: strap(applied with installation of transducers on cast iron,GRP,PVC,etc. that can not be welded directly.
7: special shielded twisted pair cable
8: ultrasonic thickness gauge(measure the thickness of pipe,reduce error,increase accuracy)
II: Fixed type (with SD card data logger optional)
7
ZERO101FU series meters are applicable to measure liquid flow in industry application.mainframe include wall-
mounted standard type(Z100FU -F1), wall mounted ex-proof type(Z100FU -F2), wall mounted no-ex-proof
type (Z100FU -F2A), panel type (Z100FU -F3) and native place displaying(Z100FU -F4). sensors include
clamp on type,insertion type,inline type.
Technology features:
1:operating power :AC 85—264V or isolation DC 8-36VDC
2:repeatability:better than 0.2%.accuracy:better than 1%
3:signal output :one channel standard isolation RS485 output
One channel isolation 4-20mA or 0-20mA active output.
One channel OCT output(programmed between the pulse width(6-1000ms),default before
leaving factory (200ms))
One channel isolation relay output,with positive,negative,net accumulation pulses and different
alarm signals.
4:signal input: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the
function of displaying heat quantity.
Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of
pressure, liquid level, temperature and so on.
5::display:2*20 backlit LCD(Chinese and English optional)
6:operating:4*4 tactile keypad or magnetic 4 keypads operating(F4 mainframe)
7:other functions:automatic memory the positive,negative,net totaliser flow rate and heat quantity of the last
512 days,128 months,10years
Automatic memory the time of power on/off and flow rate of the last 30 times, realize to
replenish by hand or automatically,read the datas through Modbus communication protocol.
Additional SD for large data saving, could optional(4G)
8:protection level:mainframe:IP65,IP68(F4 mainframe),transducer:IP:68
9:ex-proof:EXd » BT4(Z100HF2 type)
10:transducer: clamp-on type,insertion type,in-line type.
Optional accessory:
1:clamp-on transducer(standard S1 style,standard M1 style,high temperature S1H,high temperature M1H)
2:insertion transducer(standard insertion B,cement insertion B)
3:in-line type transducer(hygienic style, Π style,standard style)
4:PT100 3 wire system platinum resistor(one pair,used for heat meter)
5:SEYV75-2 style special shielded twisted pair cable
6:strap(applied with installation of transducers on cast iron,GRP,PVC,etc. that can not be welded directly).
8
Transducer
model
S2 H
(small size)
M2 H
(medium size)
L2H
(large size)
HS
(small Sensor
in track with
handle)
HM
(medium Sensor
in Tracks with
no handle)
C11
(insertion
type)
pipe
diameter
range
(mm)
DN15-
DN100
DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700 DN80 above
Fluid
temperatur
e
(℃)
-30℃~ 160
℃
-30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -40℃~160℃
Outer size
(mm)
45×30×30
mm
60×45×45 80×70×55 200*25*25 280*40*40
Weight
(g)
75 259 535 250 1080 IP68
photos
III: ZERO100WY-----with Integrated type and separated type (yellow shell)
ZERO100HY ultrasonic flowmeter/heat meter:it make the main board of Z12 or Z18 connect to a 20 lines 4 keys
parallel port keyboard monitor,then encapsulate them in a sealed enclosure,realize on-line display and operation on
spot.it solved the problem that owing to the reason of people that make the measured pipe parameters
inaccuracy ,caused errors that lowered the measurement accuracy during the period of installing the clamp-on type
and insertion type transducers .it has the advantages of high accuracy,wide measurement range,no pressure
lost,easy installation,no need to set parameter,etc.it is the future for the flowmeter and heat meter.
hygienic style Л style in line type standard in line type
9
on-line showing with insertion sensor(separated type)
Technology features:
1: operating power :AC 85—264V or isolation DC 24V or battery
2: current: 50mA(under the condition of connection without keyboard display and sound of buzzer)
3:output optional: one channel standard isolation RS485 output
One channel isolation 4-20mA or 0-20mA passive output.
Two channel OCT output(programmed between the pulse width(6-1000ms),default before
leaving factory (200ms))
4:input optional: two channel three wire system PT100 platinum resistor input loop,to make heat meter has
the function of displaying heat quantity.
5:display:2*10 backlit LCD(Chinese and English optional)
6: operating:magnetic 4 keypads to operate
7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the
last 512 days,128 months,10years
Automatic memory the time of power on/off and flow rate of the last 30 times, realize to
replenish by hand or automatically,read the datas through Modbus communication protocol.
8:protection level:IP68
Optional accessory:
1:PT100 three wire platinum resistor( a pair,used for heat meter)
2:ultrasonic thickness gauge: (measure the thickness of pipe,reduce error,increase accuracy)
4) In line WaterMeter-----ZERO100W
Л style in line type hygienic style flange in line type
10
with clamp on sensor(separated type) on-line showing
Technology features:
1: operating power : 8-24VDC or only battery supply
2: current: 50mA(under the condition of connection without keyboard display and sound of buzzer)
3:output optional: one channel standard isolation RS485 output
One channel isolation 4-20mA or 0-20mA passive output.
Two channel OCT output(programmed between the pulse width(6-1000ms),default before
leaving factory (200ms))
4:input optional: two channel three wire system PT100 platinum resistor input loop,to make heat meter has
the function of displaying heat quantity.
5:display:2*10 backlit LCD(Chinese and English optional)
6: operating:magnetic 4 keypads to operate
7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the
last 512 days,128 months,10years
Automatic memory the time of power on/off and flow rate of the last 30 times, realize to
replenish by hand or automatically,read the datas through Modbus communication protocol.
8:protection level:IP68
9: accuracy: 2
Optional accessory:
1:PT100 three wire platinum resistor( a pair,used for heat meter)
2:ultrasonic thickness gauge: (measure the thickness of pipe,reduce error,increase accuracy)
5) Flow Sensor for measuring the flow rate:
I:clamp on type sensors:
S2H sensor M2H sensor L2H sensor
11
transducer Standard S2 type Standard M2 type Standard L2type
Suitable pipe diameter
(mm)
DN15-DN100 DN50-DN700 DN300-DN6000
Fluid temperature
(℃)
-30℃~160℃ -30℃~160℃ -30℃~160℃
Outer size
(mm)
45×30×30mm 60×45×45 80×70×55
Quality
(g)
75g 250g 650g
II: insertion typesensors:
insertion B type(insert directly) Insertion B type (for sement pipe )
Suitable diameter Above DN80mm Above DN80mm
Installation room ≥550mm ≥700mm
Fluid temperature -40℃-160℃ -40℃-160℃
Transducer material 316L stainless steel 316L stainless steel
III:inline type sensors:
Parameters π-type transducer Standard pipe transducer
Material Stainless steel Carbon steel(stainless steel is optional)
Pipe size DN15-DN40MM DN50-DN6000MM
Connection: Flange type Flange type
Application of temperature -40℃~160℃
Protection class IP68(can work in water, and water depth≤3 meter)
Rated pressure please refer to following table
dimension please refer to following table
12
6) Temperature sensor for measuring heat or energy :for ALLthe series except handheld type
Signal output 4-20MA(default)or RS485
power supply voltage AC220V(default)or DC24V
control 4 line relay(2 up control,2 down control)
Measure range 5、10、15、20、30、40、50m
accuracy 0.25%(range<20m), 0.5%(range>20m)
distinguishability 1mm(range<20m), 1cm(range>20m)
Dead zone(blanking
distance)
0.3~1.5m
Display type LCD 16x2,backlight
Display mode level,distance
temperature -20℃~80℃
Ip protection glass transmitter:IP65 sensor:IP67

Ultrasonic series flow meter catalog

  • 1.
    1 CATALOGUE of UltrasonicFlow Meters We are specialized in the manufacture of ultrasonic flow meter,ultrasonic water meter,ultrasonic heat meter.through years of hard work,with cutting-edge technology,we have grow up to the NO. 1 company in the field of ultrasonic measuring instruments in China.that is why our products have obtained more than 60% of the market share in China.at the same time ,it is our goal to develop our market all over the world. 1)Hand-held / handhold flow meter----Z ERO100HU 2)Portable ultrasonic flow meter( (printing or SD card data logger, Built-in Printeroptional)---Z ERO100PU 3)Fixed type ultrasonic flow meter(SD card data logger optional)-----Z ERO100FU I: Z ERO100FU -FM----Modular type ultrasonic flow meter/heat meter II: Z ERO100FU-F1---Clamp-on Wall-mount Ultrasonic Flow/heat meter Z ERO100FU -F2----Ex-proof Wall-mount Ultrasonic Flow/heat meter Z ERO100FU -F2 A--No Ex-proof Wall-mount Ultrasonic Flowmeter Z ERO100FU -F3----Panel-mount Ultrasonic Flow meter Z ERO100FU-F4----Separated type (yellow shell) ultrasonic flow meter III: Z ERO100FU-Y-----Integrated type (yellow shell) ultrasonic flow meter 4) In line Water Meter Z ERO100W (with separated or integratedsensors) 5) Flow Sensor for measuring flow rate: I: Clamp on type II: Insertion type III: Inline pipe type 6) Temperature Sensor for measuring heat or energy I: Clamp on temperature sensor II: Insertion temperature sensor Separated with sensor Integrated with sensor
  • 2.
    2 1) HANDHELD ULTRASONICFLOWMETER Repeatability Better than 0.2% Accuracy ±1% of reading at rates>0.2 mps Response Time 0-999 seconds, user-configurable Velocity ±32 m/s Totalizer 7-digit totals for net, positive and negative flow respectively Liquid Types Virtually all liquids Security Setup values Modification Lockout. Access code needs unlocking Display 4x8 Chinese characters or 4x16 English letters,display instant flow,velocity,total flow,signal status Signal output Non-isolation RS232(FUJI extention protocol) ,one channel isolation OCT output Transducers Clamp on type transducers Transducer Cord Length Standard 2x10 meters, optional 2x 500 meters Power Supply 3 AAA Ni-H built-in batteries. When fully recharged it will last over 12 hours of operation. 100V-240VAC for the charger Data Logger Built-in data logger can store over 2000 lines of data Housing Material ABS Case Size 100x66x20mm Handset Weight 514g (1.2 lbs) with batteries
  • 3.
    3 The ZERO100HU ultrasonicflow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation. The ZERO100HU transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe. Transducer model S2 H (H-temperature with small size) M2 H (H-temperature with medium size) L2H (H-temperature with large size) HS (small Sensor in track with handle) HM (medium Sensor in track without handle) C11 (insertion sensor) pipe diameter range (mm) DN15-DN100 DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700 DN80--DN6000 Fluid temperature (℃) -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ Outer size (mm) 45×30×30mm 60×45×45 80×70×55 200*25*25 280*40*40 Weight (g) 75 259 535 250 1080 1500 photos
  • 4.
    4 2) PORTABLE ULTRASONICFLOW METER (printing or SD card data logger optional ) ZERO100PU portable ultrasonic flow meter/heat meter is suitable for any industry application of fluid flow/heat online calibration and measurement.good at easy operation,high accuracy,good consistency,online printing, longer battery powered time,heat measurement,and so on. Specifications: Accuracy: better than 1% Repeatability:better than 0.2% Power:220VAC(standard),110VAC(optional) Battery:built-in ni-mh charged battery work for 24 hours continually Sensors: clamp on type Display: two lines displaying(instant flow,total flow,signal status) Signal output: isolation RS485 Communication protocol:MODBUS protocol,FUJI extension protocol. Printing output: built-in one body thermal printer. (optional choice:if not use printer,you can choose SD card data logger to store datas,and read them on the computer) Heat measurement function;clamp on type platinum resistors(PT100) to measure heat quantity Other function :self-diagnose ,indicate the working status is normal or not. Saving function : Additional SD for large data saving, could optional(4G)
  • 5.
    5 Transducer model S2 H (H-temperature with smallsize) M2 H (H-temperature with medium size) L2H (H-temperature with large size) HS (small Sensor in track with handle) HM (medium Sensor in Tracks with no handle) pipe diameter range (mm) DN15-DN100 DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700 Fluid temperature (℃) -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ Outer size (mm) 45×30×30mm 60×45×45 80×70×55 200*25*25 280*40*40 Weight (g) 75 259 535 250 1080 photos 3) Fixed ultrasonic flow meter (SD card data logger and BTU energy optional) I: Modular type - ZERO100FM: ZERO100FM style flow/heat module(18 version),added 4 keys based on previous version,realized to set parameters on spot,especially suitable to use in the mating project of system integrators,it is the first choice of flow rate and heat measuring meters for network monitor items of water conservancy and heat supplying system etc.
  • 6.
    6 Technology features: 1:operating power:isolation8-36VDC 2:current: 50mA(under the condition of connection without keyboard display and sound of buzzer) 3: signal output: one channel standard isolation RS485 output One channel isolation 4-20mA or 0-20mA passive output. Two channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms)) 4: signal input: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the function of displaying heat quantity. Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of pressure, liquid level, temperature and so on. 5:display:2*10 backlit LCD,displaying instant flow rate,velocity,positive,negative,net totaliser flow rate. 6:operating: 4 keypad tactile keyboard operating 7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the last 512 days,128 months,10years Automatic memory the time of power on/off and flow rate of the last 30 times, realize to replenish by hand or automatically,read the datas through Modbus communication protocol. 8:protection level:IP57 9:transducer:clamp-on type,insertion type,in-line type. Optional accessory: 1:clamp-on transducer(standard S1 type,standard M1 type,high temperature S1H,high temperature M1H) 2:insertion transducer(standard insertion B,cement insertion B) 3:in-line type transducer(hygienic type,л type,standard type) 4:remote second times operation meter(wall-mounted type,panel-mounted type) 5:PT100 there wire platinum resistor(used for heat meter) 6: strap(applied with installation of transducers on cast iron,GRP,PVC,etc. that can not be welded directly. 7: special shielded twisted pair cable 8: ultrasonic thickness gauge(measure the thickness of pipe,reduce error,increase accuracy) II: Fixed type (with SD card data logger optional)
  • 7.
    7 ZERO101FU series metersare applicable to measure liquid flow in industry application.mainframe include wall- mounted standard type(Z100FU -F1), wall mounted ex-proof type(Z100FU -F2), wall mounted no-ex-proof type (Z100FU -F2A), panel type (Z100FU -F3) and native place displaying(Z100FU -F4). sensors include clamp on type,insertion type,inline type. Technology features: 1:operating power :AC 85—264V or isolation DC 8-36VDC 2:repeatability:better than 0.2%.accuracy:better than 1% 3:signal output :one channel standard isolation RS485 output One channel isolation 4-20mA or 0-20mA active output. One channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms)) One channel isolation relay output,with positive,negative,net accumulation pulses and different alarm signals. 4:signal input: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the function of displaying heat quantity. Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of pressure, liquid level, temperature and so on. 5::display:2*20 backlit LCD(Chinese and English optional) 6:operating:4*4 tactile keypad or magnetic 4 keypads operating(F4 mainframe) 7:other functions:automatic memory the positive,negative,net totaliser flow rate and heat quantity of the last 512 days,128 months,10years Automatic memory the time of power on/off and flow rate of the last 30 times, realize to replenish by hand or automatically,read the datas through Modbus communication protocol. Additional SD for large data saving, could optional(4G) 8:protection level:mainframe:IP65,IP68(F4 mainframe),transducer:IP:68 9:ex-proof:EXd » BT4(Z100HF2 type) 10:transducer: clamp-on type,insertion type,in-line type. Optional accessory: 1:clamp-on transducer(standard S1 style,standard M1 style,high temperature S1H,high temperature M1H) 2:insertion transducer(standard insertion B,cement insertion B) 3:in-line type transducer(hygienic style, Π style,standard style) 4:PT100 3 wire system platinum resistor(one pair,used for heat meter) 5:SEYV75-2 style special shielded twisted pair cable 6:strap(applied with installation of transducers on cast iron,GRP,PVC,etc. that can not be welded directly).
  • 8.
    8 Transducer model S2 H (small size) M2H (medium size) L2H (large size) HS (small Sensor in track with handle) HM (medium Sensor in Tracks with no handle) C11 (insertion type) pipe diameter range (mm) DN15- DN100 DN50-DN700 DN300-DN6000 DN15-DN100 DN50-DN700 DN80 above Fluid temperatur e (℃) -30℃~ 160 ℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -30℃~160℃ -40℃~160℃ Outer size (mm) 45×30×30 mm 60×45×45 80×70×55 200*25*25 280*40*40 Weight (g) 75 259 535 250 1080 IP68 photos III: ZERO100WY-----with Integrated type and separated type (yellow shell) ZERO100HY ultrasonic flowmeter/heat meter:it make the main board of Z12 or Z18 connect to a 20 lines 4 keys parallel port keyboard monitor,then encapsulate them in a sealed enclosure,realize on-line display and operation on spot.it solved the problem that owing to the reason of people that make the measured pipe parameters inaccuracy ,caused errors that lowered the measurement accuracy during the period of installing the clamp-on type and insertion type transducers .it has the advantages of high accuracy,wide measurement range,no pressure lost,easy installation,no need to set parameter,etc.it is the future for the flowmeter and heat meter. hygienic style Л style in line type standard in line type
  • 9.
    9 on-line showing withinsertion sensor(separated type) Technology features: 1: operating power :AC 85—264V or isolation DC 24V or battery 2: current: 50mA(under the condition of connection without keyboard display and sound of buzzer) 3:output optional: one channel standard isolation RS485 output One channel isolation 4-20mA or 0-20mA passive output. Two channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms)) 4:input optional: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the function of displaying heat quantity. 5:display:2*10 backlit LCD(Chinese and English optional) 6: operating:magnetic 4 keypads to operate 7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the last 512 days,128 months,10years Automatic memory the time of power on/off and flow rate of the last 30 times, realize to replenish by hand or automatically,read the datas through Modbus communication protocol. 8:protection level:IP68 Optional accessory: 1:PT100 three wire platinum resistor( a pair,used for heat meter) 2:ultrasonic thickness gauge: (measure the thickness of pipe,reduce error,increase accuracy) 4) In line WaterMeter-----ZERO100W Л style in line type hygienic style flange in line type
  • 10.
    10 with clamp onsensor(separated type) on-line showing Technology features: 1: operating power : 8-24VDC or only battery supply 2: current: 50mA(under the condition of connection without keyboard display and sound of buzzer) 3:output optional: one channel standard isolation RS485 output One channel isolation 4-20mA or 0-20mA passive output. Two channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms)) 4:input optional: two channel three wire system PT100 platinum resistor input loop,to make heat meter has the function of displaying heat quantity. 5:display:2*10 backlit LCD(Chinese and English optional) 6: operating:magnetic 4 keypads to operate 7:other functions: automatic memory the positive,negative,net totaliser or flow rate and heat quantity of the last 512 days,128 months,10years Automatic memory the time of power on/off and flow rate of the last 30 times, realize to replenish by hand or automatically,read the datas through Modbus communication protocol. 8:protection level:IP68 9: accuracy: 2 Optional accessory: 1:PT100 three wire platinum resistor( a pair,used for heat meter) 2:ultrasonic thickness gauge: (measure the thickness of pipe,reduce error,increase accuracy) 5) Flow Sensor for measuring the flow rate: I:clamp on type sensors: S2H sensor M2H sensor L2H sensor
  • 11.
    11 transducer Standard S2type Standard M2 type Standard L2type Suitable pipe diameter (mm) DN15-DN100 DN50-DN700 DN300-DN6000 Fluid temperature (℃) -30℃~160℃ -30℃~160℃ -30℃~160℃ Outer size (mm) 45×30×30mm 60×45×45 80×70×55 Quality (g) 75g 250g 650g II: insertion typesensors: insertion B type(insert directly) Insertion B type (for sement pipe ) Suitable diameter Above DN80mm Above DN80mm Installation room ≥550mm ≥700mm Fluid temperature -40℃-160℃ -40℃-160℃ Transducer material 316L stainless steel 316L stainless steel III:inline type sensors: Parameters π-type transducer Standard pipe transducer Material Stainless steel Carbon steel(stainless steel is optional) Pipe size DN15-DN40MM DN50-DN6000MM Connection: Flange type Flange type Application of temperature -40℃~160℃ Protection class IP68(can work in water, and water depth≤3 meter) Rated pressure please refer to following table dimension please refer to following table
  • 12.
    12 6) Temperature sensorfor measuring heat or energy :for ALLthe series except handheld type Signal output 4-20MA(default)or RS485 power supply voltage AC220V(default)or DC24V control 4 line relay(2 up control,2 down control) Measure range 5、10、15、20、30、40、50m accuracy 0.25%(range<20m), 0.5%(range>20m) distinguishability 1mm(range<20m), 1cm(range>20m) Dead zone(blanking distance) 0.3~1.5m Display type LCD 16x2,backlight Display mode level,distance temperature -20℃~80℃ Ip protection glass transmitter:IP65 sensor:IP67