Underwater Temperature
Loggers
Considerations for Selection
and Deployment
Metrics GmbH • Elberfelder Str. 19-21 • 58095 Hagen
Telefon: 02331 3483086 • Telefax: 02331 3483088
E-Mail: info@metrics24.de • www.metrics24.de
Introduction
Researchers and resource managers working in the world’s rivers, lakes, and
oceans often need to monitor water temperature over time. Whether they are
studying coral reef bleaching, assessing industrial thermal loading in lakes,
modeling freshwater fish populations, or developing marine technology, users
must have temperature data collection methods that are accurate, reliable, and
practical for their particular field sites and studies.
Most researchers today rely on electronic underwater temperature logging
devices for their monitoring needs, rather than on human data collection. The
latest of these loggers are small, rugged, inexpensive, and easy to use. These
battery-powered devices can be programmed to gather data for months or years
at a time and can withstand an extensive range of environmental conditions,
including wide temperature fluctuations, rushing rocky streams, and ocean
storms.
This report provides general information about monitoring water temperature, and
serves as a guide to selecting underwater temperature loggers. It also identifies
some of the challenges specific to particular field sites, and provides tips on
deploying loggers in such environments.
1
Data loggers for monitoring
Most researchers turn to underwater temperature data loggers to address their
monitoring needs. These devices are low-cost, compact instruments with built-in
processors, high-accuracy temperature sensing, and battery power in a rugged
enclosure designed for long-term underwater deployment. They range from cigar-
sized units to units the size of a short stack of quarters, typically with anchoring
holes at one end.
The latest models feature precision sensors that can measure water
temperatures ranging from 0°C to 50°C (32°F to 122°F) in plastic housings
and from 0°C to 125°C (32°F to 257°F) in stainless steel or titanium housings.
Typically, underwater data loggers are deployed for months at a time, collecting
temperature data at user-defined intervals and storing it digitally into logger
memory. By operating in a continuous, 24/7 monitoring mode, underwater loggers
eliminate many of the hassles of traditional monitoring methods. And, because
the devices are typically inexpensive, users are often able to deploy loggers at
more points in a water body.
Underwater data loggers also simplify the process of reporting data. Instead of
having to manually record times and temperatures, users can simply offload
the logger data to a laptop computer and create detailed graphs or tables with
the click of a mouse button. The charts can be easily printed or the data can be
exported to other software applications as necessary.
2
Using underwater temperature data loggers
While specific logger operating procedures vary among manufacturers, the
process of using underwater temperature loggers is relatively straightforward
and involves three main phases: logger configuration and launch; deployment;
and data processing (data retrieval, QA/QC, integration into a database, and
analysis).
Configuration and launch
A logger is typically configured by connecting it to a computer (with a cable or
base station) and making a number of selections:
•	Logging interval – This indicates how often the logger will take a water
temperature measurement. The frequency of this interval will determine the
maximum deployment time for the device.
•	Logger start time – This allows the user to start the logger immediately or
postpone it until a specific date and time.
Once these selections are made, the user simply clicks a start button in the
logger software and the device is ready to start monitoring.
Basic deployment of a HOBO Pendant series water temperature data logger
3
Deployment
Several steps are involved in deploying an underwater data logger, including site
selection, anchoring the logger, documenting logger location, and retrieval. See
following pages for specific field tips.
•	Site selection – This refers to the particular location in a body of water where
temperature sampling is needed. Choose a site with good mixing, such as
the turbulent area below a rock. Also make sure that the location will still
be submerged at the low water point, and consider potential impact from
moving debris.
•	Anchoring the logger – There are a number of ways to secure underwater
data loggers in still, flowing, and marine waters. Some users tether a logger
to a cement block or brick using nylon cord, whereas others choose to drive
a rebar stake into the streambed or shoreline and tie or clamp a logger to
the stake. For deepwater deployment, users usually use plastic cable ties
to attach a logger to a mooring line or sand screw. See following pages for
more tips specific to certain environments.
For any deployment, users should think about potential natural and human
factors that might dislodge or damage a logger, and consider protecting or
camouflaging the device as necessary. Also consider whether you want to read
out the logger’s data during deployment. In that case, you can attach the device
with a tether line so it can be pulled up.
•	Documenting logger location – To ensure successful retrieval of underwater
data loggers, it is important to document the specific location of each one
during deployment. This is especially important if more than one person
is working with the loggers. Documenting location in at least two ways is
recommended, and can be done by taking a photograph of each monitoring
site, marking the location on a map or aerial photograph, entering GPS
coordinates, and using words to describe the location in a data book.
Affixing a “please return to” label to the logger is also a good idea, in the
uncommon event that a logger becomes dislodged.
Cinder block data logger anchoring method
For any deployment, users
should think about potential
natural and human factors
that might dislodge or damage
a logger, and consider
protecting or camouflaging the
device as necessary.
4
From the field: Tips for deploying underwater
temperature loggers
Loggers have been launched in a wide variety of field conditions worldwide, and
researchers have gained experience in making sure their devices stay put. Here are
some notes from the field and factors to consider when deploying loggers in specific
environments:
Stream/river/or other shallow deployment
Flowing waters are variable throughout the year and can change even on a daily
basis. A logger must be positioned at an adequate depth so that it is always
underwater. When choosing sites, take into account incoming tributaries, human-
generated thermal pollution (measure upstream and downstream of inlet), and
shading (for sunny sites that are shallow it may be necessary to use a white
protective boot or paint on the logger in order to minimize solar heating). In rocky
streams and rivers, heavy-duty garden tools are useful for shifting rocks during
logger deployment and retrieval.
Ocean and lake deployment (deep water)
Wave action, currents, and storms are important considerations when securing data
loggers in deep waters. Some users have been successful in anchoring loggers
to mooring lines on sand screws or pins (widely available at boating equipment
suppliers) driven into solid substrate. Some users attach the logger to the screw or
pin itself, and recommend using more than one cable tie in case one breaks loose.
In marine environments, a scraping tool is useful if encrusting organisms colonize
the logger. In particularly rough conditions, it is wise to secure the entire body of the
logger, rather than just one end.
Intertidal deployment
Intertidal environments are alternately submerged in seawater and exposed to the
air. They are also subject to wide temperature fluctuations, so logger anchoring
materials must be able to withstand such varying conditions. Putty epoxy that cures
underwater and in air has been used successfully to anchor loggers to rocks in the
intertidal zone.
Areas of heavy human use
Humans use water bodies commercially and recreationally, and having curious
people around field sites can be a challenge. In addition to boating and fishing
activity, vandalism can potentially damage or dislodge a
temperature logger. Camouflage is a necessity, and can
be achieved by burying the logger under rocks or gravel,
buying and painting a protective boot for the logger (boots are
available from most manufacturers), or enclosing the logger in
a secure wire cage. Also, avoid using mounting stakes or posts
in areas where they could be dangerous to boats and people.
Labeling the logger with the title of your project or posting
signs in the area can inform the public about the study.
Flowing waters are variable
throughout the year and can
change even on a daily basis.
A logger must be positioned at
an adequate depth so that it is
always underwater.
5
Tips
•	Develop your anchoring protocol carefully, and be sure to take into
consideration such factors as how you might get a dozen cinder blocks out
into a lake or up a mountain stream.
•	Consider deploying more than one logger per location for data quality
purposes, or if you suspect you might lose one in a storm or flood.
•	Keep in mind that some metal fasteners can corrode quickly, especially in
marine environments.
•	Think about sending two people, instead of one, into the field to locate
deployed loggers as this can save time over one person searching alone.
This is especially true if a third party deployed the loggers, if they have been
deployed for a few months, or if vegetation is heavy or the substrate is rocky.
Useful equipment
Following is a list of items that researchers have found useful during logger
deployment and retrieval:
Written deployment protocol
– note any modifications at field sites
Securing materials
– cable ties (zip ties), wire, cable,
wooden stakes, epoxy, nylon cord
Anchors
– cinder blocks, bricks, dive weights,
metal stakes, rebar, sand screws, sand
pins, mallet or sledge hammer
Tools for removing debris
- ax, machete, rake, hoe, diving knife,
wire cutters, heavy-duty scissors, knife
Surveyor flagging
Digital or film camera
Laptop computer
Data shuttle (available from some
logger manufacturers)
Hand-held GPS
Watch
Maps, aerial photos
Waterproof field notebook
Pencils
Boat, raft, float for holding
equipment
Rubber boots, waders, scuba or
snorkeling gear
Personal
– warm and dry clothing, sunscreen,
insect repellant, appropriate outerwear,
cell phone or radio, water and food
6
Data retrieval and analysis
After temperature data has been collected for a period of time, the next steps
involve retrieving, offloading, and analyzing the collected data.
In the past, retrieving data from underwater temperature loggers meant bringing
the loggers back to an office computer, or taking a laptop into the field and
risking water damage. Today there are loggers available that can transmit data
optically to a waterproof pocket-sized data shuttle. Shuttles provide safe, easy
offload and transfer of data, while allowing loggers to remain in their deployment
location where they can be re-launched, without any data gaps.
Once the data is uploaded to a computer, it can be QA/QC’d, combined with
other data, and then analyzed using the data logger software, or exported into
another program, such as Excel. Typically, logger software applications allow
the user to quickly and easily generate graphs over the given data collection
period.
Offloading data to a waterproof shuttle
7
Capabilities to look for
There are a number of features and capabilities to look for when evaluating
underwater temperature loggers.
First, it is important to make sure that the logger has a rugged, fully-sealed
enclosure that will withstand years of use in challenging conditions. Check
device temperature and depth ranges, and ask about saltwater deployment, if
applicable. For example, stainless steel will corrode when used for long-term
saltwater deployment. Protective boots are available from some manufacturers.
Secondly, make sure the logger offers suitable options for offloading data at
field sites. Dedicated data shuttles allow users to conveniently offload data at
field sites without having to worry about moisture getting into a laptop computer.
Optical data transfer capability means that data can be downloaded even when
the logger is wet.
Depending on temperature measurement accuracy requirements and legal
requirements, it may be important to choose an underwater data logger from a
manufacturer that offers NIST (National Institute of Standards & Technology)
testing and certification services. These manufacturers can provide a certificate
that indicates the logger’s temperature accuracy versus a NIST-traceable
standard.
It’s also a good idea to look for loggers that use non-volatile memory that retains
data even if battery-power is lost.
Finally, the supplied data logger software
should enable you to quickly and easily
perform tasks such as configuring the logger,
and offloading data. If you have multiple
loggers to deploy, software features that
allow you to batch configure and export data
can save a lot of time. The software should
also offer powerful data plotting capabilities,
and enable you to easily export data to other
programs for analysis. Also consider the
operating platforms your users have; you
may need software that is supported by both
Windows and Macintosh operating systems.
If you have multiple loggers to
deploy, software features that
allow you to batch configure
and export data can save a lot
of time.
8
Conclusion
As the demand for water temperature monitoring grows, so too will the need
for instruments that make the process faster, cheaper, and more accurate.
Underwater data loggers are the instruments of choice among researchers and
resource managers because of their 24/7 operation, high accuracy, ease-of-use,
and computer-based analysis and reporting capabilities.
About Onset
Onset is a leading supplier of data logger and monitoring solutions used
to measure, record and manage data for improving the environment and
preserving the quality of temperature-sensitive products. Based on Cape Cod,
Massachusetts, Onset has been designing and manufacturing its products on
site since the company’s founding in 1981.
Visit Onset on the web at www.onsetcomp.com.
9
Sales (8am to 5pm ET, Monday through Friday)
Email sales@onsetcomp.com
Call 508-759-9500
In US call toll free 800-564-4377
Fax 508-759-9100
Technical Support (8am to 8pm ET, Monday through Friday)
Email loggerhelp@onsetcomp.com
Call 508-759-9500
In US call toll free 877-564-4377
Onset Computer Corporation
470 MacArthur Blvd.
Bourne, MA 02532
Monitoring Wetlands with Data Loggers: A Best
Practices Guide
Wetlands act as a natural filter for polluted water and thus
play an essential role in water quality protection. They serve
as floodwater storage to help minimize erosion, and create
a habitat for many fish and wildlife.
While a variety of factors have decreased the number of
wetlands in the U.S. by half since 1950, many organizations
are restoring wetlands back to their original flourishing
ecosystems. To ensure success, it is necessary to monitor
wetland factors such as water level, temperature, and
rainfall.
This guide shares field-proven best practices for
configuring, launching and deploying portable data loggers
in wetland monitoring applications. A range of data logger
types is covered, and tips are provided on logger installation
and maintenance.
Choosing A Water Level Logger: 5 Things You Should
Know
This paper provides hydrology, ecology, stormwater, and
waterworks professionals with valuable tips on how to
evaluate specific water level data loggers, and points out
key factors to be aware of during the product selection
process.
Choosing a Temperature Data Logger
This paper provides guidance on features to consider when
choosing a temperature data logger, including accuracy
requirements, data access needs, software packages, and
power requirements. It also includes real-world application
examples illustrating how users have incorporated portable
data loggers into their temperature monitoring projects.
Whether you are an experienced data logger user or just
getting started, this guide can help you choose the ideal
temperature logger for your application.
Data Logger Basics
In today’s data-driven world of satellite uplinks, wireless
networks, and the Internet, it is common to hear the terms
“data logging” and “data loggers” and not really have a firm
grasp of what they are.
Most people have a vague idea that data logging involves
electronically collecting information about the status of
something in the environment, such as temperature, relative
humidity, or energy use. They’re right, but that’s just a small
view of what data logging is.
In the fields of building performance and environmental
research, everyone seems to be using data loggers. But
what are they, and why are they useful?
This guide will introduce you to the wide world of electronic
data loggers and data logging.
Other informational resources available from Onset:
Access our full resources library at:
www.onsetcomp.com/learning
Copyright© 2016, Onset Computer Corporation. All information in this document is subject to change without notice. Onset and HOBO are registered trademarks of Onset Computer Corporation.
All other trademarks are the property of their respective owners. All rights reserved. Printed in the USA. Lit. No. MKT1178-1016
Onset Computer
Corporation
470 MacArthur Blvd.
Bourne, MA 02532
Fax: 508-759-9100
1-800-LOGGERS
(1-800-564-4377)
www.onsetcomp.com

More Related Content

PDF
Iso c1 chilled-water-installation-guide_0619
PPTX
BARCELONA 54 ENRIC SAGNIER VILLAVECCHIA MODERN ARCHITECTURE - ENGLISH
PDF
Construction Industry Review 10 -2014
PDF
The secret garden
PPT
Lean Startup: an introduction
PDF
Georg nietsch-gutefrage.net
PDF
Convencion discapacidad
PPT
Presentacion Unitecnica
Iso c1 chilled-water-installation-guide_0619
BARCELONA 54 ENRIC SAGNIER VILLAVECCHIA MODERN ARCHITECTURE - ENGLISH
Construction Industry Review 10 -2014
The secret garden
Lean Startup: an introduction
Georg nietsch-gutefrage.net
Convencion discapacidad
Presentacion Unitecnica

Viewers also liked (18)

PPS
Cuando tengas las manos
PDF
The 2011 Top 100 Global Brands and Their App Store Status
PPT
PDF
O camiño-dos-faros.-IV Curso de Verano Turismo UDC
DOCX
Tugas imk chapter 2
PPTX
Sistemas de videovigilancia
PDF
IT Infra World Infrastructure simularities 2016
PDF
eFinancials12 - David Versteeg - My Private CFO
PPTX
Alzheimer Tampico
PDF
Journal chinois france Kan zhong guo Regards sur la Chine N°280 2013-01-16
PDF
Banca y ahorro
PDF
Estado de buzones funcionarios 2013
PPTX
Dp act11 20121206 proyecto final
PPT
e-MAGUBOL Projectes
PPTX
Historia encadenada isabel villafranca
PDF
Praktische Erfahrungen zu Bund- und EU-Fördermaßnahmen für industrielle Forsc...
PDF
L'automédication étude - vanksen
PPTX
DESIDERI E BISOGNI Workshop Camplus Bologna 12-11-13
Cuando tengas las manos
The 2011 Top 100 Global Brands and Their App Store Status
O camiño-dos-faros.-IV Curso de Verano Turismo UDC
Tugas imk chapter 2
Sistemas de videovigilancia
IT Infra World Infrastructure simularities 2016
eFinancials12 - David Versteeg - My Private CFO
Alzheimer Tampico
Journal chinois france Kan zhong guo Regards sur la Chine N°280 2013-01-16
Banca y ahorro
Estado de buzones funcionarios 2013
Dp act11 20121206 proyecto final
e-MAGUBOL Projectes
Historia encadenada isabel villafranca
Praktische Erfahrungen zu Bund- und EU-Fördermaßnahmen für industrielle Forsc...
L'automédication étude - vanksen
DESIDERI E BISOGNI Workshop Camplus Bologna 12-11-13
Ad

Similar to Underwater Temperature Loggers: Considerations for Selection and Deployment (20)

PPTX
Water Temperature Data Logging Webinar
PPTX
Stream Data Loggers And Diy Instructions For Protective Housings And Deployment
PDF
Onset Data Logger Basics
PPTX
Environmental Monitoring with Temperature Data Loggers.pptx
PPTX
Andy Smerdon - Fisherman Oceanographers
PDF
Choosing a conductivity salinity logger part 1 of 2
PPTX
Basic Datalogger Water Level Measurement
PPTX
Data collection and logging
PPTX
Hydrographic Surveying1.pptx
PPTX
Underwater imaging
PDF
The use of imagery in monitoring existing sub surface structures
PPTX
Hydrographic Surveying and Tides-1 in civil engineering.pptx
PDF
PPTX
microprocessor in agriculture processese
PDF
Hydrographic survey for std not print
DOCX
Reasons For Using Data Logger
PPTX
Fish Location and Detection
PPTX
CE203 -Hydrographic survey.pptx
PDF
Hydrographic Survey Technicians
Water Temperature Data Logging Webinar
Stream Data Loggers And Diy Instructions For Protective Housings And Deployment
Onset Data Logger Basics
Environmental Monitoring with Temperature Data Loggers.pptx
Andy Smerdon - Fisherman Oceanographers
Choosing a conductivity salinity logger part 1 of 2
Basic Datalogger Water Level Measurement
Data collection and logging
Hydrographic Surveying1.pptx
Underwater imaging
The use of imagery in monitoring existing sub surface structures
Hydrographic Surveying and Tides-1 in civil engineering.pptx
microprocessor in agriculture processese
Hydrographic survey for std not print
Reasons For Using Data Logger
Fish Location and Detection
CE203 -Hydrographic survey.pptx
Hydrographic Survey Technicians
Ad

More from Metrics GmbH (17)

PDF
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
PDF
Metrics GmbH: Preisliste HOBO Datenlogger
PDF
Onset HOBO Datenlogger Produktkatalog 2024
PDF
Metrics GmbH: Preisliste Onset HOBO Datenlogger
PDF
Metrics GmbH: Preisliste HOBO Datenlogger
PDF
Onset HOBO Datenlogger Produktkatalog
PDF
Onset HOBO Datenlogger Produktkatalog 2022
PDF
Onset HOBO Datenlogger Produktkatalog 2020
PDF
METRICS Produktinformation: S-WSB-M003 Windgeschwindigkeits-Smartsensor
PDF
METRICS Produktinformation: Onset S-WDA-M003 Windrichtungs-Smartsensor
PDF
METRICS Produktinformation: Onset S-THB-M00x Temperatur/rF-Smartsensor
PDF
METRICS Produktinformation: Onset S-TMB-M0xx Temperatur-Smartsensor
PDF
Onset HOBO Datenlogger Produktkatalog 2019
PDF
Onset HOBOnet Infobroschüre
PDF
Onset Guide: Bluetooth or USB Field Temp/RH Data Loggers
PDF
HOBOware Datenblatt
PDF
Auswahl eines Wasserpegel -Datenloggers
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
Metrics GmbH: Preisliste HOBO Datenlogger
Onset HOBO Datenlogger Produktkatalog 2024
Metrics GmbH: Preisliste Onset HOBO Datenlogger
Metrics GmbH: Preisliste HOBO Datenlogger
Onset HOBO Datenlogger Produktkatalog
Onset HOBO Datenlogger Produktkatalog 2022
Onset HOBO Datenlogger Produktkatalog 2020
METRICS Produktinformation: S-WSB-M003 Windgeschwindigkeits-Smartsensor
METRICS Produktinformation: Onset S-WDA-M003 Windrichtungs-Smartsensor
METRICS Produktinformation: Onset S-THB-M00x Temperatur/rF-Smartsensor
METRICS Produktinformation: Onset S-TMB-M0xx Temperatur-Smartsensor
Onset HOBO Datenlogger Produktkatalog 2019
Onset HOBOnet Infobroschüre
Onset Guide: Bluetooth or USB Field Temp/RH Data Loggers
HOBOware Datenblatt
Auswahl eines Wasserpegel -Datenloggers

Recently uploaded (20)

PDF
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
PDF
A review of recent deep learning applications in wood surface defect identifi...
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
PDF
Architecture types and enterprise applications.pdf
PDF
Transform Your ITIL® 4 & ITSM Strategy with AI in 2025.pdf
PDF
Zenith AI: Advanced Artificial Intelligence
PPTX
Chapter 5: Probability Theory and Statistics
PDF
ENT215_Completing-a-large-scale-migration-and-modernization-with-AWS.pdf
PDF
NewMind AI Weekly Chronicles – August ’25 Week III
PDF
DASA ADMISSION 2024_FirstRound_FirstRank_LastRank.pdf
PPTX
observCloud-Native Containerability and monitoring.pptx
PPT
What is a Computer? Input Devices /output devices
PDF
Unlock new opportunities with location data.pdf
PDF
Hybrid model detection and classification of lung cancer
PDF
A novel scalable deep ensemble learning framework for big data classification...
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
sustainability-14-14877-v2.pddhzftheheeeee
PPTX
Benefits of Physical activity for teenagers.pptx
PDF
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
PDF
Getting Started with Data Integration: FME Form 101
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
A review of recent deep learning applications in wood surface defect identifi...
Univ-Connecticut-ChatGPT-Presentaion.pdf
Architecture types and enterprise applications.pdf
Transform Your ITIL® 4 & ITSM Strategy with AI in 2025.pdf
Zenith AI: Advanced Artificial Intelligence
Chapter 5: Probability Theory and Statistics
ENT215_Completing-a-large-scale-migration-and-modernization-with-AWS.pdf
NewMind AI Weekly Chronicles – August ’25 Week III
DASA ADMISSION 2024_FirstRound_FirstRank_LastRank.pdf
observCloud-Native Containerability and monitoring.pptx
What is a Computer? Input Devices /output devices
Unlock new opportunities with location data.pdf
Hybrid model detection and classification of lung cancer
A novel scalable deep ensemble learning framework for big data classification...
Hindi spoken digit analysis for native and non-native speakers
sustainability-14-14877-v2.pddhzftheheeeee
Benefits of Physical activity for teenagers.pptx
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
Getting Started with Data Integration: FME Form 101

Underwater Temperature Loggers: Considerations for Selection and Deployment

  • 1. Underwater Temperature Loggers Considerations for Selection and Deployment Metrics GmbH • Elberfelder Str. 19-21 • 58095 Hagen Telefon: 02331 3483086 • Telefax: 02331 3483088 E-Mail: [email protected] • www.metrics24.de
  • 2. Introduction Researchers and resource managers working in the world’s rivers, lakes, and oceans often need to monitor water temperature over time. Whether they are studying coral reef bleaching, assessing industrial thermal loading in lakes, modeling freshwater fish populations, or developing marine technology, users must have temperature data collection methods that are accurate, reliable, and practical for their particular field sites and studies. Most researchers today rely on electronic underwater temperature logging devices for their monitoring needs, rather than on human data collection. The latest of these loggers are small, rugged, inexpensive, and easy to use. These battery-powered devices can be programmed to gather data for months or years at a time and can withstand an extensive range of environmental conditions, including wide temperature fluctuations, rushing rocky streams, and ocean storms. This report provides general information about monitoring water temperature, and serves as a guide to selecting underwater temperature loggers. It also identifies some of the challenges specific to particular field sites, and provides tips on deploying loggers in such environments. 1
  • 3. Data loggers for monitoring Most researchers turn to underwater temperature data loggers to address their monitoring needs. These devices are low-cost, compact instruments with built-in processors, high-accuracy temperature sensing, and battery power in a rugged enclosure designed for long-term underwater deployment. They range from cigar- sized units to units the size of a short stack of quarters, typically with anchoring holes at one end. The latest models feature precision sensors that can measure water temperatures ranging from 0°C to 50°C (32°F to 122°F) in plastic housings and from 0°C to 125°C (32°F to 257°F) in stainless steel or titanium housings. Typically, underwater data loggers are deployed for months at a time, collecting temperature data at user-defined intervals and storing it digitally into logger memory. By operating in a continuous, 24/7 monitoring mode, underwater loggers eliminate many of the hassles of traditional monitoring methods. And, because the devices are typically inexpensive, users are often able to deploy loggers at more points in a water body. Underwater data loggers also simplify the process of reporting data. Instead of having to manually record times and temperatures, users can simply offload the logger data to a laptop computer and create detailed graphs or tables with the click of a mouse button. The charts can be easily printed or the data can be exported to other software applications as necessary. 2
  • 4. Using underwater temperature data loggers While specific logger operating procedures vary among manufacturers, the process of using underwater temperature loggers is relatively straightforward and involves three main phases: logger configuration and launch; deployment; and data processing (data retrieval, QA/QC, integration into a database, and analysis). Configuration and launch A logger is typically configured by connecting it to a computer (with a cable or base station) and making a number of selections: • Logging interval – This indicates how often the logger will take a water temperature measurement. The frequency of this interval will determine the maximum deployment time for the device. • Logger start time – This allows the user to start the logger immediately or postpone it until a specific date and time. Once these selections are made, the user simply clicks a start button in the logger software and the device is ready to start monitoring. Basic deployment of a HOBO Pendant series water temperature data logger 3
  • 5. Deployment Several steps are involved in deploying an underwater data logger, including site selection, anchoring the logger, documenting logger location, and retrieval. See following pages for specific field tips. • Site selection – This refers to the particular location in a body of water where temperature sampling is needed. Choose a site with good mixing, such as the turbulent area below a rock. Also make sure that the location will still be submerged at the low water point, and consider potential impact from moving debris. • Anchoring the logger – There are a number of ways to secure underwater data loggers in still, flowing, and marine waters. Some users tether a logger to a cement block or brick using nylon cord, whereas others choose to drive a rebar stake into the streambed or shoreline and tie or clamp a logger to the stake. For deepwater deployment, users usually use plastic cable ties to attach a logger to a mooring line or sand screw. See following pages for more tips specific to certain environments. For any deployment, users should think about potential natural and human factors that might dislodge or damage a logger, and consider protecting or camouflaging the device as necessary. Also consider whether you want to read out the logger’s data during deployment. In that case, you can attach the device with a tether line so it can be pulled up. • Documenting logger location – To ensure successful retrieval of underwater data loggers, it is important to document the specific location of each one during deployment. This is especially important if more than one person is working with the loggers. Documenting location in at least two ways is recommended, and can be done by taking a photograph of each monitoring site, marking the location on a map or aerial photograph, entering GPS coordinates, and using words to describe the location in a data book. Affixing a “please return to” label to the logger is also a good idea, in the uncommon event that a logger becomes dislodged. Cinder block data logger anchoring method For any deployment, users should think about potential natural and human factors that might dislodge or damage a logger, and consider protecting or camouflaging the device as necessary. 4
  • 6. From the field: Tips for deploying underwater temperature loggers Loggers have been launched in a wide variety of field conditions worldwide, and researchers have gained experience in making sure their devices stay put. Here are some notes from the field and factors to consider when deploying loggers in specific environments: Stream/river/or other shallow deployment Flowing waters are variable throughout the year and can change even on a daily basis. A logger must be positioned at an adequate depth so that it is always underwater. When choosing sites, take into account incoming tributaries, human- generated thermal pollution (measure upstream and downstream of inlet), and shading (for sunny sites that are shallow it may be necessary to use a white protective boot or paint on the logger in order to minimize solar heating). In rocky streams and rivers, heavy-duty garden tools are useful for shifting rocks during logger deployment and retrieval. Ocean and lake deployment (deep water) Wave action, currents, and storms are important considerations when securing data loggers in deep waters. Some users have been successful in anchoring loggers to mooring lines on sand screws or pins (widely available at boating equipment suppliers) driven into solid substrate. Some users attach the logger to the screw or pin itself, and recommend using more than one cable tie in case one breaks loose. In marine environments, a scraping tool is useful if encrusting organisms colonize the logger. In particularly rough conditions, it is wise to secure the entire body of the logger, rather than just one end. Intertidal deployment Intertidal environments are alternately submerged in seawater and exposed to the air. They are also subject to wide temperature fluctuations, so logger anchoring materials must be able to withstand such varying conditions. Putty epoxy that cures underwater and in air has been used successfully to anchor loggers to rocks in the intertidal zone. Areas of heavy human use Humans use water bodies commercially and recreationally, and having curious people around field sites can be a challenge. In addition to boating and fishing activity, vandalism can potentially damage or dislodge a temperature logger. Camouflage is a necessity, and can be achieved by burying the logger under rocks or gravel, buying and painting a protective boot for the logger (boots are available from most manufacturers), or enclosing the logger in a secure wire cage. Also, avoid using mounting stakes or posts in areas where they could be dangerous to boats and people. Labeling the logger with the title of your project or posting signs in the area can inform the public about the study. Flowing waters are variable throughout the year and can change even on a daily basis. A logger must be positioned at an adequate depth so that it is always underwater. 5
  • 7. Tips • Develop your anchoring protocol carefully, and be sure to take into consideration such factors as how you might get a dozen cinder blocks out into a lake or up a mountain stream. • Consider deploying more than one logger per location for data quality purposes, or if you suspect you might lose one in a storm or flood. • Keep in mind that some metal fasteners can corrode quickly, especially in marine environments. • Think about sending two people, instead of one, into the field to locate deployed loggers as this can save time over one person searching alone. This is especially true if a third party deployed the loggers, if they have been deployed for a few months, or if vegetation is heavy or the substrate is rocky. Useful equipment Following is a list of items that researchers have found useful during logger deployment and retrieval: Written deployment protocol – note any modifications at field sites Securing materials – cable ties (zip ties), wire, cable, wooden stakes, epoxy, nylon cord Anchors – cinder blocks, bricks, dive weights, metal stakes, rebar, sand screws, sand pins, mallet or sledge hammer Tools for removing debris - ax, machete, rake, hoe, diving knife, wire cutters, heavy-duty scissors, knife Surveyor flagging Digital or film camera Laptop computer Data shuttle (available from some logger manufacturers) Hand-held GPS Watch Maps, aerial photos Waterproof field notebook Pencils Boat, raft, float for holding equipment Rubber boots, waders, scuba or snorkeling gear Personal – warm and dry clothing, sunscreen, insect repellant, appropriate outerwear, cell phone or radio, water and food 6
  • 8. Data retrieval and analysis After temperature data has been collected for a period of time, the next steps involve retrieving, offloading, and analyzing the collected data. In the past, retrieving data from underwater temperature loggers meant bringing the loggers back to an office computer, or taking a laptop into the field and risking water damage. Today there are loggers available that can transmit data optically to a waterproof pocket-sized data shuttle. Shuttles provide safe, easy offload and transfer of data, while allowing loggers to remain in their deployment location where they can be re-launched, without any data gaps. Once the data is uploaded to a computer, it can be QA/QC’d, combined with other data, and then analyzed using the data logger software, or exported into another program, such as Excel. Typically, logger software applications allow the user to quickly and easily generate graphs over the given data collection period. Offloading data to a waterproof shuttle 7
  • 9. Capabilities to look for There are a number of features and capabilities to look for when evaluating underwater temperature loggers. First, it is important to make sure that the logger has a rugged, fully-sealed enclosure that will withstand years of use in challenging conditions. Check device temperature and depth ranges, and ask about saltwater deployment, if applicable. For example, stainless steel will corrode when used for long-term saltwater deployment. Protective boots are available from some manufacturers. Secondly, make sure the logger offers suitable options for offloading data at field sites. Dedicated data shuttles allow users to conveniently offload data at field sites without having to worry about moisture getting into a laptop computer. Optical data transfer capability means that data can be downloaded even when the logger is wet. Depending on temperature measurement accuracy requirements and legal requirements, it may be important to choose an underwater data logger from a manufacturer that offers NIST (National Institute of Standards & Technology) testing and certification services. These manufacturers can provide a certificate that indicates the logger’s temperature accuracy versus a NIST-traceable standard. It’s also a good idea to look for loggers that use non-volatile memory that retains data even if battery-power is lost. Finally, the supplied data logger software should enable you to quickly and easily perform tasks such as configuring the logger, and offloading data. If you have multiple loggers to deploy, software features that allow you to batch configure and export data can save a lot of time. The software should also offer powerful data plotting capabilities, and enable you to easily export data to other programs for analysis. Also consider the operating platforms your users have; you may need software that is supported by both Windows and Macintosh operating systems. If you have multiple loggers to deploy, software features that allow you to batch configure and export data can save a lot of time. 8
  • 10. Conclusion As the demand for water temperature monitoring grows, so too will the need for instruments that make the process faster, cheaper, and more accurate. Underwater data loggers are the instruments of choice among researchers and resource managers because of their 24/7 operation, high accuracy, ease-of-use, and computer-based analysis and reporting capabilities. About Onset Onset is a leading supplier of data logger and monitoring solutions used to measure, record and manage data for improving the environment and preserving the quality of temperature-sensitive products. Based on Cape Cod, Massachusetts, Onset has been designing and manufacturing its products on site since the company’s founding in 1981. Visit Onset on the web at www.onsetcomp.com. 9 Sales (8am to 5pm ET, Monday through Friday) Email [email protected] Call 508-759-9500 In US call toll free 800-564-4377 Fax 508-759-9100 Technical Support (8am to 8pm ET, Monday through Friday) Email [email protected] Call 508-759-9500 In US call toll free 877-564-4377 Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA 02532
  • 11. Monitoring Wetlands with Data Loggers: A Best Practices Guide Wetlands act as a natural filter for polluted water and thus play an essential role in water quality protection. They serve as floodwater storage to help minimize erosion, and create a habitat for many fish and wildlife. While a variety of factors have decreased the number of wetlands in the U.S. by half since 1950, many organizations are restoring wetlands back to their original flourishing ecosystems. To ensure success, it is necessary to monitor wetland factors such as water level, temperature, and rainfall. This guide shares field-proven best practices for configuring, launching and deploying portable data loggers in wetland monitoring applications. A range of data logger types is covered, and tips are provided on logger installation and maintenance. Choosing A Water Level Logger: 5 Things You Should Know This paper provides hydrology, ecology, stormwater, and waterworks professionals with valuable tips on how to evaluate specific water level data loggers, and points out key factors to be aware of during the product selection process. Choosing a Temperature Data Logger This paper provides guidance on features to consider when choosing a temperature data logger, including accuracy requirements, data access needs, software packages, and power requirements. It also includes real-world application examples illustrating how users have incorporated portable data loggers into their temperature monitoring projects. Whether you are an experienced data logger user or just getting started, this guide can help you choose the ideal temperature logger for your application. Data Logger Basics In today’s data-driven world of satellite uplinks, wireless networks, and the Internet, it is common to hear the terms “data logging” and “data loggers” and not really have a firm grasp of what they are. Most people have a vague idea that data logging involves electronically collecting information about the status of something in the environment, such as temperature, relative humidity, or energy use. They’re right, but that’s just a small view of what data logging is. In the fields of building performance and environmental research, everyone seems to be using data loggers. But what are they, and why are they useful? This guide will introduce you to the wide world of electronic data loggers and data logging. Other informational resources available from Onset: Access our full resources library at: www.onsetcomp.com/learning Copyright© 2016, Onset Computer Corporation. All information in this document is subject to change without notice. Onset and HOBO are registered trademarks of Onset Computer Corporation. All other trademarks are the property of their respective owners. All rights reserved. Printed in the USA. Lit. No. MKT1178-1016
  • 12. Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA 02532 Fax: 508-759-9100 1-800-LOGGERS (1-800-564-4377) www.onsetcomp.com