LIMIT TEST
 The limit test involve simple comparisons of
opalescence, turbidity, or color with standard.
 These are semi-qualitative reactions in which extent of
impurities present can be estimated by comparing visible
reaction response of the test and standard.
 By this way, extent of reaction is readily determined by direct
comparison of test solution with standard. So pharmacopoeia
prefers comparison methods.
4/5/2022 15
Aim: To perform the limit test for sulphate /Chloride
/Lead/Heavy Metal on a given sample as per Indian
pharmacopoeia.
Requirement:
4/5/2022 16
4/5/2022 17
4/5/2022 18
4/5/2022 19
20
4/5/2022
Test sample Standard compound
Specific weight of compound
is dissolved in water
or solution is prepared as
directed in the pharmacopoeia
and transferred in Nessler
cylinder
Take 1 ml of 0.05845 % W/V
solution of sodium chloride in
Nessler cylinder
Add 1 ml of nitric acid Add 1 ml of nitric acid
Dilute to 50 ml in Nessler cylinder Dilute to 50 ml in Nessler cylinder
Add 1 ml of AgNO3 solution Add 1 ml of AgNO3 solution
Keep aside for 5 min Keep aside for 5 min
Observe the
Opalescence/Turbidity
Observe the Opalescence/Turbidity
4/5/2022 21
Observation:
The opalescence produce in sample solution should not be greater
than standard solution. If opalescence produces in sample solution
is less than the standard solution, the sample will pass the limit test
of chloride and visa versa.
Reasons:
Nitric acid is added in the limit test of chloride to make solution
acidic and helps silver chloride precipitate to make solution turbid
at the end of process as Dilute HNO3 is insoluble inAgCl.
4/5/2022 22
4/5/2022 23
LIMIT TEST SULPHATE
4/5/2022 24
Principle:
Limit test of sulphate is based on the reaction of soluble sulphate with barium
chloride in presence of dilute hydrochloric acid to form barium sulphate
which appears as solid particles (turbidity) in the solution.
SO4 + BaCl2 --------------------------- BaSO4 + 2Cl
-2 -
Potassium sulphate has been added to increase the sensitivity of the test.
4/5/2022
4/5/2022 26
Observation:
The turbidity produce in sample solution should not be greater
than standard solution. If turbidity produces in sample solution
is less than the standard solution, the sample will pass the limit
test of sulphate and vice versa.
Reasons:
Hydrochloric acid helps to make solution acidic.
Potassium sulphate is used to increase the sensitivity of the test
by giving ionic
concentration in the reagent.
Alcohol helps to prevent super saturation and so produces a
more uniform opalescence.
4/5/2022 27
Limit test for IRON:
 Limit test of Iron is based on the reaction of iron in ammonical solution with
thioglycollic acid in presence of citric acid to form iron thioglycolate (Ferrous
thioglycolate complex) which produces pale pink to deep reddish purple color in
alkaline media.
 Thioglycolic acid is used as reducing agent.
 The color of the Ferrous thioglycolate complex fades in the presence of air due to
oxidation.
 Also, the color is destroyed in presence of oxidizing agents and strong alkalis.
 The purple color is developed only in alkaline media. So ammonia solution is used.
 But ammonia reacts with iron, forms precipitate of ferrous hydroxide.
 Thus citric acid is used which prevents the precipitate of iron with Ammonia by forming
a complex with iron as iron citrate.
4/5/2022 28
Test sample Standard compound
Sample is dissolved in specific
amount
of water and then volume is
made up to 40 ml
2 ml of standard solution of iron
diluted
with water upto 40 ml
Add 2 ml of 20 % w/v of
citric acid
(iron free)
Add 2 ml of 20 % w/v of
citric acid
(iron free)
Add 2 drops of thioglycollic acid Add 2 drops of thioglycollic acid
Add ammonia to make the
solution
alkaline and adjust the volume to
50 ml
Add ammonia to make the
solution
alkaline and adjust the volume to
50 ml
Keep aside for 5 min Keep aside for 5 min
Color developed is viewed
vertically
and compared with standard
solution
Color developed is viewed
vertically and
compared with standard solution
Procedure:
Note:All the reagents used in the limit test for Iron should themselves be iron free.
4/5/2022 29
Observation:
The purple color produce in sample solution should not be
greater than standard solution. If purple color produces in
sample solution is less than the standard solution, the sample
will pass the limit test of iron and vice versa.
Reasons:
 Citric acid forms complex with metal cation and helps
precipitation of iron by ammonia by forming a complex with
it.
 Thioglycolic acid helps to oxidize iron (II) to iron (III).
 Ammonia is added to make solution alkaline. The pale pink
color is visible only in the alkaline media. The color is not
visible in acidic media as ferrous thioglycolate complex
decomposes in high acidic media.
4/5/2022 30
Limit test for Arsenic:
Arsenic is a well known undesirable and harmful impurity
which is present in medicinal
substances.
Pharmacopoeial method is based on the Gutzeit test.
All the special reagents used in the limit test for Arsenic are
marked and distinguished by letter ‘As T’, which means that
they all should be Arsenic free and should themselves
conform to the test for Arsenic.
4/5/2022 31
Principle:
Limit test of Arsenic is based on the reaction of arsenic gas with hydrogen ion to form
yellow stain on mercuric chloride paper in presence of reducing agents like potassium
iodide.
It is also called as Gutzeit test and requires special apparatus.
 Arsenic, present as arsenic acid (H3AsO4) in the sample is reduced to arsenious acid
(H3AsO3) by reducing agents like potassium iodide, stannous acid, zinc, hydrochloric acid,
etc. Arsenious acid is further reduced to arsine (gas) (AsH3) by hydrogen and reacts with
mercuric chloride paper to give a yellow stain.
Substance + dil HCl ------------------------- H3AsO4
(containsArsenic impurity)
Arsenic acid
 H3AsO4 +
Arsenic acid
H2SnO2 -------------------→ H3AsO3 + H2SnO3
Arsenious acid
H3AsO3 + 6[H] ---------------------→AsH3 + 3H2O
Arsenious acid nascent hydrogen Arsine gas
The depth of yellow stain on mercuric chloride paper will depend upon the quantity of
arsenic present in the sample. 4/5/2022 32
When the sample is dissolved in acid, the Arsenic present in the sample
gets converted to Arsenic acid.
By action of reducing agents like Potassium iodide, stannous acid etc.,
Arsenic acid gets reduced to arsenious acid.
The nascent hydrogen formed during the reaction, further reduces
Arsenious acid to Arsine gas, which reacts with mercuric chloride paper,
giving a yellow stain.
4/5/2022 33
4/5/2022 34
Reasons:
Stannous chloride is used for complete evolution of arsine.
Zinc, potassium iodide and stannous chloride is used as a reducing
agent.
Hydrochloride acid is used to make the solution acidic
Lead acetate paper are used to trap any hydrogen sulphide which
may be evolved along with arsine.
4/5/2022 35
Use of stannated Hydrochloric acid:
If pure zinc and HCl are used, the steady evolution of gas does not occur. This
produces improper stain (e.g slow evolution produces short but intense stain
while rapid evolution of gas produces long but diffused stain.)
So, to get steady evolution of gas, stannated hydrochloric acid is used.
Use of LeadAcetate solution:
H2S gas may be formed during the experiment as zinc contains sulphides as
impurities. It gives black stain to HgCl2 paper and so will interfere the test.
Hence, gases evolved are passed through cotton wool plug moistened with
lead acetate, where H2S gas is trapped as PbS.
Use of Potassium iodide:
KI is converted to HI which brings about reduction of unreacted pentavalent
arsenic to trivalent Arsenic. Thus, reproducible results can be obtained. If it is
not used then some pentavalentArsenic may remain unreacted.
4/5/2022 36
Limit test for heavy metals
 The limit test for heavy metals is designed to determine the content of metallic
impurities that are coloured by hydrogen sulphide or sodium sulphide under the
condition of the test should not exceed the heavy metal limits given under the
individual monograph.
 The heavy metals (metallic impurities) may be iron, copper, lead, nickel, cobalt,
bismuth, antimony etc.. The limit for heavy metals is indicated in the individual
monograph in term of ppm of lead i.e. the parts of lead per million parts of the
substance being examined
 In substances the proportion of any such impurity (Heavy metals) has been expressed
as the quantity of lead required to produce a color of equal depth as in a standard
comparison solution having a definite quantity of lead nitrate.
 The quantity is stated as the heavy metal limit and is expressed as parts of
lead (by
weight) per million parts of the test substance.
 The limit test for heavy metals has been based upon the reaction of the
metal ion with hydrogen sulphide, under the prescribed conditions of the test
causing the formation of metal sulphides.
 These remain distributed in colloidal state, and give rise to a brownish coloration.
4/5/2022 37
 I.P limit for heavy metals in 20 ppm.
 The test solution is compared with a standard prepared using a lead solution
(as the heavy metal).The metallic impurities in substance are expressed as
parts of lead per million parts of substance.
 IP has adopted 3 methods for this:
 Method I: The method is applicable for the samples which give clear
colourless solutions under specified conditions of test.
 Method II: The method is applicable for the samples which DO
NOT give clear colourless solutions under specified
conditions of test.
 Method III: Used for substances which give clear colourless
solutions in sodium hydroxide medium.
38
4/5/2022
Limit test for lead:
Lead is a most undesirable impurity in medical
compounds
and comes through use of sulphuric acid, lead lined
apparatus and glass bottles use for storage of
chemicals.
Principle:
Limit test of lead is based on the reaction of lead and
diphenyl thiocabazone (dithizone) in alkaline solution to
form lead dithizone complex which is red in color.
4/5/2022
 Dithizone in chloroform, is able to extract lead from alkaline aqueous solutions as
a lead dithizone complex (Red in colour)
 The original dithizone is having a green colour in chloroform while the lead-
dithizone is having a violet color.So, resulting color at the end of the process is
read.
 The intensity of the color of complex is dependant upon the amount of lead in
the solution.
 The color of the lead-dithizone complex in chloroform has been compared with a
standard volume of lead solution, treated in the same manner.
 In this method, the lead present as an impurity in the substances, gets separated by
extracting an alkaline solution with a dithizone extraction solution.
 The interference and influence of the other metal ions has been eliminated by
adjusting the optimum pH for the extraction by employing Ammonium
citrate/ potassium cyanide.
40
4/5/2022
 Observation:
The intensity of the color of complex, is depends on the amount of lead
in the solution. The color produced in sample solution should not be
greater than standard solution. If color produces in sample solution is less
than the standard solution, the sample will pass the limit test of lead and
vice versa.
citrate, potassium cyanide,
Reasons:
 Ammonium
hydrochloride
hydroxylamine
is used to make pH optimum so interference and
influence of other impurities have been eliminated.
 Phenol red is used as indicator to develop the color at the end of process
Lead present as an impurities in the substance, gets separated by
extracting an alkaline solution with a dithizone extraction solution.
4/5/2022 41
4/5/2022 42
4/5/2022 43

Unit 1 PHARMACEUTICAL INORGANIC CHEMISTRY

  • 1.
  • 2.
    UNIT 1: HISTORYOF PHARMACOPOEIA 4/5/2022 2
  • 3.
  • 4.
  • 5.
  • 6.
  • 7.
  • 8.
  • 9.
  • 10.
  • 11.
  • 12.
  • 13.
  • 14.
  • 15.
    LIMIT TEST  Thelimit test involve simple comparisons of opalescence, turbidity, or color with standard.  These are semi-qualitative reactions in which extent of impurities present can be estimated by comparing visible reaction response of the test and standard.  By this way, extent of reaction is readily determined by direct comparison of test solution with standard. So pharmacopoeia prefers comparison methods. 4/5/2022 15
  • 16.
    Aim: To performthe limit test for sulphate /Chloride /Lead/Heavy Metal on a given sample as per Indian pharmacopoeia. Requirement: 4/5/2022 16
  • 17.
  • 18.
  • 19.
  • 20.
  • 21.
    Test sample Standardcompound Specific weight of compound is dissolved in water or solution is prepared as directed in the pharmacopoeia and transferred in Nessler cylinder Take 1 ml of 0.05845 % W/V solution of sodium chloride in Nessler cylinder Add 1 ml of nitric acid Add 1 ml of nitric acid Dilute to 50 ml in Nessler cylinder Dilute to 50 ml in Nessler cylinder Add 1 ml of AgNO3 solution Add 1 ml of AgNO3 solution Keep aside for 5 min Keep aside for 5 min Observe the Opalescence/Turbidity Observe the Opalescence/Turbidity 4/5/2022 21
  • 22.
    Observation: The opalescence producein sample solution should not be greater than standard solution. If opalescence produces in sample solution is less than the standard solution, the sample will pass the limit test of chloride and visa versa. Reasons: Nitric acid is added in the limit test of chloride to make solution acidic and helps silver chloride precipitate to make solution turbid at the end of process as Dilute HNO3 is insoluble inAgCl. 4/5/2022 22
  • 23.
  • 24.
  • 25.
    Principle: Limit test ofsulphate is based on the reaction of soluble sulphate with barium chloride in presence of dilute hydrochloric acid to form barium sulphate which appears as solid particles (turbidity) in the solution. SO4 + BaCl2 --------------------------- BaSO4 + 2Cl -2 - Potassium sulphate has been added to increase the sensitivity of the test. 4/5/2022
  • 26.
  • 27.
    Observation: The turbidity producein sample solution should not be greater than standard solution. If turbidity produces in sample solution is less than the standard solution, the sample will pass the limit test of sulphate and vice versa. Reasons: Hydrochloric acid helps to make solution acidic. Potassium sulphate is used to increase the sensitivity of the test by giving ionic concentration in the reagent. Alcohol helps to prevent super saturation and so produces a more uniform opalescence. 4/5/2022 27
  • 28.
    Limit test forIRON:  Limit test of Iron is based on the reaction of iron in ammonical solution with thioglycollic acid in presence of citric acid to form iron thioglycolate (Ferrous thioglycolate complex) which produces pale pink to deep reddish purple color in alkaline media.  Thioglycolic acid is used as reducing agent.  The color of the Ferrous thioglycolate complex fades in the presence of air due to oxidation.  Also, the color is destroyed in presence of oxidizing agents and strong alkalis.  The purple color is developed only in alkaline media. So ammonia solution is used.  But ammonia reacts with iron, forms precipitate of ferrous hydroxide.  Thus citric acid is used which prevents the precipitate of iron with Ammonia by forming a complex with iron as iron citrate. 4/5/2022 28
  • 29.
    Test sample Standardcompound Sample is dissolved in specific amount of water and then volume is made up to 40 ml 2 ml of standard solution of iron diluted with water upto 40 ml Add 2 ml of 20 % w/v of citric acid (iron free) Add 2 ml of 20 % w/v of citric acid (iron free) Add 2 drops of thioglycollic acid Add 2 drops of thioglycollic acid Add ammonia to make the solution alkaline and adjust the volume to 50 ml Add ammonia to make the solution alkaline and adjust the volume to 50 ml Keep aside for 5 min Keep aside for 5 min Color developed is viewed vertically and compared with standard solution Color developed is viewed vertically and compared with standard solution Procedure: Note:All the reagents used in the limit test for Iron should themselves be iron free. 4/5/2022 29
  • 30.
    Observation: The purple colorproduce in sample solution should not be greater than standard solution. If purple color produces in sample solution is less than the standard solution, the sample will pass the limit test of iron and vice versa. Reasons:  Citric acid forms complex with metal cation and helps precipitation of iron by ammonia by forming a complex with it.  Thioglycolic acid helps to oxidize iron (II) to iron (III).  Ammonia is added to make solution alkaline. The pale pink color is visible only in the alkaline media. The color is not visible in acidic media as ferrous thioglycolate complex decomposes in high acidic media. 4/5/2022 30
  • 31.
    Limit test forArsenic: Arsenic is a well known undesirable and harmful impurity which is present in medicinal substances. Pharmacopoeial method is based on the Gutzeit test. All the special reagents used in the limit test for Arsenic are marked and distinguished by letter ‘As T’, which means that they all should be Arsenic free and should themselves conform to the test for Arsenic. 4/5/2022 31
  • 32.
    Principle: Limit test ofArsenic is based on the reaction of arsenic gas with hydrogen ion to form yellow stain on mercuric chloride paper in presence of reducing agents like potassium iodide. It is also called as Gutzeit test and requires special apparatus.  Arsenic, present as arsenic acid (H3AsO4) in the sample is reduced to arsenious acid (H3AsO3) by reducing agents like potassium iodide, stannous acid, zinc, hydrochloric acid, etc. Arsenious acid is further reduced to arsine (gas) (AsH3) by hydrogen and reacts with mercuric chloride paper to give a yellow stain. Substance + dil HCl ------------------------- H3AsO4 (containsArsenic impurity) Arsenic acid  H3AsO4 + Arsenic acid H2SnO2 -------------------→ H3AsO3 + H2SnO3 Arsenious acid H3AsO3 + 6[H] ---------------------→AsH3 + 3H2O Arsenious acid nascent hydrogen Arsine gas The depth of yellow stain on mercuric chloride paper will depend upon the quantity of arsenic present in the sample. 4/5/2022 32
  • 33.
    When the sampleis dissolved in acid, the Arsenic present in the sample gets converted to Arsenic acid. By action of reducing agents like Potassium iodide, stannous acid etc., Arsenic acid gets reduced to arsenious acid. The nascent hydrogen formed during the reaction, further reduces Arsenious acid to Arsine gas, which reacts with mercuric chloride paper, giving a yellow stain. 4/5/2022 33
  • 34.
  • 35.
    Reasons: Stannous chloride isused for complete evolution of arsine. Zinc, potassium iodide and stannous chloride is used as a reducing agent. Hydrochloride acid is used to make the solution acidic Lead acetate paper are used to trap any hydrogen sulphide which may be evolved along with arsine. 4/5/2022 35
  • 36.
    Use of stannatedHydrochloric acid: If pure zinc and HCl are used, the steady evolution of gas does not occur. This produces improper stain (e.g slow evolution produces short but intense stain while rapid evolution of gas produces long but diffused stain.) So, to get steady evolution of gas, stannated hydrochloric acid is used. Use of LeadAcetate solution: H2S gas may be formed during the experiment as zinc contains sulphides as impurities. It gives black stain to HgCl2 paper and so will interfere the test. Hence, gases evolved are passed through cotton wool plug moistened with lead acetate, where H2S gas is trapped as PbS. Use of Potassium iodide: KI is converted to HI which brings about reduction of unreacted pentavalent arsenic to trivalent Arsenic. Thus, reproducible results can be obtained. If it is not used then some pentavalentArsenic may remain unreacted. 4/5/2022 36
  • 37.
    Limit test forheavy metals  The limit test for heavy metals is designed to determine the content of metallic impurities that are coloured by hydrogen sulphide or sodium sulphide under the condition of the test should not exceed the heavy metal limits given under the individual monograph.  The heavy metals (metallic impurities) may be iron, copper, lead, nickel, cobalt, bismuth, antimony etc.. The limit for heavy metals is indicated in the individual monograph in term of ppm of lead i.e. the parts of lead per million parts of the substance being examined  In substances the proportion of any such impurity (Heavy metals) has been expressed as the quantity of lead required to produce a color of equal depth as in a standard comparison solution having a definite quantity of lead nitrate.  The quantity is stated as the heavy metal limit and is expressed as parts of lead (by weight) per million parts of the test substance.  The limit test for heavy metals has been based upon the reaction of the metal ion with hydrogen sulphide, under the prescribed conditions of the test causing the formation of metal sulphides.  These remain distributed in colloidal state, and give rise to a brownish coloration. 4/5/2022 37
  • 38.
     I.P limitfor heavy metals in 20 ppm.  The test solution is compared with a standard prepared using a lead solution (as the heavy metal).The metallic impurities in substance are expressed as parts of lead per million parts of substance.  IP has adopted 3 methods for this:  Method I: The method is applicable for the samples which give clear colourless solutions under specified conditions of test.  Method II: The method is applicable for the samples which DO NOT give clear colourless solutions under specified conditions of test.  Method III: Used for substances which give clear colourless solutions in sodium hydroxide medium. 38 4/5/2022
  • 39.
    Limit test forlead: Lead is a most undesirable impurity in medical compounds and comes through use of sulphuric acid, lead lined apparatus and glass bottles use for storage of chemicals. Principle: Limit test of lead is based on the reaction of lead and diphenyl thiocabazone (dithizone) in alkaline solution to form lead dithizone complex which is red in color. 4/5/2022
  • 40.
     Dithizone inchloroform, is able to extract lead from alkaline aqueous solutions as a lead dithizone complex (Red in colour)  The original dithizone is having a green colour in chloroform while the lead- dithizone is having a violet color.So, resulting color at the end of the process is read.  The intensity of the color of complex is dependant upon the amount of lead in the solution.  The color of the lead-dithizone complex in chloroform has been compared with a standard volume of lead solution, treated in the same manner.  In this method, the lead present as an impurity in the substances, gets separated by extracting an alkaline solution with a dithizone extraction solution.  The interference and influence of the other metal ions has been eliminated by adjusting the optimum pH for the extraction by employing Ammonium citrate/ potassium cyanide. 40 4/5/2022
  • 41.
     Observation: The intensityof the color of complex, is depends on the amount of lead in the solution. The color produced in sample solution should not be greater than standard solution. If color produces in sample solution is less than the standard solution, the sample will pass the limit test of lead and vice versa. citrate, potassium cyanide, Reasons:  Ammonium hydrochloride hydroxylamine is used to make pH optimum so interference and influence of other impurities have been eliminated.  Phenol red is used as indicator to develop the color at the end of process Lead present as an impurities in the substance, gets separated by extracting an alkaline solution with a dithizone extraction solution. 4/5/2022 41
  • 42.
  • 43.