OLCT 80 Wireless
Wireless Fixed Detector

Wireless field detector and transmitter for
detection of oxygen, combustible, toxic and
refrigerant gases in remote locations
Now Available in Wireless!

KEYBENEFITS
•

Suitable design for use in explosive 	
areas

•

Reduces installation costs by
eliminating cabling and wiring

•

Available with flameproof or

from distortion or interference

Lower Installation Costs
Eliminating the need for point-to-point wiring, the operation of the
OLCT80 wireless is as simple as one single field device communicating

intrinsic-safety sensors

•

wireless connectivity in ATEX 1 zones. Providing a range of up to 3km
the OLCT 80 utilises binding technology to ensure that the signal is free

On-board display allows
noninvasive one-man calibration

•

The new OLCT 80 model builds on an established design to provide

It can be linked via secure network 	
to monitor large remote areas

with a controller, remote display and alarm station.

Signal Processing you can Rely on
The transceivers operate at a universally accepted frequency of 2.4 GHz
and have the capability to transmit signal data from various inputs or

GASESANALYSED

serial MODBUS outputs.

H2S

O2

CO

NO2

SO2

Cl2

H2

AsH3

SiH4

HCl

NH3

PH3

O3

CH4

“

The OLCT 80 Wireless is suited for
transmitting signal data in a wide
range of industrial applications

“

NO
TECHNICALSPECIFICATION

SPECIFICATIONS ANTENNA

• Frequency band 900 MHz or 2400 MHz - to be specified

GENERAL

	

when ordering

• Low power requirement
• 1-3KM line-of-sight range
• Robust mesh network topology (option)
• Wireless connectivity in ATEX 1 zones

• Impedance : 50 Ω
• Gain 2dBi
• Power 2 watts

PERFORMANCE

• Logic: 3 dry relay contacts (Fault, Al1, Al2)
• Analogue: Standardised 4-20 mA output
• Digital: one serial RS485 output
• Signal faults: 1 < 0.5 mA
• Alarms: 2 programmable thresholds per channel

OUTPUT SIGNAL

• Operating Temp: -20°C to +55°C
• Pre-calibrated sensor
• Detected gases: Explosive or toxic gases, or O2
PHYSICAL

RELAYS

• Enclosure material: Epoxy coated aluminium
		

• 3 relays, RCT change over
• Relay rating: 2 A @250 VAC or 30 VDC
• Load resistance: 500 Ω

316 stainless steel sensor

• Weight: 4 kg
POWER

• Supply: 16 to 28 V DC optional solar panels available in

APPROVALS

	

• EEx d IIB T5 (T 100°C) for OLCT 80 with flameproof sensor
• EEx d [ia] ia IIB T4 (T 135°C) for OLCT 80 with intrinsically 	

ATEX version

• Cable entry: 4 M20 & 2 M25 cable entries
• Analogue input: 2 analog input 4-20 mA (load resistance

	

120 Ω)

• Loop impedance with OLDHAM controller:

safe sensor

• Certificate INERIS 03ATEX0240X
• Ingress protection: IP 66

128 Ω (electrochemical), 32 Ω (catalytic), 16 Ω (OLCT 80 XP IR)

POWER CONSUMPTION

• With digital link: 9 W (electrochemical) - 10 W (catalytic)
- 12.5 (IR)

• With signal output at 25mA: 9 W (electrochemical) - 10 W

	

(catalytic) - 13.2 (IR)

• With signal output set at 25 mA and activated relays:
10.4 W (electrochemical) - 11.5 W (catalytic) -14.7(IR)

11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com

Cert No. 996
ISO 9001

Wireless olct 80 datasheet 0

  • 1.
    OLCT 80 Wireless WirelessFixed Detector Wireless field detector and transmitter for detection of oxygen, combustible, toxic and refrigerant gases in remote locations Now Available in Wireless! KEYBENEFITS • Suitable design for use in explosive areas • Reduces installation costs by eliminating cabling and wiring • Available with flameproof or from distortion or interference Lower Installation Costs Eliminating the need for point-to-point wiring, the operation of the OLCT80 wireless is as simple as one single field device communicating intrinsic-safety sensors • wireless connectivity in ATEX 1 zones. Providing a range of up to 3km the OLCT 80 utilises binding technology to ensure that the signal is free On-board display allows noninvasive one-man calibration • The new OLCT 80 model builds on an established design to provide It can be linked via secure network to monitor large remote areas with a controller, remote display and alarm station. Signal Processing you can Rely on The transceivers operate at a universally accepted frequency of 2.4 GHz and have the capability to transmit signal data from various inputs or GASESANALYSED serial MODBUS outputs. H2S O2 CO NO2 SO2 Cl2 H2 AsH3 SiH4 HCl NH3 PH3 O3 CH4 “ The OLCT 80 Wireless is suited for transmitting signal data in a wide range of industrial applications “ NO
  • 2.
    TECHNICALSPECIFICATION SPECIFICATIONS ANTENNA • Frequencyband 900 MHz or 2400 MHz - to be specified GENERAL when ordering • Low power requirement • 1-3KM line-of-sight range • Robust mesh network topology (option) • Wireless connectivity in ATEX 1 zones • Impedance : 50 Ω • Gain 2dBi • Power 2 watts PERFORMANCE • Logic: 3 dry relay contacts (Fault, Al1, Al2) • Analogue: Standardised 4-20 mA output • Digital: one serial RS485 output • Signal faults: 1 < 0.5 mA • Alarms: 2 programmable thresholds per channel OUTPUT SIGNAL • Operating Temp: -20°C to +55°C • Pre-calibrated sensor • Detected gases: Explosive or toxic gases, or O2 PHYSICAL RELAYS • Enclosure material: Epoxy coated aluminium • 3 relays, RCT change over • Relay rating: 2 A @250 VAC or 30 VDC • Load resistance: 500 Ω 316 stainless steel sensor • Weight: 4 kg POWER • Supply: 16 to 28 V DC optional solar panels available in APPROVALS • EEx d IIB T5 (T 100°C) for OLCT 80 with flameproof sensor • EEx d [ia] ia IIB T4 (T 135°C) for OLCT 80 with intrinsically ATEX version • Cable entry: 4 M20 & 2 M25 cable entries • Analogue input: 2 analog input 4-20 mA (load resistance 120 Ω) • Loop impedance with OLDHAM controller: safe sensor • Certificate INERIS 03ATEX0240X • Ingress protection: IP 66 128 Ω (electrochemical), 32 Ω (catalytic), 16 Ω (OLCT 80 XP IR) POWER CONSUMPTION • With digital link: 9 W (electrochemical) - 10 W (catalytic) - 12.5 (IR) • With signal output at 25mA: 9 W (electrochemical) - 10 W (catalytic) - 13.2 (IR) • With signal output set at 25 mA and activated relays: 10.4 W (electrochemical) - 11.5 W (catalytic) -14.7(IR) 11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: [email protected] W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com Cert No. 996 ISO 9001