ENERGY BALANCE
Reference temperature = 273 K
PRE-HEATER
Inlet temperature of solution
25C
Outlet temperature of solution
60C
Qf
mCp dT
Qf
[(111.1*1.429)+(4.187*2.268)]*(298-273)
168.258
Qf
4206.4504 kJ/hr
Qp
168.258
10095.48 kJ/hr
Heat carried in
by the feed stream
25
Heat carried out
by the product stream
60
Heat to be supplied,
Qp - Qf =
Steam requirement
5889.03
( Qp - Qf )/ s
(s=2260 kJ/kg)
2.60576 kg/hr
Assuming 80% heat transfer efficiency in the equipments
Actual steam requirement, S
Streams
Reactant stream
Product stream
Steam
Total
3.25 kg/hr
Energy inlet (kJ/hr)
4206.4504
5889.01
10095.46
Energy outlet (kJ/hr)
10095.48
10095.48
SULFONATOR
Qf
Qp
(235.8*1.17*30) + (10095.48) + [(228.2*1.3734)+(.437*4)] * 100
58128.25 kJ/hr
[(326.5*2.045) + (288.2*1.43136) + (4*.437) + (4.253*22.674)] *120
141524.46 kJ/hr
Heat of reaction:
No. of moles of anthraquinone taking part in the reaction = 1.13365 kmol/hr
C14H8O2
H2SO4
(in the presence of M)
HR
Hf
Hf
(Hf ASA + Hf W)
C14H8SO5 +
H2O
ASA
CpdT
-
(Hf A + Hf H)
Cp
CpdT
HR
Total heat
(-675320-285830) - (-58240-814000)
-88910 kJ/kmol
Cp Products
(588.96+76.554) (297.723+140.04)
228.474
228.474 * 95
-88910 + 21705.03 =
-76186.914 kJ/hr
Qp Qf + HR
7209.296 kJ/hr
Cp Reactants
21705.03 kJ/kmol
-67204.97 * 1.3365
Hence, heat should be supplied to get products at required temperature
Steam required,S
7209.296/2260
3.19 kg/hr
Assuming around 80% heat transfer efficiency in the equipments
Actual steam requirement, S
Streams
Reactant stream
Product stream
Heat of reaction
Steam
Total
4 kg/hr
Energy inlet (kJ/hr)
58128.25
Energy outlet (kJ/hr)
141524.46
76186.914
7209.4
141524.5
141524.46
CRYSTALLIZER
Qf
141524.46 + (15*4.187*25)
143094.6 kJ/hr
Qp
(326.5*2.045 + 288.2*1.311 + 4*.437 + 37.67*4.2) * 80
96448 kJ/hr
Heat to be removed =
Qp - Qf
-46646.6 kJ/hr
Brine water is to be supplied for this cooling purpose
Brine is available @ 288 K
Brine required
46646.6/(3.996*40)
179.6 kg/hr
Streams
Reactant stream
Product stream
Brine
Total
Energy inlet (kJ/hr)
143094.6
-
Energy outlet (kJ/hr)
96448
46646.6
143094.6
143094.6
Assuming 80% heat transfer efficiency, actual brine required = 225 kg/hr
PRECIPITATOR
Qf
= [(326.5*2.045 + 10*4.2) * 80] + [(34.63*.677 + 253.97*4.187) * 25]
= 84992.37 kJ/hr
Qp
= [ 151.53*3.5075 + (1.05*4.2)*280.97 + 192.63*2.045 ] * 85
= 183982.29 kJ/hr
Heat of reaction:
C14H8SO5 +
ASA
KCl
C14H7SO5K +
PAS
HCl
C
No. of moles of potassium anthraquinone-1-sulfonate formed = 0.4644 kmol
CpdT
HR
Hf
Hf
(Hf PAS + Hf C) -
(-1153981.62 167370) ( -675320 420680)
-225351.62 kJ/kmol
(Hf ASA + Hf P )
Cp
CpdT
HR
Total heat
Cp Products
(1144.357 + 25.8785) (588.96 + 50.485)
530.82 * 60
31849.23 kJ/kmol
-225351.62 + 31849.23
-193502.39 * 0.4644
-89862.76 kJ/hr
Qp Qf + HR
9127.157 kJ/hr
Steam required=
9127/2260
Cp Reactants
4.038 kg/hr
Assuming 80% efficiency, actual steam requirement = 5 kg/hr
Streams
Reactant stream
Product stream
Heat of reaction
Steam
Total
Energy inlet (kJ/hr)
84992.3725
89862.76
9127.01
183982.14
Energy outlet (kJ/hr)
183982.2896
183982.2
COOLER
Inlet temperature
85C
Outlet temperature =
25C
Qf
(133.5*3.5075 + 2.5*2.045 + .28*.709) * 85
40252.79 kJ/hr
11839.05 kJ/hr
Heat released
-28413.74 kJ/hr
Brine required
28413.74/(3.996*10)
Qp
711.05 kg/hr
Assuming 80% efficiency, actual brine requirement = 888 kg/hr
Streams
Reactant stream
Product stream
Brine
Total
Energy inlet (kJ/hr)
40252.79
-
Energy outlet (kJ/hr)
11839.05
28413.74
40252.79
40252.79
NEUTRALIZER
Qf
Qp
(11839.05 + 0.86*1.145*25)
11863.66 kJ/hr
(133.5*3.5075 + 0.45*.8645 + 4.326*2.7 + 0.14*4.187+.919*.35)*25
12030.7 kJ/hr
Heat of reaction:
Reaction 1:
2 C14H8SO5
Na2CO3
ASA
2 C14H7SO5Na +
NAS
CO2
CpdT
HR
Hf
Hf
(Hf NAS + Hf O + Hf W) - (Hf ASA + Hf S)
[-2*1091200 393500 285830] [-2*675320 1130770]
-380320 kJ/kmol
No. of moles of sodium carbonate reacted = 0.004355 kmol
CpdT
HR1 =
=
0
Hf
-1656.3 kJ/hr
H2O
W
Reaction 2:
2 HCl
Hf
Na2CO3
S
2 NaCl
CO2
H2O
W
(Hf N + Hf O + Hf W) - (Hf C + Hf S)
[-2*408760 393500 285830] [-2*167370 1130770]
-31340 kJ/kmol
No. of moles of sodium carbonate reacted = 0.003776 kmol
HR2 =
-118.33 kJ/hr
HR
HR1 +
1774.63 kJ/hr
HR2
Heat to be removed
+ HR
Qp - Qf
12030.7 11863.66 1774.63
-1607.6 kJ/hr
Brine required=
=
1607.6/(3.996*10)
40.23 kg/hr
Assuming 80% efficiency, actual brine requirement = 50 kg/hr
Streams
Reactant stream
Product stream
Heat of reaction
Brine
Total
Energy inlet (kJ/hr)
11863.66
1774.63
13638.3
Energy outlet (kJ/hr)
12030.7
1607.6
13638.3
RECYCLE HEAT BALANCES
PAN DRYER
Amount of solid to be dried
292.2 kg dry solid/hr
Inlet air temperature, Tg2
120C
Outlet air temperature, Tg1
85C
Inlet solids temperature, Ts1
85C
Outlet solids temperature, Ts2
100C
Assumptions:
@ 25C, humidity of air is 50% (which is available from flue gas)
Hence, absolute humidity of available air = 0.01 kgwater/kg dry air
Y2
The enthalpy of air entering the drier,HG2=
[(Cg + Y2Cv)(Tg2 To) + Y2]
Specific heat of air,
Cg
1.005 kJ/kgC
Specific heat of vapor,
Cv
1.884 kJ/kgC
Enthalpy of vapor,
2502.3 kJ/kg
HG2
147.882 kJ/kg
HG1
(1.005+1.884Y1)85 + 2502.3
85.425 + 2662.44 Y1
The enthalpy of the solid entering the drier,
Hs1
Cp(Ts1 To) + X1(Ts1 To) Cw
(1.311+ 0.077*4.187) * 80 kJ/kg
130.7014 kJ/kg
The enthalpy of the solid leaving the drier,
Hs2
1.369*100
136.9 kJ/kg
Assuming no heat loss due to radiation to the surroundings
Moisture balance:
Ss X1
Gs Y2
Ss X2
Ss(X1 X2)
Gs(Y1 + Y2)
292.2(0.077)
Gs(Y1 + 0.01)
Gs(Y1 0.01)
22.5
Gs HG2
Ss Hs2 +
Gs Y1
Enthalpy balance:
Ss Hs1 +
292.2*130.7 +
Gs(147.882)
Gs(62.458 2662Y1)
Gs HG1 +Q
= 292.2(136.9) + Gs(85.424 + 2662Y1) + 0
=
1837.78
By solving,
Gs
1724.13 kg dry air /hr
Y1
0.023
Heat source
Ss Hs1
Gs HG2
Ss Hs2
Gs HG1
Total
Heat in kJ/hr
38190.54
254964.34
293154.88
Heat out kJ/hr
40002.18
253151.17
293153.35
COOLER
Qf
Qp
Qp Qf
(172.63*2.045 + 13*0.709 + 229.97*4.2) * 85
112890.1448 kJ/hr
(172.63*2.045 + 13*0.709 + 229.97*4.2) * 25
33203 kJ/hr
-79687.14 kJ/hr
Brine required=
=
68533.856/(3.996*10)
1994.17 kg/hr
Streams
Feed stream
Product stream
Brine
Total
Energy inlet (kJ/hr)
112890.1448
112890.1448
Energy outlet (kJ/hr)
33203
79687.14
112890.14
NEUTRALIZER 2
Qp
Qp
(172.63*2.045 + 13*0.709 + 229.97*4.2 + (50.65*1.145)) * 25
34652.85 kJ/hr
(185.824*4.426 + 238.57*4.187 + 20.836*0.709 + 21.024*0.919)*25
46386.084 kJ/hr
Heat of reactions:
Same reactions as the previous neutralizer occur
HR1
-380320 kJ/kmol
No. of moles of sodium carbonate reacted = 0.6 kmol
HR2
-31340 kJ/kmol
No. of moles of sodium carbonate reacted = 0.356 kmol
Total heat of reactions=
Total heat
- 228192 - 11162.4
- 239354.4 kJ/hr
46386.084 34652.85 239354.4
Heat to be removed =
-227621.16 kJ/hr
Brine required
1.582 kg/s
Streams
Reactant stream
Product stream
Heat of reaction
Energy inlet (kJ/hr)
34652.85
239354.4
Energy outlet (kJ/hr)
46386.084
-
Brine
Total
274007.25
227621.16
274007.244
EVAPORATOR
Qf
46386.084 kJ/hr
Evaporator operated @ 120 C to completely vaporize water
Qp
(185.824*4.426 + 20.836*0.709 + 21.024*0.919)*120 + 2260*238.57
641954.29 kJ/hr
Qp Qf=
-595568.2125 kJ/hr
263.5 kg/hr
Assuming 80% efficiency in heat transfer equipments steam requirement is 330 kg/hr
Streams
Feed stream
Product stream
Steam
Total
Energy inlet (kJ/hr)
46386.084
595568.2125
641954.29
Energy outlet (kJ/hr)
641954.29
641954.29