Building Inspections
Isometric Plumbing Drawings
All commercial building permit applications, in which the plumbing system has not been designed by a
mechanical engineer, must include two sets of isometric plumbing drawings.
The isometric drawings should include the following information:
1.
Isometric drawings of drain, waste and vent (D.W.V.) must include the size, location and type of pipe.
2.
Isometric drawings of hot and cold water piping must include the type and size of pipe and method
used for sizing pipe.
3.
The isometric drawings are to specify whether combustible or non-combustible plumbing is to be used.
It is the responsibility of the designers to ensure the system complies with the BC Building Code
requirements in Subsection 3.1.9. or 9.10.9.7., Fire Separations & Fire Rated Assemblies.
4.
Grease traps must be installed in the plumbing system for restaurants and businesses that prepare
food. The location and size of the grease interceptors must be included on the isometric drawing. For
further information see the Building Inspections handout titled Grease Interceptors in Kitchens.
5.
Isometric drawings to include the plumbing company name and contact phone number.
The isometric plumbing drawing approved by the City of Nanaimo must be supplied, on site, at the time of the
Plumbing Inspectors inspection.
Revised: 2013-May-02
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines
Page 1 of 8
Example Drainage System Isometric View
3
1 1/2 ABS
1 1/2
Kitchen sink
1 1/2
Lavatory
WC
2
3
Lavatory
2 ABS
Required Information
3
2 ABS
Washer 2 trap
Sizing of drains
Sizing of vents
Location of cleanouts X
List of fixtures
Type of piping
Location & size of grease
traps & floor drains (where
applicable)
3
Laundry
tray
Revised: 2013-May-02
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines
Page 2 of 8
Example Commercial Water Piping - Isometric View
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines
Page 3 of 8
Example Residential Water Piping - Isometric View
shower
lavatory
Cold Water
A
water
closet
Kitchen sink
&
dishwasher
water
heater
J
G
meter
hose
bibb
D
hose
bibb
F
E
shower
lavatory
Hot Water
E
water
heater
kitchen
sink &
dishwasher
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines
Page 4 of 8
Simplified Method SFD / Duplex
Total number of Water Supply Fixture Units
Fixture
WSFU
Total
BG
WC
LAV
BT
SH
K.S.
D.W.
C.W.
H.B.
WSP
3.6
2.2
0.7
1.4
1.4
1.4
1.4
1.4
2.5
2
2
2
1
1
2
2
2
2
7.2
4.4
1.4
1.4
1.4
2.8
2.8
2.8
5
29.2
Hot
4.2
Value of hot fixtures only
in 2 bathroom groups
1.4
1.4
1.4
2.8
2.8
2.8
16.8
Taken from Tables 2.6.3.2.A., 2.6.3.2.B., 2.6.3.2.C. and 2.6.3.2.D.
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines
Page 5 of 8
Simplified Method SFD / Duplex
Introduction to Water Pipe Sizing 2012 BCPC
Fixt. FU
Hot
BG
3.6
4.2
WC
2.2
LAV
0.7
1.4
BT
1.4
1.4
SH
1.4
1.4
K.S.
1.4
2.8
1.4
2.8
1.4
2.8
2.5
D.W
.
C.W
.
H.B.
WSP
16.8
Hot Water
Distribution
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
Size of
Water Pipe
(Inches)
Velocity
2.4 m/s
FU Load
16
31
57
City of Nanaimo Guidelines
Page 6 of 8
Simplified Method SFD / Duplex
Introduction to Water Pipe Sizing 2012 BCPC
Fixt. FU
Total
BG
3.6
7.2
WC
2.2
4.4
LAV
0.7
1.4
BT
1.4
1.4
SH
1.4
1.4
K.S.
1.4
2.8
D.W. 1.4
2.8
C.W. 1.4
2.8
H.B.
WSP
2.5
29.2
Cold Water
Distribution
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
Size of
Water Pipe
(Inches)
Velocity
2.4 m/s
FU Load
16
31
57
City of Nanaimo Guidelines
Page 7 of 8
Water Pipe Sizing Worksheet
Company:
Drawn by:
Phone:
Single Family / Duplex / Row Housing
BP #:
Address:
Each unit having separate water service
Cold
Fixture:
F/Un
Total
BATHROOM GROUP
WC
LAV
BT/SHOWER 1/2" SPOUT
BT 3/4" SPOUT
SHOWER PER HEAD
KITCHEN SINK
DISHWASHER
CLOTHES WASHER
HOSE BIBB 1/2"
HOSE BIBB 3/4
HOSE BIBB 3/4" H/C
BAR SINK
LAUNDRY TUB
BIDET
Items not listed
Supply
3/8
1/2"
3/4
1
Hydraulic load
Private Public
1
2
2
4
3
6
6
10
3.6
2.2
0.7
1.4
10
1.4
1.4
1.4
1.4
2.5
3
2.5
1
1.4
2
Num/of
Fixtures
Cold
F/Un
Hot
F/Un
PIPE
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
SIZE
1/2"
3/4"
1
1 1/4
PEX
2.4
7
16
31
57
Cold
F/Un
SIZE
Hot
F/Un
SIZE
TYPE OF PIPING
X
PEX
COPPER
OTHER
COMMENTS:
Revised: 2013-Apr-23
G:\DSDSystem\Handouts\Building\IsometricPlumbingDrawing Requirements.docx
City of Nanaimo Guidelines