NFPA EQUIPMENT SIZING GUIDE - VACUUM SYSTEM
Name of Facility:
Project Number:
ENTER REQUIRED DATA IN THE BLUE SHADED AREAS BELOW
VACUUM - NFPA Method
LOCATION OF OUTLETS
Units Required
Units
Outlet CFM
Simutanious Use
%
Outlet CFM
Anesthetizing Location
1
2
3
Operating Room
Cystoscopy
Delivery
0
0
0
Room(s)
Room(s)
Room(s)
3.5
2
1
100
100
100
4
5
6
7
Special Proced. (Open heart, Transplant, etc.)
Emergency/ Major Trauma Room
Other Anesthetizing Location
Evacuation Vacuum
0
0
0
0
Room(s)
Room(s)
Room(s)
Room(s)
4
3
1
2
100
100
50
100
1
2
3
4
(Non-Anesthetizing)
Recovery Room
I.C.U (Except Cardiac)
Cardiac I.C.U
Emergency Room
0
0
0
0
Bed(s)
Bed(s)
Bed(s)
Bed(s)
1.5
2
1
1
50
75
50
100
5
6
7
8
Special Procedures (X-Ray, dialysis, etc.)
Catherterization Lab
Surgical Excision Room
Neonatal I.C.U,
0
0
0
0
Room(s)
Room(s)
Room(s)
Bed(s)
1.5
1
1
1
30
10
10
50
1
2
3
4
5
(Non-Anesthetizing)
Patient Room - Surgical
Patient Room - Medical
Exam & Treatment Room
Nursery
Nursery Premature
0
0
0
0
0
Bed(s)
Bed(s)
Room(s)
Bassinet(s)
Bassinet(s)
1.5
1
1
1
1
15
10
10
10
25
1
2
3
4
5
6
7
Respiratory Care Dep't
Teaching
Autopsy
Location1: Vac*
Location2:
Location3:
Location4:
0
0
0
0
0
0
0
Room(s)
Room(s)
Table(s)
Outlet(s)
Outlet(s)
Outlet(s)
Outlet(s)
1.5
1.5
1.5
3
10
10
10
100
Acute Care Location
Sub-Acute Patient Care
Other Patient Rooms
0.00
Future Expansion
PEAK CALCULATED DEMAND IN SCFM @ 19"hg:
Altitude above sea level, ft:
PEAK CALCULATED DEMAND IN SCFM @ 19"hg, ALTITUDE ADJUSTED:
0.00
#N/A
NOTE: The system model below are provided as a reference and variation of the systems are available. Please contact your
local sales rep for details.
* Maybe used alone if you wish to only count outlets needed. You may change that field as you see fit.
Amico Source Contact Information
Project Management - USA
Project Management - Canada
Project Management - International
Parts
Tech Support
Telephone
1-877-462-6426
1-877-462-6426
1-877-462-6426
1-877-462-6426
1-888-770-6035
E-MAIL
as-usa@[Link]
as-canada@[Link]
as-intl@[Link]
as-parts@[Link]
as-techsupport@[Link]
Lubricated Rotary Vane System
System Model #
Drawing Link
Tank Mount Horizontal
#N/A
#N/A
Tank Mount Space Saver
#N/A
#N/A
Duplex Skid Mount
#N/A
#N/A
Triplex Skid Mount
#N/A
#N/A
Quadraplex Skid Mount
#N/A
#N/A
Dry Rotary Vane System
System Model #
Drawing Link
Tank Mount Horizontal
#N/A
#N/A
Tank Mount Space Saver
#N/A
#N/A
Duplex Skid Mount
#N/A
#N/A
Triplex Skid Mount
#N/A
#N/A
Quadraplex Skid Mount
#N/A
#N/A
Dry Contactless Claw System
System Model #
Drawing Link
Tank Mount Horizontal
#N/A
#N/A
Tank Mount Space Saver
#N/A
#N/A
Duplex Skid Mount
#N/A
#N/A
Triplex Skid Mount
#N/A
#N/A
Quadraplex Skid Mount
#N/A
#N/A
NFPA EQUIPMENT SIZING GUIDE - AIR COMPRESSOR SYSTEM
Name of Facility:
Project Number:
ENTER REQUIRED DATA IN THE BLUE SHADED AREAS BELOW
LOCATION OF OUTLETS
MEDICAL AIR - US Typical Method
Simutanious Use
Outlet CFM
%
Units Required
Units
Outlet CFM
Surgical Procedures
1
2
3
4
5
6
7
PreOp Holding
Major Invasive
Minor Invasive
Trauma and Emergency
Catherization & Lab work
Endoscopy
Recovery
1
2
3
4
5
6
7
X-ray, CAT, NMR, PET scans
Dialysis
Exam and Minor Treatment
EEG/EKG
Pulmonary Function
Respiratory Care
Observation
1
2
3
4
Birthing or LDRP
Delivery Room
Nursery
NICU
1
2
3
Adult ICU, CCU, etc.
Pediatric ICU (Except NICU)
Emergency (not surgical)
Workrooms
Medical Lab Uses
1
2
3
4
5
6
Patient rooms
Ventilator
Location1: Critical*
Location2: Non Critical*
Location3: Support Gas*
Location4:
0
0
0
0
0
0
0
Bed(s)
Room(s)
Room(s)
Room(s)
Room(s)
Room(s)
Bed(s)
1
3.5
2
3
1
2
1.5
10
100
100
100
10
100
50
0
0
0
0
0
0
0
Room(s)
Bed(s)
Room(s)
Room(s)
Bed or outlet
Bed or outlet
Bed or outlet
1.5
1.5
1
1
1.5
1.5
1
30
30
10
10
30
30
10
0
0
0
0
Room(s)
Room(s)
Bed(s)
Bed(s)
1
0.5
0.5
1.5
100
100
10
50
0
0
0
Bed(s)
Bed(s)
Bed(s)
2
2
2
50
50
10
Outlet(s)
1.5
10
Outlet(s)
1.5
25
0
0
0
0
0
0
Room(s)
Unit(s)
Outlet(s)
Outlet(s)
Outlet(s)
Outlet(s)
0.5
3
6
3.5
5
10
50
100
100
100
Tests and Outpatient Procedures
Perinatal and Pediatric
Intensive Care
Equipment Maintenance
Laboratory
Other
0.00
Future Expansion
PEAK CALCULATED DEMAND IN SCFM:
NOTES:
1. The SCFM above is based on a peak OUTLET demand of 50 psi. Air compressors operate at 100 psi. When sizing a compressor, you MUST
figure the compressor capacity for operation at 100 psi.
0.00
2. Air outlets in labs used for analysis, research or teaching should be supplied by a seperated compressed air system, not medical air system.
3. * Maybe used alone if you wish to only count outlets needed. You may change that field as you see fit.
Altitude above sea level, ft:
Intake air temperature, F:
Relative Humidity, %:
0%
PEAK CALCULATED DEMAND IN SCFM, ADJUSTED:
NOTE: The system model below are provided as a reference and variation of the systems are available. Please contact your
local sales rep for details.
Amico Source Contact Information
Project Management - USA
Project Management - Canada
Project Management - International
Parts
Tech Support
Telephone
1-877-462-6426
1-877-462-6426
1-877-462-6426
1-877-462-6426
1-888-770-6035
E-MAIL
as-usa@[Link]
as-canada@[Link]
as-intl@[Link]
as-parts@[Link]
as-techsupport@[Link]
Oil-less Scroll System
System Model #
Drawing Link
Tank Mount Horizontal
#N/A
#N/A
Duplex Skid Mount
#N/A
#N/A
Triplex Skid Mount
#N/A
#N/A
Quadraplex Skid Mount
#N/A
#N/A
Oil-less Reciproating System
System Model #
Drawing Link
Tank Mount Horizontal
#N/A
#N/A
Duplex Skid Mount
#N/A
#N/A
Triplex Skid Mount
#N/A
#N/A
Quadraplex Skid Mount
#N/A
#N/A
#N/A