The document describes a type of pressure regulator called an RP/10. It provides technical details on features like allowable pressure ranges, materials used, flow rate tables, dimensions and weights. The regulator uses a diaphragm and shutter to balance inlet and outlet pressures and maintain a set downstream pressure.

Uploaded by

pravesh sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views4 pages

PRV PDF

The document describes a type of pressure regulator called an RP/10. It provides technical details on features like allowable pressure ranges, materials used, flow rate tables, dimensions and weights. The regulator uses a diaphragm and shutter to balance inlet and outlet pressures and maintain a set downstream pressure.

Uploaded by

pravesh sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PRESSURE REGULATORS

Type RP/10

TM

Process Management
RP/10 Regulators

Type RP/10 Pressure Loaded Regulators


RP/10 regulators are pneumatic-loaded and feature counterbalanced valve.

The RP/10 regulators are normally employed in pressure reducing stations using high pressure gas compressed in
cylinders.

They can also be employed with middle pressure gas in ceramic, chemical, and pharmaceutical factories for small
furnaces.

The main features are as follows:

• Counterbalanced Shutter
• Built-in Relief Valves

Operation
The stem S is controlled by the diaphragm unit M on the opposite surfaces of which are balanced in one side the
downstream pressure and on the other side the setting static pressure.

The causes that can intervene to modify this state of balance are:

1. increase of the request of gas


2. reduction of the request of gas
3. increase of the inlet pressure
4. reduction of the inlet pressure

An Increase of the request of gas causes a


reduction of the downstream pressure in the
chamber C1.

The difference of pressure which is thus formed C


between the chambers C and C1 operating on M
the diaphragm unit M causes the opening of the
shutter O until the balance of the setting and
downstream pressure is obtained again. C1
S
In the case 2 a reduction of the request of gas
causes an increase of the downstream pressure.

The downstream pressure prevailing on the


setting pressure causes a rising of the diaphragm
unit M and therefore of the shutter O.
O
The reduction of useful section for the passage
which is the con­sequence of this, reduces the
downstream pressure to its initial value.

The cases 3 and 4 are similar to the previous


ones because, to the effects of the operation,
an Increase or a reduction of the absorption
corre­spond respectively to a reduction or to an
increase of the inlet pressure. Inlet Pressure Downstream Pressure Setting Pressure

2
RP/10 Regulators

Features
Technical Features
Body allowable pressure PS : 220 bar
Inlet pressure range bpu : 1 to 220 bar
Outlet Set Pressure Ranges Wd : 0,5 to 30 bar

Functional Features
Accuracy class AC : up to ±5%
Lock-up pressure class SG : up to 10%
Class of lock-up pressure zone Sz : up to 10%

Orifice
3/4"

Connections
3/4" x 1" BSP
Provided with butt weld ends:
Inlet Ø 17,2 mm - Outlet Ø 26,5 mm

Temperature
Working -10° to 60 °C

Materials Body Steel


Covers Steel
Seat Stainless Steel
Diaphragm Fabric Nitrile (NBR) Rubber + PVC
Pad Nitrile NBR or
Fluorocarbon FKM

Flow Rates Table (Stm3/h)


pd
pu 0.5 0.8 1 1.25 1.5 1.8 2 2.5 3 3.5 4 4.5 5 6 7 8 9 10 12.5 15 17.5 20 25 30
1 60 40
1.5 85 75 70 50 Verify that the velocity of the gas at the downstream pipeline of the
regulator does not exceed 25 m/s using the following formula:
2 110 100 100 90 75 50
3 145 145 140 135 125 120 90 Q 1 - 0.002 ⋅ Pd V = Velocity in m/s
V = 345.92 ⋅ ⋅
2 345.92 = Numerical constant
4 180 180 180 175 170 160 140 105 DN 1 + Pd
Q = Flow rate in Stm3/h
5 220 220 220 205 195 180 155 115 DN = Pipeline diameter
Pd = Outlet pressure in bar g
6 255 255 245 235 220 200 170
Pu = Inlet pressure in bar g
7.5 310 310 300 290 280 265 225 140
10 400 400 385 365 340 295 220
12.5 500 500 480 465 440 410 360
15 580 580 555 540 510 400
20 765 765 740 700 615 470
30 1130 1100 1060 1000 790
40 1490 1455 1370 1215
50 1855 1810 1735
75
100
125
145 180 220 220 255 255 310 330 400 400 500 580 580 650 765 850 950 1130 1250 1490 1855 2000 2000 2000
150
175 Flow rates higher than these values ​​are not possible because this would cause too high gas velocity in the outlet fitting
220
Pressures in bar and flow rates in Stm 3/h referred to natural gas.

3
Dimensions (mm) and Weights (kg)

Ø 180

225

321
Ø 17,2

Ø 26,5
S
C C
A A
R R
I I
C C
O O

200 10
100 300 5 20

0 400 0 25

bar bar

96
155 165

320
Weight: 17 Kg

Industrial Regulators Natural Gas Technologies LP-Gas Equipment TESCOM

Emerson Process Management Emerson Process Management Emerson Process Management Emerson Process Management
Regulator Technologies, Inc. Regulator Technologies, Inc. Regulator Technologies, Inc. Tescom Corporation

USA - Headquarters USA - Headquarters USA - Headquarters USA - Headquarters


McKinney, Texas 75070 USA McKinney, Texas 75070 USA McKinney, Texas 75070 USA Elk River, Minnesota 55330-2445 USA
Tel: +1 800 558 5853 Tel: +1 800 558 5853 Tel: +1 800 558 5853 Tel: +1 763 241 3238
Outside US: +1 972 548 3574 Outside US: +1 972 548 3574 Outside US: +1 972 548 3574 +1 800 447 1250

Europe Europe Europe


Bologna 40013, Italy Bologna 40013, Italy Selmsdorf 23923, Germany
Tel: +39 051 419 0611 Tel: +39 051 419 0611 Tel: +49 38823 31 287
Chartres 28008, France
Asia-Pacific Tel: +33 2 37 33 47 00 Asia-Pacific
Shanghai 201206, China Shanghai 201206, China
Tel: +86 21 2892 9000 Asia-Pacific Tel: +86 21 2892 9499
Singapore 128461, Singapore
Middle East and Africa Tel: +65 6770 8337
Dubai, United Arab Emirates
Tel: +971 4811 8100 Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100

For further information visit [Link]/regulators

Our Global Product Brands:

TM

TM

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher, Tartarini, Francel, Emerson Process Management and the Emerson
Process Management design are marks of the Emerson Process Management group of companies.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express
or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process
Management product remains solely with the purchaser.

O.M.T. Officina Meccanica Tartarini S.R.L., Via P. Fabbri 1, I-40013 Castel Maggiore (Bologna), Italy
R.E.A 184221 BO Cod. Fisc. 00623720372 Part. IVA 00519501209 N° IVA CEE IT 00519501209, Cap. Soc. 1.548 000 Euro i.v. R.I. 00623720372 - M BO 020330
Francel SAS, 3 Avenue Victor Hugo, CS 80125, Chartres 28008, France
SIRET 552 068 637 00057 APE 2651B, N° TVA : FR84552068637, RCS Chartres B 552 068 637, SAS capital 534 400 Euro

D104056X012 - 02/2015 - Rev.00©Emerson Process Management Regulator Technologies, Inc., 2015; All Rights Reserved

You might also like