Power and Control Cable IEC 60502-1: Flame Retardant, Sunlight Resistant 90 °C / U /U 0,6/1 KV

Uploaded by

Shashank Saxena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
250 views2 pages

Power and Control Cable IEC 60502-1: Flame Retardant, Sunlight Resistant 90 °C / U /U 0,6/1 KV

Uploaded by

Shashank Saxena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Power and Control Cable IEC 60502-1

Flame Retardant, Sunlight Resistant 90 °C / Uo/U 0,6/1 kV


XLPE-Insulation, PVC-Sheath

2XY-fl
Application
For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group II classified areas (IEC 60079-14).
(Please note possible additional or special installation requirements of IEC 60079-14).
Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations; for direct burial. Indoor installation is allowed in
areas where the construction products regulation (CPR) acc. to EN 50575 of fire class is not required. (Please note the relevant legal / local installation
requirements)
Construction
Conductor plain annealed copper wire , class 1 (circular solid, RE) or class 2 (circular
................................................. stranded, RM) according to IEC 60228
Insulation cross-linked polyethylene XLPE
.................................................
Colour black
................................................. * (other colours on request)
Outer polyvinyl chloride PVC, black
.................................................
Cable LEONI KERPEN ELECTRIC CABLE SIZE 0.6/1 kV IEC 60502-1
................................................. YEAR PRODUCTION LOT CODE LENGTH MARKING

Technical data Abbreviations


Flame propagation Temperature range Power and Control Cable
- Test on single cable IEC 60332-1-2 -30°C up to +90°C 2X XLPE insulation
- Test on bunched cables IEC 60332-3-24 (Cat. C) (during operation) Y PVC outer sheath
-5°C up to +50°C -fl reduced flame propagation
Limiting Oxygen Index (LOI) ASTM D 2863 (min. 30 %)
(during installation)
Flammability temperature (FT) ISO 4589-3 ann. A (min. +250 ° C) max. +250°C
Amount of halogen acid gas IEC 60754-1 (max. 17 %) (under short circuit)
Oil resistance ICEA S-73-532 Minimum bending radius
Sunlight resistance UL 1581 section 1200 8 x cable diameter

Electrical Properties at 20 °C
Conductor resistance max. Ω/km according to IEC 60228
Test voltage Urms (core : core) V 3500
Nominal Voltage U0 / U 0,6 / 1 kV
Highest system voltage Um max. V 1200 (for three phase systems)

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · [Link]/en/


Print date: 27.08.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 05.05.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 1/2
For cable disposal please note the relevant local legal disposal requirements.
2001210000_IEC_60502-1_ 2XY-fl_black_RE-RM-Core_en.pdf
Power and Control Cable IEC 60502-1

Flame Retardant, Sunlight Resistant 90 °C / Uo/U 0,6/1 kV


XLPE-Insulation, PVC-Sheath

2XY-fl
Geometrical data
Size RT of insulation RT of outer sheath Outer dia. Weight Part No.
nom. nom. approx. approx. Colour
mm mm mm kg/km black
1
1 x 10 RM 0,70 1,4 8,3 152 LKX208103970000
1 x 16 RE 0,70 1,4 8,7 198 LKX208100060000
1 x 16 RM 0,70 1,4 9,4 213 LKX208100070000
1 x 25 RM 0,90 1,4 10,8 308 LKX208100080000
1 x 35 RM 0,90 1,4 11,9 407 LKX208100090000
1 x 50 RM 1,00 1,4 13,2 535 LKX208100100000
1 x 70 RM 1,10 1,4 15,2 732 LKX208100110000
1 x 95 RM 1,10 1,5 17,0 1006 LKX208100120000
1 x 120 RM 1,20 1,5 18,5 1227 LKX208100130000
1 x 150 RM 1,40 1,6 20,5 1514 LKX208100140000
1 x 185 RM 1,60 1,6 22,7 1872 LKX208100150000
1 x 240 RM 1,70 1,8 25,6 2436 LKX208100160000
1 x 300 RM 1,80 1,8 28,4 3045 LKX208100170000
1 x 300 RM 1,80 1,8 28,4 3153 LKX208105470000
1 x 400 RM 2,00 1,9 32,0 3889 LKX208100180000
1 x 500 RM 2,20 2,0 36,9 4972 LKX208100190000
1 x 630 RM 2,40 2,2 43,1 6601 LKX208100200000
1 x 800 RM 2,60 2,3 47,8 8399 LKX208100900000
1 x 1000 RM 2,80 2,4 51,9 10322 LKX208100890000
RT = Radial Thickness

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · [Link]/en/


Print date: 27.08.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 05.05.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 2/2
For cable disposal please note the relevant local legal disposal requirements.
2001210000_IEC_60502-1_ 2XY-fl_black_RE-RM-Core_en.pdf

You might also like